Tadiran Telecom Coral IPx 500 Installation Manual - page 137

Manual is about: Tadiran Telecom Coral IPx 500 Installation Manual

Summary of Coral IPx 500

  • Page 1

    Coral ipx 5 00 installation procedure and hardware reference manual the flexible way to communicate.

  • Page 2

    © copyright by tadiran telecom ltd., 2004. All rights reserved worldwide. The coral is protected by u.S. Patents 6,594,255; 6,598,098; 6,608,895; 6,615,404 all trademarks contained herein are the property of their respective holders. The information contained in this document is proprietary and is s...

  • Page 3

    Federal communications commission rules part 68 compliance statement this equipment complies with part 68 of the fcc rules. On this equipment is a label that contains, among other information, the fcc registration number and ringer equivalence number (ren) for this equipment. If requested, this info...

  • Page 4

    Canadian dot compliance statement notice: the industry canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate terminal equipment technical requirements ...

  • Page 5: Equipment Compliance

    Ul safety of information technology equipment compliance this equipment has been tested and complied with the following: usl compliance usl indicates listing to u.S. Standard for information technology equipment including electrical business equipment, ul60950, third edition. Cnl compliance cnl indi...

  • Page 6: Part 15

    Federal communications commission part 15 the fcc wants you to know this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a resi...

  • Page 7: Table of Contents

    Table of contents chapter 1 - introduction 1.1 about this manual..................................................................................................................... 1-1 document description ................................................................................................

  • Page 8

    3.3 peripheral interface card initialization...................................................................................... 3-15 introduction ............................................................................................................................. 3-15 system initializatio...

  • Page 9

    5.6 mdfipx units ............................................................................................................................ 5-21 mdfipx configurations ........................................................................................................... 5-21 mdfipx with i/o ca...

  • Page 10

    Chapter 7 - power supply 7.1 ps500 dc................................................................................................................................. 7-1 general description ................................................................................................................

  • Page 11

    8.3 imc8 card ................................................................................................................................ 8-23 general information ................................................................................................................ 8-23 imc8 installat...

  • Page 12

    9.4 three-way conference ............................................................................................................ 9-29 general description ................................................................................................................ 9-29 database programming .....

  • Page 13

    9.11 music ...................................................................................................................................... 9-63 introduction ............................................................................................................................. 9-63 circu...

  • Page 14

    10.2 peripheral card description ................................................................................................... 10-7 general description ................................................................................................................ 10-7 xxxipx, xxxsl, and xxx20...

  • Page 15: List of Figures

    List of figures figure 2-1: coral ipx 500 sizes and weights.......................................................................................................... 2-7 figure 2-2: coral ipx 500 distance between the expansion cage and the main cage .......................................... 2-8 fig...

  • Page 16

    Figure 2-29: coral ipx 500 mdfipx ground assembly............................................................................................ 2-49 figure 2-30: coral ipx 500 ground connection for 1mdfipx units......................................................................... 2-50 figure 2-31:...

  • Page 17

    Figure 5-5: connecting surge arrestor magazine to the mdfipx............................................................................ 5-13 figure 5-6: power fail wiring to single-line (500/2500) telephone set ................................................................ 5-17 figure 5-7: flexse...

  • Page 18

    Figure 6-9: closing the door.................................................................................................................................... 6-8 figure 6-10: removing the door ...........................................................................................................

  • Page 19

    Figure 6-39: system with three cages (ipx 500m and two ipx 800x cages)....................................................... 6-48 figure 6-40: connection between two ipx 500 cages (ipx 500m and 500x) ........................................................ 6-50 figure 6-41: connection between three...

  • Page 20

    Figure 8-6: imc8 flash memory card - left side .................................................................................................... 8-23 figure 8-7: imc8 flash memory card - right side ................................................................................................. 8...

  • Page 21

    Figure 9-20: una bell - wiring to tone generator .................................................................................................. 9-79 figure 9-21: una bell - wiring to mechanical bell ....................................................................................................

  • Page 23: List of Tables

    List of tables table 1-1: related documentation .......................................................................................................................... 1-3 table 1-2: coral ipx 500 system specifications..................................................................................

  • Page 24

    Table 5-12: champ 50 connector - trunk interface card pinout (main cage slot# 1,2,3) ..................................... 5-39 table 5-13: block 66 mdf - wired station interface pinout .................................................................................... 5-41 table 5-14: block 66 mdf...

  • Page 25

    Table 6-5: jumper configuration for coral ipx 500x............................................................................................... 6-36 table 6-6: number of universal i/o slots per system configuration ...................................................................... 6-42 table 6...

  • Page 27: Chapter

    Coral cor coral ipx 500 installation manual chapter 1 introduction 1.1 about this manual................................................1-1 1.2 about the coral ipx 500 .....................................1-7.

  • Page 29: 1.1

    Introduction 1-1 ab out thi s ma nual 1 1.1 about this manual the coral ipx 500 installation guide and hardware reference manual, is designed for field use by coral system installation and service personnel. It describes the installation of the coral ipx 500 system. This manual is divided into two p...

  • Page 30

    1-2 coral ipx 500 installation manual ab out thi s ma nual 1 chapters 6, 7, 8, 9 and 10 describe the hardware reference. These chapters offer detailed technical information about coral ipx 500 system hardware, including cage specifications, internal power supplies, and interface circuit operation: w...

  • Page 31: Related Documentation

    Introduction 1-3 ab out thi s ma nual 1 for further information not in the scope of this manual about coral service cards coral peripheral cards, voice terminals, voip devices, etc., consult the following documentation: table 1-1 related documentation 2 related documentation item subject manual cora...

  • Page 32: Tip:

    1-4 coral ipx 500 installation manual ab out thi s ma nual 1 this manual includes information that requires special attention, or is distinguished from the main texts in some significant way. These are indicated by the use of symbols and text formatting. This is illustrated in the following examples...

  • Page 33: List of Abbreviations

    Introduction 1-5 ab out thi s ma nual 1 16sftipx ........16 digital station flexset terminal/telephones interface card 16slsipx ........16 single line telephones interface card 2skwsl...........Coralair wireless extension interface card with support for 2 rbs (radio base stations) 30tsl ...............

  • Page 34

    1-6 coral ipx 500 installation manual ab out thi s ma nual 1 8tpfsl ........... 8 analog trunk line card with power fail circuits card 8t-gipx .......... 8 analog trunk line card ps500 ac ...... Ac power supply (main and expansion units) ps500 dc ...... Dc power supply (main and expansion units) ipx...

  • Page 35: 1.2

    Introduction 1-7 ab out the co ral ipx 5 00 1 1.2 about the coral ipx 500 0 capacity the coral ipx 500 is a small wall or rack-mounted pabx, designed to fit in the low to medium range of the private pbx telephone market. Coral ipx 500 supports all the coral flexicom and coral ipx family features. Th...

  • Page 36

    1-8 coral ipx 500 installation manual ab out the co ral ipx 5 00 1 circuitry the coral ipx 500 is a digital communications switching system is based on pulse code modulation (pcm) switching technology. The active circuitry of the system is contained on a backplane and removable cards. The active cir...

  • Page 37

    Introduction 1-9 ab out the co ral ipx 5 00 1 major features the cage houses all hardware components of the coral ipx 500 system including the power supply unit, control cards, peripheral cards, and i/o connections. In addition, the cage: provides all the features, capabilities, interfaces, and term...

  • Page 38

    1-10 coral ipx 500 installation manual a b out the c o ral ipx 5 00 1 table 1-2 coral ipx 500 system specifications specification * coral ipx 500m main cage coral ipx 500x expansion cage coral ipx 800x expansion cage mcp-ipx card slots 1 — — px card slots † — — 1 or 0 shared service card slots msbip...

  • Page 39: Recommended Tools

    Introduction 1-11 ab out the co ral ipx 5 00 1 0 the following tools are needed in order to install and maintain the coral ipx 500 system: required tools: 4 mm (max.) flat blade screwdriver for installation and removal of the door 3/16", 1/4", and 5/16" straight-blade screwdrivers #1 and #2 phillips...

  • Page 40

    1-12 coral ipx 500 installation manual ab out the co ral ipx 5 00 1 optional tools: modular line polarity tester flashlight tone/continuity/talk battery generator tone detector/amplifier probe telephone line test set with mf tone signalling capability alligator clip leads amp™ champ™ installation to...

  • Page 41: Chapter

    Coral cor coral ipx 500 installation manual chapter 2 hardware installation procedure 2.1 site inspection.....................................................2-1 2.2 equipment installation .......................................2-17 2.3 program interface device connection ..............2-75.

  • Page 43: 2.1

    Hardware installation procedure 2-1 site inspection 2 2.1 site inspection 0 the coral ipx 500 system should be installed in restricted access areas (dedicated equipment rooms, equipment closets, or the like) in accordance with articles 110-16, 110-17, and 110-18 of the national electric code, ansi/n...

  • Page 44

    2-2 coral ipx 500 installation manual site inspection 2 7. Verify that the installation area is free of caustic or corrosive liquids, substances, or materials. Check local building codes for additional requirements. 8. Verify that the installation area is located no closer than 20 ft (6.1m) from ele...

  • Page 45: Space Requirements

    Hardware installation procedure 2-3 site inspection 2 0 general this section describes the coral ipx 500 space requirements. 1. Verify that there is sufficient space for the coral ipx 500 system components. 2. The dimensions and weights of the various components are provided in figure 2-1 , table 2-...

  • Page 46

    2-4 coral ipx 500 installation manual site inspection 2 mdf 1. Sufficient space must be reserved for the main distribution frame (mdf), in addition to the space required by the cage. The mdf should be located immediately adjacent to the coral cage. The floor space in front of the mdf must be clear f...

  • Page 47

    Hardware installation procedure 2-5 site inspection 2 table 2-1 coral ipx 500 dimensions item dimension inches centimeters (cm) ipx 500m, 500x cage rack-mounted width 19 48 depth 8 20.4 height - 8.7u 15.2 39 ipx 500m, 500x cage wall-mounted width 18.5 47 depth 9.2 23.3 height - 8.7u 15.2 39 ipx 800x...

  • Page 48

    2-6 coral ipx 500 installation manual site inspection 2 table 2-2 coral ipx 500 weights m table 2-3 coral ipx 500 clear space requirements item pounds kilograms ipx 500m, 500x cage (fully loaded) * *the weight provided is typical and can significantly differ depending on the type of cards installed....

  • Page 49

    Hardware installation procedure 2-7 site inspection 2 figure 2-1 coral ipx 500 sizes and weights 19in. 48cm. 18.5in. 47cm. 15.2in. 39cm. 15.2in. 39cm. 15.3in. 39cm. 7.3in. 18.5cm. 14.5in. 37cm. 15.3in. 39cm. Weight 20.3lb. 9.2kg. Weight 31lb. 14kg. Weight 15lb. 6.8kg. Weight (fully loaded) 30lb. 13....

  • Page 50

    2-8 coral ipx 500 installation manual site inspection 2 figure 2-2 coral ipx 500 distance between the expansion cage and the main cage ipx 500m cage min. 2u (3.5") 9 cm. Max. (31.4") 80 cm. Notes: 1. Measurements are given with cage covers in place. 2. Mdf location must be taken into account. Min. 2...

  • Page 51

    Hardware installation procedure 2-9 site inspection 2 space above and below the ipx 500 cage the coral ipx 500 cage requires a minimum space of 2u (3.5" or 9cm) above the top cover in order to allow space for maintenance purposes (that is, adequate space for opening the top cover and routing the cab...

  • Page 52

    2-10 coral ipx 500 installation manual site inspection 2 space in front of wall mounted systems a minimum of 36” (1 meter) must be left free in front of the system. Figure 2-5 displays a typical wall mounted system configuration. Figure 2-5 coral ipx 500 space required in front of wall-mounted syste...

  • Page 53

    Hardware installation procedure 2-11 site inspection 2 space in front and behind rack mounted ipx 500 cages when cages are mounted onto a rack with the rear panel exposed (that is, not facing the wall or the rear panel of other cages), 36” (1 meter) must be left free in front of the system and 3.5” ...

  • Page 54

    2-12 coral ipx 500 installation manual site inspection 2 space between cages rack mounted back to back if racks are mounted with cages mounted back to back, a minimum space of 2u (3.5" or 9cm) must be maintained between the rear panels of the cages. Or a minimum of 14.5” or 36.8cm must be maintained...

  • Page 55: Electrical Requirements

    Hardware installation procedure 2-13 site inspection 2 0 general requirements the coral ipx 500 operates from a standard wide input 100-240vac, 47-63hz source or from a -48vdc source. Ac powered units can be supplied with a built-in backup battery for 1 hour of operation. 1. Verify that electrical s...

  • Page 56

    2-14 coral ipx 500 installation manual site inspection 2 table 2-4 coral ipx 500 maximum power requirements configuration * *maximum power requirement is a maximum case projection based on fully populated systems. The total number may be defined per actual system. 115vac 230vac -48vdc ipx 500m 6a 3a...

  • Page 57

    Hardware installation procedure 2-15 site inspection 2 dc electrical requirements dc units must comply with the following instructions: 1. Restricted access area : the dc powered equipment should only be installed in a restricted access area. 2. Installation codes : the equipment must be installed a...

  • Page 58: Notes:

    2-16 coral ipx 500 installation manual site inspection 2 notes:.

  • Page 59: 2.2

    Hardware installation procedure 2-17 eq uip m ent insta lla tio n 2 2.2 equipment installation all coral ipx 500 cage descriptions are covered in chapter 6 - cage description . The cage mounting and installation procedure includes the following stages: mounting the cage onto the wall or the rack, in...

  • Page 60: Wall Mounted Installations

    2-18 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 the process of mounting and installing the wall-mounted cage includes the following stages: unpacking the shipping container, on page 2-18 checking the space and positioning requirements, on page 2-20 removing the cage door and ...

  • Page 61

    Hardware installation procedure 2-19 eq uip m ent insta lla tio n 2 table 2-5 part list (items per wall-mounted ipx 500 cage) item description quantity main cage (ipx 500m), including one mcp-ipx card or expansion cage (ipx 500x), including one h-500/1 expansion cable with male-female d-type 50-pin ...

  • Page 62

    2-20 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 checking the space and positioning requirements verify that the coral ipx 500 cage will be positioned in accordance with local and system requirements. The spacing requirements as described in “space requirements” starting on page...

  • Page 63

    Hardware installation procedure 2-21 eq uip m ent insta lla tio n 2 assembling the left decorative cover 1. Assemble the left decorative cover to the cage as shown in figure 2-9 . 2. Fasten the left decorative cover to the cage with four of the 3mm nylon snap rivets provided. Figure 2-9 left side de...

  • Page 64

    2-22 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 assembling the right decorative cover 1. Assemble the right decorative cover to the cage as shown in figure 2-10 . 2. Fasten the right decorative cover to the cage with four of the 3mm nylon snap rivets provided. Figure 2-10 right...

  • Page 65

    Hardware installation procedure 2-23 eq uip m ent insta lla tio n 2 fastening the bottom panel support bracket 1. Insert the m3 curved washers onto the m3 phillips screws. 2. Insert the m3 flat washers onto the m3 phillips screws. 3. Insert the two screws into the bottom panel support bracket and fa...

  • Page 66

    2-24 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 attaching the wall mounting bracket onto the wall 1. Verify that the wall mounted surfaces of the installation area are painted or sealed plywood with a minimum thickness of 3/4 inch (2 cm) or a similar material capable of support...

  • Page 67

    Hardware installation procedure 2-25 eq uip m ent insta lla tio n 2 figure 2-13 coral ipx 500 system blueprint (not in scale) 330mm 165mm 30 9mm 165 mm 165 mm main cage coral ipx 500m 309mm second expansion cage coral ipx 500x 73.7 " (187c m) max. First expansion cage coral ipx 500x 110mm 72.6mm 35 ...

  • Page 68

    2-26 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 4. Drill the holes for the cage and the mdfipx as follows: for wooden walls, use a 5/64” (2mm) drill bit to drill appropriate holes into the wall for the provided mounting screws. Skip to step 6 . For walls constructed from concre...

  • Page 69

    Hardware installation procedure 2-27 eq uip m ent insta lla tio n 2 mounting the cage onto the wall mounting bracket 1. With the help of an assistant, grasp each end of the cage and lift it over the wall mounting bracket as shown in figure 2-15 . Tilt the card cage back slightly, so that the rear pa...

  • Page 70

    2-28 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 dismounting the cage from the wall 1. Do one of the following: for dc powered systems, turn off the power switch and shut down the facilities power supply unit that supplies power to the cage. For ac powered systems, disconnect th...

  • Page 71: Rack Mounted Installations

    Hardware installation procedure 2-29 eq uip m ent insta lla tio n 2 0 the process of mounting and installing the rack mounted cage includes the following: unpacking the shipping container, on page 2-29 checking the space and positioning requirements, on page 2-31 removing the cage door and top cover...

  • Page 72

    2-30 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 table 2-6 part list (items per rack-mounted ipx 500 cage) item description quantity main cage (ipx 500m), including one mcp-ipx card or expansion cage (ipx 500x), including one h-500/1 expansion cable with male-female d-type 50-pi...

  • Page 73

    Hardware installation procedure 2-31 eq uip m ent insta lla tio n 2 checking the space and positioning requirements verify that the coral ipx 500 cage will be positioned in accordance with local and system requirements. The spacing requirements as described in “space requirements” starting on page 2...

  • Page 74

    2-32 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 preparing the cage for 23" rack-mounted configuration 1. Reposition the hanging pin assembly on the left bracket as depicted in step 1 of figure 2-18 and align the bracket with the cage such that the narrow edge of the bracket is ...

  • Page 75: Note

    Hardware installation procedure 2-33 eq uip m ent insta lla tio n 2 mounting the cage onto the rack 1. Verify the cage mounting position on the rack. In addition to customer requirements, requirements for heat dissipation need to be taken into account. See page 2-11, space in front and behind rack m...

