µ-Dimension D3204 User Manual

Manual is about: Multizone Controller / Dimmer

Summary of D3204

  • Page 2: Table of Contents

    Table of contents features .................................................................................... 1 introduction ........................................................................... 2 description .............................................................................. 3 sp...

  • Page 3: Features

    Features • allows control of 4 local loads or additional loads with auxiliary device per multizone controller (incandescent, tungsten, magnetic low-voltage, advance transformer mark 10™ powerline fluorescent, neon, cold cathode and non- dimming) • auto off mode • remote zone control capability of up...

  • Page 4: Introduction

    Introduction the leviton multizone zone controller/dimmer, cat. No. D3204, provides advanced, multi-point scene control for commercial and high-end residential lighting applications. The d3204 is a user-friendly, self-contained unit that can be used to control—at one time from the front panel—up to ...

  • Page 5: Description

    Description the d3204 can function in two ways: one, as a self-contained dimmer for loads directly attached to it and two, as a control unit for other remote devices (which it can also power) attached to the leviton control network (lcnet) communication bus. The multizone controller is designed to b...

  • Page 6: Specifications

    Specifications electrical d3204-1 d3204-2 input: 120vac, +/-10%, 50-60hz 230vac, +/-10%, 50-60hz isolated output: 24vdc @150ma 24vdc @150ma power output: 1920w/va total 2400w/va total 1000w/va max. Per zone 800w/va max. Per zone 1200w/va max. Per side minimum load: 15w 15w surge protection: surge su...

  • Page 7: Quick Reference Guide

    Quick reference guide quick reference guide use this section for a quick reference for an overview of the operational features of the d3204 multizone controller. For customizing features, please refer to the programming/operation section of the manual. Call scene: used to choose which of the 32 prog...

  • Page 8: Page To Other Controllers:

    Page to other controllers: if using multiple multizone controllers, use this feature to access all multizone controllers or auxiliary devices addressed on the network. You can then modify or adjust lighting levels previously programmed. • press the page zones button to access the desired remote pane...

  • Page 9: Installation Instructions

    Installation instructions warning: to be installed and/or used in accordance with appropriate electrical codes and regulations. Warning: if you are not sure about any part of these instructions, consult a qualified electrician. Warning: do not connect line voltage wires to low-voltage terminals. War...

  • Page 10

    3. Remove front door frame assembly by gently lifting the bottom edge of the frame until it snaps off (refer to figure 1). Swing the bottom edge away until the upper section is released. 4. Mount 4-gang, 2-1/2" (6.4 cm) wall box with a 4-gang raised cover in wall at desired location. 5. Line voltage...

  • Page 11

    7. Carefully position all wires to provide room in wall box for multizone controller. Mount controller to raised cover using the screws provided (refer to figure 1). 8. Restore power at circuit breaker or fuse. 9. Check for power to the multizonecontroller by verifying that the green lcd on the fron...

  • Page 12: Figure 1

    4 gang box (4-1/2" wide x 2-1/2" deep) 4 gang raised cover (1/2" or 3/4" depth) raised cover mounting screw (4 places) dimensions multizone controller / dimmer front door cover overlay contrast adjustment (under overlay) installation instructions figure 1 multizone controller mounting 10

  • Page 13: Figure 2

    Installation instructions figure 2 multizone controller wiring diagram 1 11 dimensions multizone controller / dimmer l l l l neutral line ground distribution panel load 1 green lcnet blue/white blue green/white load 3 load 2 load 4 to d3200 components.

  • Page 14: Figure 3

    Low-voltage wires (plug-in connector) loads 1, 3 loads 2, 4 ground line neutral jumper lcnet termination can-l insulation electrical tape shrink tubing 3m fp-301-1 panduit hsttp00-q panduit tv105-1.0l 4 gang box (4-1/2" wide x 2-1/2" deep) raco part #943 steel city part #h4bd3/4-1 4 gang raised cove...

  • Page 15: Figure 4

    1) function/previous field button (programming) / shortcut button (change scene bank from main screen) (pgs. 14 and 17). 2) 2 line x 16 character display (lcd). 3) function/change option button (programming) (pgs. 14 and 17). 4) function/next field button (programming) / shortcut button (change scen...

  • Page 16: Programming

    Programming control buttons (refer to figure 4): with the cover closed, you can access the scene programming/recall, max, and off buttons. With the cover open, you can access the lcd display, the wizard/menus, select/next, cancel/previous, page zones, dim scene, dim/bright, zone info, and function/s...

  • Page 17

    Things to know for basic and more advanced applications: basic application - the d3204 multizone controller can be installed solely as a dimmer to control up to 4 loads. There are programming and operating procedures that will not be applicable for this type of configuration. For ease of use, the ba...

