SENSORVISION PRODUCTS IP speedDome Ultra 8 Quick Reference Manual

Manual is about: American Dynamics SpeedDome Optima: Service Manual

Summary of IP speedDome Ultra 8

  • Page 1

    Sensorvision ® systems speeddome q uick r eference g uide part of speeddome installation and service manual, 8000-0518-01, rev. C..

  • Page 2

    Table of contents quick reference guide: part i indoor mounts • hard mount installation .................................................................................................. Q-1 • hard mount w/adj. Bracket installation........................................................................

  • Page 3: Sensormatic

    Sensormatic sensorvision systems sensorvision speeddome q-1 using an s-hook, hang safety chain [d] from a strong ceiling member and, using a second s-hook, attach other end of the chain to the eyebolt. Keep the chain as taut as possible. Tighten both ends of each s-hook. 3. Keep chain as taut as pos...

  • Page 4: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-2 procedure tile ceilings only. Remove the ceiling tile(s) and inspect the ceiling frame. The frame must be capable of withstanding 9kg (20 lbs) of weight and the forces generated as the dome pans and tilts. Important: shipping b...

  • Page 5

    Sensorvision speeddome q-3 keep chain as taut as possible! Close ends of each s-hook! Do not use sprinkler or fire control system securing the safety chain! With its three mounting tabs [g] in the up position, insert the housing into the ceiling hole until the studs in the plate fit through the slot...

  • Page 6: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-4 * u.S. Customary measurements in italics are rounded off. 3. 1. 2. Remove the ceiling tile(s) and inspect the ceiling frame. The frame must be capable of withstanding 9kg (20 lbs) of weight and the forces generated as the dome ...

  • Page 7

    Sensorvision speeddome q-5 4. 5. 6. 7. Feed video and multiconductor cables [m] through one of the two holes in side of the housing and reinstall the adjacent ceiling tile. See chassis installation on page q-8. Set the housing [f] into the ceiling open- ing. For slightly larger openings, see box bel...

  • Page 8: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-6 required parts required parts 6m (20') max [e] [j] [i] [g] [h] [f] [d] 3. Slip the cap [i] onto the pipe, then thread housing [j] onto the pipe. See chassis installation on page q-8. Feed video and multiconductor cables [h] thr...

  • Page 9: Procedure

    Sensorvision speeddome q-7 procedure i-beam attachment . Set the base plate [a] against a suitable ceiling member [b]. Secure the plate using clamps [c] and hardware supplied [d]—see base plate hole-to-hole dimensions, below. Attach the flange [e] using hardware supplied [f]. Base plate hole-to-hole...

  • Page 10: Chassis Installation

    Chassis installation sensormatic sensorvision systems the world leader in loss prevention q-8 required parts required parts required parts required parts description q t y . Part no. Speeddome install kit 2111-0035-01 2111-0034-01 6009-0006 1 1 1 connector, bnc bnc jack nylon cable tie 0351-0377-01 ...

  • Page 11

    Sensorvision speeddome q-9 8. To compensate for accidental jarring during assembly, recalibrate the dome as follows: at the console, call up the dome address number. Once calibrated, which takes about a minute, the dome is ready for use. Installation is complete. Press and hold the fast key. Then—in...

  • Page 12: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-10 0500-3499-01 2880-0049 2880-0074-01 2880-8917-01 2847-0300 6009-0005 0500-2734-01 2838-9117-04 2848-8101-11 2848-1409-16 1600-0001 1600-0095-01 2848-6301-02 2838-9116-01 2880-0082-01 2113-0004 1417-0042-01 description q t y . ...

  • Page 13

    Sensorvision speeddome q-11 apply pipe sealant to pipe threads [n], then slip elbow [o] over cable and screw elbow onto pipe. Once on, elbow opening should face down. Note: approximately 36cm (14") of cable must exit elbow. The mount is now ready for housing and chassis installation on page q-16. Pl...