  • Page 76

    2-34 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-19 left side view of coral ipx cage mounted onto 19" rack figure 2-20 left side view of coral ipx cage mounted onto 23" rack left side mounting bracket 19" configuration hanging pin customer supplied fasteners left side m...

  • Page 77

    Hardware installation procedure 2-35 eq uip m ent insta lla tio n 2 dismounting the cage from the rack 1. Do one of the following: for dc powered systems, turn off the power switch and shut down the facilities power supply unit that supplies power to the cage. For ac powered systems, disconnect the ...

  • Page 78

    2-36 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 the coral ipx 500 can operate with an mdfipx unit that has been supplied with the system or with an mdf unit that has been supplied separately by the customer. If the system includes a customer-supplied mdf, skip to page 2-40, b...

  • Page 79

    Hardware installation procedure 2-37 eq uip m ent insta lla tio n 2 unpacking the shipping container 1. Inspect the shipping container for evidence of physical damage or mishandling. Report any damage to the carrier immediately. 2. If it is necessary to make a damage claim to the carrier, do not mov...

  • Page 80

    2-38 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 table 2-8 part list for mdfipx fully assembled table 2-9 part list for mdfipx without accessories attached item description quantity wall mounting kit, including four 4.2x32 screws and four wall plugs 1 mdf frame 1 mdf cover 1 mdf...

  • Page 81

    Hardware installation procedure 2-39 eq uip m ent insta lla tio n 2 mounting the mdfipx onto the wall 1. Verify that four holes have been drilled (for each mdfipx unit) into the wall, as described on page 2-24, attaching the wall mounting bracket onto the wall , using the installation template provi...

  • Page 82

    2-40 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 the battipx unit provides backup power to ac powered systems and is ordered separately by the customer if desired. If the installation is dc powered system or does not include the battipx units, skip to page 2-46, ground wiring ...

  • Page 83

    Hardware installation procedure 2-41 eq uip m ent insta lla tio n 2 unpacking the shipping container 1. Inspect the shipping container for evidence of physical damage or mishandling. Report any damage to the carrier immediately. 2. If it is necessary to make a damage claim to the carrier, do not mov...

  • Page 84

    2-42 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 mounting the battery pack onto the wall 1. Fasten brackets a and b to the battery pack with the four m4 screws provided as shown in figure 2-23 . Figure 2-23 bracket mounting for wall configuration 2. Using the dimensions in figur...

  • Page 85

    Hardware installation procedure 2-43 eq uip m ent insta lla tio n 2 6. Insert the top two holes of the brackets on the battery pack over the screws and allow the unit to hang on the screws, while supporting the weight of the battery pack. 7. Tighten the top two screws completely. 8. Insert the botto...

  • Page 86

    2-44 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 mounting the battery pack onto the rack 1. Fasten brackets a and b to the battery pack with the four m4 screws provided as shown in figure 2-26 . Figure 2-26 bracket mounting for rack configuration 2. Insert screws (supplied by th...

  • Page 87

    Hardware installation procedure 2-45 eq uip m ent insta lla tio n 2 figure 2-27 mounting the battipx unit onto a rack connecting the battery pack to the ltu/csu unit 1. Connect the ltu/csu power cable to the ltu/csu unit. See page 7-46, connecting the battery pack to the ltu/csu unit . Closing the b...

  • Page 88: Ground Wiring

    2-46 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 proper system grounding is critical to reliable system operation. System grounding is only as effective as the ground point itself. To ensure adequate protection from interference by radio frequency energy, electrical impulse no...

  • Page 89

    Hardware installation procedure 2-47 eq uip m ent insta lla tio n 2 the system ground connection procedure varies depending on whether an mdfipx unit has been supplied with the system or whether an mdf is supplied separately by the customer: if the system includes an mdfipx, see page 2-48, ground co...

  • Page 90

    2-48 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 ground connection for systems that include an mdfipx if the coral ipx 500 system includes an mdfipx unit, it can function as a master ground, and no additional master ground needs to be used. See figure 2-29 , figure 2-30 , and fi...

  • Page 91

    Hardware installation procedure 2-49 eq uip m ent insta lla tio n 2 8. Skip to page 2-55, circuit card partial installation . Figure 2-29 coral ipx 500 mdfipx ground assembly r=1.0 ohm max. Building entrance ground main cage ground wire with ring terminal to building entrance se rr a ted w a s h er ...

  • Page 92

    2-50 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-30 coral ipx 500 ground connection for 1mdfipx units building entrance ground 1mdfipx ipx 500x cage 2 ipx 500x cage 1 ipx 500m cage 0 ground terminal r=1.0 ohm max. 1mdfipx 1mdfipx all ground wires are to be 10 awg strand...

  • Page 93

    Hardware installation procedure 2-51 eq uip m ent insta lla tio n 2 figure 2-31 coral ipx 500 ground connection for 2mdfipx units building entrance ground ipx 500x cage 2 ipx 500x cage 1 ipx 500m cage 0 all ground wires are to be 10 awg stranded wire with ring terminals. 1.0 ohm max. 2mdfipx 2mdfipx...

  • Page 94

    2-52 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 ground connection for systems that include a customer-supplied mdf if the coral ipx 500 system does not include an mdfipx unit, or if the system includes ipx 800x cages, a master ground must be included within the system. See figu...

  • Page 95

    Hardware installation procedure 2-53 eq uip m ent insta lla tio n 2 a. Unfasten one of the 10-32 unf screws connected to the master ground unit and retain the screw and serrated washer. See figure 2-32 . B. Insert the 10-32 unf screw such that the ground wire ring terminal is positioned between the ...

  • Page 96

    2-54 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-34 ground connection for system with three cages including customer supplied mdf units master ground r=1.0 ohm max. Building entrance ground main cage 0 customer supplied mdf expansion cage 1 10 awg stranded wires with ri...

  • Page 97

    Hardware installation procedure 2-55 eq uip m ent insta lla tio n 2 0 . Inserting a coral circuit card 1. Connect the static dissipating wrist strap connector to the cage and put on the strap. Figure 2-35 esd strap connection to cage 2. To insert a circuit card into a card slot, grasp the card with ...

  • Page 98

    2-56 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 3. Verify that the card is oriented correctly (red diagnostic indicator on front side toward top of card). 4. Align the edges of the circuit card with the card edge guides in the card cage, and gently slide the card straight into ...

  • Page 99

    Hardware installation procedure 2-57 eq uip m ent insta lla tio n 2 peripheral interface card installation table 2-11 lists the peripheral interface card types that may be inserted into each card slot in the coral ipx 500 system. The discontinued xxxsl and xxx-200 cards are for use in slots 1 throug...

  • Page 100

    2-58 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-40 , may be used as a worksheet by the system designer to establish card placement prior to installation. Refer to coral ipx 800 installation manual - section-2 and coral service and peripheral cards installation manual ....

  • Page 101

    Hardware installation procedure 2-59 e q ui p m ent inst a ll a ti o n 2 table 2-11 coral ipx 500 card types * these cards may require changes to option straps which affect interface characteristics or operation. For reference material see the coral service and peripheral cards installation manual ....

  • Page 102: Note

    2-60 coral ipx 500 installation manual e q ui p m ent inst a ll a ti o n 2 figure 2-36 coral ipx 500 main cage 500m - card placement diagram 1 62 7 3 8 4 5 card type: card type: card type: card type: card type: card type: card type: .............. .............. .............. .............. ..........

  • Page 103

    Hardware installation procedure 2-61 e q ui p m ent inst a ll a ti o n 2 figure 2-37 coral ipx 500 1st expansion cage 500x - card placement diagram 1 62 7 3 8 4 9 5 10 card type: card type: card type: card type: card type: card type: card type: .............. .............. .............. .............

  • Page 104

    2-62 coral ipx 500 installation manual e q ui p m ent inst a ll a ti o n 2 figure 2-38 coral ipx 500 2nd expansion cage 500x - card placement diagram 1 62 7 3 84 9 5 10 card type: card type: card type: card type: card type: card type: card type: .............. .............. .............. ............

  • Page 105: Note

    Hardware installation procedure 2-63 eq uip m ent insta lla tio n 2 figure 2-39 coral ipx 500 1st expansion cage 800x - card placement diagram 1 2 3 4 5 6 7 8 9 10 11 12 coral ipx 800x 1st expansion cage card type: card type: card type: card type: card type: card type: card type: card type: ...........

  • Page 106

    2-64 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-40 coral ipx 500 2nd expansion cage 800x - card placement diagram 1 2 3 4 5 6 7 8 9 10 11 12 card type: card type: card type: card type: card type: card type: card type: card type: .............. .............. .............

  • Page 107

    Hardware installation procedure 2-65 eq uip m ent insta lla tio n 2 0 this section describes how to interconnect the cages within the coral ipx 500 system. For a full description of the different system configurations, see page 6-49, interconnecting the main and expansion cages . An h500-1 cable is ...

  • Page 108

    2-66 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 in the coral ipx 500 system, part of the motherboard (main service board), performs the shared service function. The motherboard msbipx of the main cage ipx 500m mspipx of the expansion cage ipx 500x may require changes to jumpe...

  • Page 109

    Hardware installation procedure 2-67 eq uip m ent insta lla tio n 2 4. In the ipx 500x expansion cages, configure the following jumpers: table 2-13 jumpers in the expansion cage 5. In the ipx 800x expansion cages, configure the jumpers as described in the coral ipx 800 installation manual . 6. Skip ...

  • Page 110

    2-68 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 this section describes how to insert the power supply card into its slot. The power supply card is inserted only after the system has been completely grounded and the jumpers configured. The power supplies used in the coral ipx ...

  • Page 111: Ps500  Ac

    Hardware installation procedure 2-69 eq uip m ent insta lla tio n 2 figure 2-41 ps500 front panel 6. Skip to page 2-70, connecting the power wires alarm power ps500 ac cat. No. 72440953300 on off caution! Hazard of electric shock. Disconnect power before servicing. Top captive screw alarm (red) indi...

  • Page 112

    2-70 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 0 the coral ipx 500 can operate as an ac powered system or as a dc powered system. For ac powered systems, skip to page 2-73, ac powered systems . Dc powered systems this section describes how to connect the power wires to the cor...

  • Page 113

    Hardware installation procedure 2-71 eq uip m ent insta lla tio n 2 figure 2-42 dc power wiring for one coral ipx 500 cage to ac power master ground (or mdfipx ground) dc power input connection building entrance ground customer supplied mdf ground network termination ground r=1.0 ohm max. Ground nut...

  • Page 114

    2-72 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 figure 2-43 dc power wiring for three coral ipx 500 cages circuit breaker 30a 250v s.B. To second expansion cage to second expansion cage -48v busbar panel +48v busbar panel r=1.0 ohm max. Building entrance ground to first expansi...

  • Page 115

    Hardware installation procedure 2-73 eq uip m ent insta lla tio n 2 ac powered systems this section describes how to connect the power wires to the coral ipx 500 cage for ac powered systems (that is, when the ps500 ac power supply card is installed in the cage). Figure 2-44 shows the ac power wiring...

  • Page 116

    2-74 coral ipx 500 installation manual eq uip m ent insta lla tio n 2 2. Verify that the battipx power switch is in the off position (turned downwards on right side). 3. Insert the pabx/ps connector of the dc power wire pair into the upper panel socket of the ps500 ac power supply. See figure 2-44 ....

  • Page 117: 2.3

    Hardware installation procedure 2-75 pr ogr a m interface device connection 2 2.3 program interface device connection the data terminal or personal computer that will be used as the program interface (pi) device must be equipped with an rs-232e asynchronous serial data interface that can be configur...

  • Page 118

    2-76 coral ipx 500 installation manual pr ogr a m interface device connection 2 figure 2-45 25 pin program interface device connections to kb0 figure 2-46 9 pin program interface device connections to kb0 kb0 programming port (use female cable 9 pin connector) 13 4 - data terminal ready 25 14 1 1 - ...

  • Page 119: Chapter

    Coral cor coral ipx 500 installation manual chapter 3 initial power-up tests 3.1 power supply test............................................... 3-1 3.2 common control test.........................................3-7 3.3 peripheral interface card initialization .............3-15 3.4 battery backup ...

  • Page 121: 3.1

    Initial power-up tests 3-1 po wer sup ply t est 3 3.1 power supply test this chapter provides information about the connection of the backup battery and the power supply. In addition, information is provided about the initial tests that must be performed when first installing a coral ipx 500 system....

  • Page 122: Dc Powered Systems

    3-2 coral ipx 500 installation manual po wer sup ply t est 3 0 1. Verify that the cage ground wire is connected and the ground nut is tightened. See page 2-46, ground wiring . 2. Verify that the ps500 dc unit has been properly installed and the two captive screws on the upper and lower parts of the ...

  • Page 123

    Initial power-up tests 3-3 po wer sup ply t est 3 figure 3-1 coral ipx 500 cage with ps500 dc unit and power connections installed to facilities dc power source opening for dc power connector ps500 dc power supply.

  • Page 124: Ac Powered Systems

    3-4 coral ipx 500 installation manual po wer sup ply t est 3 0 1. Verify that the cage ground wire is connected and the ground nut is tightened. See page 2-46, ground wiring . 2. Verify that the ps500 ac unit has been properly installed and the two captive screws on the upper and lower parts of the ...

  • Page 125

    Initial power-up tests 3-5 po wer sup ply t est 3 figure 3-2 coral ipx 500 cage with ps500 ac unit and power connections installed to battery pack to ac power outlet backup battery connector ac power connector ps500 ac power supply.

  • Page 126: Notes:

    3-6 coral ipx 500 installation manual po wer sup ply t est 3 notes:.

  • Page 127: 3.2

    Initial power-up tests 3-7 comm on co ntr o l t est 3 3.2 common control test this section deals with the common control test. 0 the mcp-ipx control card layout is shown in figure 3-3 . 1. In the main cage and in the expansion cages, verify that the ps500 power switch is in the off position (turned ...

  • Page 128

    3-8 coral ipx 500 installation manual comm on co ntr o l t est 3 5. Verify that the dbx and cla baby cards are not attached to the mcp-ipx interface connector j1. See figure 3-3 for the location of the memory interface connectors. See figure 3-4 for the cla and dbx cards. See chapter 8 - control car...

  • Page 129

    Initial power-up tests 3-9 comm on co ntr o l t est 3 the line that reads no ccs version indicates that no generic feature software was detected in the imc8 card. To load generic feature software into the imc8 card, follow the procedure in chapter 4 - upgrade . 16. If the following message appears o...

  • Page 130

    3-10 coral ipx 500 installation manual comm on co ntr o l t est 3 copyright (c) 2001-yyyy............... Name - (site name) sau # - do the following: a. If the second message appears, the system initialized properly and is capable of processing calls. The version number of the generic feature softwa...

  • Page 131

    Initial power-up tests 3-11 comm on co ntr o l t est 3 ************************* chk ram end chk ram custom init code... . . . The second message may appear after two or three minutes, following several short messages that appear during system start-up: ccs is on the air...... (root) ccs xx.Xx.Xx co...

  • Page 132

    3-12 coral ipx 500 installation manual comm on co ntr o l t est 3 figure 3-3 mcp-ipx card layout dbx/cla connector j1 bus controller kb0 address decoder remove before use database memory backup battery sau connector cpu 386ex dbx/cla mounting hole cla mounting holes option dip switches (always set t...

  • Page 133

    Initial power-up tests 3-13 comm on co ntr o l t est 3 figure 3-4 cla and dbx baby cards layout rst led co m 1 line 10base-t coralink cla reset button dip switches are all set to the right for normal operation rj-45 network interface maintenance port cla card status indicator led remove before use c...

  • Page 134

    3-14 coral ipx 500 installation manual comm on co ntr o l t est 3 0 if the start-up tests detect that the voltage level of a lithium backup battery on the mcp-ipx or dbx card is insufficient to reliably maintain the memory contents in the event of power failure, one of the following messages will ap...

  • Page 135: 3.3

    Initial power-up tests 3-15 peri pheral int erf ace car d init ial izati on 3 3.3 peripheral interface card initialization this section describes how to initialize the peripheral cards. Perform this section only after the mcp-ipx control card in the main cage has been initialized properly. If the pe...

  • Page 136

    3-16 coral ipx 500 installation manual peri pheral int erf ace car d init ial izati on 3 rules for inserting a coral circuit card 1. Connect the static dissipating wrist strap connector to the cage and put on the strap. See figure 2-35 on page 2-55 . 2. To insert a circuit card completely into its s...

  • Page 137

    Initial power-up tests 3-17 per ipheral in te rf ace ca rd ini tia li zat ion 3 interface & database reference manual for more information. Using the pi, verify that each of the parameters detailed below contain the appropriate information. 7. Access the card list branch of the pi (route: clis) to v...

  • Page 138

    3-18 coral ipx 500 installation manual peri pheral int erf ace car d init ial izati on 3 table 3-1 card slot status messages . Displayed message description technical recommendations active initialization was successfully completed. None active/p card is partially active because there are not enough...

  • Page 139: System Initialization

    Initial power-up tests 3-19 peri pheral int erf ace car d init ial izati on 3 0 preparing for initialization after the software has been installed and initialized: 1. In the expansion cages, verify that the ps500 or ps19 power switch is in the off position (turned downwards). Before proceeding, veri...

  • Page 140

    Peri pheral int erf ace car d init ial izati on 3 first expansion cage initialization 1. Turn on the power supply unit in the first expansion cage. Turn on the power supply unit within the expansion cage only after powering the main cage and verifying that the control card has initialized properly, ...

  • Page 141: 3.4

    Initial power-up tests 3-21 battery backup (ba t t ipx) t est 3 3.4 battery backup (battipx) test the battipx unit provides backup power to ac powered systems and is ordered separately by the customer if desired. If the installation does not include battipx units, skip to page 3-23, i/o cable instal...

