Radwin 5000 SCB JET Series User Manual

Manual is about: FOR SMALL CELL BACKHAUL

Summary of 5000 SCB JET Series

  • Page 1

    User manual radwin 5000 scb jet for small cell backhaul release 4.2.

  • Page 2: Table of Contents

    Radwin 5000 scb jet user manual release 4.2 i table of contents part 1: installation chapter 1: about this user manual 1.1 manual structure ................................................................................................................1-1 1.2 customer support ..........................

  • Page 3

    Radwin 5000 scb jet user manual release 4.2 ii 8.3 advanced link configuration ............................................................................................8-17 8.4 logging on to the rt-b(hsu) over the air......................................................................... 8-25 8...

  • Page 4

    Radwin 5000 scb jet user manual release 4.2 iii 13.12 where has my hsu gone?...........................................................................................13-27 chapter 14: managing the sector 14.1 scope of this chapter .......................................................................

  • Page 5

    Radwin 5000 scb jet user manual release 4.2 iv part 5: advanced installation chapter 21: vlan functionality 21.1 vlan tagging - overview ................................................................................................21-1 21.2 scope of this chapter ......................................

  • Page 6

    Radwin 5000 scb jet user manual release 4.2 v appendix c: model variants appendix d: laboratory installation d.1 about scb jet laboratory units ..........................................................................................D-1 d.1 installing radwin 5000 scb jet in a laboratory ..............

  • Page 7: List of Tables

    Radwin 5000 scb jet user manual release 4.2 vi list of tables t able 1-1 u ser m anual - g eneral layout ..........................................................................1-1 t able 4-1 h ardware i nstallation w orkflow : c hecklist ....................................................4-5 t a...

  • Page 8

    Radwin 5000 scb jet user manual release 4.2 vii t able 28-1 l ist of w i f i ssid s and ip a ddresses ................................................................28-1 t able a-1 t erminology ......................................................................................................A-1...

  • Page 9

    Part 1: installation release 4.2.

  • Page 10: 1.1.1 Notifications

    Radwin 5000 scb jet user manual release 4.2 1-1 chapter 1: about this user manual 1.1 manual structure this user manual is divided into seven functionally distinct sections reflecting the activities required to set up a radwin 5000 scb jet sector. The division is shown in the following table: 1.1.1 ...

  • Page 11

    Radwin 5000 scb jet user manual release 4.2 1-2 customer support about this user manual 1.2 customer support customer support for this product can be obtained by contacting support@radwin.Com . For additional information, contact the radwin distributor nearest to you or one of radwin's offices world...

  • Page 12

    Radwin 5000 scb jet user manual release 4.2 2-1 chapter 2: introduction 2.1 welcome to radwin 5000 scb jet! The radwin 5000 scb jet series offer high performance point-to-point (ptp) radio links and point-to-multipoint (ptmp) radio sectors. They provide the highest capacity and spectrum efficiency a...

  • Page 13: 2.1.3 Product Highlights

    Radwin 5000 scb jet user manual release 4.2 2-2 product highlights introduction • secured shell access (see configuration with telnet (non-secured and ssh) ), as well as secured ftp • gps-based hub site synchronization improvement (see transmission phase shift ) • a 2nd lan port display (see prefere...

  • Page 14

    Radwin 5000 scb jet user manual release 4.2 2-3 components of a radwin 5000 scb jet link or sector introduction 2.2 components of a radwin 5000 scb jet link or sector 2.2.1 major components of a ptmp sector a radwin 5000 scb jet point-to-multippoint sector consists of an hbs communicating with up to...

  • Page 15: 2.2.3 Accessories

    Radwin 5000 scb jet user manual release 4.2 2-4 major components of a ptp link introduction 2.2.2 major components of a ptp link a radwin 5000 scb jet point-to-point link consists of a pair of outdoor radio transceivers units (odus) using a mimo 2x2/3x3, ofdm smart beam-forming integrated antenna. T...

  • Page 16: 3.1.1 Overview

    Radwin 5000 scb jet user manual release 4.2 3-1 chapter 3: site survey 3.1 planning the sector or link sites 3.1.1 overview this chapter relates primarily to planning sector sites. For practical purposes, a link site survey may be treated as a sector site survey for one hsu. Obviously the numbers wi...

  • Page 17: 3.2.2 Recommended Equipment

    Radwin 5000 scb jet user manual release 4.2 3-2 recommended equipment site survey 3.2.2 recommended equipment stage 1: preliminary survey • topological map of the area • urban map of the area • compass stage 2: physical survey • 100 meter tape measure • ohmmeter, to check ground connection • binocul...

