Salter Brecknell C3225 User Manual

Manual is about: Checkweighing scale

Summary of C3225

  • Page 1

    C3225 checkweighing scale user guide multi-lingual 76103-555 issue 0 14.03.2002.

  • Page 2

    C3225 checkweigher - user guide © salter brecknell weighing 2002. All rights reserved. The information contained herein is the property of salter brecknell weighing and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other ...

  • Page 3: Table Of Contents

    Table of contents c3225 checkweigher - user guide i table of contents section page warnings 1 safe installation 1 safe use 1 cleaning the machine 1 1 display and keypad 5 2 latitude compensation 6 3 basic operation 7 3.1 power on/power off 7 3.2 weighing 8 3.3 tare 9 3.4 check weighing 10 3.5 settin...

  • Page 4: Battery Charging

    Table of contents ii c3225 checkweigher - user guide 7 battery charging 31 appendix a 33 latitude compensation maps 33.

  • Page 5: Warnings

    Warnings c3225 checkweigher - user guide 1 warnings safe installation caution: the mains lead must be connected to a supply outlet with a protective earth contact. The electrical supply at the socket outlet must provide over current protection of an appropriate rating. Pluggable equipment must be in...

  • Page 6: Declaration Of Conformity

    Declaration of conformity manufacturer salter brecknell type c3225 corresponds to the requirements of the following ec directives: emc directive emc 89/336/eec low voltage directive lvd 73/23/eec the applicable harmonised standards are: en60950, en50081–1, en50082–1 a copy of the original signed dec...

  • Page 7

    C3225 checkweigher - user guide 3 electromagnetic compatibility statement for north america this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmfu...

  • Page 8

    4 c3225 checkweigher - user guide.

  • Page 9: Display And Keypad

    Display and keypad - 1 c3225 checkweigher - user guide 5 1 display and keypad 1. Display 2. Low battery led 3. Under weight led 4. Over weight led 5. Weight in range led 6. Target key 7. Tare key 8. On/off / zero key 9. Units select key 6 1 2 3 4 5 7 8 9.

  • Page 10: Latitude Compensation

    2 - latitude compensation 6 c3225 checkweigher - user guide 2 latitude compensation the scale automatically compensates for variance in the earths gravitational pull, at different locations around the world. When the scale is powered up for the first time, you are required to enter a latitude band f...

  • Page 11: Basic Operation

    Basic operation - 3 c3225 checkweigher - user guide 7 3 basic operation 3.1 power on/power off to switch the scale on to switch the scale off press and hold for 5 seconds. 1rwh 7klvixqfwlrqfdqdovrehshuiruphgzlwkwkhirrwvzlwfk vhh ´)rrwshgdorshudwlrqµrqsdjh 3 3 3 3 3 2 2 2 2 2 + + + + + 4 .... Example...

  • Page 12: 3.2

    3 - basic operation 8 c3225 checkweigher - user guide 3.2 weighing basic weighing 1. Switch on the scale. 2. Apply commodity. 3. Take reading. 4. Remove commodity. Selecting units press to cycle between g, lb and oz. Zeroing the scale press 4 example displays +,-./ 4.

  • Page 13: 3.3

    Basic operation - 3 c3225 checkweigher - user guide 9 3.3 tare 1. Ensure scale reads zero, press zero if necessary. 2. Apply container. 3. Press tare. 4. Apply commodity. 5. Take reading. 6. Remove commodity and container. 7. Press tare to cancel. 1rwh 7klvixqfwlrqfdqdovrehshuiruphgzlwkwkhirrwvzlwfk...

  • Page 14: 3.4

    3 - basic operation 10 c3225 checkweigher - user guide 3.4 check weighing 1. Switch on scale. See 3.1 - ’power on/ power off’ . 2. Press target to toggle between checkweigh/non checkweigh modes. 3. If required, apply container and tare. See 3.3 - ’tare’ . 4. Gradually apply commodity, whilst checkin...

  • Page 15: 3.5

    Basic operation - 3 c3225 checkweigher - user guide 11 3.5 setting checkweigh limits 1. Press and hold target. Set upper limit 2. Press the tare key to cycle through the display digits, press units to increment the value. 4444 example displays 4444 +444 +444 +,44 +,44 +,-4 +,-4 +,-..

  • Page 16

    3 - basic operation 12 c3225 checkweigher - user guide 3. Press target to accept. 4. Set lower check weigh limit in the same way as shown in steps to 3. 5. The scale will then return to checkweigh / normal weighing mode, as appropriate. 1rwh 7khxqlwvxvhgwrvhwwkhxsshudqgorzhufkhfnzhljk olplwvduhwkhvd...

  • Page 17: Main Configuration Menu

    Main configuration menu - 4 c3225 checkweigher - user guide 13 4 main configuration menu 4.1 overview the following options are available from the main configuration menu: function description options cal calibration see “cal - calibration” on page 15 g gram mode on off oz ounce mode on off lb pound...

  • Page 18: 4.2

    4 - main configuration menu 14 c3225 checkweigher - user guide 4.2 navigating the configuration menu to access configuration mode press and hold for 5 seconds. To navigate configuration mode 1. Press tare to cycle through functions. 2. Press units to access function. 3. Press tare to cycle through o...

  • Page 19: 4.3

    Main configuration menu - 4 c3225 checkweigher - user guide 15 4.3 configuration options cal - calibration 1. Enter configuration mode. Press and hold for 5 seconds. 2. Press units key to start calibration process. 3. Select origin zone. 1rwh 7khruljlq]rqhuhsuhvhqwvwkhodwlwxgh riwkhorfdwlrqzkhuhwkhv...