  • Page 142: Operating The Battery Pack

    3-22 coral ipx 500 installation manual battery backup (ba t t ipx) t est 3 0 1. Verify that the ps500 ac unit has been properly installed and initialized. 2. Verify that the pabx/ps connector is connected into the dc power connection of the ps500 ac power supply. See figure 3-2 on page 3-5 . 3. If r...

  • Page 143: 3.5

    Initial power-up tests 3-23 i/o cabl e in st all a ti on 3 3.5 i/o cable installation the i/o cables are connected to the cage when all the corresponding cards are in place. I/o connections are divided between circuit cards and auxiliary equipment. The coral ipx 500 system i/o cables connection proc...

  • Page 144

    3-24 coral ipx 500 installation manual i/o cabl e in st all a ti on 3 0 the mdfipx unit that is supplied by the manufacturer includes one of the configurations defined in table 2-7 on page 2-36, mdfipx configurations : 1. For mdfipx units supplied without i/o cables (which are supplied by the custom...

  • Page 145

    Initial power-up tests 3-25 i/o cabl e in st all a ti on 3 figure 3-5 mdfipx i/o cables ready for connection to coral ipx 500 cage.

  • Page 146

    3-26 coral ipx 500 installation manual i/o cabl e in st all a ti on 3 figure 3-6 champ fastening to top section of the cage.

  • Page 147

    Initial power-up tests 3-27 i/o cabl e in st all a ti on 3 figure 3-7 mdfipx connector configuration right view champ connections mdf krone block connections.

  • Page 148

    3-28 coral ipx 500 installation manual i/o cabl e in st all a ti on 3 0 1. Determine the route of input/output (i/o) cables from the mdf to the i/o connectors of the relevant peripheral cards. If required, measure the longest distance from an i/o connector on the card cage to the corresponding cable...

  • Page 149

    Initial power-up tests 3-29 i/o cabl e in st all a ti on 3 figure 3-8 mdf connector configuration left view.

  • Page 150

    3-30 coral ipx 500 installation manual i/o cabl e in st all a ti on 3 0 1. The auxiliary connection is relevant for the main cage only. The connections to the auxiliary optional equipment are performed with a connector located at the top left of the main cage. For more information, see page 9-11, au...

  • Page 151: 3.6

    Initial power-up tests 3-31 inst alla tio n w ra p -u p 3 3.6 installation wrap-up this section describes how to close all equipment and prepare the system for normal operation. 1. Assemble the top cover of the cage. See page 6-12, assembling the top cover . 2. Assemble the cage front door. See page...

  • Page 152: Notes:

    3-32 coral ipx 500 installation manual inst alla tio n w ra p -u p 3 notes:.

  • Page 153: Chapter

    Coral cor coral ipx 500 installation manual chapter 4 software installation procedure 4.1 generic feature software ................................... 4-1 4.2 system database control ..................................4-5 4.3 mcp-ipx status display codes........................4-13.

  • Page 155: 4.1

    Software installation procedure 4-1 generic fea tu re sof tw a re up g rade 4 4.1 generic feature software upgrade 0 the coral ipx 500 is delivered to the site with factory-loaded software on imc8 card. The imc8 card is a 8mb flash memory card. See page 8-23, imc8 card for details. The imc8 card is ...

  • Page 156

    4-2 coral ipx 500 installation manual generic feat ur e soft w ar e upg rade 4 0 0 use fmprog version 5.Xx and above. Otherwise, the coral will not initialize. The upgrade of the generic feature software involves three main steps: 1. Installing the fmprog-utility (version 5.Xx and later) 2. Extracti...

  • Page 157

    Software installation procedure 4-3 generic fea tu re sof tw a re up g rade 4 0 this section provides instructions on inserting the imc8 flash memory card after it has been programmed with a new or upgraded software version. Creating a binary backup of the database before installing an imc8 card wit...

  • Page 158

    4-4 coral ipx 500 installation manual generic feat ur e soft w ar e upg rade 4 the second message may appear after two or three minutes, following several short messages that appear during system start-up: ccs is on the air...... (root) ccs xx.Xx.Xx copyright (c) 2001-xxxx............... Name - (sit...

  • Page 159: 4.2

    Software installation procedure 4-5 system d a ta base co n tr o l 4 4.2 system database control during normal system operation, the configuration database may be saved to a file on the imc8 card for permanent storage. The system may also be programmed to save the database to imc8 automatically on a...

  • Page 160: Saving to Imc8

    4-6 coral ipx 500 installation manual system d a ta base con tr o l 4 0 the database save feature allows the system database to be copied to imc8 at any time. The procedure is as follows: 1. Verify that the system time and date are correct (press control-t to check). Update through the time and date...

  • Page 161

    Software installation procedure 4-7 system d a ta base con tr o l 4 when at least one of the flags cannot be recognized, the following message will appear: corrupted dbs 5. When the backup is valid, the save operation continues with: caution: previous backup will be lost: proceed with backup (y/n) [...

  • Page 162

    4-8 coral ipx 500 installation manual system d a ta base con tr o l 4 0 a system database stored in imc8 can be loaded into the database memory on the mcp-ipx card at any time. Loading the database from imc8 generally takes several minutes. During this process, the coral system is non-operational. L...

  • Page 163

    Software installation procedure 4-9 system d a ta base con tr o l 4 b. Verify that the database is not corrupted (the system executes the checksum test procedure). If the procedure checking the database (dbs) retrieval conditions found the above conditions fulfilled, the following message will appea...

  • Page 164: Show File Information

    4-10 coral ipx 500 installation manual system d a ta base con tr o l 4 0 this option displays the list of backed up files stored on the imc8 card. From the database flash menu, press 2 to display the list of backed up files. The following prompt appears: execute (y/n)? - [n] type y . A report appear...

  • Page 165: Automatic Daily Backup

    Software installation procedure 4-11 system d a ta base con tr o l 4 0 the system configuration database can be automatically saved to a database file on the imc8 at a preset time each day. Use autobackup to automatically save the database. During automatic daily backup the database is saved to db0....

  • Page 166: Erasing Flash Memory

    4-12 coral ipx 500 installation manual system d a ta base con tr o l 4 0 this function enables erasing of backed up files stored on the imc8 card: 1. From the database menu, press 4 to erase the flash memory. The following prompt appears: proceed with erase (0/1/a/n/) ? [n] 2. Specify one of the opt...

  • Page 167: 4.3

    Software installation procedure 4-13 mc p-ipx s tat us displ a y cod es numeric s ta tus di sp lay 4 4.3 mcp-ipx status display codes numeric status display the mcp-ipx numeric status display indicates various operating and error states of the coral ipx 500 system, and it can provide valuable inform...

  • Page 168

    4-14 coral ipx 500 installation manual mc p-ipx s tat us displ a y cod es numeric s ta tus di sp lay 4 other error symptoms will assist maintenance personnel in finding the cause of the fault. Table 4-1 mcp-ipx status display code pressing reset interrupts all calls in progress and causes the system...

  • Page 169: Chapter

    Coral cor coral ipx 500 installation manual chapter 5 external connections 5.1 main distribution frame (mdf) .......................... 5-1 5.2 external equipment ............................................. 5-3 5.3 protection devices ............................................. 5-9 5.4 power fail...

  • Page 171: 5.1

    External connections 5-1 ma in d istribu tio n frame (md f ) 5 5.1 main distribution frame (mdf) this chapter describes the mdf and the pinout connections to the cage and external equipment. For hardware installation instructions, refer to hardware installation procedure . The mdf may be factory sup...

  • Page 172: Tip:

    5-2 coral ipx 500 installation manual ma in d istribu tio n frame (md f ) 5 in some cases, connections are made via rj-45 or da-15s connectors onto the top panel of a coral circuit card (for example, the ugwipx, udtipx, pri-23ipx, t1ipx, pri-30ipx, and 30tipx digital trunk interfaces). See page 5-73...

  • Page 173: 5.2

    External connections 5-3 ext ernal eq uipm ent 5 5.2 external equipment 0 wired stations connections to coral ipx 500 system station equipment are established by cross-connecting the station circuit from the appropriate coral ipx 500 i/o cable punch block to the corresponding station wiring punch bl...

  • Page 174

    5-4 coral ipx 500 installation manual ext ernal eq uipm ent 5 table 5-1 station interface wire pair requirements station interface card type supported station equipment pairs required 8slsipx, 16slsipx standard single-line telephone (slt) sets, slt sets with message waiting lamp 1 8sftipx, 16sftipx ...

  • Page 175

    External connections 5-5 ext ernal eq uipm ent 5 figure 5-2 modular station jack wiring diagram 6 5 4 3 2 1 pin 2 black dt (dtr), flexset/dkt + 48vdc pin 2 black dt (dtr), flexset/dkt + 48vdc pin 2 black dt (dtr), flexset/dkt + 48vdc pin 3 red ar (drt), [r] pin 3 red ar (drt), [r] pin 3 red ar (drt)...

  • Page 176

    5-6 coral ipx 500 installation manual ext ernal eq uipm ent 5 wireless and voip stations the flexair handset and the flexset-ip 280s models are not connected via the mdf . Related documentation for further information about coral voice terminals not covered by this section, consult the following doc...

  • Page 177: Trunk Circuits

    External connections 5-7 ext ernal eq uipm ent 5 generally, trunk circuits are connected to the coral ipx 500 system simply by cross-connecting the trunk interface circuit of a coral ipx 500 trunk card to the point of demarcation where the trunk circuits from the telephone utility company (telco) ap...

  • Page 178: Auxiliary Connections

    5-8 coral ipx 500 installation manual ext ernal eq uipm ent 5 table 5-2 lists the auxiliary connection pinout. The auxiliary connector is located at the top left of the coral ipx 500m main cage. Connections to the auxiliary are made with a standard 25 pair input/output champ tm connector. Individual...

  • Page 179: 5.3

    External connections 5-9 pr otection devices 5 5.3 protection devices 0 . Lightning and over-voltage arrestors are used to protect the user and the system from lightning and other electrical hazards that may occur on external circuits connected to the system. Any cable that passes through open air, ...

  • Page 180

    5-10 coral ipx 500 installation manual pr otection devices 5 generally, leased or switched circuit facilities provided by the local telephone utility company are equipped with primary protection devices installed with the circuit. However, privately owned aerial or buried cable feeding from one buil...

  • Page 181

    External connections 5-11 pr otection devices 5 table 5-4 telephone circuit secondary protection device specifications device type specification measurement surge/impulse protector clamp points dc. 2kv/s 100v/ µ s 10kv/ µ s 230vdc max. 230vdc max. 100vdc max 30vdc max. Response time 5ns max. Series ...

  • Page 182

    5-12 coral ipx 500 installation manual pr otection devices 5 to prevent serious damage to the coral ipx 500 system, the analog trunk and station circuits, whose cables are laid outside the building, must be protected from the electrical peaks caused by lightning. Magazine 10 surge arrestors must be ...

  • Page 183

    External connections 5-13 pr otection devices 5 figure 5-5 connecting surge arrestor magazine to the mdfipx step 1 mount a magazine 10 surge arrestor on each mdf disconnection strip used for telephone circuit cross-connections. (cn# 7244-3190009) use a surge voltage protector for cross-connected tel...

  • Page 184: Notes:

    5-14 coral ipx 500 installation manual pr otection devices 5 notes:.

  • Page 185: 5.4

    External connections 5-15 p o wer f a il (p f) t ra nsfer ci rc ui ts 5 5.4 power fail (pf) transfer circuits with the installation of trunk cards to support the pf (power fail) transfer option, four trunks per trunk card (two trunks per 8tpfsl) may be directed to station sets if power to the coral ...

  • Page 186: Database Programming

    5-16 coral ipx 500 installation manual po wer fa il ( p f) t ra n sfer cir cuit s 5 0 to use the power fail transfer features of the coral system, the station dial numbers, to which power fail trunks are transferred, must be entered in the system database. Refer to power fail trunk definition in cha...

  • Page 187

    External connections 5-17 po wer fa il ( p f) t ra n sfer cir cuit s 5 figure 5-6 power fail wiring to single-line (500/2500) telephone set lightning protection trunk circuit with pf option co ra l i p x 5 0 0 s yst em re d r (ri n g ) g reen t ( ti p ) modular jack ground start button 500/2500 sing...

  • Page 188: Notes:

    5-18 coral ipx 500 installation manual po wer fa il ( p f) t ra n sfer cir cuit s 5 notes:.

  • Page 189: 5.5

    External connections 5-19 dat a com m uni cati on ports rs-232 e 5 5.5 data communication ports rs-232e the coral ipx 500 switching system is capable of switching digital data information as well as voice signals. Coral ipx 500 system data communication devices are available for packet switched data...

  • Page 190

    5-20 coral ipx 500 installation manual dat a com m uni cati on ports rs-232 e 5 table 5-5 dkt2000 with apa/apdl rs-232e (v.24) interface module pin functions figure 5-7 flexset 80 (gkt ) or flexset 280s/apdl with apa or pex+apa rs-232e (v.24) pin functions pin designation pin # function transmit dat...

  • Page 191: 5.6

    External connections 5-21 md fipx un its su ppl ied b y the man u fact ur er 5 5.6 mdfipx units supplied by the manufacturer 0 the mdfipx can be supplied in any one of the configurations provided in table 5-6 . The mdfipx is installed in some countries only. For more information, please contact the ...

  • Page 192

    5-22 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 figure 5-8 1mdfipx cover figure 5-9 2mdfipx cover.

  • Page 193

    External connections 5-23 md fipx un its su ppl ied b y the man u fact ur er 5 0 figure 5-10 and figure 5-11 illustrate the i/o cable connections between the mdfipx and the i/o connectors. The top two blocks are connected to slot #1 and the bottom two blocks are connected to the auxiliary connector ...

  • Page 194

    5-24 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 figure 5-11 coral ipx 500 expansion cage connected to mdfipx.

  • Page 195

    External connections 5-25 md fipx un its su ppl ied b y the man u fact ur er 5 table 5-7 main cage - champ to krone connections and color codes bl- blue w - white o - orange gn - green br - brown gy - grey main cage block slot krone block pairs 1 2 3 4 5 6 7 8 9 10 1 1 bl w o w gn w br w gy w bl/w w...

  • Page 196

    5-26 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 table 5-8 expansion cage - champ to krone connections and color codes bl- blue w - white o - orange gn - green br - brown gy - grey expansion cage block slot krone block pairs 1 2 3 4 5 6 7 8 9 10 1 1 bl w o ...

  • Page 197

    External connections 5-27 md fipx un its su ppl ied b y the man u fact ur er 5 0 removing the mdfipx cover 1. Pull mdfipx cover upwards, as shown in figure 5-12 . 2. Release flaps from grooves. 3. Remove mdfipx cover. Figure 5-12 1mdfipx cover removal 3 removing and closing the mdfipx cover release ...

  • Page 198

    5-28 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 closing the mdfipx cover 1. Insert the top flaps of the mdfipx cover into the mating grooves of the mdf frame. 2. Push the mdfipx cover down until it snaps shut. Figure 5-13 1mdfipx cover closing step step 2 ...

  • Page 199

    External connections 5-29 md fipx un its su ppl ied b y the man u fact ur er 5 0 the mdfipx supplied by the manufacturer is mounted onto the wall, as described on page 2-36, main distribution frame (mdf) mounting and installation . Installation of the mdfipx unit includes the following stages: prepa...

  • Page 200

    5-30 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 0 the mdfipx kit includes krone blocks and champ connectors provided in separate bags. There are two configurations: 1mdfipx for ipx 500m and 500x 2mdfipx for ipx 500m and 500x this section describes how to a...

  • Page 201

    External connections 5-31 md fipx un its su ppl ied b y the man u fact ur er 5 attaching the disconnecting strips: the krone block disconnecting strip is attached to the mdf frame by easing it onto the two metal tabs protruding from the mdf frame. The disconnecting strip will snap into place when in...

  • Page 202

    5-32 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 figure 5-15 mdfipx field assembly i/o cables opening 1 step 2 3 step step mount krone blocks onto frame. Insert wires into first krone block with punch tool as specified. 4 step route i/o cables through mdf o...

  • Page 203

    External connections 5-33 md fipx un its su ppl ied b y the man u fact ur er 5 figure 5-16 i/o cables routed from the coral ipx 500 cage to the mdfipx champ connections to expansion top card cage mdf krone connections 1 2 3 4 5 6 7 8 10 9 ipx 500x champ connections to main top card cage 1 2 3 4 5 6 ...

  • Page 204: Notes:

    5-34 coral ipx 500 installation manual md fipx un its su ppl ied b y the man u fact ur er 5 notes:.

  • Page 205: 5.7

    External connections 5-35 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 5.7 peripheral card with champ connections for coral interface cards the following tables display the pinout, the wire colors, and the signals of the i/o champ connectors for each card and each ...

  • Page 206

    5-36 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 0 peripheral cards index table 5-10 through table 5-10 display the pinout connection directly on the champ/card connection for all currently available peripheral cards. 1 direct pin...

  • Page 207

    External connections 5-37 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-10 champ 50 connector - wired station interface card pinout pin 8slsipx 16slsipx 8sftipx, 16sftipx 25 50 st0 sr0 st0 sr0 b0 a0 b0 a0 24 49 st1 sr1 st1 sr1 b1 a1 b1 a1 23 48 st2 sr2 st2 s...

  • Page 208

    5-38 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-11 champ 50 connector - trunk interface card pinout * stt, str, sct and scr are power failure transfer connections. See section 5.4 on page 5-15 for power failure transfer w...

  • Page 209

    External connections 5-39 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-12 champ 50 connector - trunk interface card pinout (main cage slot# 1,2,3) * stt, str, sct and scr are power failure transfer connections. See section 5.4 on page 5 on page 5-15 for pow...

