Radiancy FSD+ User Manual

Manual is about: Facial SkinCare Device

Summary of FSD+

  • Page 1

    User manual facial skincare device.

  • Page 2

    Before using radiancy fsd plus for the first time, we strongly recommend reading through the user manual in its entirety. Pay particular attention to the sections: treatment protocols, operating procedures and post treatment protocols. © 2007-2013 radiancy inc. All right reserved. Fsd plus (facial s...

  • Page 3: Table of Contents

    Table of contents introduction to fsd plus 4 safety instructions 5 device description 8 know before yo...

  • Page 4

    4 1. Introduction to fsd plus fsd plus represents a breakthrough in the skin care cosmetic market with lhe ® microphototherapy at its core, fsd plus can be used either for stand-alone treatments or as a part of a more comprehensive skin care program fsd plus is based on radiancy’s patented lhe ® t...

  • Page 5: 2.  Safety Instructions

    5 2. Safety instructions as with any electrical device, certain precautions must be taken in order to ensure your safety read all instructions before use all warnings and cautions should be strictly followed warnings - to reduce the risk of injury 1. Use this device only for its intended use as d...

  • Page 6

    6 cautions 1. Do not apply to tanned skin 2. Cover birthmarks prior to treatment 3. Never look directly at the light coming from the handpiece as this may cause eye injury 4. Do not use this device on the eyelids or eye socket area 5. Always use protective eyewear 6. Never point the handpiece s...

  • Page 7

    7 contraindications do not use this device if your client: 1. Is skin type 6 2. Is pregnant or lactating 3. Was exposed to strong sunlight or an artificial tanning machine in the past 21 days 4. Has a tattoo or permanent makeup in the treatment area 5. Has used medications, herbal preparations, ...

  • Page 8: 3.  Device Description

    8 3. Device description fsd plus is made up of three main components; the main unit, the handpiece, and the power cord main unit: hand piece control panel pulse counter on/off switch.

  • Page 9

    9 control panel: the control panel contains indicator lights for power, ready and charging there is also a mute switch, and energy level settings for low, medium and high energy levels mute button ready indicator light charging indicator light power on light hand piece: accessories: pulse button t...

  • Page 10

    10 device set up use of accessories and cables other than those specified, with the exception of cables sold by the manufacturer as replacement parts for internal components, may result in increased emissions or decreased immunity of the device 1. Before you plug in the device, verify that the lua ...

  • Page 11: 4.  Know Before You Start

    11 4. Know before you start the counter fsd plus features a pulse counter window this will help you to better plan your treatments and advise you when to replace the lua lamp treatment pulses (treat): this line counts the amount of pulses per treatment reset the treatment counter by turning the u...

  • Page 12

    12 general guidelines fsd plus can be used as a stand alone treatment, or may be combined with other skin care routines while you should rely on your experience and expertise in this area, we recommend the following treatment regimen as to the best way to incorporate fsd plus into a comprehensive s...

  • Page 13

    13 •differences in skin type, biology and comfort levels usually dictate that you must initially treat at the lower energy level settings after the first 1-2 treatment sessions, however, the skin generally becomes less sensitive, which will allow you to gradually increase the energy level during su...

  • Page 14

    14 scheduling for optimal results, fsd plus treatments should be performed twice a week for 4 to 5 weeks maintenance treatments can be performed once a month or as needed 5. Operating instructions test always test your client’s reaction to fsd plus before beginning the actual treatment deliver 1-...

  • Page 15: Treatment

    15 treatment 1. Thoroughly cleanse and dry the skin 2. Apply a hygienic ring to the treatment head you may reuse a hygienic ring for each client use a different hygienic ring for each client 3. Press the power switch found on the top of the device when the ready indicator lights up, start treat...

  • Page 16

    16 5. Press and hold the pulse switch to trigger a sequence of therapeutic light pulses this sequence takes a few seconds, depending on the energy level setting (see specifications) if during the pulse sequence the light unit assembly feels too hot on the skin, remove it immediately and wait until...