  • Page 20

    4 - main configuration menu 16 c3225 checkweigher - user guide 5. Press zero/on/off. 6. Apply appropriate calibration weight. 7. Press zero/on/off key. 8. Select the d-zone. 1rwh 7khg]rqhuhsuhvhqwvwkhodwlwxghri wkhorfdwlrqzkhuhwkhvfdohzlooehxvhg 6hh ·$sshqgl[$· ·/dwlwxghfrpshqvdwlrq pdsv· ,iwkhg]rqh...

  • Page 21

    Main configuration menu - 4 c3225 checkweigher - user guide 17 g - gram mode to enable or disable grams, as an available weighing unit. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select gram mode. 3. Press units to access function. 4. Press tare to cycle through options. 5. Press ...

  • Page 22

    4 - main configuration menu 18 c3225 checkweigher - user guide oz - ounce mode to enable or disable ounces, as an available weighing unit. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select ounce mode. 3. See “g - gram mode” on page 17 for selection of ‘on/off’. Lb - pound mode to ...

  • Page 23

    Main configuration menu - 4 c3225 checkweigher - user guide 19 wt - calibration weight to set the valid calibration weight. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select calibration weight. 3. Press units to access function. 4. Press tare to cycle through options. 5. Press tar...

  • Page 24

    4 - main configuration menu 20 c3225 checkweigher - user guide gres - gram display division to set the displayed resolution when weighing in grams. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select gres mode. 3. Press units to access function. 4. Press tare to cycle through option...

  • Page 25

    Main configuration menu - 4 c3225 checkweigher - user guide 21 ires - pound display division to set the displayed resolution when weighing in pounds. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select ires mode. 3. Press units to access function. 4. Press tare to cycle through opti...

  • Page 26

    4 - main configuration menu 22 c3225 checkweigher - user guide def - default settings to return the scale to its factory default settings. For information on navigating and selecting configuration options see “navigating the configuration menu” on page 14 . Factory default settings capacity setting ...

  • Page 27

    Main configuration menu - 4 c3225 checkweigher - user guide 23 trad - set to trade legal to set the scale as legal for trade, and prevent alterations to the configuration. For information on navigating and selecting configuration options see “navigating the configuration menu” on page 14 . Caution: ...

  • Page 28

    4 - main configuration menu 24 c3225 checkweigher - user guide end - exit main configuration menu to save and exit from the configuration and return to normal operating mode. 1. Enter configuration mode. Press and hold for 5 seconds. 2. Select end from the available options. 3. Press tare to cycle t...

  • Page 29: 4.4

    Main configuration menu - 4 c3225 checkweigher - user guide 25 4.4 auto off / audio beep auto off auto off is a battery saving feature. When in operation the scale will automatically turn itself off after a set period of inactivity. 1. Enter auto off/audio beep set up. Press and hold for 5 seconds. ...

  • Page 30

    4 - main configuration menu 26 c3225 checkweigher - user guide 5. Press tare to cycle through options. 6. Select end. Press target key to exit. Audio beep the audio beep is used in check weighing mode, to indicate when the weight is within the set limits. Use this option to turn the beeper on or off...

  • Page 31

    Main configuration menu - 4 c3225 checkweigher - user guide 27 2. Press tare to cycle through options. 3. Press units to select beep function. 4. Press tare to cycle through options. 5. Press target to accept and proceed. & # example displays & &.

  • Page 32

    4 - main configuration menu 28 c3225 checkweigher - user guide 6. Press tare to cycle through options. 7. Select end. Press target key to exit. & # example displays # '.

  • Page 33: Error Displays

    Error displays - 5 c3225 checkweigher - user guide 29 5 error displays 5.1 weighing errors under weight display when the weight applied is below the minimum which can be weighed. Over weight display when the weight applied is above the maximum which can be weighed. 5.2 other errors battery low displ...

  • Page 34: Foot Pedal Operation

    6 - foot pedal operation 30 c3225 checkweigher - user guide 6 foot pedal operation switch the scale on switch scale off press and hold for 5 seconds. Tare press with weight on scale. Tare cancel press with no weight on scale. 1rwh )rupruhlqirupdwlrqrqwkhderyhixqfwlrqvvhh ´%dvlf rshudwlrqµrqsdjh.

  • Page 35: Battery Charging

    Battery charging - 7 c3225 checkweigher - user guide 31 7 battery charging re-charging the battery when the battery requires re-charging, the scale will display: to recharge the battery, plug the charger supplied with the scale into the re-charge socket on the base of the unit. Caution: connect the ...

  • Page 36

    7 - battery charging 32 c3225 checkweigher - user guide.

  • Page 37: Appendix A

    Appendix a - latitude compensation maps c3225 checkweigher - user guide 33 appendix a latitude compensation maps europe 2 3 4 5 6 7 8 9 10 58° 55° 52° 49° 46° 43° 40° 37° 61° 1 64 0

  • Page 38

    Appendix a - latitude compensation maps 34 c3225 checkweigher - user guide usa australasia 7 8 9 10 11 12 13 14 28 o 31 o 34 o 37 o 40 o 43 o 46 o seattle san francisco los angeles denver ny philadelphia dallas atlanta houston st. Louis miami boston chicago minneapolis detroit memphis washington ali...

  • Page 40

    The address of your salter brecknell centre is this document contains a general guide only of the product and shall not form part of any contract unless specifically agreed by salter brecknell weighing in writing in each case on the order acknowledgement. The specification of the products described ...