  • Page 210: Block 66 Mdf Connections

    5-40 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 peripheral cards index table 5-13 through table 5-15 display the pinout connection directly on the block 66 mdf connection for all currently available peripheral cards . 2 block 66 ...

  • Page 211

    External connections 5-41 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-13 block 66 mdf - wired station interface pinout pin/color 8slsipx 16slsipx 8sftipx 16sftipx 1/26 white/blue 2/27 white/orange 3/28 white/green 4/29 white/brown 5/30 white/slate 6/31 red...

  • Page 212

    5-42 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-14 block 66 mdf - trunk interface card pinout pin/color 4t-cipx, 4t-cidipx, 4tmr- pfipx 4temipx 8t-cipx, 8t-cidipx 4tbripx 8tbripx, 8tbrpipx 1/26 white/blue 2/27 white/orang...

  • Page 213

    External connections 5-43 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-15 block 66 mdf - trunk interface card pinout (main cage slot# 1,2,3) pin/color 4t-csl, 4t-cidsl, 4tpfsl, 4tmr- pf sl 4temsl 8tpfsl 8t-csl, 8t-cidsl 4tbrsl 4tbrpsl 8tbrsl, 8tbrpsl 1/26 w...

  • Page 214

    5-44 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 0 for detailed information about mdfipx units, refer to page 5-21, mdfipx units . Krone blocks krone blocks are provided with the mdfipx units. Krone blocks that are to be installed...

  • Page 215

    External connections 5-45 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 8t-c ipx table 5-23 on page 5-60 8t-cid ipx table 5-23 on page 5-60 4tbr sl table 5-28 on page 5-68 4tbrp sl table 5-28 on page 5-68 4t-c sl table 5-32 on page 5-72 4t-cid sl table 5-32 on page ...

  • Page 216

    5-46 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-16 8sftipx mdfipx pinout main cage - 8sftipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 b a b a b a b a b a b a b a b a 2 2 0 1 2 3 b a b a b a b a 3 2 ...

  • Page 217

    External connections 5-47 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 8sftipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 b a b a b a b a b a b a b a b a 2 2 0 1 2 3 b a b a b a b a 3 2 4 5 6 7 b a b a b a b a 4 3 0 1 2 3 4 5 6...

  • Page 218

    5-48 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-17 16sftipx mdfipx pinout main cage - 16sftipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 8 9 b a b a b a b a b a b a b a b a b a b a 2 1/2 10 11 12 13 ...

  • Page 219

    External connections 5-49 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 16sftipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 8 9 b a b a b a b a b a b a b a b a b a b a 2 1/2 10 11 12 13 14 15 0 1 2 3 b a b a b a b a b a b a b a ...

  • Page 220

    5-50 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-18 8slsipx mdfipx pinout main cage - 8slsipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 st sr st sr st sr st sr st sr st sr st sr st sr 2 2 0 1 2 3 st s...

  • Page 221

    External connections 5-51 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 8slsipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 st sr st sr st sr st sr st sr st sr st sr st sr 2 2 0 1 2 3 st sr st sr st sr st sr 3 2 4 5 6 7 st sr st ...

  • Page 222

    5-52 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-19 16slsipx mdfipx pinout main cage - 16slsipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 8 9 st sr st sr st sr st sr st sr st sr st sr st sr st sr st s...

  • Page 223

    External connections 5-53 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 16slsipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 5 6 7 8 9 st sr st sr st sr st sr st sr st sr st sr st sr st sr st sr 2 1/2 10 11 12 13 14 15 0 1 2 3 st sr st...

  • Page 224

    5-54 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-20 4temipx mdfipx pinout main cage - 4temipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 ett etr ert err e sg m sb ett etr ert err e sg m sb ett etr ert err 2 1/2 ...

  • Page 225

    External connections 5-55 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 4temipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 ett etr ert err e sg m sb ett etr ert err e sg m sb ett etr ert err 2 1/2 2 3 0 e sg m sb ett etr ert err e sg m sb...

  • Page 226

    5-56 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-21 4t-cipx, 4t-cidipx, 4tmr-pfipx mdfipx pinout main cage - 4t-cipx, 4t-cidipx, 4tmr-pfipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 tt tr stt str sct scr tt tr ...

  • Page 227

    External connections 5-57 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 * stt, str, sct and scr are power failure transfer connections. See page 5-15, power fail (pf) transfer circuits , earlier in this chapter. Expansion cage - 4t-cipx, 4t-cidipx, 4tmr-pfipx block ...

  • Page 228

    5-58 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-22 4twlipx mdfipx pinout main cage - 4twlipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 tt tr tt tr tt tr 2 1/2 3 0 tt tr tt tr 3 2 1 2 3 tt tr tt tr tt tr 4 3 0 ...

  • Page 229

    External connections 5-59 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 4twlipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 tt tr tt tr tt tr 2 1/2 3 0 tt tr tt tr 3 2 1 2 3 tt tr tt tr tt tr 4 3 0 1 tt tr tt tr 5 3 2 3 tt tr tt tr 6 4 0 1...

  • Page 230

    5-60 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-23 8t-cipx, 8t-cidipx mdfipx pinout for main cage main cage - 8t-cipx, 8t-cidipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 tt tr tt tr tt tr stt str sct str ...

  • Page 231

    External connections 5-61 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 8t-cipx, 8t-cidipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 tt tr tt tr tt tr stt str sct scr tt tr stt str sct scr tt tr stt str 2 1/2 4 5 6 7 0 1 2 sct scr tt...

  • Page 232

    5-62 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-24 4tbripx mdfipx pinout main cage - 4tbripx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(...

  • Page 233

    External connections 5-63 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage -- 4tbripx slot block krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) 2 2 0 1 t(-) t(+) r(+) r(-) t(-)...

  • Page 234

    5-64 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-25 8tbripx, 8tbrpipx mdfipx pinout main cage - 8tbr-ipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-)...

  • Page 235

    External connections 5-65 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 expansion cage - 8tbr-ipx block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) t(-) t(+) r(+) r(-) 2 1/2 5 6 ...

  • Page 236

    5-66 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-26 8tbrsl, 8tbrpsl mdfipx pinout for main cage slot# 1,2,3 main cage - 8tbr-sl, 8tbrp-sl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 t(-) t(+) r(+) r(-) t(-) t...

  • Page 237

    External connections 5-67 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-27 4temsl mdfipx pinout for main cage slot# 1,2,3 main cage - 4temsl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 ett etr ert err e sg m sb ett etr ert err e sg m sb ett etr ert...

  • Page 238

    5-68 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-28 4tbrsl, 4tbrpsl mdfipx pinout for main cage slot# 1,2,3 main cage - 4tbr-sl, 4tbrp-sl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 t(-) t(+) r(+) r(-) t(-) t(+...

  • Page 239

    External connections 5-69 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-29 4twlsl mdfipx pinout for main cage slot# 1,2,3 main cage - 4twlsl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 tt tr tt tr tt tr 2 1/2 3 0 tt tr tt tr 3 2 1 2 3 tt tr tt tr t...

  • Page 240

    5-70 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-30 8tpfsl mdfipx pinout for main cage slot# 1,2,3 main cage - 8tpfsl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 tt tr tt tr tt tr tt tr tt tr stt str 2 1/2 4 ...

  • Page 241

    External connections 5-71 peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-31 8t-csl, 8t-cidsl mdfipx pinout for main cage slot# 1,2,3 main cage - 8t-csl, 8t-cidsl block slot krone block 1 2 3 4 5 6 7 8 9 10 1 1 0 1 2 3 4 tt tr tt tr tt tr stt str sct scr tt tr...

  • Page 242

    5-72 coral ipx 500 installation manual peri pheral car d wit h cha m p co nnect ions for co ra l interfa ce c a rd s 5 table 5-32 4t-csl, 4t-cidsl, 4tmr-pfsl mdfipx pinout for main cage slot# 1,2,3 * stt, str, sct and scr are power failure transfer connections. See page 5-15, power fail (pf) transfe...

  • Page 243: 5.8

    External connections 5-73 per ipheral ca rd wi th rj- 4 5 da- 1 5s c o nnec tions for c o ra l interf a ce c a rd s 5 5.8 peripheral card with rj-45 da-15s connections for coral interface cards 0 the i/o connections of the following interface cards are performed via cables connected to their top pan...

  • Page 244

    5-74 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 0 the external network connections to the pri-23/30sl and pri-23/30ipx digital circuit are made via one of the two connectors available at the top panel: da-15s, 15 pin femal...

  • Page 245

    External connections 5-75 peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 figure 5-18 pri-23, pri-30 da-15s interface connector pin assignment tx b rx b rx a tx a gnd shield -48 vdc 3 8 1 15 13 11 9 da-15s d-type connector.

  • Page 246

    5-76 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 figure 5-19 pri (layout udtipx) interface connections to the pstn/ltu/csu pin # pin 11 rxb pin 3 rxa pin 8 shield pin 9 txb pin 1 txa pin 2,4,5,6, 7,10,12,14 not used pin 13 ...

  • Page 247

    External connections 5-77 peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 pri i/o cables two factory pre-wired cables are available for pri-23/30sl and pri-23/30ipx i/o connections: pri-23/30/sl/ipx to ltu/csu cable, towards pstn, cn# 7244-6914056 . Pri-23/30/s...

  • Page 248

    5-78 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 0 the external network connections to the t1sl, t1ipx, 30tsl, and 30tipx digital circuit are made via one of the two connectors available at the top panel: da-15s, 15 pin fem...

  • Page 249

    External connections 5-79 peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 figure 5-22 t1 and 30t da-15s interface connector pin assignment tx ring rx ring rx tip tx tip gnd shield -48 vdc 3 8 1 15 13 11 9 da-15s d-type connector.

  • Page 250

    5-80 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 figure 5-23 t1 and 30t interface connections to the pstn/ltu/csu pin # pin 11 rx ring pin 3 rx tip pin 8 shield pin 9 tx ring pin 1 tx tip pin 2,4,5,6, 7,10,12,14 not used pi...

  • Page 251: Ugwipx

    External connections 5-81 peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 0 table 5-36 and figure 5-24 show the interface connections of the pins on the ugwipx rj-45 connectors. Figure 5-25 describes the connection from the top panel to the lan/wan. Table 5-36 ...

  • Page 252

    5-82 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 figure 5-25 ugwipx card connection to the lan/wan lan / wan pin # pin 1 tx(+) pin 2 tx(-) pin 3 rx(+) pin 4 not used pin 5 not used pin 6 rx(-) pin 7 not used pin 8 not used ...

  • Page 253: 8Skkipx and 8Skksl Cards

    External connections 5-83 peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 0 the external rbs (radio base station) connections to the 8skksl and 8skkipx digital circuit are made via one of the two connectors available at the top panel: table 5-37 8skksl, 8skkipx...

  • Page 254: Notes:

    5-84 coral ipx 500 installation manual peri pheral car d wit h rj-4 5 da-1 5s co nnect ions for co ra l interfa ce c a rd s 5 notes:.

  • Page 255: Chapter

    Coral cor coral ipx 500 installation manual chapter 6 cage description 6.1 general system description and installation ......6-1 6.2 coral ipx 500m main cage ..............................6-21 6.3 coral ipx 500x expansion cage ......................6-33 6.4 system configuration options.................

  • Page 257: 6.1

    Coral ipx 500 installation manual 6-1 general system d escrip tio n an d in st all a ti on 6 6.1 general system description and installation this section describes the coral ipx 500 cage components. Upon completing this section, you will be familiar with cage components and the general procedure of ...

  • Page 258

    6-2 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 cage door, top cover, and ventilation holes. The coral ipx 500 includes a kit that is ordered separately by the customer for cages that are to be mounted in a rack. Figure 6-2 displays the rack configuration...

  • Page 259

    Cage description 6-3 general system d escrip tio n an d in st all a ti on 6 rear panel the rear panel (see figure 6-3 ) includes: ventilation holes on the lower section to allow the inflow of cool air. Do not block the rear panel of the cage, as this area must be left clear to allow the inflow of co...

  • Page 260

    6-4 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 side panels the left panel of the cage includes an opening for routing the expansion and auxiliary cables. The left panel of the cage also includes door fasteners and ventilation holes. In wall-mounted confi...

  • Page 261

    Cage description 6-5 general system d escrip tio n an d in st all a ti on 6 top cover the top cover is installed above the top section. A space of 2u must be maintained above the top cover and the equipment above it for maintenance purposes. See page 2-3, space requirements . Bottom panel the bottom...

  • Page 262

    6-6 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 door the door on the front of the cage (see figure 6-6 and figure 6-7 ) protects internal circuitry during normal operation from damage and rfi while still allowing access to the interior for maintenance act...

  • Page 263: Accessing The Cage Interior

    Cage description 6-7 general system d escrip tio n an d in st all a ti on 6 0 opening the door 1. Unfasten the two locking studs on the left side of the door with a straight blade screwdriver (half a turn counter-clockwise). 2. Pull the door open using moderate force. The door opens to 110 ° . Figur...

  • Page 264

    6-8 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 closing the door 1. Verify that all cards and power supply unit are properly installed and that all cables are properly connected. 2. Verify that the top section of the cage is free of objects (with the exce...

  • Page 265

    Cage description 6-9 general system d escrip tio n an d in st all a ti on 6 removing the door 1. Open the door to an angle of at least 110°. 2. Disconnect the grounding wire from the door by pulling the connector at the end of the grounding wire from the connection on the door. See figure 6-7 page 6...

  • Page 266

    6-10 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 assembling the door 1. Align the door hinge mounts above the cage hinges, such that the door and the cage form an angle that is greater than 110°. 2. Lower the door onto the hinges and push down until the d...

  • Page 267

    Cage description 6-11 general system d escrip tio n an d in st all a ti on 6 removing the top cover 1. Open the door. See page 6-7, opening the door . 2. Insert a slotted screwdriver between the cover and the top section of the cage and twist until the cover is released from the cage. 3. Lift and re...

  • Page 268

    6-12 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 assembling the top cover 1. Open the door. See page 6-7, opening the door . 2. Insert the groove at the end of the top panel over the mating pin at the left and right side of the cage near the rear panel. S...

  • Page 269: Cage Interior

    Cage description 6-13 general system d escrip tio n an d in st all a ti on 6 0 the cage houses the power supply unit and all peripheral and control cards. On the left side of the cage, the ps500 power supply unit is installed. The remaining cards displayed are either peripheral cards or control card...

  • Page 270

    6-14 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 card slots guides at the top and bottom of the card cage align the cards and assemblies during their insertion with multi-pin connectors mounted on the card cage backplane. The guides and associated connect...

  • Page 271

    Cage description 6-15 general system d escrip tio n an d in st all a ti on 6 figure 6-15 front and internal views of empty coral ipx 500m cage without top cover figure 6-16 front and internal views of empty coral ipx 500x cage without top cover eight peripheral card connectors configuration jumpers ...

  • Page 272: Top Section

    6-16 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 0 00 the top section (see figure 6-14 on page 6-13 , figure 6-17 , and figure 6-18 ) includes the openings for the i/o cable connections (champ tm and rj-45), openings for the ac power receptacle and dc pow...

  • Page 273

    Cage description 6-17 general system d escrip tio n an d in st all a ti on 6 refer to the specific card tables in chapter 5, external connections for i/o connector pin assignments. There are no i/o connector pin assignments for either the power supplies or the common control cards. Expansion connect...

  • Page 274

    6-18 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 figure 6-18 top section of coral ipx 500 cage with cards installed expansion connection auxiliary connection i/o cable connections mdfipx ipx 500 cage ac power connector opening dc power connector opening.

  • Page 275: Safety Labels

    Cage description 6-19 general system d escrip tio n an d in st all a ti on 6 0 0 there are five safety labels located on the ipx 500 cage that provide safety information pertaining to the ipx 500 cage. Power rating label one power rating label is located on the rear panel of the cage. This label rem...

  • Page 276

    6-20 coral ipx 500 installation manual general system d escrip tio n an d in st all a ti on 6 warning label two warning labels are located on the inside of the coral ipx 500 door and inside the cage beneath the card slots facing outwards. See figure 6-20 . The coral ipx 500 cage is equipped with an ...

  • Page 277: 6.2

    Coral ipx 500 installation manual 6-21 coral ipx 500 m ma in ca ge descript ion 6 6.2 coral ipx 500m main cage description this section describes the main features of the coral ipx 500m (main) cage. For a general description of the coral ipx 500 system, see page 6-1, general system description and i...

  • Page 278

    6-22 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 table 6-1 coral ipx 500m card slot configuration for main cage slot contains slot 1-3 peripheral cards any xxxipx, xxxsl, or xxx200 cards note: 8f8ssl, 8d8ssl, 8sftsl, 16sftsl, 8sdtsl, 16sdtsl, 8slssl and 16slssl cards...

  • Page 279

    Cage description 6-23 coral ipx 500 m ma in ca ge descript ion 6 figure 6-21 coral ipx 500m card cage (front view) 1 6 2 7 3 8 4 5 power supply ps500 ac / dc ipx sl and peripheral cards digital trunk ipx peripheral cards control cards imc8 mcp-ipx optional dbx optional cla m c p - i p x auxiliary co...

  • Page 280: Backplane Description

    6-24 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 0 the backplane of the main cage includes the eight peripheral card connections and one control card connection, service card components, and the configuration jumpers. The backplane is displayed in figure 6-22 . Figur...

  • Page 281: Configuration Jumpers

    Cage description 6-25 coral ipx 500 m ma in ca ge descript ion 6 0 the configuration jumpers of the main cage: configure the main cage to house the primary and/or secondary synchronization card. Designate whether the system uses internal or external music. Activate and deactivate the receive and tra...

  • Page 282

    6-26 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 digital trunk synchronization slots two synchronization sources may be defined for the coral ipx 500 system. One serves as the primary source, and the other serves as a secondary synchronization signal source. A total ...