  • Page 18: Figure 6

    D320x panel 1a d320x panel 2a d320x panel 2b d320x panel 1b group 1 all 4 panels operate together group 2 - panels 1a and 2a operate together group 3 - panels 1b and 2b operate together d320x panel 1a d320x panel 2a d320x panel 2b d320x panel 1b group 2 group 3 all rooms and panels work independentl...

  • Page 19: To Program and Operate:

    To program and operate: pressing the wizards button (refer to figure 4) on the front panel of the multizonecontroller will help run through the setup and programming necessary to set desired scene lighting levels and timed events. Note: additional dimensions/lcnet compatible devices may have program...

  • Page 20: Panels –

    5. Press the up or down button to select ir code (default or learning). This default setting will let the unit work with the ne210 hand-held remote control or choose the learning ir which will activate the ir menu and allows you to program the unit to work with any standard remote control. Press sel...

  • Page 21: Zones –

    Panels are to be accessed from this panel using the page zones button. Press the select/next button to save entry and proceed. Note: if only one panel is installed, but programming of additional panels has been selected and included, the exclude default option will set automatically. Note: to contro...

  • Page 22: Aux Devices –

    Note: two channels cannot be mapped to the same channel number. You must first change the channel to an “x”, which is a place holder (i.E., to change 1 to 4, first change the 4 to an “x”, than change the 1 to a 4. You may now change the 4 to a 1). 23. Press the up or down button to select the desire...

  • Page 23: Info –

    Info – displays version of software, measures zero cross circuitry in microseconds, and temperature of sides of device. 29. Press the up or down button to select the info screen. Press the select/next button to save entry and proceed. 30. The software version will be displayed. Press the select/next...

  • Page 24: Scene Wizard –

    Scene wizard – the scene wizard allows for the programming and operation of up to 32 lighting scenes. Naming of device and lighting scenes gives user-friendly control of lighting loads. Proceed as follows: call scene – used to choose which of the 32 programmed scenes are to be called or activated. Y...

  • Page 25: Set Scene Bank –

    2. Press the up or down button to select the program scene screen. 3. Press the select/next button to access the program scene screen. 4. Press the up or down button to select the desired scene (1-32). Press the select/next button to save entry and proceed. 5. Press the up or down and left or right ...

  • Page 26: Set Scene Group –

    Set scene group – scene calls made from the multizone controller (menu or scene buttons 1-8) are made for the group chosen here. Proceed as follows: 1. Press the wizards button and then the up or down button (if necessary) to select the scene wizard. Press the select/next button to access the scene ...

  • Page 27: Exclude Zones –

    Exclude zones – used to remove a particular zone or zones from executing in a programmed scene. Proceed as follows: 1. Press the wizards button and then the up or down button (if necessary) to select the scene wizard. Press the select/next button to access the scene wizard. 2. Press the up or down b...

  • Page 28: Lock/unlock –

    Lock/unlock – used to program the locking or unlocking of individual zones. Locked zones will stay at set level unless unlocked. Proceed as follows: 6. Press the select/next button to access the zone wizard. 7. Press the up or down buttons to select the lock/ unlock screen. 8. Press the select/next ...

  • Page 29

    3b.To modify an existing timer: press the select/ next button to access the programmed timer screen. Press the down button to scroll through the existing timers. Press the select/next button to select the desired timer to modify. Proceed as follows: 4. Press the up or down and left or right buttons ...

  • Page 30: Holiday

    8. Press the up or down buttons to select the timer status (delete, enable, disable).Press the select/next button to save entry and proceed. 9. Repeat procedure for setting up additional timers. 10. Press the select/next button to return the timer wizard screen. Note: for auto off applications, a “s...

  • Page 31: Location Setup –

    Programming and operation location setup – the multizone controller will calculate the dawn/dusk times based on the latitude/longitude selected. 20. Press the select/next button to access the timer wizard. 21. Press the up or down buttons to select the location setup screen. 22. Press the select/nex...

  • Page 32: Auto Off –

    Programming and operation 33. Press the up or down buttons to select the next time event screen. 34. Press the select/next button to view the next time event menu. 35. Press the select/next button to save entry and proceed. Auto off – auto off is an energy savings feature where the lights will autom...

  • Page 33: Ir Wizard –

    Programming and operation ir wizard – the ir wizard allows for the programming and remote control of up to 32 lighting scenes, as well as max, off and group dim/ bright using any standard ir remote. Note: learning ir option must be programmed in setup wizard in order to access this ir wizard. Note: ...

  • Page 34

    Programming and operation 12. Press the select/next button to remove the selected action. Press the select/next button to save entry and proceed. 13. Repeat procedure for removal of additional commands. 14. Press the wizards button to return the main screen. Code removed 32.

