Saferhomee HB-G100 Series User Manual

Manual is about: Intelligent Burglar Alarm Host

Summary of HB-G100 Series

  • Page 1

    Hb-g100 hb-g100 hb-g100 hb-g100 series series series series user user user user manual manual manual manual for for for for intelligent intelligent intelligent intelligent burglar burglar burglar burglar alarm alarm alarm alarm host host host host ningbo ningbo ningbo ningbo saferhome saferhome safe...

  • Page 2: Table

    1 table table table table of of of of contents contents contents contents i. Definition............................................................................2 ii. Operating precautions..........................................................4 iii. Main characteristics and functions..............

  • Page 3: Introduction

    2 introduction introduction introduction introduction hb-g100 series intelligent burglar alarm host is an intelligent long-range wireless transmission alarm system. This system adopts advanced microprocessor as control core and has voice prompts, easy to install and operate. It can learn codes of 5 ...

  • Page 4

    3 zone) in which the host can receive shielded signals, and can not receive any alarm signal temporarily. Full full full full arm arm arm arm it refers to the state in which all alarm detectors in full arming zone or part arming zone enter into alert state. Partial partial partial partial arm arm ar...

  • Page 5: II.

    4 ii. Ii. Ii. Ii. Operating operating operating operating precautions precautions precautions precautions please carefully read this user manual and pay more attention to labels and directions on the alarm host before operation. Check whether all wire connections are correct and then turn the host...

  • Page 6

    5 security threats and 2 groups of telephone numbers of the alarm receiving centre. The telephone numbers of the alarm receiving centre must be fixed telephone numbers, which can be dialled preferably when an alarm is triggered under telephone alarm mode. alarm or failure information can be displa...

  • Page 7: IV.

    6 iv. Iv. Iv. Iv. Name name name name and and and and usage usage usage usage of of of of main main main main components components components components keyboard keyboard keyboard keyboard panel panel panel panel 1 111、 、 、 、keyboard keyboard keyboard keyboard 1) “run” indicator: “run” indicator bl...

  • Page 8

    7 host gets ready for receiving alarm signals from partially armed zones within the system and giving out alarm. 6) “record” indicator: in set-up mode, users can prerecord a voice message to play back at the time when a call is answered to respond to an alarm. When a voice message is recorded, “reco...

  • Page 9: 2、installation

    8 minute. 15) “emergency zone” indicator: “emergency zone” indicator will light up only when set-up is performed for an emergency zone. Once emergency zone set-up is completed, the indicator is not turned on even when an alarm occurs. 16) “doorbell zone” indicator: “doorbell zone” indicator will lig...

  • Page 10

    9 installation installation installation installation & & & & wiring wiring wiring wiring diagram diagram diagram diagram of of of of engineering engineering engineering engineering host host host host.

  • Page 11

    10 ① mains supply input: the alarm host adopts ac 220v±10% 50hz input, and the input terminal is connected in series with a 0.5a fusion tube. ② external backup battery input: the host adopts dc12v7ah external backup battery input. ③ external siren output: a dc 12v siren (current: the alarm host. ④ l...

  • Page 12: System

    11 connection principle: the normally open detector shall be connected in parallel with a 2.7kΩ resistor, while the normally closed detector shall be connected in series with a 2.7kΩ resistor. Mixed connection of normally open detectors and normally closed detectors v. V. V. V. System system system ...

  • Page 13: VI.

    12 from damaged by mouse or other rodents. ④ the type and specification of detectors and cables in each defense zone should be labeled on construction drawings (the usage of each wire within a cable shall be marked). ⑤ all construction drawings should be archived for facilitating maintenance of the ...

  • Page 14

    13 intended for the host, and defense zones 000-007 are mixed wired/wireless defense zones in which it is not recommended to install wireless detectors. (i) (i) (i) (i) add/delete add/delete add/delete add/delete remote remote remote remote controllers controllers controllers controllers the host ca...

  • Page 15

    14 panel of the host. “disarm” key: press “disarm” key to disarm the host (except for shielded zone, doorbell zone and emergency zone). The function of “disarm” key is the same as that of f3 shortcut key on the keyboard panel of the host. Emergency key: press emergency key to activate emergency alar...

  • Page 16

    15 the first four steps of deleting a remote controller are the same as those of adding a remote controller. Step 5: enter 19 and # after 19, and then the host gives out a voice prompt “delete all remote controllers”. Step 6: press “#” key again, and then the host gives out a voice prompt “ding”, wh...

  • Page 17

    16 【note】 a. Detectors (numbered 000-119) shall be added in accordance with the same procedure. B. To let the host learn codes of detectors continuously, enter 011 and # 11 after the host completes learning the first detector, and then activate the next detector to let the host learn the code of the...

  • Page 18: Precautions

    17 those of adding a detector, so please refer to the first four steps of the procedure for adding a detector. Step 5: enter “010” and “*”, and then the host will give out a voice prompt “now, the host is serving a fully armed zone. Please enter the attribute of the defense zone”(the attribute of al...

  • Page 19: Reasons

    18 reasons reasons reasons reasons for for for for failing failing failing failing to to to to learn learn learn learn codes codes codes codes coding redundancy: if the wireless code currently required to be learned by the alarm host has exited in the alarm host, that is, this code has been learned ...

