Tadiran Telecom TGW1E1-2G User Configuration Manual - Installation  Procedure

Manual is about: Trunk Gateway Series

Summary of TGW1E1-2G

  • Page 1

    1 tgwxe1-2g pri (isdn) trunk gateway series user configuration manual tgw1e1-2g tgw2e1-2g tgw4e1-2g document edition 2.1.

  • Page 2

    The information contained in this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreement protecting tadiran telecom (ttl) l.P.’s (herein referred to as the “manufacturer”) rights in the aforesaid inf...

  • Page 3: Record Of Changes

    3 record of changes edition no. Issue date brief description 2.1 oct-6-2015 added us alarms database requirements 2.0 aug-30-2015 1 st edition tgw1e1-2g, tgw2e1-2g, tgw4e1-2g based on nr document no.: mb5-e001-p, document version: 201504 document rev. 01 (apr, 2015 ) the tgw gateways support central...

  • Page 5: Table  Of  Contents

    I table of contents table of contents ............................................................................................................................................. I list of figures .........................................................................................................

  • Page 6

    Ii 5 tgw configuration .................................................................................................................................... 5-1 5.1 login .....................................................................................................................................

  • Page 7

    Iii 8 appendix: quick configuration procedure ............................................................................................ 8-1 8.1 gateway unit configuration .................................................................................................................................

  • Page 8: List  Of  Figures

    Iv list of figures figure 1-1 front panel ............................................................................................................................................. 1-3 figure 1-2 back panel .............................................................................................

  • Page 9

    V figure 7-1 isdn1 configuration interface ................................................................................................................ 7-1.

  • Page 10: List  Of  Tables

    Vi list of tables table 1-1 front panel .............................................................................................................................................. 1-3 table 1-2 indicators ...............................................................................................

  • Page 11: Overview

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 1-1 1 overview 1.1 product introduction the tgw1e1-2g, tgw2e1-2g, and tgw4e1-2g (herein referred to as the “tgwxe1-2g”) sip-isdn trunking gateway is one of voip gateway product series for aeonix uc&c . It uses sip and t1/...

  • Page 12

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 1-2 time between failures (mtbf), including features such as redundant power supply option and dual ethernet ports. In addition, the tgwxe1-2g uses a web-based graphical management interface to facilitate user configurat...

  • Page 13

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 1-3 1.3 equipment structure 1.3.1 front & back panel figure 1-1 front panel table 1-1 front panel item mark description ① rst pressing the rst button for less than 3 sec: no action will be taken. Pressing the rst button ...

  • Page 14

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 1-4 mark function status description flashing green system is operating normally alm alarm indicator green no alarms flashing red new alarms occurred red alarms exist eth interface state indicator green on the transmit s...

  • Page 15

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 1-5 1.3.2 con port the tgwxe1-2g provides one configuration interface (con) of rj45 interface for local management and debugging. Table 1-6 standard table for lead wire of pin at configuration port (con) pin number of rj...

  • Page 16

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 1-6 1.3.3 specifications table 1-8 specifications item description basic ethernet rj45, 4×10/100/1000m base-t, self-adaptive e1/t1interface 4, 120 simultaneous voip calls sd interface 1 con interface rj45 system memory 2...

  • Page 17: Installation  Preparation

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 2-7 2 installation preparation to avoid personal injury and tgw damage, please read this chapter carefully before installation. 2.1 installation precautions for your safety, please follow the precautions when tgwxe1-2g i...

  • Page 18

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 2-8 to ensure adequate ventilation to keep the gateway from overheating, there should be adequate clearance for the air intake and the air exhaust vents. Keep at least 6 cm clearance at the left and right side of the cha...

  • Page 19

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 2-9 2.3 opening inspection after the completion of installation preparation, you should open the box for inspection. Make sure the gateway and all in-box accessories match the description below. A tgwxe1-2g with basic co...

  • Page 21: Installation  Procedure

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 3-1 3 installation procedure 3.1 tools and meters screwdriver antistatic wrist strap ethernet and console port cables power cable terminals (a pc running terminal program can be used) universal electric meter multimeter 3...

  • Page 22

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 3-2 follow the steps to install the gateway: place the gateway on a shelf in the rack. Slide it to the proper position along the guide rails. Fix the rack-mount brackets to the rack posts with supplied phillips screws. M...

  • Page 23

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 3-3 3.3 installing cables 3.3.1 connecting console port a con should be provided with the tgwxe1-2g to check errors of the tgw. Connect the con with the computer’s rs232 serial ports, so local computers can interwork wit...