  • Page 35: High Level Menu Tree

    Menu tree high level menu tree note: this sequence shows the order in which each menu will appear when scrolling through the menus using the down function button. 33 use , v or sel v use , v or sel v use , v or sel 1> basic v use , v or sel 2> p anels v use , v or sel 3> zones v use , v or sel 4> a ...

  • Page 36: Testing And Troubleshooting

    Troubleshooting testing and troubleshooting every d3204 unit local operations should be separately tested. That means checking that power, dimming control, scene control, and if applicable, the infrared receiver is working properly. You can either test a single function one controller at a time or y...

  • Page 37: Scene Control:

    Troubleshooting • make sure the lamps are not burned out. If any are, replace them . • refer to wiring diagrams for correct wiring. • if the lights remain at full brightness no matter what you push there must be a short. • before you replace the d3204 with a new one, make sure that the loads you pla...

  • Page 38: Scene Control:

    Testing d3204’s networked together do these tests only if you have multiple d3204’s working together via lcnet wiring. Note: no two devices can have the same panel number on the same lcnet. Scene control: you should perform this test as long as you require all controllers to have the ability to work...

  • Page 39

    State/city lat long alabama alexander city 33° n 86° w anniston ap 34° n 86° w auburn 33° n 85° w birmingham ap 34° n 87° w decatur 35° n 87° w dothan ap 31° n 85° w florence ap 35° n 88° w gadsden 34° n 86° w huntsville ap 35° n 87° w mobile ap 31° n 88° w mobile co 31° n 88° w montgomery ap 32° n ...

  • Page 40

    State/city lat long grand junction ap (s) 39° n 109° w greeley 40° n 105° w lajunta ap 38° n 103° w leadville 39° n 106° w pueblo ap 38° n 104° w sterling 48° n 103° w trinidad 37° n 104° w connecticut bridgeport ap 41° n 73° w hartford, brainard field 42° n 73° w new haven ap 41° n 74° w new london...

  • Page 41

    State/city lat long indiana anderson 40° n 86° w bedford 39° n 86° w bloomington 39° n 87° w columbus, bakalar afb 39° n 86° w crawfordsville 40° n 87° w evansville ap 38° n 88° w fort wayne ap 41° n 85° w goshen ap 42° n 86° w hobart 42° n 87° w huntington 41° n 85° w indianapolis ap 40° n 86° w je...

  • Page 42

    State/city lat loing michigan adrian 42° n 84° w alpena ap 45° n 83° w battle creek ap 42° n 85° w benton harbor ap 42° n 86° w detroit 42° n 83° w escanaba 46° n 87° w flint ap 43° n 84° w grand rapids ap 43° n 86° w holland 43° n 86° w jackson ap 42° n 84° w kalamazoo 42° n 86° w lansing ap 43° n ...

  • Page 43

    State/city lat long new hampshire berlin 44° n 71° w claremont 43° n 72° w concord ap 43° n 71° w keene 43° n 72° w laconia 43° n 71° w manchester, grenier afb 43° n 71° w portsmouth, pease afb 43° n 71° w new jersey atlantic city co 39° n 74° w long branch 40° n 74° w newark ap 41° n 74° w new brun...

  • Page 44

    State/city lat long lima 41° n 84° w mansfield ap 41° n 83° w marion 41° n 83° w middletown 40° n 84° w newark 40° n 82° w norwalk 41° n 83° w portsmouth 39° n 83° w sandusky co 41° n 83° w springfield 40° n 84° w steubenville 40° n 81° w toledo ap 42° n 84° w warren 41° n 81° w wooster 41° n 82° w ...

  • Page 45

    State/city lat long texas abilene ap 32° n 100° w alice ap 28° n 98° w amarillo ap 35° n 101° w austin ap 30° n 98° w bay city 29° n 96° w beaumont 30° n 94° w beeville 28° n 98° w big spring ap (s) 32° n 101° w brownsville ap (s) 26° n 97° w brownwood 32° n 99° w bryan ap 31° n 97° w corpus christi...

  • Page 46

    State/city lat long madison ap (s) 43° n 89° w manitowoc 44° n 87° w marinette 45° n 88° w milwaukee ap 43° n 88° w racine 43° n 88° w sheboygan 44° n 88° w stevens point 44° n 90° w waukesha 43° n 88° w wausau ap 45° n 90° w wyoming casper ap 43° n 106° w cheyenne 41° n 105° w cody ap 45° n 109° w ...

  • Page 47

    Notes.

  • Page 48: 1-800-824-3005 (U.S.A. Only)

    For technical assistance call: 1-800-824-3005 (u.S.A. Only) www.Leviton.Com/3200 limited 2 year warranty and exclusions leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by leviton is free of defects in materials and ...