  • Page 14: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-12 required parts description q t y . Part no. 0351-0283-01 wall mount install kit 2848-6301-02 2838-9116-01 2880-0011 1600-0095-01 0649-0685-01 1600-0001 2113-0004 1417-0042-01 4 4 4 1 1 1 1 1 washer, flat st, z, .344idx.875od n...

  • Page 15

    Sensorvision speeddome q-13 feed camera dome cables [h] through mounting bracket (i). The mount is now ready for housing and chassis installation. See page q-16. Hook bracket [n] on threaded stud between washer and base [o] while feeding excess cable [p] back through hole in bracket. Level, and tigh...

  • Page 16: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-14 loosely thread washer and nut [i] onto the four threaded studs of base [j]. Next, insert two 1/4-20 leveling screws [k] into bracket [l]. Then, hook bracket on threaded stud between washer and base while feeding excess cable [...

  • Page 17: Required Parts

    Sensorvision speeddome q-15 required parts description q t y . Part no. 1400-0058-01 1417-0036-01 1417-0037-01 2880-0011 1600-0095-01 0649-0685-01 1600-0001 2450-0008-01 2113-0004 1417-0042-01 1 1 2 4 1 1 1 1 1 1 flange fitting, pipe tee nipple, short 1-1/2x 2 anchor bolt, 1/4x2-1/4 w/hardware pipe ...

  • Page 18: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-16 existing composite cable from j-box female compression-type connector pn 2109-0254-06 1 7 description pi 1 2 3 4 5 6 7 data out (lo) data out (hi) ac gnd. Ac data in (lo) data in (hi) brown yellow black red white green orange ...

  • Page 19

    Sensorvision speeddome q-17 at the console, call up the dome address number. Ensure ejector pins are fully inserted in the receptacles. Press and hold the fast key. Then—in order—press and hold the zoom out, focus far, and iris open keys. When the dome begins to pan and tilt, release the keys. Once ...

  • Page 20: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-18 required parts parts/assys description q t y . Part no. 0400-0529-01 0500-4218-01 0351-0386-03 0351-0391-01 0200-0176-01 0200-0177-01 0200-0178-01 1 1 1 1 1 1 1 chassis, fixed/drone shroud, fixed bubble kit, smoked, 9-inch cla...

  • Page 21

    Sensorvision speeddome q-19 existing speeddome cable from j-box replace cinch-jones with female compression-type connector (supplied with dome). Add to a length of bulk composite cable, male and female compression-type connectors and male and female bncs from speeddome cable conversion kit, 0351-040...

  • Page 22

    The world leader in loss prevention q-20

  • Page 23: 4 . 0

    4 . 0 4 . 0 s e r v i c e s e r v i c e fault isolation checklists, replacement parts, adjustments, and component interconnections in this section: • fault isolation checklists ..................................................................... Q-21 video but no dome response / control...............

  • Page 24

    4-2 the world leader in loss prevention.

  • Page 25: Sensormatic

    Sensormatic sensorvision systems what to check. What to do. Video but no dome response / control 1. 2. 3. 4. 5. Dome status. Data at j-box. Inside dome. A. Boards and cables. B. Address. Data into dome. Pan, tilt. Check the dome # in question for the correct dome type and condition. If the dome # is...

  • Page 26: Sensormatic

    The world leader in loss prevention q-22 sensormatic sensorvision systems what to check. What to do. Video / dome control but status incorrect 1. 2. 3. Dome status. Data at j-box. Data from dome to j-box. Check the dome # in question for the correct dome type and condition. If the dome # is incorrec...

  • Page 27: Loss of Lens Function

    Sensorvision speeddome q-23 what to check. What to do. Loss of lens function 1. 2. 3. 4. Connection to camera/lens board. Rs422 interface board. Voltage on camera/lens board. Camera focus. Verify that the failed operation is isolated to the suspect dome. Ensure that the clock spring ribbon cable is ...