  • Page 24

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 3-4 3.3.3 connecting the t1/e1 cable tgwxe1-2g offers an rj45 jack as the t1/e1 connector for making isdn connection with the aeonix. Please identify the connector type and interface impedance of the other side equipment...

  • Page 25

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 3-5 3.3.5 connecting the power cord before connecting the power cord, make sure the ac power outlet has a protective earth contact and the earth contact of the ac power source is properly grounded. Please contact your ma...

  • Page 27

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 4-1 4 powering up the gateway 4.1 verification before power-up 4.1.1 checklist this is a review process of the installation work, including the chassis, wiring, connectors, ports, labels and site as described in the subse...

  • Page 29: Tgw  Configuration

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 5-1 5 tgw configuration 5.1 login double-click the icon to open ie browser, and enter the gateway ip address in the browser address bar (eg. 192.168.2.240). You can enter the login interface for gateway configuration by e...

  • Page 30

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-2 5.2 buttons used on gateway management interface submit buttons are located at the bottom of the configuration screens. It is used to submit configuration information. Users click the submit button after completion o...

  • Page 31

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-3 5.3 basic configuration 5.3.1 network configuration click the basic > network tab to open the network configuration interface. Figure 5-2 network configuration interface table 5-1 network configuration interface note...

  • Page 32

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-4 name description * netmask the subnet mask is used with an ip address. When the tgwxe1 gateway uses a static ip address of eth, this parameter must be entered. Gateway ip address lan gateway ip address where the tgwx...

  • Page 33

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-5 name description time zone select a time zone: (gmt-11:00) midway island (gmt-10:00) honolulu, hawaii (gmt-09:00) anchorage, alaska (gmt-08:00) tijuana (gmt-06:00) denver (gmt-06:00) mexico city (gmt-05:00) indianapo...

  • Page 34

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-6 5.3.2 system configuration click the basic > system tab to open the system configuration interface. Figure 5-3 system configuration interface table 5-2 system configuration parameters note: * indicates mandatory para...

  • Page 35

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-7 name description * dtmf off-time this parameter sets the off time (ms) of dtmf signals sent from the fxo port. The default is 100ms. Generally, the interval time should be set in the range of 80-150ms. For aeonix  e...

  • Page 36

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-8 5.3.3 sip configuration click the basic> sip tab to open the sip configuration interface. Figure 5-4 sip configuration interace table 5-4 sip configuration parameters note: * indicates mandatory parameters for aeonix...

  • Page 37

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-9 name description primary server heartbeat detect select the check box to enable and set the parameter options request period. The tgw detects the failure condition of the proxy server (primary server) by periodically...

  • Page 38

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-10 5.3.4 tdm configuration in case of full configurations, the tgwxe1-2g has one 4t1/e1 card, with four interfaces numbering tdm1 to tdm4 from left to right. It is recommended to set parameters corresponding to the int...

  • Page 39

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-11 name description digit (number) transformation number transformation on each t1/e1 link. Rule format for number transformation on a single t1/e1 link: operated number: operation rule set/operated number: operation r...

  • Page 40

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-12 requirements substitute the prefix 66 in the called numbers of calls to isdn1 with the prefix 71. For calls from isdn1, delete the first two digits of the calling numbers that start with the prefix 88. The tdm 1 rul...

  • Page 41

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-13 5.3.5 foip click the basic >foip tab to open the foip configuration interface. Figure 5-6 foip configuration interface table 5-8 foip configuration parameters note: * indicates mandatory parameters for aeonix. Name ...

  • Page 42

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-14 5.4 isdn in case of full configurations, the tgwxe1-2g has one 4t1/e1 card, with four interfaces numbering isdn1 to isdn4 from left to right. It is recommended to set parameters corresponding to the interface config...

  • Page 43

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-15 figure 5-8 isdn configuration interface 1 (including link data configuration) table 5-9 isdn configuration parameters name description name displays the name of the isdn interface. Enable enable an isdn interface. A...

  • Page 44

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-16 name description circuit hunting search mode of idle timeslot: forward, backward and cycle. Users can select from the drop-down box. Forward: in case of an incoming call, the tgwxe1-2g first checks whether timeslot ...

  • Page 45

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-17 name description isdn-b channel displays the indicator status of a specific isdn-b channel. If you click the channel in green, the indicator turns yellow and the call from ip to isdn on the t1/e1 line is prohibited....

