TATAREK RT-08G-BUF User Manual - page 6

Manual is about: CONTROL UNIT OF THE HEATING SYSTEM WITH A FIREPLACE CONTROLLED BY A CHOKE VALVE

Summary of RT-08G-BUF

  • Page 1

    Zakład elektroniczny tatarek jerzy tatarek user manual program version 1.2 ( ) 31.10.2011 1 fireplace lux (rt-08g-buf) control unit of the heating system with a fireplace controlled by a choke valve 20 rt08g_buf/2011/v.1.2 ang titanium the rt-08g-buf control unit controls the heating system based on...

  • Page 2: Waw

    2 19 2. Principle of operation the main function of the control unit is to keep temperature in the water jacket at the preset value. The task is realized by measuring temperature (t3) and controlling the cold air choke valve (pp) properly. Fireplace operation temperature is defined by the parameter ...

  • Page 3: Fireplace

    18 3 ce conformity declaration ref. No. 58.Rt.01.2007/1/b we, zak Ł ad elektroniczny tatarek jerzy tatarek 75 swieradowska st. , 50-559 wroclaw declare under our sole responsibility that the product: regulator of heating system with solar collector model: rt-08, rt-08k, rt-08p, rt-08g, rt-08g-buf pn...

  • Page 4

    4 17 2.3 ch pump operation if the buffer temperature exceeds the preset value of 45 c (the parameter) the ch pump turns on. During loading the warm applicable water container waw, the ch pump runs cyclically if the waw mode is set to (limitation of the heat amount flowing into the ch system). The cy...

  • Page 5

    5 2.5 waw priority and the summer mode off - summer- on - priority- clock- special loading temp. Of waw special the waw loading pump turned off. Only the ch pump can run. Turning off the heating system in summer time (the ch pump doesn ’ t operate). Fireplace only works in the preparation function o...

  • Page 6

    6 15 3 service of the control unit there are elements on the control panel (fig. 2). In the turn-off state only the orange stanby state led (7) lights and the graphic display shows current temperature of the water jacket and current time. The turn-on of the control unit follows by pressing the butto...

  • Page 7

    7 14 3.1 time zones the control unit is equipped with the clock, which enables the automatic change of the control unit operation at different times of day. 24 hrs are divided into 5 time zones ( ) . Each zone has a start time from and an end time to. The same start and end time means the zone isn ’...

  • Page 8

    8 13 screen of the fireplace operation shows the current temperature of the fireplace and the level of choke valve opening. Temperature of the water jacket of the fireplace (t3) current time time zone operation mode of the fireplace preset temperature choke valve opening it ’ s a stable state, that ...

  • Page 9

    12 9 there are the following operation modes of the fireplace: automatic control locked - only manual control of the choke valve is available green status diode blinks. Setting the choke valve to the rest position ( the parameter).Green status diode doesn ’ t light. The choke valve is automatically ...

  • Page 10

    10 11 icon of the current mode selection of the mode from the list (+/-) screen of the clock screen of pumps operation for the basic operation configuration it ’ s a stable state, that is, in order to change it you need to press the choose button (7) enables changing the operation mode of the firepl...