  • Page 28: Sensormatic

    The world leader in loss prevention q-24 sensormatic sensorvision systems what to check. What to do. Loss of all lens functions 1. 2. 3. Dome switches. Camera/lens board. Sprockets. Ensure that the position of sw3 on s1 of the rs422 interface board is set to off for enabling lens functions. Ensure t...

  • Page 29: No Tilt Function

    Sensorvision speeddome q-25 what to check. What to do. No tilt function 1. 2. 3. 4. Connection to p1. Sprocket. Tilt motor when the tilt function is commanded. Data when the tilt function is commanded. Reset the dome and observe the orientation (tilt). Verify that the motor is connected to p1 on the...

  • Page 30: Sensormatic

    The world leader in loss prevention q-26 sensormatic sensorvision systems what to check. What to do. No pan function / continuous pan 1. 2. 3. 4. 5. Connection to p3. Sprocket. Pan motor when the pan function is commanded. Data when the pan function is commanded. Slip-ring assembly. Reset the dome a...

  • Page 31

    Sensorvision speeddome q-27 what to check. What to do. No video but all functions work 1. 2. 3. 4. Iris adjustment from controller. Rs422 board. Clock spring ribbon cable. Voltages/zoom, focus, and iris functions. Open the iris and verify that video is present. Check for the presence of video out of...

  • Page 32: Sensormatic

    The world leader in loss prevention q-28 sensormatic sensorvision systems what to check. What to do. Poor video but all functions work 1. 2. Video, gray "humbar." video, no sync. If the monitor is a dedicated (full time) monitor, remove the looping video and set the termination switch to 75 ohms. If...

  • Page 33

    Sensorvision speeddome q-29 what to check. What to do. Picture too light or too dark 1. 2. 3. 4. 5. Open or close the iris at the controller to suit or reset the iris to auto function by holding the iris open and close buttons at the same time. Ensure that the settings of the s1 switch pack on the r...

  • Page 34: Sensormatic

    The world leader in loss prevention q-30 sensormatic sensorvision systems what to check. What to do. Dome targeting incorrect 1. Check the service history of the dome to see if it has been replaced recently. Re-download the software from the console to the dome. The dome may have been put back into ...

  • Page 35: Dead Dome

    Sensorvision speeddome q-31 what to check. What to do. Dead dome 1. 2. 3. 4. Make a visual inspection of the j-box to ensure that the composite cable is connected properly. Unplug the cable and wait 45 sec. Plug the cable back in and test dome operation. Check the voltage (22vac min.) at pins 3 and ...

  • Page 36

    The world leader in loss prevention q-32.

  • Page 37

    Sensorvision speeddome q-33 remove the rs422 interface board (page q-34). Then remove the cpu board by first disconnecting the slip ring [a], pan motor [b], and power supply cables [c], then removing two m3x10 screws [d] and two standoffs [e]. 1. Warning: unexpected pan and tilt can cause injury or ...

  • Page 38: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-34 on the new board, set s1 dip switches to the same settings (if different) as the board to be replaced. 2. Disconnect this board from the dome cpu board by removing its two m3x10 mounting screws [a]. 3. Noting its orientation, ...

  • Page 39

    Sensorvision speeddome q-35 3. 1. 2. To avoid pulling the voltage regulator out of the board, first secure the new board to the eyeball casting using three screws [b]. Then reattach the regulator to the eyeball casting using the m3x10 screw and nut. Finally, reconnect the following six cables (dress...

  • Page 40: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-36 1. Remove the lens and camera shrouds (four screws each). Then remove two m3x8 screws [a] from the back of the camera [b] and unplug its connector from p6 on the camera/lens board [c]. 2. Lift the camera off the back of the le...

  • Page 41

    Sensorvision speeddome q-37 1. Remove the lens and camera shrouds (four screws each). Then remove the old camera [a] by first unplugging its grey ribbon cable [b] from p6 on the camera/ lens board, by removing four m3x10 screws [c], and finally, removing the two m2x6 screws [d] securing the imager h...

