Raco Catalyst Addendum To Owner's Manual

Other manuals for Catalyst: Owner's Manual
Manual is about: Ethernet Module Setup

Summary of Catalyst

  • Page 1

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 1 (21) addendum to catalyst owner's manual how to configure a catalyst ethernet/ip with rslogix 5000 addendum 1.1.

  • Page 2: Document History

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 2 (21) document history revision date description author 1.00 2014-3-17 document created michael jammal 1.1 2014-4-14 modifications and verification j. Garnett, s. Pottier 1.2 2014-4-15 u...

  • Page 3

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 3 (21) raco manufacturing and engineering continually makes improvements in the operation and functionality of its products. This addendum describes catalyst ethernet communication option...

  • Page 4: Introduction

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 4 (21) introduction are you familiar with the operation of the catalyst data logger/autodialer yet? Changes to a few, very specific features of the catalyst are described in this addendum...

  • Page 5: 3.  Requirements

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 5 (21) 3. Requirements description name / type version rockwell plc controllogix5000 n.A. Plc software rslogix 5000 13.04.00 raco ipconfig tool raco ipconfig 2.1.1.1 catalyst ethernet/ip ...

  • Page 6: Protocol

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 6 (21) 4. Determining net port number & protocol identifier the catalyst ethernet supports one communication port, named net 1. In this version of the product, the ethernet connectivity i...

  • Page 7

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 7 (21) • catalyst with ethernet autodialers don’t work this way. All the different areas are mapped on top of one another. 30001 holds the same value as 40001. Coil 00001 holds the same v...

  • Page 8

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 8 (21) table #2 illustrates the modbus data file convention within the catalyst. These modbus register addresses map to the rockwell automation controller’s registers as per the modbus ta...

  • Page 9

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 9 (21) figure 1 hardware connection overview. 8. Ethernet/ip configuration before you begin: ensure that the eds file (found on the “ethernet ip configuration tools” cd that was shipped w...

  • Page 10

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 10 (21) figure 2 adding the plc to the configuration..

  • Page 11

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 11 (21) then add the ethernet i/o module. Right click on the i/o configuration directory in the navigation list to the left as seen below. Figure 3 adding the ethernet module. Click on ne...

  • Page 12

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 12 (21) then enter the desired settings and press finish. Figure 5 configuring the settings for the ethernet module. 8.2. Ethernet/ip network configuration the second step is to configure...

  • Page 13

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 13 (21) now a dialogue window will appear. In this dialogue window, select “generic ethernet module” and press ok. Figure 7 selecting the generic ethernet module. In the next dialogue win...

  • Page 14

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 14 (21) possible to select data-int, which will represent the data as 16-bit values, and data-dint, which will represent it as 32 bit values. I/o data is accessed in input instance 100 an...

  • Page 15

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 15 (21) in this dialogue we will enter a value for the time between each scan of the module. In this example, we have set the interval to 50 ms to reduce the network load. Make sure that ...

  • Page 16

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 16 (21) select “go online” from the “communications” menu. Figure 12 opening the online window. A new window appears, select “download”. Figure 13 the download window..

  • Page 17

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 17 (21) a new window will popup with the question if you actually want to download the configuration, select “download”. The configuration will now be downloaded to the plc. Figure 14 dow...

  • Page 18

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 18 (21) the raco ipconfig tool runs independently of alarmware and search the network to find the raco autodialers that are present in the network. The raco ipconfig program can be downlo...

  • Page 19: 10.  Testing

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 19 (21) 9.2. Setting catalyst remote channels setting up the remote channels in the alarmware application is described clearly in the main catalyst manual (ref: 1.1.2 net addresses). Sett...

  • Page 20: 11.  Quick Start

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 20 (21) 11. Quick start 1) set up catalyst: (note that although some catalyst parameters can be configured with the front panel keys, catalyst ethernet will need to be configured with ala...

  • Page 21

    Saved: 2014-06-18 filename: catalyst ethernet addendum 1 1 v1_5 released raco manufacturing and engineering page 21 (21) for a remote analog (16-bit) channel use sna 1*2*40xxx where xxx is the 16-bit register example: 1*2*40101 for modbus register 40101 set the alarm condition under channel settings...