SAFERA PCU6.1-F Installation Manual - page 9
17
16
Installation - Step 2/2
Mount the Sensor unit
Ⓐ
Mount the sensor unit
Ⓐ
• Use the cleaning pad to remove grease and dirt from the surface before attach-
ing the sensor unit
Ⓐ
with the adhesive tape.
• Mount the sensor unit
Ⓐ
according to the mounting option A, B or C shown on the
right: if the cooker width is 70 - 90 cm, lower the alarm limit one step compared to
the recommended setting (see chapter 4.1.).
3
Mounting option A:
wall-mount
Mounting option B and C:
cooker hood
2) To install outside of the default in-
stallation height 55 - 65 cm, adjust the
alarm limit according to chapter 4.
1) To install outside of the default in-
stallation height 50 - 60 cm, adjust the
alarm limit according to chapter 4.
Check the working order
4
1. Turn on one cooker plate with maxi-
mum power. With an induction cook-
er use a suitable dish.
2. Press and hold the OK-button
❸
for
5 seconds: the system should cut off
the cooker power.
3. Test that none of the cooker plates
and oven (if connected to the stove
guard) are operable: if ok, switch off
cooker and oven.
4. Return the cooker power by pressing
the OK-button
❸
: the Indicator Light
❹
should blink green once. If not,
see Troubleshooting in chapter 3.
ѧ
HINT
Airis will automatically recognize the
cooker type during cooking to mini-
mize false alarms: to speed up the
auto-recognition, you may manually
select the cooker type according to
the chapter 4.3.
Sensor
❻
direction.
⚐
ATTENTION
Ensure the correct sensor direction:
both sensors
❻
should look towards
the cooker. The sensor unit
Ⓐ
should
be mounted on the centerline of the
cooker.
Install the batteries
⚐
ATTENTION
Check the correct position of the
batteries marked on the bottom of
the battery case.
2
Remove the protection
strip from the adhesive
tape
Place the batteries in the sensor unit
Ⓐ
which should beep twice to indicate
that the wireless connection to the Pow-
er Control Unit
Ⓒ
was successful.
5. Working order checked successfully:
Date Installer
50 - 60 cm
max.
15 cm
max.
15 cm
A
55 - 65 cm
(45 - 95 cm)
2
(45 - 60 cm)
1
B
C
+8°
-8°
+8°
-8°
1