  • Page 18

    Radwin 5000 scb jet user manual release 4.2 3-3 stage 2: physical survey site survey 5. Determine and record the compass bearings between hbs and the hsus, relative to north. 6. If there are obstructions between the two sites, calculate the fresnel zone 7. If the sites chosen do not meet requirement...

  • Page 19

    Radwin 5000 scb jet user manual release 4.2 3-4 additional outdoor site requirements site survey 7. Determine the ground and lightning connection points of the installation. The odu and poe must both be grounded. 8. Using the ohmmeter, measure and record the resistance of the required installation t...

  • Page 20

    Radwin 5000 scb jet user manual release 4.2 3-5 additional tools and facilities site survey • if one or more co-located units are not radwin units, ensure that there is a physical separation of at least three meters between a radwin unit and any other co-located radio on the site. • use the largest ...

  • Page 21: 4.3.1 Radio Units

    Radwin 5000 scb jet user manual release 4.2 4-1 chapter 4: hardware installation 4.1 overview this chapter describes the hardware installation of a radwin 5000 scb jet unit in accordance with the prior planning as set out in site survey . 4.2 goals after you have completed the steps in this chapter,...

  • Page 22

    Radwin 5000 scb jet user manual release 4.2 4-2 power over ethernet (poe) devices hardware installation • one hbs/hsu - see figure below for front and rear view. (both the hbs and hsu have the same form factor) figure 4-1: hbs/hsu form factor • an hbs/hsu mounting kit • a self-adhesive label showing...

  • Page 23: 4.3.3 Accessories

    Radwin 5000 scb jet user manual release 4.2 4-3 accessories hardware installation outdoor poe the outdoor (ruggedized) poe device may be used for both the hbs and the hsus. Both ac and dc models are available. Figure 4-3: ruggedized outdoor poe devices 4.3.3 accessories lightning protector unit (lpu...

  • Page 24: 4.4.1 Site Survey

    Radwin 5000 scb jet user manual release 4.2 4-4 preparations before you start hardware installation ethernet cable repeater the radwin ethernet repeater enables you to extend the poe-to-odu cable beyond the 100m limit (but no more than 200m): figure 4-5: radwin ethernet repeater 4.4 preparations bef...

  • Page 25

    Radwin 5000 scb jet user manual release 4.2 4-5 hardware installation procedure hardware installation • cable ties • sealing material • waterproofing tape such as scotch 23 tape ¾” wide, from 3m to ensure ip-67 compli- ant protection against water and dust • odu grounding cable 10 awg • odu-poe cabl...

  • Page 26

    Radwin 5000 scb jet user manual release 4.2 4-6 step 2: mount the hbs/hsu hardware installation 2. Check that everything listed on the included bill of materials or pro-forma invoice is present. 3. If any item is missing, contact customer service. 4. Do not dispose of the packaging until the unit is...

  • Page 27

    Radwin 5000 scb jet user manual release 4.2 4-7 step 2: mount the hbs/hsu hardware installation figure 4-18 for mounting on a thin pole) 11.Place this “unit” on the pole where you want to mount the odu. Once it is in place, rotate the pole clamp as shown, then tighten both bolts. Figure 4-11: mounti...

  • Page 28

    Radwin 5000 scb jet user manual release 4.2 4-8 step 2: mount the hbs/hsu hardware installation figure 4-12: radwin 5000 scb jet on a vertical pole figure 4-13: radwin 5000 scb jet on a horizontal pole.

  • Page 29

    Radwin 5000 scb jet user manual release 4.2 4-9 step 2: mount the hbs/hsu hardware installation when mounting an odu on a wall, the pole clamp is not needed, as shown: when mounting on a thin pole, position the pole clamp as shown in the following figures: figure 4-14: mounting an odu on a wall figu...

  • Page 30: Grounding Lug

    Radwin 5000 scb jet user manual release 4.2 4-10 step 3: ground the hbs/hsu hardware installation 12.Place this “unit” on the pole where you want to mount the odu. Once it is in place, rotate the pole clamp as shown, then tighten both bolts. 4.5.3 step 3: ground the hbs/hsu there is a grounding lug ...

  • Page 31

    Radwin 5000 scb jet user manual release 4.2 4-11 step 4: install a poe device hardware installation 4.5.4 step 4: install a poe device • indoor poe: strap the poe into a network equipment rack using plastic ties, or place it on a tray or table-top • outdoor poe: mount this poe using the supplied mou...

