Salter Brecknell B 130 User Manual

Manual is about: Counting Scale

Summary of B 130

  • Page 1

    P/n awt35-500632 issue aa july 2010 model b 130 counting scale user manual.

  • Page 2

    General information and warnings special messages examples of special messages you will see in this manual are defined below. The signal words have specific meanings to alert you to additional information or the relative level of hazard. Danger! This is a danger symbol. Danger means that failure to ...

  • Page 3

    Installation electrical installation pluggable equipment pluggable equipment must be installed near an easily accessible socket outlet. Permanently wired equipment - isolator requirements permanently connected equipment must have a readily accessible disconnect device incorporated in the fixed wirin...

  • Page 4

    Safe handling of equipment with batteries wet conditions under wet conditions, the plug must be connected to the final branch circuit via an appropriate socket / receptacle designed for washdown use. Installations within the usa should use a cover that meets nema 3r specifications as required by the...

  • Page 5

    Cleaning the machine training do not attempt to operate or complete any procedure on a machine unless you have received the appropriate training or read the instruction books. To avoid the risk of rsi (repetitive strain injury), place the machine on a surface which is ergonomically satisfactory to t...

  • Page 7

    2 connect the red wire to the red battery terminal and the black wire to the black battery terminal. Place battery in the compartment with the padding placed as shown and replace the battery cover and tighten the screw. Note: to improve battery life, turn off the scale using the power switch..

  • Page 8: 3.0

    3 3.0 front panel the front panel, shown in figure 1 , consists of three display windows (weight, piece weight, and count), the keypad, nine annunciators and the bubble level window. Figure 1: b130 front panel annunciators annunciators are bright leds next to symbols or text. They appear below the t...

  • Page 9: Key Functions

    4 key functions each of the keys shown in figure 2 is explained below. Figure 2: b 130 keypad 0-9 used for keyboard entry of piece weight, sample size, and upper and lower limit settings. Units lb/kg used to switch displayed weights between kg and lb, and piece weight units between grams and decimal...

  • Page 10: 4.0

    5 4.0 scale operation this section covers the various scale operations, such as weighing, counting, accumulation, etc. Simple weighing 1. Turn the scale on and zero the display, if necessary, by pressing the zero key. Be sure the scale is displaying weight in your preferred unit of measure. Change i...

  • Page 11: General Counting Information

    6 general counting information if there is no piece weight, the scale will not go into count mode. Once a piece weight is established, it remains active until another piece weight is automatically calculated by a sampling process. After counting items, remove them and the display should return to ze...

  • Page 12

    7 4. Press the enter key to accept the keyed in number. (if you make an error in keying in the number, press the clear key to clear the count in the count window and re-key the correct number.)… the scale calculates the weight of each piece (the piece weight) and displays the count in the count wind...

  • Page 13

    8 4. Place the items to be counted on the scale… the total weight, piece weight and count of the items will be shown in the three display windows respectively. 5. Remove the items from the scale and repeat steps 4 and 5 to count items of the same piece weight. 6. Repeat steps 2-5 to count items of a...

  • Page 14: Accumulating Counts

    9 8. Remove the items from the scale and repeat steps 7 and 8 to weigh the next batch of items. Counting with upper and lower limits can be done while using a tare. After you have set the piece weight (step 2 ), place the item to be tared on the scale, press the tare key and continue with counting a...

  • Page 15: 5.0

    10 5. The scale will not accumulate more than 999,999 times, or show an accumulated quantity over 16,777,215. If this occurs the display will show ------. This means over range. When the accumulated quantity is more than the six digit display can show (999999), it will be displayed by alternately fl...

  • Page 16

    11 access to the calibration switch may be sealed with a lead-wire combination on the bottom of the scale. Prior to removing the lead seal, check to see if the test switch is in the correct position by following step 1 below. If you are not allowed access, remove the lead-wire seal. Note: you can ex...

  • Page 17: 6.0

    12 6. When unload is displayed in the piece weight window, it means the scale will confirm the zero point once more. Remove the weight from the scale and after the scale is stable and unit announciator is not flashing. Press the enter key. The scale goes through the start up routine and ends in norm...

  • Page 18: 7.0

    13 7.0 setting the auto-off timer you can set an auto-off timer so that the scale will power down automatically after a period of inactivity. This functions only when the scale is powered by the battery. 1. From normal mode, press and hold the on/off and accu keys at the same time until the scale be...

  • Page 19: 9.0

    14 9.0 displayed messages ¯ ¯ ¯ ¯ ¯ ¯ sca le overloaded - - - - - - too many accumulations or accumulated counts too high _ _ _ _ _ _ weight signal is too small 0¯ ¯ ¯ ¯ ¯ the zero point is too high 0_ _ _ _ _ the zero point is too low eep.Er0 the eeprom can’t be accessed eep.Er1 the parameters in e...

  • Page 20: 10.0 Specifications

    15 10.0 specifications power supply a). 12vdc 500ma output, with positive center, ac adapter b). 6v4a rechargeable lead-acid battery average working current: 120ma when led’s brightness is set to 1 200ma when led’s brightness is set to 2(default) 300ma when led’s brightness is set to 3 note: the led...

  • Page 21

    16.

  • Page 22: Uk and Europe

    Uk and europe salter brecknell weighing p.O, box 9533 smethwick west midlands b66 2te tel: +44 (0) 870 444 6132 fax: +44 (0) 870 010 2241 email: sales@salterbrecknell.Co.Uk web site: www.Averyweigh-tronix.Com usa salter brecknell weighing products usa 1000 armstrong drive fairmont, mn 56031 toll fre...