  • Page 46

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-18 5.5 advanced configuration click the advanced tab to open the advance options interface. 5.5.1 routing table 5.5.2 application examples of routing table 5.5.3 ip table 5.5.4 digit map 5.5.5 system 5.5.6 security 5.5...

  • Page 47

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-19 5.5.1 routing table click the advanced > routing table tab to open the routing table configuration interface. * for aeonix us alarms  in order to disable the echo cancellation mechanism for port 2524, you should ad...

  • Page 48

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-20 the format of number transformation is: source number handle [parameter] or source number route destination [parameter] the format of number transformation is: source number replacement method for example: fxs 021 r...

  • Page 49

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-21 table 5-11 number transformations processing mode description and example keep keep number. The positive number after keep means to keep several digits at the beginning of the number; the negative number means to ke...

  • Page 50

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-22 processing mode description and example codec designate the use of codec, such as pcmu/20/16, where pcmu denotes g.711, /20 denotes rtp package interval of 20ms, and /16 denotes echo cancellation with 16ms window. P...

  • Page 51

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-23 5.5.2 application examples of routing table application requirements selecting an e1 line based on calls from the ip network. Replacing the calling party number section of an ip call with a shared number. Permitting...

  • Page 52

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-24 5.5.3 ip table click the advanced > ip table tab to open the ip table configuration interface. Figure 5-11 configuration interface for ip table this table is designed to ensure the safe use of gateways. Administrato...

  • Page 53

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-25 5.5.4 digit map in most situations, dialing rules need to be configured only for second dial on the tgwxe1-2g. Click the advanced > digitmap tab to open the digit map interface. Figure 5-12 configuration interface f...

  • Page 54

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-26 digit map description . Represents more than one digit between 0-9. The sign can match with number of any length. For example, the value 1. Can match with 11 or 123. ## end after receiving two-digit dialing “##”. “#...

  • Page 55

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-27 5.5.5 system click the advanced > system tab to open this interface. Figure 5-13 system advanced configuraiton interface table 5-14 advanced system configuration parameters note: * indicates mandatory parameters for...

  • Page 56

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-28 name description stun server this parameter appears when stun is selected for nat traversal. Set the ip or domain name of the stun server. No default value. If the stun server parameter is empty, the gateway will ad...

  • Page 57

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-29 5.5.6 security click the advanced > security tab to open this interface. Figure 5-14 security configuration interface table 5-15 security configuration parameters name description telnet & ssh service telnet select ...

  • Page 58

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-30 5.5.7 white list click the advanced > white list tab to open this interface. Figure 5-15 white list configuration interface procedures for configuring the whitelist are as follows: step1 click add. Step2 enter the a...

  • Page 59

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-31 5.5.8 media stream click the advanced > media stream tab to open this interface. Figure 5-16 media stream configuration interface table 5-16 media stream configuration parameters name description min. Rtp port the m...

  • Page 60

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-32 name description enable vad only applicable to g.723, gsm, ilbc. If selected, it will not send any voice packets during mute period. By default, this parameter is selected. Rtp destination address this parameter det...

  • Page 61

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-33 5.5.9 sip related configuration click the advanced > sip tab to open this interface. Figure 5-17 sip related configuration interface table 5-17 sip related configuration parameter name description sip related config...

  • Page 62

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-34 name description calling party number in call transfer under call forwarding, the calling party number sent can be set to originating number or forwarding number. The default is forwarding number. For example: the s...

  • Page 63

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-35 5.5.12 call progress tone plan click the advanced > tones tab to open this interface. Figure 5-18 tones configuration interface table 5-18 tones configuration parameters note: * indicates mandatory parameters for ae...

  • Page 64

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-36 5.6 status in case of full configurations, the tgwxe1-2g has one 4t1/e1 card, with four interfaces numbering isdn1 to isdn4 from left to right. Users can view the isdn calling state on the interface in usage. The ca...

  • Page 65

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-37 5.7 log management 5.7.1 system status critical runtime information of gateways can be obtained in this interface, including: the information about login interface (including ip address and permissions of the user) ...

  • Page 66

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-38 name description sip registration info shows registration status: not enabled - the registration server’s address is not entered yet. Latest response - the latest response message for the registration. 200 means reg...

  • Page 67

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-39 5.7.2 call message click the logs > call message tab to open this interface. Figure 5-21 call message interface.

  • Page 68

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-40 5.7.3 isdn status click the logs > isdn status tab to open this interface. Figure 5-22 isdn status interface table 5-21 isdn status parameters name description isdn group id the id of an isdn group. State three stat...