  • Page 32

    Radwin 5000 scb jet user manual release 4.2 4-12 step 5: mount the lightning protection units hardware installation for any type of idu-odu connection, lightning protection units (lpus) are installed in pairs, as shown in figure 4-21 : figure 4-21: basic use of lightning protector units the lpu has ...

  • Page 33

    Radwin 5000 scb jet user manual release 4.2 4-13 step 5: mount the lightning protection units hardware installation is a slot for the metal tie when installed on a pole, as shown in figure 4-22 and figure 4-23 : to install an lpu on a pole: 1. Choose a location as close as possible to the odu. 2. In...

  • Page 34

    Radwin 5000 scb jet user manual release 4.2 4-14 step 5: mount the lightning protection units hardware installation 7. Tighten the cable glands around the cat-5e cables as shown in figure 4-26 . 8. Route one cat-5e up to the odu, and the other down to the idu or poe (via the lower lpu). An lpu insta...

  • Page 35

    Radwin 5000 scb jet user manual release 4.2 4-15 step 6: add supplemental waterproofing hardware installation 2. Attach the lpu to the wall using wood or masonry screws (not included), via the holes as shown in figure 4-28 . 3. Connect the left screw (where the grounding lug was located) to a ground...

  • Page 36

    Radwin 5000 scb jet user manual release 4.2 4-16 step 7: connect the hbs/hsu to the poe device hardware installation figure 4-29: exposing the tacky side of the sealing tape 3. After connecting a cable to a unit, tighten the cable gland cap firmly and use the insulation tape to fully cover the cable...

  • Page 37

    Radwin 5000 scb jet user manual release 4.2 5-1 chapter 5: radwin manager setup 5.1 in this chapter we show you how to install the radwin manager software on your managing pc, and connect it to an operating hbs. In addition, we also show how to switch the base station (default, ptp) to ptmp mode. Yo...

  • Page 38

    Radwin 5000 scb jet user manual release 4.2 5-2 installing the radwin manager application radwin manager setup 5.2 installing the radwin manager application 5.2.1 minimum system requirements the radwin manager application can be downloaded from the radwin ltd. Website. Operating system specific pc r...

  • Page 39

    Radwin 5000 scb jet user manual release 4.2 5-3 verify connectivity to an hbs radwin manager setup for our configured demonstration system we use the configured ip address: ping 10.104.50.200 leading to this: figure 5-1: pinging the base station - ipv4 under ipv6. The ping for the demonstration syst...

  • Page 41

    Radwin 5000 scb jet user manual release 4.2 5-5 log on to the hbs via a server (optional) radwin manager setup figure 5-6: log on window showing the user types 4. Choose a user type. There are three: • an operator can install and configure the sector. • an installer can, in addition to functioning a...

  • Page 42

    Radwin 5000 scb jet user manual release 4.2 5-6 log on to the hbs via a server (optional) radwin manager setup figure 5-7: log on window showing snmp settings. You may choose the snmp version. If your firewall blocks snmpv3 messages for security reasons, them use snmpv1. If you are using trap authen...

  • Page 43: 5.6.1 Unsupported Device

    Radwin 5000 scb jet user manual release 4.2 5-7 log-on errors and cautions radwin manager setup 5.6 log-on errors and cautions 5.6.1 unsupported device attempting to connect to an unsupported device on an otherwise valid ip address (for example, a lan printer) will result in the following error mess...

  • Page 44: Passwords

    Radwin 5000 scb jet user manual release 4.2 5-8 invalid read/write community string or snmpv3 passwords radwin manager setup figure 5-10: invalid user type or password 5.6.4 invalid read/write community string or snmpv3 passwords this will result in the same message as shown in figure 5-9 . To deal ...

  • Page 45: 5.7.1 Point to Point

    Radwin 5000 scb jet user manual release 4.2 5-9 point to point radwin manager setup 5.7.1 point to point figure 5-11: ptp link display.

  • Page 46: 5.7.2 Point to Multipoint

    Radwin 5000 scb jet user manual release 4.2 5-10 point to multipoint radwin manager setup 5.7.2 point to multipoint figure 5-12: ptmp sector display 5.8 choosing the operating mode - ptp or ptmp 5.8.1 choosing ptp mode the hbs for a new link or sector, “out of the box” from the factory is configured...