  • Page 283

    Cage description 6-27 coral ipx 500 m ma in ca ge descript ion 6 music (m1) to external or internal the system music source m1 may be either from an internal or an external source. Figure 6-24 displays the jumper settings for the source type. For further information, see page 9-63, configuring the m...

  • Page 284

    6-28 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 remote maintenance modem - enable or disable the coral ipx 500 modem can be configured to enable or disable. This is useful when maintenance from a remote workstation is necessary. During normal system operation, it is...

  • Page 285

    Cage description 6-29 coral ipx 500 m ma in ca ge descript ion 6 kb1, kb2, kb3 - rs-232 data serial port handshaking is the process whereby two communicating devices acknowledge and recognize each other and open channels for communication. The coral ipx 500 system can be managed by three local works...

  • Page 286

    6-30 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 0 when more than one cage is present in the system, the main cage includes one port 50-pin female connection for this purpose and it is used to connect to the first expansion cage. See figure 6-21on page 6-23 and figur...

  • Page 287: Auxiliary Connector

    Cage description 6-31 coral ipx 500 m ma in ca ge descript ion 6 0 the auxiliary connector is located beneath the expansion connector, see figure 6-21 on page 6-23 and figure 6-28 . The auxiliary connector provides three rs-232 interfaces, music, paging, and relay circuits. Table 6-3 provides the pi...

  • Page 288: Notes:

    6-32 coral ipx 500 installation manual coral ipx 500 m ma in ca ge descript ion 6 notes:.

  • Page 289: 6.3

    Coral ipx 500 installation manual 6-33 coral ipx 500 x exp ansio n cag e descri pti o n 6 6.3 coral ipx 500x expansion cage description this section describes the main features of the coral ipx 500x (expansion) cage. For a general description of the coral ipx 500 system, see page 6-1, general system...

  • Page 290

    6-34 coral ipx 500 installation manual coral ipx 500 x exp ansio n cag e descri pti o n 6 figure 6-29 coral ipx 500x card cage (front view) 1 6 2 7 3 8 4 9 5 10 power supply ps500 ac / dc ipx peripheral cards expansion connectors digital trunk prm sync i /o s l ot sec sync i /o slot.

  • Page 291: Backplane Description

    Cage description 6-35 coral ipx 500 x exp ansio n cag e descri pti o n 6 0 the only feature that distinguishes the expansion cage from the main cage is the backplane. The backplane of the expansion cage includes the ten peripheral card connections, two expansion connections, service card components,...

  • Page 292: Configuration Jumpers

    6-36 coral ipx 500 installation manual coral ipx 500 x exp ansio n cag e descri pti o n 6 0 the configuration jumpers of the expansion cage: define the cage that houses the primary and/or secondary synchronization card. Designates the cage number within the system (shelf 1 or shelf 2) table 6-5 disp...

  • Page 293

    Cage description 6-37 coral ipx 500 x exp ansio n cag e descri pti o n 6 expansion shelf number the term “shelf” is used in this section in order to retain consistency with program interface terminology. The terms “shelf” and “cage” are identical. Each peripheral card must be recognized by the main ...

  • Page 294

    6-38 coral ipx 500 installation manual coral ipx 500 x exp ansio n cag e descri pti o n 6 digital trunk synchronization slots two synchronization sources may be defined for the coral ipx 500 system. One serves as the primary source, and the other serves as a secondary synchronization signal source. ...

  • Page 295: Connections to Other Cages

    Cage description 6-39 coral ipx 500 x exp ansio n cag e descri pti o n 6 0 the expansion cage includes two serial port 50-pin female connections for connecting to other cages. See figure 6-29 on page 6-34 and figure 6-33 below . The connection is made with an h500-1 expansion cable with a d-type 50-...

  • Page 296: Notes:

    6-40 coral ipx 500 installation manual coral ipx 500 x exp ansio n cag e descri pti o n 6 notes:.

  • Page 297: 6.4.

    Coral ipx 500 installation manual 6-41 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 6.4. System configuration options coral ipx 500 this chapter describes the layout and configuration of the coral ipx 500 system. For a general description of the coral ipx 500 cage, see page 6-1, general syst...

  • Page 298

    6-42 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 expansion cage (ipx 500x) the expansion cage may house ten universal peripheral special form-factor cards. These card types are described in detail in the coral service and peripheral cards manual , and chapt...

  • Page 299

    Cage description 6-43 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-34 coral ipx 500 system with one cage (ipx 500m) 1 power supply 8 universal i/o slots common control coral ipx 500m main cage * special form-factor “ipx” cards *.

  • Page 300

    6-44 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-35 system with two cages (ipx 500m and ipx 500x) coral ipx 500m main cage coral ipx 500x expansion cage 2 power supplies common control 18 universal i/o slots * special form-factor “ipx” cards *.

  • Page 301

    Cage description 6-45 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-36 system with three cages (ipx 500m, and two ipx 500x cages) 3 power supplies common control 28 universal i/o slots coral ipx 500x 2nd expansion coral ipx 500x 1st expansion coral ipx 500m main cage * special form-f...

  • Page 302

    6-46 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-37 system with two cages (ipx 500m and ipx 800x) 1 power supply ps19 1 power supply ps500 common control 11 coral universal i/o slots 1 shared service slot coral ipx 800x expansion cage coral ipx 500...

  • Page 303

    Cage description 6-47 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-38 system with three cages (ipx 500m ,ipx 500x, and ipx 800x) 1 shared service slot 11 coral universal i/o slots 1 power supply ps19 coral ipx 500x 1st expansion coral ipx 500m main cage 2 power supplies ps500 common...

  • Page 304

    6-48 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-39 system with three cages (ipx 500m and two ipx 800x cages) 2 power supplies ps19 1 power supply ps500 common control 22 coral universal i/o slots 1 shared service slot px control card slot coral ip...

  • Page 305

    Cage description 6-49 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 0 the coral ipx 500 can be expanded in any one of the following configurations: one main ipx 500m cage and one ipx 500x expansion cage. See figure 6-40 . One main ipx 500m cage and two ipx 500x expansion cages. See figure 6-4...

  • Page 306

    6-50 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-40 connection between two ipx 500 cages (ipx 500m and 500x) male h500-1 c able main cage ipx 500m first expansion cage ipx 500x female female male.

  • Page 307

    Cage description 6-51 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-41 connection between three ipx 500 cages (ipx 500m and two 500x) male h500-1 c able main cage ipx 500m first expansion cage ipx 500x female female male female male h500-1 c able female second expansion cage ipx 500x...

  • Page 308

    6-52 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-42 connection between three cages (ipx 500m, 500x and 800x) male h500-1 cable main cage ipx 500m first expansion cage ipx 500x female female male female second expansion cage ipx 800x female (rear pa...

  • Page 309

    Cage description 6-53 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-43 connection between two cages (ipx 500m and 800x) male h500-1 cable main cage ipx 500m female female first expansion cage ipx 800x male (rear panel).

  • Page 310

    6-54 coral ipx 500 installation manual system c o nf igura tion opt ions c o ra l ipx 5 00 6 figure 6-44 connection between three cages (ipx 500m and two 800x) h500-1 c able ( see prev ious p age) main cage ipx 500m first expansion cage ipx 800x with px card male (rear panel) second expansion cage i...

  • Page 311

    Cage description 6-55 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 0 when installing a new coral ipx 500 system, it is recommended to take into account the timeslot (pcm highway) distribution among the cages and slots when planning the peripheral interface cards location. The coral ipx 500 s...

  • Page 312

    6-56 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 figure 6-45 coral ipx 500, pcm highway distribution peripheral service & group controller a3 b3 a2 b2 a1 b1 a4 b4 512 time slots ipx 500x 2nd expansion cage ipx 500m main cage 10 9 8 7 6 5 4 3 2 1 8 7 6 5 4 3...

  • Page 313

    Cage description 6-57 system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 0 general the coral ipx 800x expansion cage is a small, wall-mounted extension to the coral ipx 800m or coral ipx 500m cage. It supports any of the flexicom 300,400,5000,6000 and ipx 800,3000,4000 family standard shared servi...

  • Page 314

    6-58 coral ipx 500 installation manual system co nfi gurat ion opti ons co ra l ipx 5 0 0 6 when an ipx 800x expansion cage is used in an ipx 500 system there are situations where it is worthwhile to include an ipx 800x cage in an ipx 500 system: to allow the use of coral features not supported by c...

  • Page 315: Chapter

    Coral cor coral ipx 500 installation manual chapter 7 power supply 7.1 ps500 dc .........................................................7-1 7.2 ps500 ac.........................................................7-17 7.3 battipx battery pack.......................................7-35.

  • Page 317: 7.1

    Coral ipx 500 installation manual 7-1 ps5 00 dc power supply un it 7 7.1 ps500 dc power supply unit 0 the ps500 dc card’s component side power supply unit provides internal operating voltages for the coral ipx 500 system. The ps500 dc operates from a nominal input of –48vdc, typically supplied by an...

  • Page 318

    7-2 coral ipx 500 installation manual ps5 00 dc power supply un it 7 figure 7-1 ps500 dc front panel top and bottom captive screws used to secure the unit to the cage. These screws also ground the unit to the cage and safeguard the unit against malfunction. Feature description alarm power ps500 dc c...

  • Page 319

    Power supply 7-3 ps5 00 dc power supply un it 7 ps500 dc card layout the ps500 dc card’s component side is shown in figure 7-2 . Three components are described in the following table: feature description f2 dc power input fuse a 16a/250v, slow blow fuse that protects the unit’s voltage. See page 7-1...

  • Page 320

    7-4 coral ipx 500 installation manual ps5 00 dc power supply un it 7 figure 7-2 ps500 dc card layout -48vdc power input connector connection to backplane f2 dc power input fuse 16a/ s.B. 250v on off power switch.

  • Page 321: Circuit Description

    Power supply 7-5 ps5 00 dc power supply un it 7 0 figure 7-3 presents a block diagram of the ps500 dc power supply. Power input section the dc input includes a passive filter, inrush current, and an on/off power switch. The dc input is protected against reverse polarity. Dc output power the dc to dc...

  • Page 322

    7-6 coral ipx 500 installation manual ps5 00 dc power supply un it 7 figure 7-3 ps500 dc block diagramed current limit inrush current passive filter power on/off dc control circuit -48 vdc / 5a (see note below) +5vdc/13a power on/off indicator (green) +12vdc/2a -5vdc/0.15a alarm common common feedba...

  • Page 323

    Power supply 7-7 ps 5 00 dc power supply u n it 7 the ps500 dc does not employ ring and message generators for industry standard, single-line telephones (slt) station ports. These generators are provided in coral ipx 500 systems by the 8/16slsipx peripheral cards. The peripheral cards are described ...

  • Page 324: Installation

    7-8 coral ipx 500 installation manual ps5 00 dc power supply un it 7 0 the power supply unit is inserted into the coral ipx 500 cage in the extreme left slot of the card cage. Installing the power supply 1. Verify that the cage ground wire is connected and the ground nut is tightened. (see figure 7-...

  • Page 325

    Power supply 7-9 ps5 00 dc power supply un it 7 operating the ps500 dc follow these steps: 1. Verify that the cage ground wire is connected and the ground nut is tightened. (see figure 7-4 ). 2. Verify that the power switch is in the off position (turned downwards). 3. Verify that the two captive sc...

  • Page 326

    7-10 coral ipx 500 installation manual ps5 00 dc power supply un it 7 figure 7-4 ps500 dc power connections ground nut 48v dc power input connector dc power wires (to -48v dc power source) + ground wire (to master ground) - top view red wire black wire yellow/green wire.

  • Page 327

    Power supply 7-11 ps5 00 dc power supply un it 7 removing the power supply 1. Locate a desk or table top that can support 50lb (23kg). If the surface can be damaged by sharp objects, place a protective sheet of cardboard or similar material over the top surface. 2. Place an anti-static sheet (the ca...

  • Page 328: Troubleshooting

    7-12 coral ipx 500 installation manual ps5 00 dc power supply un it 7 0. Power supply failure generally results in the loss of one or more output voltages. However, protection circuitry in the power supply regulator may shut down a regulator due to a current overload caused by an external fault. The...

  • Page 329

    Power supply 7-13 ps5 00 dc power supply un it 7 ps500 dc fuse the ps500 dc employs one fuse (f2) to protect the cage circuitry and the dc main input. If the f2 fuse blows, the ps500 dc power green indicator and alarm red indicator do not illuminate. To replace the dc power input fuse within the ps5...

  • Page 330

    7-14 coral ipx 500 installation manual ps5 00 dc power supply un it 7 determining the cause of the alarm indicator 1. Turn the ps500 dc power switch off (turn the switch downwards). 2. Disconnect the expansion cable(s) connected to the relevant cage. 3. Remove all cards from the relevant cage so tha...

  • Page 331: Specifications

    Power supply 7-15 ps5 00 dc power supply un it 7 0 max. Ps500 dc (dc power supply) coral systems:.................................. Ipx 500m, 500x input:................................................ -40vdc to -60vdc, 10a max. Power consumption: ....................... Continuous 460w outputs: ......

  • Page 332: Notes:

    7-16 coral ipx 500 installation manual ps5 00 dc power supply un it 7 notes:.

  • Page 333: 7.2

    Coral ipx 500 installation manual 7-17 ps5 00 ac power supply un it 7 7.2 ps500 ac power supply unit 0 the ps500 ac power supply unit provides operating voltages for the coral ipx 500 system. Power source the ps500 ac operates from a nominal input of 100-240vac/47-63hz. During power failure, the uni...

  • Page 334: Ps500  Ac

    7-18 coral ipx 500 installation manual ps5 00 ac power supply un it 7 figure 7-5 ps500 ac front panel alarm power ps500 ac cat. No. 72440953300 on off caution! Hazard of electric shock. Disconnect power before servicing. Top captive screw alarm (red) indicator power (green) indicator power switch ha...

  • Page 335

    Power supply 7-19 ps5 00 ac power supply un it 7 ps500 ac card layout the ps500 ac card’s component side is shown in figure 7-6 . Five components are described in the following table: feature description battery pack connector connects the power supply unit to the battery pack. In the event of the a...

  • Page 336

    7-20 coral ipx 500 installation manual ps5 00 ac power supply un it 7 figure 7-6 ps500 ac circuit board backup battery connector ac power connector charger for backup batteries (under panel) connection to backplane f2 : intermodule fuse 16a / 250 v s.B. On off power switch.

  • Page 337: Circuit Description

    Power supply 7-21 ps5 00 ac power supply un it 7 0 the ps500 ac is an uninterrupted switch-mode power supply (usps). It contains a pulse-width modulated (pwm) switch-mode converter to produce the +5vdc, -5vdc, +12vdc, -48vdc operating voltages for the coral ipx 500 internal circuitry and 54vdc for b...

  • Page 338

    7-22 coral ipx 500 installation manual ps5 00 ac power supply un it 7 figure 7-7 ps500 ac block diagramed ac dc backup battery charger current limit dc dc control circuit -53v/5a +5v/13a power on/off indicator (green) common +12v/2a -5v/0.15a alarm low +5v, -5, +12 ps failure power on/off switch com...

  • Page 339

    Power supply 7-23 ps5 00 ac power supply un it 7 battery pack function in case of power failure the dc input consists of: battery wires, internal mounted battery fuse and charge current limit. The dc input consists of: battery pack wires and battery pack fuse. Should the ac power interrupt, and prop...

  • Page 340

    7-24 coral ipx 500 installation manual ps 5 00 ac power supply u n it 7 the green power indicator of a ps500 ac remains illuminated at the same time as the red alarm indicator. Alarm signals all the circuitry on the ps500 ac board is connected to an alarm circuit to provide the coral ipx 500 system ...

  • Page 341: Installation

    Power supply 7-25 ps5 00 ac power supply un it 7 0 the power supply unit is inserted into the coral ipx 500 cage in the extreme left slot. Installing the power supply 1. Verify that the cage ground wire is connected and the ground nut is tightened. (see figure 7-8 ). 2. Verify that the power switch ...

  • Page 342

    7-26 coral ipx 500 installation manual ps5 00 ac power supply un it 7 operating the ps500 ac follow these steps: 1. Verify that the cage ground wire is connected and the ground nut is tightened. (see figure 7-8 ). 2. Verify that the power switch is turned off (downwards). 3. Verify that the two capt...

  • Page 343

    Power supply 7-27 ps5 00 ac power supply un it 7 11. Verify that the green power indicator is lit, while the red alarm indicator is not lit 12. Turn the ps500 ac power switch off (downwards) before inserting or removing any common control cards in the system. Peripheral cards may be inserted or remo...

  • Page 344

    7-28 coral ipx 500 installation manual ps5 00 ac power supply un it 7 figure 7-8 ps500 ac power connections ground nut + ac power connector backup battery connector dc power wires (to battipx battery pack) ac power cable ground wire (to master ground) - top view red wire black wire yellow-green wire...

  • Page 345

    Power supply 7-29 ps5 00 ac power supply un it 7 removing the power supply 1. Locate a desk or table top that can support 50lb (23kg). If the surface can be damaged by sharp objects, place a protective sheet of cardboard or similar material over the top surface. 2. Place an anti-static sheet over a ...

  • Page 346: Troubleshooting

    7-30 coral ipx 500 installation manual ps5 00 ac power supply un it 7 0. Power supply failure generally results in the loss of one or more output voltages. However, protection circuitry in the power supply regulator may shut down a regulator due to a current overload caused by an external fault. The...

  • Page 347

    Power supply 7-31 ps5 00 ac power supply un it 7 ps500 ac fuses the ps500 ac employs two fuses: if the f1 fuse blows, the ps500 ac power green indicator and alarm red indicator do not illuminate. Do not replace the ac input fuse. It is not replaced in the field. Insert a different ps500 ac unit. If ...

