TATAREK RT-08G-BUF-SOLAR User Manual

Summary of RT-08G-BUF-SOLAR

  • Page 1

    Zakład elektroniczny tatarek jerzy tatarek user manual program version 3.0 ( ) 30.07.2012 1 fireplace lux (rt-08g-buf-solar) control unit of the heating system with the fireplace controlled by the air damper 16 rt08g_buf_solar/2012/v.3.0/ang the rt-08g-buf -solar control unit controls the heating sy...

  • Page 2

    2 15 2. Principle of operation the main function of the control unit is to keep temperature in the water jacket at the preset value. The task is realized by measuring temperature (t3) and controlling the cold air choke valve (pp) properly. Fireplace operation temperature is defined by the parameter ...

  • Page 3

    14 3 2.1 air damper operation the air damper regulates an air supply to the combustion chamber, which allows the temperature of the fireplace water jacket to be kept at the preset value. The task is realized by comparing the temperature of the water jacket(t3) and preset temperature (the parameter) ...

  • Page 4

    4 13 2.6 3. “control” output service of the control unit the control unit is equipped with the control relay whose contacts can be used e.G. To switch off another heat source when the fireplace works. The parameter defines the function of the relay more precisely. (see parameters level 3) control re...

  • Page 5

    5 załączony przekaźnik sterowanie wskazanie górnego czujnika cwu wskazanie dolnego czujnika cwu wskazanie czujnika kominka co * kom ? Cwu 80 o 73 o 68 o 12 1. Control unit status diode: alarm (red), standby (orange), operation (green), manual man (blinking green) 2. Graphic display 3. Button f1: swi...

  • Page 6

    6 11 alarm situation is accompanied by a broken sound alarm that can be turned off by pressing the confirm button (6) shows the current temperature of the fireplace and the level of air damper opening. In the emergency of exceeding the temperature the corresponding pumps start to run to cool off the...

  • Page 7

    7 automatic operation is activated by pressing the “on/off” button (3) the air damper is fully opened. In 2hrs the fireplace ought to heat itself and reach the preset temperature stabilized by air damper movements. From that moment the temperature fall to the preset temperature by more than 10 c (th...

  • Page 8

    8 9 screen of the clock the screen shows the current time and the number of the activated time zone. Time correction is possible after pressing the confirm button (6) and the minutes field begins blinking. The blinking value can be altered with the buttons “+” or “-” pressing the choose button (7) y...