  • Page 47: 5.8.2 Choosing Ptmp Mode

    Radwin 5000 scb jet user manual release 4.2 5-11 choosing ptmp mode radwin manager setup 5.8.2 choosing ptmp mode to prepare the hbs for ptmp use: 1. Log on to thehbs. Here is the initial situation: 2. Click the link configuration tab. The link configuration dialog box will appear: make sure the hsu...

  • Page 48

    Radwin 5000 scb jet user manual release 4.2 5-12 choosing ptmp mode radwin manager setup 3. Click the air interface tab. 4. You may have to click the arrow on the advanced window to open it up. The above figure on the right shows the automatic channel selection enabled. 5. Click the switch to multip...

  • Page 49

    Radwin 5000 scb jet user manual release 4.2 5-13 reverting from ptmp mode to ptp mode radwin manager setup 7. Following alignment and commissioning you may continue to installing the sector . 5.8.3 reverting from ptmp mode to ptp mode 1. Deregister all the hsus in the sector (see deregister rt-b(hsu...

  • Page 50: 5.9.1 Scope of Preferences

    Radwin 5000 scb jet user manual release 4.2 5-14 setting preferences radwin manager setup 4. Click the advanced button, followed by the switch to single hsu mode button. 5.9 setting preferences 5.9.1 scope of preferences the preferences tab at the top of the radwin manager relates to the managing co...

  • Page 51: 5.9.2 Preferences: Monitor

    Radwin 5000 scb jet user manual release 4.2 5-15 preferences: monitor radwin manager setup 5.9.2 preferences: monitor figure 5-13: monitor preferences - hbs figure 5-14: monitor preferences - hsu or hbs ptp mode.

  • Page 52

    Radwin 5000 scb jet user manual release 4.2 5-16 preferences: monitor radwin manager setup file: place a checkmark here to save traffic and identification information to the monitor file. The content of the monitor file is described in detail in ptp: monitoring and diagnostics . Click the explorer b...

  • Page 53: 5.9.3 Preferences: Events

    Radwin 5000 scb jet user manual release 4.2 5-17 preferences: events radwin manager setup 5.9.3 preferences: events critical ... Info:choose your own color coding for the recent event display (see ptp: monitoring and diagnostics ). Reset settings:restore the color coding to the default values. Backg...

  • Page 54: 5.9.4 Preferences: Advanced

    Radwin 5000 scb jet user manual release 4.2 5-18 preferences: advanced radwin manager setup 5.9.4 preferences: advanced figure 5-15: advanced preferences change password: you may change your log-on password here from the default value. Restore alerts:many alert messages in the radwin manager have an...

  • Page 55

    Radwin 5000 scb jet user manual release 4.2 5-19 preferences: advanced radwin manager setup place a checkmark here to enable an extended rss view. Instead of a single rss bar and value for the unit, a separate rss bar and value is shown for each antenna. For example, with this box checked, for ptp, ...

  • Page 56

    Radwin 5000 scb jet user manual release 4.2 5-20 preferences: advanced radwin manager setup figure 5-16: rss extended view - left, on. Right, off enable tx/rx extended view: place a checkmark here to enable viewing the rx and tx rate of each lan line attached to the unit (if relevant). Lan1 correspo...

  • Page 57

    Radwin 5000 scb jet user manual release 4.2 5-21 preferences: advanced radwin manager setup for a ptmp connection, with this box checked the hsu display looks like this: for a ptmp connection, with this box unchecked the hsu display looks like this:.

  • Page 58

    Radwin 5000 scb jet user manual release 4.2 5-22 preferences: advanced radwin manager setup enable unicode in text fields: this allows you to write non-standard text in the various fields you use. We do not recommend this because it would be difficult or impossible to coordinate with systems and equ...

  • Page 59

    Radwin 5000 scb jet user manual release 4.2 6-1 chapter 6: alignment and commissioning 6.1 overview this chapter describes how to align the hsu with its hbs, then carry out a throughput test (commissioning), using the wintouch application. At the hsu site, using wintouch, you will follow its instruc...

  • Page 60

    Radwin 5000 scb jet user manual release 4.2 6-2 alignment procedure alignment and commissioning control panel -> open network and sharing center -> change adapter settings -> double-click on local area connection -> properties -> select internet protocol version 4 (tcp/ipv4) -> properties -> use the...

  • Page 61

    Radwin 5000 scb jet user manual release 4.2 6-3 alignment procedure alignment and commissioning • you may have to open the radwin manager to verify that the hsu is not registered. For instructions on how to verify this, see registering an hsu for service on page 13- 21 . 2. Run the wintouch executab...