  • Page 348

    7-32 coral ipx 500 installation manual ps5 00 ac power supply un it 7 determining the cause of the alarm indicator 1. Turn the ps500 ac power switch off (turn the switch downwards). 2. Disconnect the expansion cable(s) connected to the relevant cage. 3. Disconnect the battery pack connector from the...

  • Page 349: Specifications

    Power supply 7-33 ps5 00 ac power supply un it 7 0 ps500 ac (ac power supply) coral systems:.................................. Ipx 500m, 500x input:................................................ 100-240vac 47-63hz power rating: .................................. 115vac / 60hz / 6a (range: 98 to 12...

  • Page 350: Notes:

    7-34 coral ipx 500 installation manual ps5 00 ac power supply un it 7 notes:.

  • Page 351: 7.3

    Coral ipx 500 installation manual 7-35 ba tt ipx battery pack for ac powered system 7 7.3 battipx battery pack for ac powered system 0 the battipx unit is a battery pack that can be mounted either on a wall or on a rack. The battipx unit includes four 12v gel-cell batteries (7ah) and a case as a sin...

  • Page 352

    7-36 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 figure 7-9 view of battipx without cover on/off switch turns the battipx unit on and off, enabling maintenance f2 - ltu/csu fuse protects the batteries from a short circuit within the ltu/csu wires or within the lt...

  • Page 353

    Power supply 7-37 ba tt ipx battery pack for ac powered system 7 the battery pack is protected by a decorative cover that includes four panels: top, left, right, and front. See figure 7-10 . The front panel (near the top) includes two holes for inserting the assembly screws that fasten the decorativ...

  • Page 354: Circuit Description

    7-38 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 0 figure 7-11 on page 7-40 presents a block diagram of the battipx and the power circuitry that enables the ipx 500m and ipx 500x cages. The ps500 ac is normally fed by ac power input from which it produces the dc ...

  • Page 355

    Power supply 7-39 ba tt ipx battery pack for ac powered system 7 when the battery voltage drops below 44vdc, an alarm signal is generated, giving the operator the time needed to perform shutdown procedures. The power supply automatically restarts when the ac power returns. The battery pack is rechar...

  • Page 356

    7-40 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 alarm signals all the circuitry on the ps500 ac board is connected to an alarm circuit to provide the coral ipx 500 system with warnings when necessary. Low battery - when the battery voltage drops below 44vdc, an ...

  • Page 357

    Power supply 7-41 ba tt ipx battery pack for ac powered system 7 figure 7-12 battipx (issue-2) block diagram to ltu/csu f2 2a/250v s.B. Csu/ltu fuse f1 10a/250v s.B. Pabx/ps fuse 12v 12v 12v 12v red wire black wire on/off switch pabx/ps terminal block ltu/csu terminal block ac dc battery pack charge...

  • Page 358: External Connections

    7-42 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 0 the battery pack includes two dc output power terminal blocks that provide power to the coral ipx 500 and the ltu/csu. See figure 7-13 . Coral ipx 500 cage the right terminal block (labelled pabx/ps) supplies pow...

  • Page 359: Troubleshooting

    Power supply 7-43 ba tt ipx battery pack for ac powered system 7 0 battipx fuses the battery pack employs two fuses (see figure 7-9 ) that can be replaced in the field: f1 protects the battery against short circuit in the pabx/ps connection and is rated 10a/250v. If fuse f1 blows, the batteries will...

  • Page 360: Ltu/csu Connection

    7-44 coral ipx 500 installation manual b a t t ipx battery pack for ac powered system 7 0 to afford some protection and increase reliability to a pri/t1/e1 digital trunk facility, the network interface of the digital trunk card should not connect directly to the network. The ltu or csu is generally ...

  • Page 361

    Power supply 7-45 ba tt ipx battery pack for ac powered system 7 figure 7-14 battipx connection to the ltu/csu channel service unit (csu) or line termination unit (tlu) cat.No. 72446914056 rj-45 male plug coral ipx 500 priipx pstn public network da-15p d-type dc power wires ltu/csu terminal block ba...

  • Page 362

    7-46 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 connecting the battery pack to the ltu/csu unit the battipx is supplied with a dedicated 2 pole terminal block for connecting the 48vdc to the ltu/csu. It is the customer’s responsibility to fabricate the wire conn...

  • Page 363

    Power supply 7-47 ba tt ipx battery pack for ac powered system 7 figure 7-15 battery pack connection to ltu/csu x x x pabx/ps to ltu/csu to ltu/csu pabx/ps to ps500 ac pabx/ps to ps500 ac ltu/csu attach the wires to the ltu/csu terminal block. Step 2 x route the ltu/csu wires through holes 1 and 2. ...

  • Page 364: Installing The Battery Pack

    7-48 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 0 the supplied battery pack kit includes two brackets that can be mounted onto the rear side of the battery pack for wall mounting configurations or onto the front side of the of the battery pack for rack-mounted c...

  • Page 365: Operating The Battery Pack

    Power supply 7-49 ba tt ipx battery pack for ac powered system 7 0 1. Verify that the ps500 ac power switch is turned on (upwards) and that the green power indicator is lit, while the red alarm indicator is not lit. 2. Verify that the battery pack power switch is turned off (pressed down to the righ...

  • Page 366: Charging The Battery Pack

    7-50 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 0 1. After connecting the backup batteries and after the system initializes properly, allow 24 hours of constant operation to charge the batteries. 2. After charging, use a dvm to determine the output voltage of th...

  • Page 367: Testing The Battery Pack

    Power supply 7-51 ba tt ipx battery pack for ac powered system 7 to check the battery pack operation after charging, follow the procedure described below. 1. Verify that the pabx/ps connector is connected into the dc power connection of the ps500 ac power supply. See figure 7-8 on page 7-28 . 2. If ...

  • Page 368

    7-52 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 disconnecting the ac power cable from the ac power mains will not cause it to discontinue normal operation. The battery pack will will take up and provide the dc input. All output voltages will remain active. The o...

  • Page 369: 10 Maintenance

    Power supply 7-53 ba tt ipx battery pack for ac powered system 7 when the battery pack needs to be replaced the optimal voltage measured between the positive and the negative wires of the battery pack must be 48vdc. If the voltage measured is less than 42vdc, the battery is failed and the set must b...

  • Page 370

    7-54 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 measuring the battery pack voltage under load 1. Remove the ac power cable from the ps 500 ac. 2. Measure the output voltage. If the voltage measured by the dvm is lower than 42vdc, replace the batteries. See page ...

  • Page 371

    Power supply 7-55 ba tt ipx battery pack for ac powered system 7 removing the battery pack cover 1. Unfasten and remove the two screws that secure the battery pack cover to the battery pack. 2. Slide the cover off of the battery pack and remove it. Figure 7-16 battery pack cover removal top cover re...

  • Page 372

    7-56 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 replacing the batteries do not replace one battery at a time. Whenever a battery needs to be replaced, replace all of the other batteries as well. 1. Remove the battery pack cover. 2. Verify that the battery pack p...

  • Page 373

    Power supply 7-57 ba tt ipx battery pack for ac powered system 7 closing the battery pack cover 1. Turn on the battipx power switch. 2. Insert the three flaps on the edge of the top panel of the decorative panel into the mating slots on the battery pack frame. See figure 7-10 on page 7-37 . 3. Push ...

  • Page 374: 11 Specifications

    7-58 coral ipx 500 installation manual ba tt ipx battery pack for ac powered system 7 0 battery: four ul approved batteries with the following specifications: type.............................. Lead-acid nominal voltage .......... 4 x 12v = 48v nominal capacity ........ 7ah dimensions .................

  • Page 375: Chapter

    Coral cor coral ipx 500 installation manual chapter 8 common control cards 8.1 control cards ...................................................... 8-1 8.2 mcp-ipx card .....................................................8-5 8.3 imc8 card .........................................................8-2...

  • Page 377: 8.1

    Common control cards 8-1 cont ro l car d s 8 8.1 control cards 0 the common control portion of the coral ipx 500 system provides the control mechanism for establishing audio and data connections or calls between peripheral i/o ports in the system via the pcm bus. Common control is divided into the f...

  • Page 378

    8-2 coral ipx 500 installation manual cont ro l car d s 8 the dbx is an optional card that expands the database memory space which stores the system's configuration. The dbx is generally not required in coral ipx 500 systems. It is likely to be required in special applications. Or when the coralink ...

  • Page 379: Card Handling Procedures

    Common control cards 8-3 cont ro l car d s 8 0 the system cabinet is equipped with an esd strap at the top left, above the top card cage. This wrist strap should be worn while inserting, removing, or handling any card in the system. Each card is shipped inside an anti-static plastic bag. Cards shoul...

  • Page 380: Notes:

    8-4 coral ipx 500 installation manual cont ro l car d s 8 notes:.

  • Page 381: 8.2

    Common control cards 8-5 mc p-ipx car d main pr ocess o r unit 8 8.2 mcp-ipx card main processor unit 0 this section describes the features and functions of the mcp-ipx controller card. The mcp-ipx card is the control processor card for coral ipx 500 systems. The mcp-ipx card provides rs-232e progra...

  • Page 382

    8-6 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 figure 8-1 mcp-ipx card dip switches reset imc8 status display kb0 rs-232e m c p - i p x j1 dbx/cla connector j1 bus controller address decoder backup battery sau connector cpu 386ex.

  • Page 383

    Common control cards 8-7 mc p-ipx car d main pr ocess o r unit 8 memory management all system memory resides on the mcp-ipx card. Random access memory (ram) is located directly on the mcp-ipx card. The mcp-ipx also acts as a mother card to baby cla and dbx memory cards. The dbx contains 1mb of stati...

  • Page 384

    8-8 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 the mcp-ipx supervises the feature authorization using the sau (software authorization unit) lock device. The sau is a small, encapsulated device, which is plugged into a component side connector on the mcp-ipx. Figure 8...

  • Page 385

    Common control cards 8-9 mc p-ipx car d main pr ocess o r unit 8 figure 8-2 software authorization unit (sau) detail when starting up the coral system, ensure that there are no sau fault messages during startup or sau alarms (pi branch: root, 1, 1, 15-controls) due to any one of the following three ...

  • Page 386: Front Panel Features

    8-10 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 figure 8-3 illustrates the front panel of the mcp-ipx card. The front panel contains various elements. The following table is a listing of the various functions and what they are for. Table 8-1 mcp-ipx control card func...

  • Page 387

    Common control cards 8-11 mc p-ipx car d main pr ocess o r unit 8 figure 8-3 mcp-ipx front panel reset pushbutton imc8 imc8 release button 7-segment status display green led kb0 rs-232e serial programming port interface kb0 m c p - i p x option dip switches (always set to the right).

  • Page 388: Imc8 Memory Card

    8-12 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 the imc8 is an integrated memory card with a 8 mb flash memory capacity. It contains the generic software of the coral and is used to store the system database. See page 8-23, imc8 card for details. The imc8 is used by ...

  • Page 389: Kb0 Rs-232E Programming Port

    Common control cards 8-13 mc p-ipx car d main pr ocess o r unit 8 0 the serial interface of the kb0 programming port on the mcp-ipx conforms to the eia rs-232e specification. It is wired as a data terminal equipment (dte) device using a popular 9-pin, male, d type connector. The interface allows con...

  • Page 390: Dbx Memory Card Installation

    8-14 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 the dbx card is an expansion card of memory. It adds an additional 1 mb sram to the coral main control. The card is equipped with an extension connector on its top side allowing for another dbx or cla card to be connect...

  • Page 391: Cla Card Installation

    Common control cards 8-15 mc p-ipx car d main pr ocess o r unit 8 0 the cla card may be installed using the memory card interface connector j1 on the mcp-ipx card. The cla is installed as the “upper” card at the memory extension connector on the first dbx. See page 8-37, cla card for details. 7 cla ...

  • Page 392: McP-Ipx Card Installation

    8-16 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 the mcp-ipx card is installed in a reserved slot. 1. Remove power from the coral ipx 500 system by positioning the ps500 power supply power toggle switch to the off position (turned downwards). 2. Carefully remove the p...

  • Page 393

    Common control cards 8-17 mc p-ipx car d main pr ocess o r unit 8 0 locate a desk or table capable of supporting 50 pounds (23kg). If the top surface might be damaged by sharp objects, place a protective sheet of cardboard or similar material over the top surface. Next, place an anti-static sheet (t...

  • Page 394

    8-18 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 a new lithium battery can maintain power to the mcp-ipx memory circuitry and real-time clock for approximately 90 days. The battery is not recharged by the system power. Thus, if the battery has powered the memory and r...

  • Page 395

    Common control cards 8-19 mc p-ipx car d main pr ocess o r unit 8 figure 8-5 mcp-ipx memory interface card layout dbx/cla connector j1 bus controller kb0 address decoder remove before use database memory backup battery sau connector cpu 386ex dbx/cla mounting hole cla mounting holes option dip switc...

  • Page 396

    8-20 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 0 the mcp-ipx numeric status display indicates various operating and error states of the coral ipx 500 system, and can provide valuable information to assist in the maintenance of the system. Table 8-3 lists the various s...

  • Page 397

    Common control cards 8-21 mc p-ipx car d main pr ocess o r unit 8 should other symptoms of system malfunction also be present with an error indication, the error indications will assist maintenance personnel in determining the nature of the fault. Table 8-3 mcp-ipx status display codes status displa...

  • Page 398: 12 Specifications - McP-Ipx

    8-22 coral ipx 500 installation manual mc p-ipx car d main pr ocess o r unit 8 00 microprocessor : ..................... Intel™ 80386ex cpu clock rate :.................... 32 mhz memory addressing :............ 16 mb data bus structure :............... 16 bit; shared with dbx, cla, imc8 and msbipx ...

  • Page 399: 8.3

    Common control cards 8-23 im c8 car d fl a sh -e ras ab le so ft w a re m emo ry u n it 8 8.3 imc8 card flash-erasable software memory unit the imc8 flash memory card is a removable component of the coral ipx 500 common control section. Installed on the mcp-ipx, it incorporates 8 mb of erasable, pro...

  • Page 400

    8-24 coral ipx 500 installation manual im c8 car d fl a sh -e ras ab le so ft w a re m emo ry u n it 8 figure 8-7 imc8 flash memory card - right side imc8 provides an extremely reliable and non-volatile storage medium, yet allows field software update capability. Once programmed, the flash eprom mem...

  • Page 401: Imc8 Installation

    Common control cards 8-25 imc8 ca rd f la sh -e ra sa b le s o ft w a re m em o ry u n it 8 0 the imc8 does not occupy a card slot within the coral ipx 500 system cabinet. It is installed on the pcm-cia connector on the mcp-ipx card print side. The imc8 release button enables the removal of the imc8...

  • Page 402: Imc8 Removal

    8-26 coral ipx 500 installation manual imc8 ca rd f la sh -e ra sa b le s o ft w a re m em o ry u n it 8 the imc8 release button enables the removal of the imc8 card. When replacing an imc8 card with another card that contains upgraded software, the new card will not contain a database. It is theref...

  • Page 403: Specifications

    Common control cards 8-27 im c8 car d fl a sh -e ras ab le so ft w a re m emo ry u n it 8 0 storage capacity: ...................... 8,388,608 bytes (8mb) memory configuration: ........... 16 bits pcmcia: .................................... Standard compatible figure 8-8 imc8 card position on mcp-i...

  • Page 404: Notes:

    8-28 coral ipx 500 installation manual im c8 car d fl a sh -e ras ab le so ft w a re m emo ry u n it 8 notes:.

  • Page 405: 8.4

    Common control cards 8-29 dbx car d da taba se exp ansio n memory un it 8 8.4 dbx card database expansion memory unit 0 the dbx memory expansion card is a component of the coral ipx 500 common control section. The dbx incorporates 1 mb of static random access memory (sram), used to store the configu...

  • Page 406

    8-30 coral ipx 500 installation manual dbx car d da taba se exp ansio n memory un it 8 provides continuous power to the memory circuitry during the absence of system power. A battery monitor circuit signals the main processor when the remaining electrical power stored in the lithium backup battery h...

  • Page 407

    Common control cards 8-31 dbx car d da taba se exp ansio n memory un it 8 when is a dbx card required? A dbx card is required when: coral systems with a cla card installed for coralink the coral directory feature is used consult the program interface reference manual (chapter-4 size definition, rout...

  • Page 408: Dbx Installation

    8-32 coral ipx 500 installation manual dbx car d da taba se exp ansio n memory un it 8 0 the dbx is secured to the mcp-ipx or to the memory interface extension connector of another dbx card by a threaded nylon spacer. Preparing for installation 1. Locate a desk or table top that will support 50 lb (...

  • Page 409

    Common control cards 8-33 dbx car d da taba se exp ansio n memory un it 8 8. Carefully align the multi-pin connector on the bottom side of the dbx card with the memory interface extension connector. 9. Gently but firmly press the dbx connector into the extension connector until the dbx card rests on...

  • Page 410: Dbx Removal

    8-34 coral ipx 500 installation manual dbx car d da taba se exp ansio n memory un it 8 0 1. Repeat steps step 1 through step 4 on page 8-32, preparing for installation . 2. Remove the nylon machine screw that secures the dbx card to the standoff spacer on the mcp-ipx card. 3. Place thumbs on the mcp...

  • Page 411: Specifications - Dbx

    Common control cards 8-35 dbx car d da taba se exp ansio n memory un it 8 0 storage capacity: .................1,048,576 bytes (1.0mb) memory configuration: .....524,288 16 bits memory device: ...................128kb 8 bit sram battery : ...................................Lf1/2w, 2430, 2430b voltag...

  • Page 412: Notes:

    8-36 coral ipx 500 installation manual dbx car d da taba se exp ansio n memory un it 8 notes:.