  • Page 20

    19 6) dialling times: 5 7) siren duration: 30 minutes 8) leaving time: 5 seconds 9) entry time: 0 second 10) ringing times set via remote control: 9 times 11) defense zone attribute: full arm 3. Detailed programming operation of alarm host all programming operations below shall be performed in set-u...

  • Page 21

    20 ② command function: on-site alarm mode command grammar: 3# function description: this command enables the host to work under on-site alarm mode in which the host can not dial any telephone and check outside line, as well as to cancel all alarm information. Operating steps: “###”(please enter the ...

  • Page 22

    21 again)+“bbbbbb#”. If you have forgotten the preset password indiscreetly, you shall contact our customer service centre or your local distributor for help. 5) command function: modify user password command grammar: 9 # a a a a a a # b b b b b b # b b b b b b #. “a a a a a a” is an old 6-digit use...

  • Page 23

    22 step 3: enter “10” (10 represents informed phone number) and “#”, and then the host will give out a voice prompt “please enter an informed phone number”. Step 4: enter a preset phone number and “#” to finish the set-up. (if the input phone number is wrong, delete it and then enter a correct phone...

  • Page 24

    23 for the first two steps, please refer to the above mentioned procedure in set mode. Step 3: enter 19 and #, and then the host will warn users through voice message to delete all informed phone numbers”. Step 4: press “#” key again, and then the host will indicate a remote controller has has has h...

  • Page 25

    24 press 2 5 # to select the medium on-site alarm volume; press 2 6 # to select the large on-site alarm volume press 2 7 # to select the maximum on-site alarm volume operating steps: “###”(please enter the preset password) +“112233#”(the host enters into adjusting mode)+“27#”(for trial listening of ...

  • Page 26

    25 ② command command command command function: function: function: function: audition audition audition audition the the the the record record record record command grammar: 3 1 # function description: press 3 1 #, and then 2-3 seconds of record will be played from the built-in speaker of the host. ...

  • Page 27

    26 ② command function: set leaving time command grammar: 3 5 # d d # function description: “d d” refers to leaving time, also called delayed arm time and must be a 2-digit number (00-99 minutes). Within the leaving period of time, the alarm host gives out a short “beep” sound every 1 second, and you...

  • Page 28: Viii.

    27 ⑤ command function: set dialling times command grammar: 3 8 # d d # function description: “d d” refers to dialing times (01-99), namely how many times the host dials phone numbers according to a list of preset phone numbers. Note: this set-up does not apply when the host dials phone numbers of th...

  • Page 29

    28 2. Modify alarm mode and arm/disarm in set mode enter # # # a a a a a a # to enter into set-up mode and modify alarm mode. ① arm the host in phone alarm mode enter 1 # to arm in phone alarm mode and exit set-up mode. ② arm in on-site alarm mode enter 3 # to arm in on-site alarm mode and exit set-...

  • Page 30

    29 arm/disarm methods in "arm/disarm operation" to arm the alarm host and to ensure the system is on alert. The alarm host will automatically alarm according to the pre-set alarm procedure as soon as someone breaks into a defense area. Emergency alarm (or help) if any emergency circumstance such as ...

  • Page 31: Ix.

    30 phone numbers. 4. 4. 4. 4. Remote remote remote remote set-up set-up set-up set-up call the phone numbers pre-set for the user alarm host through fixed phone or mobile phone in other areas, and then the user alarm host will automatically pick up the phone after receiving several rings (program de...

  • Page 32: X. Standard

    31 operating conditions: -10-55℃ relative humidity: 40-70% dial mode: double audio frequency high frequency group level: -7 ±2dbm low frequency group level: -9±2dbm pick-up resistance: ≤300Ω external backup battery: dc12v7ah dimension: 265×260×80(mm) 2. 2. 2. 2. Wireless wireless wireless wireless r...

  • Page 33: Xii.

    32 xii. Xii. Xii. Xii. Failure failure failure failure troubleshooting troubleshooting troubleshooting troubleshooting failure symptom reason failure recovery method “run” indicator does not light up when powered on power plug is not properly connected, or socket has no power check power plug or soc...

  • Page 34: Xiii.

    33 led “power failure” indicator lights up and displays defense zone number. The battery of the detector for this defense zone is damaged. Replace the battery the remote distance of remote control becomes shorter. The voltage of the battery is low. Replace the battery user password is wrong. User pa...

  • Page 35: Alarm

    34 1 1 # # delete the second group of informed phone numbers 1 2 # # delete the third group of informed phone numbers 1 3 # # delete the fourth group of informed phone numbers 1 9 # # delete all phone numbers 2 4 # select small alarm volume 2 5 # select medium alarm volume 2 6 # select large alarm v...

  • Page 36: Warning:

    35 warning: warning: warning: warning: limits limits limits limits of of of of this this this this security security security security system system system system as an advanced hi-tech anti-theft system, although this product can reduce and prevent the occurrence of theft, robbery and fire and thus...

  • Page 37

    36 the alarm center, or other lines are busy, so that alarm information can not be transmitted in time. 8. The alarm system does not alarm when someone intrudes or there is an emergency alarm. The most common reason is that the alarm system does not get properly maintained. Like other electrical equ...