  • Page 42: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-38 warning: unexpected pan and tilt can cause injury or damage the dome during servicing. To prevent such movement, always disconnect power/data connector p4 from the rs422 interface board remove the lens and camera shrouds (four...

  • Page 43

    Sensorvision speeddome q-39 remove the lens and camera shrouds (four screws each). Next, detach the old clock- spring cable by unplugging it from the j5 connector on the camera/ lens board [a] and by removing two m3x10 screws [b] securing it to the base of the yoke bracket. Then unplug the cable fro...

  • Page 44: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-40 warning: unexpected pan and tilt can cause injury or damage the dome during servicing. To prevent such movement, always disconnect power/data connector p4 from the rs422 interface board 1. Ready the old slip-ring assembly for ...

  • Page 45

    Sensorvision speeddome q-41 warning: unexpected pan and tilt can cause injury or damage the dome during servicing. To prevent such movement, always disconnect power/data connector p4 from the rs422 interface board 1. Disconnect power supply cables from p5 [a] on the rs422 interface board and from p2...

  • Page 46

    The world leader in loss prevention q-42.

  • Page 47: Before You Begin:

    Sensorvision speeddome q-43 remove the lens and camera shrouds (four screws each). Then, using the appropriate tool*, loosen the back focus setscrew (just beneath the back focus wheel). This screw keeps the wheel stationary. Warning: if servicing a color camera, be careful not to disturb the copper-...

  • Page 48: Sensormatic

    Sensormatic sensorvision systems the world leader in loss prevention q-44 using a pair of needle nose pliers, grab the ends of the camera cable clamp [a] and gently pull it up until it swings to one side [b]. Next, noting how the ribbon cable is looped [c], reseat the cable into the connector. Final...

  • Page 49

    Sensorvision speeddome q-45 j5 jp4 p2 jp2 jp3 p5 jp1 jp2 p3 p4 ac/data from indoor j-box or oib*, page 48. Receives female 7-pin compression-type connector 2109-0254-06 j1 clock-spring ribbon cable assy. 0650-0623-01 p6 p1 j2 j3 j4 ac input dc output note: monochrome camera uses cable pn 0650-0666-0...

  • Page 50: Sensormatic

    The world leader in loss prevention q-46 sensormatic sensorvision systems 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 video (hi) signal video (lo) gnd. Cam. +12vdc cam. Gnd. Vert. Sync. Hor. Sync. B0 b1 b2 b3 b4 b5 (blc) d/a 1 (agc) d/a 2 (alc) n.C. Nagcv p6 1 2 3 4 5 6 7 out b channel b (vcc) +5vdc chan...

  • Page 51

    Sensorvision speeddome q-47 gnd. Out 0 (p0) out 1 (p1) out 2 (p2) out 3 (p3) +12vdc alarm 0 gnd. Alarm 1 gnd. Alarm 2 gnd. Alarm 3 gnd. Power supply 1 2 3 4 5 6 7 8 9 10 11 12 j5 +12vdc gnd. Txd spare rxd reset vert. Sync. Horz. Sync. Camera gnd. Camera +12vdc video (hi) signal video (lo) gnd. +12vd...

  • Page 52: Sensormatic

    The world leader in loss prevention q-48 sensormatic sensorvision systems j2 ac/data from outdoor j-box j1 video output bnc e1 e1 e6 e5 e1 e1 e1 e1 e9 e8 e7 e4 e3 e2 e1 e1 from j1 rs422 interface board video video gnd. Heater strip 5305-0003-01 main cooling fan 0650-0678-01 j3 low temp. Cut-out ther...

  • Page 53

    Sensormatic electronics corporation 500 northwest 12th avenue deerfield beach, florida 33442 u.S.A. Telephone 305/420-2000 telefax 305/420-2017 toll-free 800/241-6678 © 1994 sensormatic electronics corporation the world leader in loss prevention ®.