  • Page 69

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-41 name description linecode the line code, including b8zs, ami, jbzs, hdb3, zbtsi, b6zs, jbzs, etc. Linebuildout the line build-out, which is 120 or 75 (ohm). Clocktiming the clock source: local or through. Payload th...

  • Page 70

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-42 5.7.4 system startup click the logs > system startup tab to open this interface. The gateway boot up information is available on this page, including the hardware configuration. Figure 5-23 system startup interface.

  • Page 71

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-43 5.7.5 manage log click the logs > manage log tab to open this interface. Log files can be downloaded through this interface. Figure 5-24 manage log interface table 5-22 manage log parameters name description log lev...

  • Page 72

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-44 5.8 system tool 5.8.1 change password click tools to open this interface. Only administrators are entitled to change the password of login. To change the administrator password, enter a new password into the new pas...

  • Page 73

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-45 5.8.2 export data click the tools > export data tab to open this interface. You can download the configuration files from the gateway through this interface. The download procedure is similar to the download procedu...

  • Page 74

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-46 5.8.4 software upgrade click the tools > upgrade tab to open this interface. The software upgrade procedure is as follows: step1 obtain the upgrade files (tar.Gz file), and save the file onto a local computer. Step2...

  • Page 75

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-47 figure 5-30 upgrade interface step6 the following prompt is displayed during the upgrade. Figure 5-31 prompt of upgrade process the gateway upgrade takes a few minutes. Do not operate the gateway during this period....

  • Page 76

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-48 5.8.5 restore factory settings click tools > restore factory settings to restore the parameters of the gateway to factory settings. The factory settings are designed based on common applications, and therefore, no n...

  • Page 77

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 5-49 5.9 version information click info to view the gateway hardware and software version information. Figure 5-33 version information interface 5.10 logout click logout at the top right to exit the gateway management sy...

  • Page 79: Aeonix  Configuration

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 6-1 6 aeonix configuration it is necessary to define all pri trunks in aeonix before any calls can be routed through them. Pri trunks must be assigned to trunk groups to operate in the aeonix system. For detailed informat...

  • Page 80

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 6-2 6.2 basic configuration 1. Open the aeonix web admin. 2. Add a new trunk. A. In the navigation pane, select administration > trunks > add trunk, and then select the trunk type as sip trunk / gateway. B. Define the tr...

  • Page 81: Status  Verification

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 7-1 7 status verification 7.1 verification for each pri interface in the tadiran tgwxe1-2g gateway, you need to verify that it is registered and working ok in the status of the gateway. 1. Open the tgw web admin and login...

  • Page 83

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 8-1 8 appendix: quick configuration procedure this chapter describes the minimal settings instructions needed to use the tgwxe1-2g gateways with aeonix. 8.1 gateway unit configuration 8.1.1 basic configuration 1. Connect ...

  • Page 84

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 8-2 4. Click the basic > system tab. For detailed information, see system configuration on page 5-6. A) in the codec box, type the required codecs methods to be supported by the gateway. These codecs must be set due to n...

  • Page 85

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 8-3 formed with either numbers or characters, and is case-sensitive. Use table 5-5 table 5-5 as a worksheet to make a list of trunk user name/password. E) click submit to save changes. 6. Click the basic > tdm tab. For d...

  • Page 86

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 8-4 8.1.2 advanced configuration 1. Click the advanced > routing table tab . For detailed information, see routing table on page 5-19. A) in order to disable the echo cancellation mechanism for port 2524, you should add ...

  • Page 87

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 8-5 3. Click the advanced > tones tab to open the configuration interface . For detailed information, see call progress tone plan on page 5-35. A) from the country/region drop-down list, select the system location. Note:...

  • Page 88

    Tgwxe1-2g pri (isdn) trunk gateways series for aeonix user configuration manual 8-6 8.1.3 isdn configuration 1. Click the isdn > isdn1/isdn2/isdn3/isdn4 tabs. For detailed information, see isdn on page 5-14. Fill in the isdn1/2/3/4 pages, according to your pri service provider requirements. A) isdn1...

  • Page 89

    Tgwxe1-2g pri (isdn) trunk gateway series for aeonix user configuration manual 8-1 visit us at: www.Tadirantele.Com israel +972-3-9262000 usa +1- russia +7-495-7750855 china +86-10-58696418 india +91-11-41523168 / 23353822 678-506-7200