  • Page 413: 8.5

    Common control cards 8-37 cla car d coralink adapter 8 8.5 cla card coralink adapter 0 the cla ( coralink adapter) appears in various configurations: cla 386 (10base-2 via coax) [this type is discontinued] cla 486 (10base-t via rj-45) f-cla 686 (10/100base-t via rj-45) with a compact flash memory ca...

  • Page 414

    8-38 coral ipx 500 installation manual cla car d coralink adapter 8 figure 8-10 cla 486 card figure 8-11 f-cla 686 card rst led co m 1 line 10base-t coralink cla note: the wire must be facing towards the outside away from the pcb, with the white dot visible pc104 bus co rem od ule 48 6 mi nim od ule...

  • Page 415

    Common control cards 8-39 cla car d coralink adapter 8 the dip switch located on the right side of the cla can be set to the following modes: all the switches “right” provides the mode for the normal working condition of the cla card. Switches 1 through 3 “left”, provides the debug mode. This mode i...

  • Page 416

    8-40 coral ipx 500 installation manual cla car d coralink adapter 8 the communication protocol implemented in the network is tcp/ip. The connection to the computer network is made with a rj-45 connector type in accordance with the 10/100base-t protocol and is located on the front panel of the cla ba...

  • Page 417: Cla Installation

    Common control cards 8-41 cla car d coralink adapter 8 0 this section details the coralink adapter hardware installation procedure. Coralink software installation is detailed in chapter 4 of this manual. The hardware installation procedure necessitates shutting off the coral ipx 500 input power, whi...

  • Page 418

    8-42 coral ipx 500 installation manual cla car d coralink adapter 8 5. If dbx card is installed, skip to step 7. Install three type a spacers (see figure 8-14 ) provided with the cla card into the three mounting holes on the mcp-ipx. See figure 8-5 . 6. Remove the three nylon screws threaded into th...

  • Page 419

    Common control cards 8-43 cla car d coralink adapter 8 figure 8-14 mcp-ipx spacers for cla and dbx nylon screw cla cla mcp-ipx mcp-ipx nylon screw nylon screw spacer type a spacer type a spacer type b spacer for cla spacers for cla and dbx.

  • Page 420: Cla Removal

    8-44 coral ipx 500 installation manual cla car d coralink adapter 8 0 1. Repeat steps 1 through 3 above. 2. Disconnect the rj-45 connector from the cla card via the top of the coral ipx 500 main cage. 3. Carefully remove the mcp-ipx card from its slot and lay it flat, over the anti-static material. ...

  • Page 421: Network Connections (Rj-45)

    Common control cards 8-45 cla car d coralink adapter 8 0 connection to the lan the front panel of the cla module contains a rj-45 adapter for connection to the ethernet computer network. The cla is designed to operate over ethernet lan with a connection of less than 100 meters to the local switch or...

  • Page 422

    8-46 coral ipx 500 installation manual cla car d coralink adapter 8 figure 8-15 cla (with rj-45) connection.

  • Page 423: Database Programming

    Common control cards 8-47 cla car d coralink adapter 8 0 the installation of a cla card to a coral ipx 500 system affects the system database. For further information, refer to chapter 27 in the program interface reference manual . In coral cti applications, coralink is connected to the ethernet bac...

  • Page 424

    8-48 coral ipx 500 installation manual cla car d coralink adapter 8 figure 8-16 coralink application telephony server any telephony server (e.G. Flexct server, callpath, ct connect, tsapi, up to 8 connections). Ivr server cti clients lan server computers with cti applications tcp/ip . . . Ethernet 1...

  • Page 425: Specifications - Cla

    Common control cards 8-49 cla car d coralink adapter 8 cla 486 application interface: ....................................... Complies with ecma 179, 180 and csta iii access protocol: ................................................. Itu x.217/x.227 (acse), x.219/x.229 (rose) network type: ............

  • Page 426: Notes:

    8-50 coral ipx 500 installation manual cla car d coralink adapter 8 notes:.

  • Page 427: Chapter

    Coral cor coral ipx 500 installation manual chapter 9 shared service ports 9.1 shared service circuitry...................................... 9-1 9.2 ipx 500m backplane ...........................................9-5 9.3 ipx 500x backplane ..........................................9-25 9.4 three-way ...

  • Page 429: 9.1

    Shared service ports 9-1 sha re d service cir cuit ry insta lla tio n 9 9.1 shared service circuitry installation 0 the shared service circuits provide functions such as dial and call progress detection, mf tone dialing reception, and multi-party conferencing. Shared service circuits reside on the p...

  • Page 430

    9-2 coral ipx 500 installation manual sha re d service cir cuit ry insta lla tio n 9 0 additional shared service cards may be installed in the optional coral ipx 800x expansion cage. The additional cards include, but are not limited to: 3 additional shared service cards in the optional ipx 800x cage...

  • Page 431

    Shared service ports 9-3 sha re d service cir cuit ry insta lla tio n 9 these cards are described in the coral service and peripheral cards installation manual . Shared service cards may be installed in any available peripheral card slot in the optional coral ipx 800x expansion unit. In the pi syste...

  • Page 432: Notes:

    9-4 coral ipx 500 installation manual sha re d service cir cuit ry insta lla tio n 9 notes:.

  • Page 433: 9.2

    Shared service ports 9-5 ipx 5 0 0m b a ckpl a ne main service boa rd in side th e ipx 5 0 0m ca g e 9 9.2 ipx 500m backplane main service board inside the ipx 500m cage 0 figure 9-1 on page 9-10 illustrates the msbipx card circuits layout. The msbipx card main shared service functions are described...

  • Page 434

    9-6 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 the intelligent backplane msbipx incorporates: a 384 timeslot matrix for switching calls a 512 timeslot matrix (384 for switching calls and 128 for shared service resources) an eight port...

  • Page 435

    Shared service ports 9-7 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 the maintenance and auxiliary functions include: modem for remote maintenance. See page 9-45, remote maintenance modem . Three rs-232e local maintenance terminals. See page 9-51, kb1, kb2, kb3: rs-2...

  • Page 436: Configuration Jumpers

    9-8 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 the ipx 500m backplane is equipped with jumpers (ju5 - ju14) that enable or disable various functions. The enabling or disabling is accomplished by jumper straps. Before installing the ...

  • Page 437: Indicators

    Shared service ports 9-9 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 the msbipx card is equipped with one led (ld1), located above the universal slot# 5 and 6 connectors (see figure 9-1 ). Before closing the front door, the led should be extinguished. 4 indicators in...

  • Page 438

    9-10 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 figure 9-1 msbipx card circuits layout and jumpers tones, dtmf, mfc prom hdc software prom u107 u118 8 7 6 5 4 3 2 1 mcp-ipx connector universal slots urc software prom 8drcf software ep...

  • Page 439: Auxiliary Connector

    Shared service ports 9-11 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 the auxiliary connector figure 9-2 , provides three rs-232 interfaces kb1-3, music, paging connection, and relay circuits. Table 9-1 provides the pinout connection for the auxiliary connection. Table...

  • Page 440

    9-12 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 figure 9-2 coral ipx 500m auxiliary connector location (top left view) auxiliary connector.

  • Page 441

    Shared service ports 9-13 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 figure 9-3 displays the coral ipx 500 architecture. The dual-bus architecture of the coral ipx 500 backplane incorporates a 512 timeslot matrix within the msbipx. This high speed, high capacity swi...

  • Page 442

    9-14 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 strengths that allow it to meet the requirements of high-demand applications. The dual-bus design has fault-tolerance and disaster avoidance built-into it along with an ability to handle...

  • Page 443

    Shared service ports 9-15 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 figure 9-1 illustrates the hdc prom (u107) location on the msbipx card. Figure 9-5 illustrates the four major circuit areas of the hdc circuitry in a block diagram. The hdc serves as a communicatio...

  • Page 444

    9-16 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 database to synchronize the pcm clock of the hdc with the digital trunk. In the absence of an external clock source, the hdc always reverts to an internal clock. The hdc contains phase-l...

  • Page 445

    Shared service ports 9-17 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 using time slots a call between two ports requires one transmit and one receive time slot on a single peripheral highway. Therefore, the hdc circuitry is capable of establishing a call between 64 por...

  • Page 446

    9-18 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 the msbipx contains circuitry that synchronize the coral ipx 500 peripheral clock to an external clock derived from a digital trunk interface cards such as the 30tipx, t1ipx, pri23ipx,...

  • Page 447: 8Drcf Eprom (U76)

    Shared service ports 9-19 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 features figure 9-1 illustrates the 8drcf eprom (u76) location on the msbipx card. The 8drcf software includes the following shared service functions: 9 8drcf eprom (u76) notation function d an 8 d...

  • Page 448

    9-20 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 database programming the 8drcf provides the features listed in table 9-2 . The 8drcf in a coral system has considerable impact on the system database. Use the pi to verify that each of t...

  • Page 449

    Shared service ports 9-21 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 table 9-2 8drcf features circuit purpose circuit no. Default name default dial no. Dtr eight dtmf signaling receivers 0-7 — — dtd eight dial and progress tone detectors 8-15 — — conf meet me bridge c...

  • Page 450

    9-22 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 table 9-3 8drcf pi (route: plis) shelf/slot/ckt type dial no. Name short : full 0 13 0 dtr — — — 0 13 1 dtr — — — 0 13 2 dtr — — — 0 13 3 dtr — — — 0 13 4 dtr — — — 0 13 5 dtr — — — 0 13...

  • Page 451: 10 Urc Prom (U161)

    Shared service ports 9-23 ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 0 the urc software is not installed in this version. 10 urc prom (u161).

  • Page 452: Notes:

    9-24 coral ipx 500 installation manual ipx 50 0m ba ckpla ne main service boar d i n side t h e ipx 50 0m cag e 9 notes:.

  • Page 453: 9.3

    Shared service ports 9-25 ipx 50 0x ba ckpla ne main service peri pheral boar d in si de th e ipx 50 0x cage 9 9.3 ipx 500x backplane main service peripheral board inside the ipx 500x cage 0 figure 9-6 illustrates the mspipx card circuits layout. The mspipx card does not provide shared service funct...

  • Page 454: Ipx 500X

    9-26 coral ipx 500 installation manual ipx 50 0x ba ckpla ne main service peri pheral boar d in si de th e ipx 50 0x cage 9 figure 9-6 mspipx card circuits layout and jumpers jumpers 8 7 6 5 4 3 2 1 9 10 universal slots power supply connector ju1 ju3 ju5 ju7 primary sync slot #4 secondary sync slot ...

  • Page 455

    Shared service ports 9-27 ipx 50 0x ba ckpla ne main service peri pheral boar d in si de th e ipx 50 0x cage 9 0 figure 9-3 on page 9-13 illustrates the coral ipx 500 architecture. The dual-bus architecture of the coral ipx 500 backplane incorporates a 384 timeslot matrix within the mspipx. This hig...

  • Page 456

    9-28 coral ipx 500 installation manual ipx 50 0x ba ckpla ne main service peri pheral boar d in si de th e ipx 50 0x cage 9 0 the mspipx contains circuitry designed to synchronize the coral ipx 500 peripheral clock to an external clock derived from a digital trunk interface cards such as the 30tipx,...

  • Page 457: 9.4

    Shared service ports 9-29 thr ee-w a y confer ence confer ence cir cuitry 9 9.4 three-way conference conference circuitry 0 the msbipx card provides up to six independent 3-way (conferences/consultation/broker service) conversation circuits. They can be used for: digital voice ports, such as skk, ip...

  • Page 458

    9-30 coral ipx 500 installation manual thr ee-w a y confer ence confer ence cir cuitry 9 card list (route: clis) card type must show 8drcf in the p_type field of shelf #0, slot #13 . Port list (route: plis,0) port type must show c3way in the type field of shelf #0, slot #13, ckt #17-22 . Refer to pr...

  • Page 459

    Shared service ports 9-31 thr ee-w a y confer ence confer ence cir cuitry 9 0 number of circuits: ...................6 4 specifications - 3-way conference.

  • Page 460: Notes:

    9-32 coral ipx 500 installation manual thr ee-w a y confer ence confer ence cir cuitry 9 notes:.

  • Page 461: 9.5

    Shared service ports 9-33 six-w a y mu lti-party co nfer ence meet me conf er en ce cir cuit ry 9 9.5 six-way multi-party conference meet me conference circuitry 0 the msbipx includes one six-way conference circuit. The meet me bridge manages one conference talk for up to six participants. Any combi...

  • Page 462: Database Programming

    9-34 coral ipx 500 installation manual six-w a y mu lti-party co nfer ence meet me conf er en ce cir cuit ry 9 0 the meet me bridge conference circuit (conf) requires the appropriate definitions in the database. Consult the program interface (pi) and database reference manual for instructions on the...

  • Page 463

    Shared service ports 9-35 six- w a y m u lti-party c o nfe rence meet me con fe re n ce ci rcui tr y 9 conf_lock feature timers (route: fe.T) this branch may be used to determine time intervals for multi-party conference call features. The related parameters are: conf_supv_recall grp_call_ring refer...

  • Page 464

    9-36 coral ipx 500 installation manual six-w a y mu lti-party co nfer ence meet me conf er en ce cir cuit ry 9 0 number of circuits: .................. 1 4 specifications - 6-way conference.

  • Page 465: 9.6

    Shared service ports 9-37 lo cally d efin ed t o ne pro m (u1 1 8 ) meet me confer ence cir cuitry 9 9.6 locally defined tone prom (u118) 0 the msbipx includes one tone prom (programmable read-only memory circuit). The hdc circuitry located on the msbipx generates the following tones: audio call pro...

  • Page 466: Country of Use

    9-38 coral ipx 500 installation manual lo cally d efin ed t o ne pro m (u1 1 8 ) meet me confer ence cir cuitry 9 when the coral ipx 500 system interfaces with a digital trunk interface to the north american public telephone network (the digital trunk provides public network service), the system mus...

  • Page 467: 9.7

    Shared service ports 9-39 dtmf receiver (dtr) 9 9.7 dtmf receiver (dtr) the msbipx includes the dtr circuits. The dtr provides eight circuits, which receive and decode dual tone multi-frequency (dtmf) dialing tones. The dtr is required to support telephone station apparatus or trunks that send dtmf ...

  • Page 468

    9-40 coral ipx 500 installation manual dtmf receiver (dtr) 9 how many dtmf receiver circuits (dtrs) are required? To provide adequate dtmf dialing quality of service in the system the number of dtmf receivers should match the anticipated traffic volume. The following table provides the amount of dtr...

  • Page 469: Database Programming

    Shared service ports 9-41 dtmf receiver (dtr) 9 the dtr requires the appropriate definitions in the database. Consult the program interface (pi) and database reference manual for instructions on the database programming required for the dtr. The following parameters must be set, to enable the dtr : ...

  • Page 470: Tip:

    9-42 coral ipx 500 installation manual dtmf receiver (dtr) 9 0 number of circuits: .................. 8 detection level: ......................... -28 to 0 dbm detection threshold: ................. -32 dbm min. Signal duration: ......................... 50 ms min. Interdigit time: ....................

  • Page 471: 9.8

    Shared service ports 9-43 dia l t o ne detector (dtd) 9 9.8 dial tone detector (dtd) 0 the msbipx includes the dtd circuits. The dtd provides eight identical circuits which detect and identify standard call progress tones such as dial tone, busy tone, reorder (fast busy) tone and ringback tone. The ...

  • Page 472: Database Programming

    9-44 coral ipx 500 installation manual dia l t o ne detector (dtd) 9 additional dtd cards may be installed in the optional coral ipx 800x expansion cage. The additional cards include: these cards are described in the coral service and peripheral cards installation manual . Shared service cards may b...

  • Page 473: 9.9

    Shared service ports 9-45 rem o te mai n ten ance modem 9 9.9 remote maintenance modem 0 the coral ipx 500 provides an auto-answer data modem via the msbipx. A full duplex, asynchronous, ascii modem, for remote programming the system database, diagnostics and system maintenance, and/or for displayin...

  • Page 474

    9-46 coral ipx 500 installation manual rem o te mai n ten ance modem 9 0 the msbipx card is equipped with jumper straps ju10 and ju11 (see figure 9-1 ) that enable and disable the modem. These jumpers, when removed, disable the on-board modem, without affecting the other programming interfaces. Thus...

  • Page 475

    Shared service ports 9-47 rem o te mai n ten ance modem 9 figure 9-7 modem - jumper configuration function rx modem - on rx modem - off ju10 2 1 3 2 1 3 function tx modem - on tx modem - off ju11 2 1 3 2 1 3 ju9 ju1 0 ju1 1 ju1 2 ju 13 ju1 4 ju 5 ju6 ju 7 ju 8 1 2 3 1 2 3 the modem may only be used ...

  • Page 476: Database Programming

    9-48 coral ipx 500 installation manual rem o te mai n ten ance modem 9 this function requires installation of an additional jumpers (ju10, ju11 pins 1 and 2 must be connected) on the msbipx card. Described on page 9-46 . The modem requires the appropriate definitions in the database. Consult the pro...

  • Page 477

    Shared service ports 9-49 re m o te ma in te n ance modem 9 connect state with any possible port in the system. For more information see chapter 19 in the program interface (pi) and database reference and database manual . Additional modem ports may be installed in the optional coral ipx 800x expans...

  • Page 478: Specifications - Modem

    9-50 coral ipx 500 installation manual rem o te mai n ten ance modem 9 0 modem operating modes: (v.92 itu-t) up to 56kbps client-to-server.......................................Datacomm: supports v.92 or k56flex modem compatibility ...........................Itu v.92, k56flex data communications via...

  • Page 479: 9.10

    Shared service ports 9-51 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 9.10 kb1, kb2, kb3: rs-232e data serial port the coral ipx 500 provides three eia rs-232e asynchronous, ascii serial data interfaces (kb1, kb2 and kb3) via the msbipx, for the following functions: system database programming...