  • Page 17

    17 8. After covering the entire area, wait one to two minutes to allow the skin to cool down then repeat the procedure making sure to begin at the initial starting point with the handpiece held vertically 9 . When treatment is complete, turn the device off by pressing the power switch notes: •wait...

  • Page 18: 6.  Maintenance

    18 post treatment •avoid sun exposure or protect skin with sunscreen throughout the treatment process and for at least for 3 weeks following the last use •use a moisturizing sunscreen (spf 30 or higher) for at least 3 weeks after treatment •some device users may experience hyperpigmentation result...

  • Page 19

    19 to insert or replace the lua: picture a picture b 1. Turn the device off and unplug the cord from the electrical outlet 2. Grasp the lua by both ends and pull it out of the socket (picture a) 3. Line up the holes in the socket with the metal and plastic posts in the lua and push it gently into ...

  • Page 20: 7.  Troubleshooting

    20 7. Troubleshooting if the device does not start: •make sure that the power cord is connected into the wall electrical outlet •check the fuse inside the fuse drawer replace fuse if blown (see instructions on fuse replacment section) •if a pulse sequence is not released when pressing the pulse s...

  • Page 21

    21 8. Standards, safety and specifications design and technical specifications are subject to change without notice international standards fsd plus complies with the following international standards and directives: electrical safety medical electrical equipment – part 1: general requirements for ...

  • Page 22

    22 declaration of electromagnetic compatibility (emc) fsd requires special precautions regarding emc and needs to be installed and put into service according to the emc information provided in the accompanying documents fsd complies with international standards for: electromagnetic emissions levels...

  • Page 23

    23 fsd complies with international standards for: electromagnetic immunity levels (1). Fsd is intended for use in the electromagnetic environment specified below; the customer or the user of fsd should assure that it is used in such an environment. Immunity test iec 60601-1-2 test level compliance l...

  • Page 24

    24 fsd complies with international standards for: electromagnetic immunity levels (2). Fsd is intended for use in the electromagnetic environment specified below. The customer or the user of the fsd should assure that it is used in such an environment. Immunity test iec 60601-1-2 test level complian...

  • Page 25

    25 recommended separation distances between: portable and mobile rf communications equipment and fsd fsd is intended for use in an electromagnetic environment in which radiated rf disturbances are controlled. The customer or the user of t fsd can help prevent electromagnetic interference by maintain...

  • Page 26

    26 electrical safety degree of protection against ingress water: ordinary this device is not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide technical specifications light source: pulsed light technology: lhe ® (light and heat energy) pulse...

  • Page 27

    27 operation conditions temperature 5ºc 30ºc humidity 30%rh 80%rh transport & storage temperature -20ºc 80ºc humidity 0%rh 95%rh atmospheric pressure 0.1 atm 1.5 atm.

  • Page 28: Ip22

    28 labels this section describes the labels affixed to the fsd plus it is recommended that users review the meaning of these labels for everyday usage and in case any details are needed for service the table below briefly reviews a number of internationally recognized symbols that are found on the...

  • Page 29

    29 in addition, these stickers are found on the main unit and lua’s these include serial numbers of the system parts and some usage warnings label location located at the bottom of the system, this label includes manufacturer’s details, voltage information and the system’s serial number. Located o...

  • Page 30: 9.  Service Information

    30 9. Service information in case you need service, contact radiancy do not attempt to service the unit yourself this will void your warranty radiancy inc. 40 ramland road south, suite 10 orangeburg, ny 10962, usa toll free number: 888-661-2220 tel: 1-845-398-1647 fax: 1-845-398-1648 info@radianc...

  • Page 31

    31 fsd plus - facial skincare device warranty card: user information: system details: name: serial number: street: purchase date: city: comments: state/province: country: zip code: tel: fax: mobile: e-mail: was the system received without visible external damage? Yes no please describe: did the sys...

  • Page 32

    Lit -00103/ rev a00/ mar ch 2013 smart skin solutions.