Talking Thermostats VIP 3000 Instruction Manual

Manual is about: Visually Impaired Programmable For 3 Stage Heat & 2 Stage Cool Conventional & Heat Pump Systems

Summary of VIP 3000

  • Page 1

    Vip3000 visually impaired programmable thermostat / customer information 1 large print customer instructions visually impaired programmable talking thermostat™ vip 3000 model for 3 stage heat & 2 stage cool conventional & heat pump systems ongratulations on acquiring the vip3000 “talking thermostat™...

  • Page 2

    Vip3000 visually impaired programmable thermostat / customer information 2 move down about an inch more until you feel another small round button. This is the report button. Press it and you’ll hear the indoor temperature, the system setting and the temperature setting. Now move your right thumb up ...

  • Page 3

    Vip3000 visually impaired programmable thermostat / customer information 3 weekend button is used to set up saturday and sunday programmable settings. The lower button is the weekday button. The weekday button is used to set up monday through friday programmable settings. Move your finger left about...

  • Page 4

    Vip3000 visually impaired programmable thermostat / customer information 4 • reset button: briefly press when you wish to exit program setup without accepting any changes. Your original program settings will be maintained. • day/time button: press briefly once to hear current day and time settings. ...

  • Page 5

    Vip3000 visually impaired programmable thermostat / customer information 5 external case buttons & display screen case buttons for easy access, routinely used buttons are located on the case, outside the panel door. They’re as follows: • help button: press this button to hear important system servic...

  • Page 6

    Vip3000 visually impaired programmable thermostat / customer information 6 • up button: briefly press and you’ll hear the temperature setting increase by one degree. • down button: briefly press and you’ll hear the temperature setting decrease by one degree. • backlight and version number button: br...

  • Page 7

    Vip3000 visually impaired programmable thermostat / customer information 7 “press the up or down key to set minutes. When finished press run” • press the up button once and you’ll hear “1”. Press again and you’ll hear “2”. Keep pressing until you’ve set the current minute time. When you have, press ...

  • Page 8

    Vip3000 visually impaired programmable thermostat / customer information 8 times and temperature settings. Using programmable operation saves you money by not excessively running your system when you’re not home or are sleeping. To set to programmable operation, flip down the front panel door and pr...

  • Page 9

    Vip3000 visually impaired programmable thermostat / customer information 9 sleep 10 pm 62º 82º . Changing programmable operation settings changes to your programmable settings can be made while your vip3000 is on the wall or detached from it. To set up the monday through friday program settings, ope...

  • Page 10

    Vip3000 visually impaired programmable thermostat / customer information 10 to adjust the day time period settings follow the same procedure, as you did for wake time. Evening and sleep then follow and are adjusted the same way. When all four time periods are programmed, you’ll hear, “program comple...

  • Page 11

    Vip3000 visually impaired programmable thermostat / customer information 11 programmable operation press the prog button until you hear “program is on” press the system button until you hear the system setting you want to run. Programmable operation works with all system settings, including heat, co...

  • Page 12

    Vip3000 visually impaired programmable thermostat / customer information 12 be careful when your system's running in auto change-over. Some users, to save money on energy, are used to significantly raising or lowering their temperature settings. However, in auto change-over, this can inadvertently c...

  • Page 13

    Vip3000 visually impaired programmable thermostat / customer information 13 volume control to adjust audio volume, first remove the front plate as described in t he previous, “low batteries” section. In the upper left corner of the front plate’s circuit board, you'll find a quarter of an inch square...

  • Page 14

    Vip3000 visually impaired programmable thermostat / customer information 14 delay time between stages, refer to “sd” in the table on page 15 of the “vt3000 user’s guide” or contact your service company. Second and third stage temperature differential the temperature differential for cycling on secon...

  • Page 15

    Vip3000 visually impaired programmable thermostat / customer information 15 note: for more in-depth, detailed technical information please consult the “vt3000 user’s guide” instruction booklet included in the thermostat product box. This thermostat was designed and manufactured by smartway solutions...