  • Page 480: Ju12

    9-52 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 figure 9-8 kb1 (rs-232e) simplified interface diagram hdlc bus cts enable (1-2) on ju12 cts dsr rxd txd rts dtr sgnd 24 23 25 50 49 48 10 1 2 3 cts disable off (2-3) kb1 universal asynchronous receiver / transmi...

  • Page 481: Ju13

    Shared service ports 9-53 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 figure 9-9 kb2 (rs-232e) simplified interface diagram hdlc bus ju13 cts dsr rxd txd rts dtr sgnd 21 20 22 47 46 45 10 1 2 3 kb2 universal asynchronous receiver / transmitter (uart-2) auxiliary connector cts enable (1-2) on c...

  • Page 482: Ju14

    9-54 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 figure 9-10 kb3 (rs-232e) simplified interface diagram hdlc bus ju14 cts dsr rxd txd rts dtr sgnd 16 15 17 42 41 40 10 1 2 3 kb3 universal asynchronous receiver / transmitter (uart-3) auxiliary connector cts ena...

  • Page 483

    Shared service ports 9-55 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 0 the msbipx card is equipped with jumpers (ju12, ju13, ju14). Before installing the ps500 power supply, the jumpers on the msbipx card are set to their correct positions. See figure 9-1 and figure 9-11 . Jumpers ju12 (kb1)/...

  • Page 484

    9-56 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 figure 9-11 kb1,2,3 (rs-232e) jumper configuration for cts function cts - on cts - off kb1 ju12 2 1 3 2 1 3 kb2 ju13 2 1 3 2 1 3 kb3 ju14 2 1 3 2 1 3 ju 9 ju 10 ju 1 1 ju 12 ju 13 ju 14 ju 5 ju 6 ju 7 ju 8 1 2 3...

  • Page 485: Database Programming

    Shared service ports 9-57 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 0 the rs-232 serial port requires the appropriate definitions in the database. Consult the program interface (pi) and database reference manual for instructions on the database programming required for rs-232. Terminal setup...

  • Page 486

    9-58 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 0 the rs-232e data ports are wired as data terminal devices (dte). Figure 9-12 illustrates the connection to a typical data terminal. Table 9-1 on page 9-11 and table 9-4 below lists the function of each interfa...

  • Page 487

    Shared service ports 9-59 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 figure 9-12 kb1,2,3 (rs-232e) data port wiring to data terminal 1 2 3 transmit data - txd 50 47 42 receive data - data set ready - dsr 23 20 15 data terminal ready - dtr 48 45 40 request to send - rts 49 46 41 rxd 25 22 17 s...

  • Page 488

    9-60 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 0 additional rs-232 serial ports may be installed in the optional coral ipx 800x expansion cage. The additional cards include : these cards are described in the coral service and peripheral cards installation ma...

  • Page 489: Specifications - Rs-232E

    Shared service ports 9-61 kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 0 rs-232e data terminal port (kb1, kb2 and kb3): date rates................................................ 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200bps word length .......................................

  • Page 490: Notes:

    9-62 coral ipx 500 installation manual kb1, kb2 , k b 3 : rs-232 e d a ta serial po rt 9 notes:.

  • Page 491: 9.11

    Shared service ports 9-63 mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 9.11 music background and music-on-hold (m1/m2) the coral ipx 500 provides, via the msbipx, the following common system functions: two music inputs, one of which can be internal. Music-on-hold interface (two ports). Key tel...

  • Page 492

    9-64 coral ipx 500 installation manual mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 figure 9-13 music - simplified diagram figure 9-14 music m1 internal/external selection ju9 jumper setting 3 2 1 ju9 m2 m1 internal music source internal external music 2 external source pcm bus p c m bus music...

  • Page 493: Database Programming

    Shared service ports 9-65 m u sic backg rou n d a n d music-on-hold (m1 /m 2 ) 9 0 each coral ipx 500 main cage provides two music sources; m1 (external/ internal selectable) and m2 (external) . The music feature requires the appropriate definitions in the database. Consult the program interface (pi...

  • Page 494

    9-66 coral ipx 500 installation manual m u sic backg rou n d a n d music-on-hold (m1 /m 2 ) 9 information see chapter 27 - coralink in the program interface (pi) and database reference manual . Second music (m2) the m2 port is used as a second music source interface. Music sources (route: sysgen, 4)...

  • Page 495: External Connections

    Shared service ports 9-67 mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 0 figure 9-15 illustrates the connection of customer-supplied music sources. The first music source is passed to any port in a hold state and may also be selected as background music over the speaker of idle key telephone s...

  • Page 496

    9-68 coral ipx 500 installation manual mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 0 additional music ports may be installed in the optional coral ipx 800x expansion cage. The additional cards include: : these cards are described in the coral service and peripheral cards installation manual ....

  • Page 497: Specifications - Music

    Shared service ports 9-69 mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 0 m1/m2 (music-on-hold and background music): uses .......................................................... Music-on-hold (moh), background music termination ............................................. Capacitor-coupled...

  • Page 498: Notes:

    9-70 coral ipx 500 installation manual mu sic backgr oun d an d music-on-hold (m1/ m2 ) 9 notes:.

  • Page 499: 9.12

    Shared service ports 9-71 v oi ce pa gin g (pub lic add res) and rel ay-1 pu bli c ad dr ess 9 9.12 voice paging (public addres s ) and relay-1 public address the coral ipx 500 provides one external paging interface via the msbipx card (public address, one port). Station users can access an external...

  • Page 500

    9-72 coral ipx 500 installation manual v o ice pa gin g (pub lic add res) and rel a y-1 pu bli c ad dr ess 9 the external paging (p1) interface is electrically identical to the music interfaces. Audio signals from the system are passed through the audio coupling transformer to the interface. A direc...

  • Page 501: Database Programming

    Shared service ports 9-73 v o ice pa gin g (pub lic add res) and rel a y-1 pu bli c ad dr ess 9 0 each coral ipx 500 main cage provides one paging output: the external voice paging port operates by using both the relay circuit (rly1) and the p1 circuit. The paging feature requires the appropriate de...

  • Page 502: External Connections

    9-74 coral ipx 500 installation manual v o ice pa gin g (pub lic add res) and rel a y-1 pu bli c ad dr ess 9 0 the coral ipx 500 system provides a voice page interface for external paging and public address. The interface supplies a line-level (-10dbm or 50 to 100mv), 600 Ω , balanced audio output, ...

  • Page 503: Relay Electrical Limitations

    Shared service ports 9-75 v o ice pa gin g (pub lic add res) and rel a y-1 pu bli c ad dr ess 9 the relay contact closes continuously during access to the voice page interface. Although not always required, the relay contact is often utilized for "mac precedence" or "mute control" to mute background...

  • Page 504: Specifications - Paging

    9-76 coral ipx 500 installation manual v o ice pa gin g (pub lic add res) and rel a y-1 pu bli c ad dr ess 9 0 p1 (external paging): output termination ............................... Capacitor-coupled transformer, non-grounded output level ........................................... -15 dbm nominal...

  • Page 505: 9.13

    Shared service ports 9-77 una and relay-2 (u niversal n ight answering/ centra l bell) 9 9.13 una and relay-2 (universal night answering/central bell) 0 the coral ipx 500 provides, via the msbipx, relay contacts for central ringing bell interface. An incoming call may be automatically directed to a ...

  • Page 506: Database Programming

    9-78 coral ipx 500 installation manual una and relay-2 (u niversal n ight answering/ centra l bell) 9 0 the central bell (una) requires the appropriate definitions in the database. Consult the program interface (pi) and database reference manual for instructions on the database programming required ...

  • Page 507: External Connections

    Shared service ports 9-79 una and relay-2 (u niversal n ight answering/ centra l bell) 9 0 incoming trunk calls may be directed to activate a relay contact at certain times of the day (typically after normal business hours). The relay contact sounds a tone over a paging or public address system, or ...

  • Page 508: Relay Electrical Limitations

    9-80 coral ipx 500 installation manual una and relay-2 (u niversal n ight answering/ centra l bell) 9 0 the relay contacts have specific electrical limitations. For further detail, see page 9-87, relay contacts . These limitations must not be exceeded. In addition, the type of load the relay contact...

  • Page 509: 9.14

    Shared service ports 9-81 accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 9.14 accessory or alarm relay-3 major/minor alarm 0 the coral ipx 500 provides, via the msbipx, one relay contact for major/minor alarm or accessory interface. The coral ipx 500 system provides a multipurpose relay conta...

  • Page 510: Circuit Description

    9-82 coral ipx 500 installation manual accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 0 figure 9-22 is a simplified circuit diagram of the relay contacts. The relay provide form a (single pole, single throw and normally open) contacts for activating external circuitry and devices. Operation o...

  • Page 511: Database Programming

    Shared service ports 9-83 accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 0 the major and minor alarm or accessory interface feature requires the appropriate definitions in the database. Consult the program interface (pi) and database reference manual for instructions on the database programmi...

  • Page 512: External Connections

    9-84 coral ipx 500 installation manual accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 0 table 9-1 on page 9-11 lists the function of each interface pin, as they appear on the auxiliary i/o connector located on the left top main cage. See figure 9-2 on page 9-12 . Dial operated accessory to op...

  • Page 513: Relay Electrical Limitations

    Shared service ports 9-85 accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 0 the relay contacts have specific electrical limitations. See page 9-87, relay contacts . Do not exceed these limitations. In addition, the type of load the relay contact operates can have a great significance. Addition...

  • Page 514: Specifications - Relay-3

    9-86 coral ipx 500 installation manual accessory or ala rm rel a y-3 majo r/ mi nor ala rm 9 0 relay contacts (rly3): contact type ........................................... Isolated (dry) form a (spst-no) voltage limit........................................... 50 vdc maximum current limit ..........

  • Page 515: 9.15

    Shared service ports 9-87 r elay contacts rl y 1 , rl y2, rl y3 9 9.15 relay contacts rly1, rly2, rly3 0 the msbipx incorporates three relay contacts: external voice paging (page). See page 9-71, voice paging (public addres) and relay-1 . Universal night answer (una) central bell. See page 9-77, una...

  • Page 516

    9-88 coral ipx 500 installation manual r elay contacts rl y 1 , rl y2, rl y3 9 if the contact is to operate a relay or solenoid, use an alternating current (ac) operated device and an ac power source, if at all possible. Ac operated inductive loads produce much lower arc levels than direct current (...

  • Page 517: Specifications - Relays

    Shared service ports 9-89 r elay contacts rl y 1 , rl y2, rl y3 9 0 relay contacts (rly1, rly2, rly3): contact type ........................................... Isolated (dry) form a (spst-no) voltage limit........................................... 50 vdc max. Current limit ............................

  • Page 518: Notes:

    9-90 coral ipx 500 installation manual r elay contacts rl y 1 , rl y2, rl y3 9 notes:.

  • Page 519: Chapter

    Coral cor coral ipx 500 installation manual chapter 10 peripheral cards 10.1 peripheral card installation .............................10-1 10.2 peripheral card description ............................10-7 10.3 digital trunk synchronization ........................10-15.

  • Page 521: 10.1

    Peripheral cards 10-1 peri pheral car d in st all a ti on 10 10.1 peripheral card installation 0 the coral ipx 500 system divides peripheral interface functions among several different station and trunk card types. Each card contains 4, 8 or 16 similar circuits. Some analog trunk peripheral cards su...

  • Page 522: Card Handling Procedures

    10-2 coral ipx 500 installation manual peri pheral car d in st all a ti on 10 0 each of the coral ipx 500 cards contains circuitry sensitive to electrostatic discharge (esd). Failure to observe safe handling procedures for static-sensitive circuitry may result in permanent damage to a card. An anti-...

  • Page 523

    Peripheral cards 10-3 peri pheral car d in st all a ti on 10 0 card installation and initialization is done through automatic identification by the hardware application called "plug and play" (plug in and start working). All the technician has to do is to install the card into the required slot and ...

  • Page 524: Diagnostic Led Indication

    10-4 coral ipx 500 installation manual peri pheral car d in st all a ti on 10 0 each plug-in card is equipped with a red diagnostic indication led on the front side, near the top of the card. This led can assume one of three states of illumination: off, on, or flashing. The illumination state of the...

  • Page 525

    Peripheral cards 10-5 peri pheral car d in st all a ti on 10 led flashing the coral ipx 500 system continuously runs diagnostic routines to monitor the performance and integrity of its database and circuitry. When the circuitry on a particular card fails to perform as expected the system instructs t...

  • Page 526: Notes:

    10-6 coral ipx 500 installation manual peri pheral car d in st all a ti on 10 notes:.

  • Page 527: 10.2

    Peripheral cards 10-7 peripheral car d description xxxipx and xxxsl car d s 10 10.2 peripheral card description xxxipx and xxxsl cards 0 peripheral interface cards are described in the coral service and peripheral cards installation manual . Peripheral card slots in the ipx 500m main cage and in the...

  • Page 528

    10-8 coral ipx 500 installation manual peripheral car d description xxxipx and xxxsl car d s 10 table 10-2 coral ipx 500 peripheral card types card type card slot description 8sftipx, 16sftipx all 8 or 16 port, 2-wire sft (station flexset terminal) interface card. Each of the circuits support coral ...

  • Page 529

    Peripheral cards 10-9 peripheral car d description xxxipx and xxxsl car d s 10 4t-cipx, 8t-cipx all 4 or 8 port loop-start/ground-start trunk interface card. Includes 4 ports with power failure (pf) transfer. 4t-csl ( discontinued ), 8t-csl ( discontinued ) 1, 2, 3 ipx 500m 4t-cipx fj, 8t-cipx fj al...

  • Page 530

    10-10 coral ipx 500 installation manual peripheral car d description xxxipx and xxxsl car d s 10 pri-23ipx all 23 channel, pri (primary rate interface) digital trunk card. Isdn compatible digital interface, north america ansi standard (23b+d) at 1.544mbps ds1 rate. Pri-23sl ( discontinued ) 1, 2, 3 ...

  • Page 531

    Peripheral cards 10-11 peripheral car d description xxxipx and xxxsl car d s 10 0 xxxipx cards peripheral cards with the suffix “ipx” are special form-factor cards for use in the coral ipx 500 system. These cards include one guide pin and two black ejectors, as shown in figure 10-1 . The xxxipx card...

  • Page 532

    10-12 coral ipx 500 installation manual peripheral car d description xxxipx and xxxsl car d s 10 2. Remove the lower guide pin from the card. Figure 10-1 xxxipx peripheral card layout x x x i p x guide pin upper card ejector (black) with card name lower card ejector (black) front v iew right side v ...

  • Page 533

    Peripheral cards 10-13 peripheral car d description xxxipx and xxxsl car d s 10 figure 10-2 xxxsl and xxx-200 peripheral card layout x x x s l lower guide pin upper card ejector (red) with card name lower card ejector (red) fron t v iew right s ide v iew xxxsl upper guide pin.

  • Page 534: Notes:

    10-14 coral ipx 500 installation manual peripheral car d description xxxipx and xxxsl car d s 10 notes:.

  • Page 535: 10.3

    Peripheral cards 10-15 dig ital t run k synchr on izati on 10 10.3 digital trunk synchronization 0 the coral ipx 500 system is capable of operating in either master clock mode or slave clock mode. The selection between modes is made via the pi software. How the system derives the external clock sign...

  • Page 536

    10-16 coral ipx 500 installation manual dig ital t run k synchr on izati on 10 0 a total of six slots are factory set to accept digital trunk cards to operate in slave clock mode. Two slots are located in the coral ipx 500m main cage, two slots are located in the coral ipx 500x first expansion cage ...

  • Page 537

    Peripheral cards 10-17 dig ital t run k synchr on izati on 10 determines if the digital trunk card in the indicated position is properly synchronized with the network. If the system is functioning properly, the msbipx card locks onto the primary external clock source. If the primary digital trunk ca...

  • Page 538

    10-18 coral ipx 500 installation manual dig ital t run k synchr on izati on 10 figure 10-3 coral ipx 500 external clock sync card slots cor a l i p x 500x exp ansion cage 2n d s e c sync i/ o slo t pr m syn c i /o s l ot 1 6 2 7 3 8 4 9 5 10 cora l ip x 5 00x 1s t ex p a n s io n c a g e s e c s y n...

  • Page 539

    Peripheral cards 10-19 dig ital t run k synchr on izati on 10 0 optional synchronization cards in the ipx 500m main cage: pri-23ipx, pri-30ipx, udtipx(pri-23) t1 - t1ipx, udtipx(t1) e1 - 30tipx bri - 4tbripx, 8tbripx in the ipx 500x expansion cage: pri-23ipx, pri-30ipx, udtipx(pri-23) t1 - t1ipx, ud...

  • Page 540

    10-20 coral ipx 500 installation manual di g ital t ru n k synch ro n izat ion 10 bri lines for synchronization 1) bri lines used for synchronization must be defined in the pi (route: dtdb, 4) sync - yes. See pi manual chapter 26 - isdn for more information. 2) it is not recommended to use bri lines...

  • Page 541: Synchronization Instructions

    Peripheral cards 10-21 dig ital t run k synchr on izati on 10 0 1. See the selection of the digital trunk cards available at the coral site, given on page 10-19, choosing the best synchronization source above, to determine which cards will be used as the primary and secondary synchronization sources...

  • Page 542

    10-22 coral ipx 500 installation manual dig ital t run k synchr on izati on 10 figure 10-4 coral ipx 500m (main cage) jumper settings for synchronization figure 10-5 coral ipx 500x (expansion cage) jumper settings for synchronization slot 4 ju8 ju7 ju5 slot 5 primary secondary secondary primary n/a ...

  • Page 544

    International headquarters tadiran telecom ltd. 18 hasivim street p.O.Box 7607 petach tikva 49170 israel tel. +972-3-9262000, fax. +972-3-9262310 visit us at our website http://www.Tadirantele.Com email: coral@tadirantele.Com usa headquarters tadiran telecom, inc. 4 tri harbor court port washington,...