WarmFlo HE-A-**-21 Series Installation & Operating Instructions Manual

Summary of HE-A-**-21 Series

  • Page 1

    02/04/2014 ni804 warmflo ® electric furnace installation & operating instructions he-a-**-21 series all he-a-**-21 electric furnaces must use one of two chip codes based on applications  an ahs chip code: forced air space heating applications wfmu chip code: make-up air applications. If you have a ...

  • Page 2: Table of Contents

    02/04/2014 ni804 table of contents configurator 1 inlet cabinets 2 general comments 3 application 4 installation requirements 6 mechanical installation 7 electrical installation 9 setup or programming 11 operation indicators 12 handheld analyzer/laptop software 13 troubleshooting 13 replacement part...

  • Page 3

    02/04/2014 1 ni804 configurator he-t-kw-cw type cabinet width h, a, e, n 21 = 21” (see below) 24 = 24”* kw size 10 = 9.6 kw 15 = 14.4 kw 20 = 19.2 kw* 25 = 24 kw* 30 = 28.8 kw* type all models – ecm™ blower motor, setup selection of four cooling sizes, 50% continuous air (fan – on setting). High eff...

  • Page 4

    02/04/2014 2 ni804 inlet cabinets factory optional cabinets can be configured with this electric furnace. Typically these are designed for upflow applications; however, the heat pump coil cabinet could be used in other positions. Side entry, filter cabinet return air can be ducted into either side, ...

  • Page 5

    02/04/2014 3 ni804 general comments upflow/downflow/horizontal the arrangement of refrigerant coil, hydronics coil, and built-in electric elements need to follow specific air direction or airflow rules, but the orientation of this electric furnace is not critical. For upflow and horizontal standard ...

  • Page 6

    02/04/2014 4 ni804 notice: when changing any setup jumpers, power down and up. Ecm™ motor needs 240v power and control power removed to reset and reread specific control lines. Open cb number 1 for 10 seconds. Operation instructions the “operation indicators” section contains information relating to...

  • Page 7

    02/04/2014 5 ni804 specification chart model number he-a-10-21 he-a-15-21 he-a-20-21 cabinet width 21” 21” 21” kw rating 10 15 20 btu/h 34000 51000 68000 voltage/phase 240/1 240/1 240/1 circuit breaker 60 1-60, 1-30 2-60 amps per cb 42 42, 21 42, 42 source feed 1 2 2 elements 4 6 8 relays 2 4 6 heat...

  • Page 8

    02/04/2014 6 ni804 installation requirements 1. All installation work must be performed by trained, qualified contractors or technicians. Electro industries, inc., sponsors installation and service schools to assist the installer. Visit our web site at electromn.Com for upcoming service schools. War...

  • Page 9

    02/04/2014 7 ni804 mechanical installation clearances and accessibility zero clearance is allowed on all sides for combustible materials. However, 36” should be allowed at the front for operation, maintenance, and service. To reduce the risk of rusting and appearance, do not install the unit directl...

  • Page 10

    02/04/2014 8 ni804 whether this unit is sitting on or attached to an inlet cabinet, field designed inlet cabinet, or horizontal supports; verify proper support and mechanical strength is provided within the system installation. Rubber isolation pads should be used where possible to reduce sound and ...

  • Page 11

    02/04/2014 9 ni804 electrical installation warning to avoid the risk of electric shock or death, wiring to the unit must be properly grounded. Failure to properly ground the unit can result in a hazard leading to personal injury or death. Line voltage the nameplate and/or installation and operating ...

  • Page 12

    02/04/2014 10 ni804 the sensor has polarity, is sensitive to wrong voltage, must be protected from static voltage, etc. Do not cross connect or inadvertently short out sensor wires with power on. Permanent destruct damage may result. Electric furnace control – inside view, right board there are seve...

  • Page 13

    02/04/2014 11 ni804 setup or programming it is extremely important the installer properly sets the peg jumpers for all of the following requirements. Warmflo controller – inside view, left board program control chip – ahs chip code this unit is provided with a control chip (version 2.36 or higher) w...

  • Page 14

    02/04/2014 12 ni804 operation indicators warmflo controller – inside view, left board monitor led’s on front green led illuminated when warmflo ii is receiving 24v power. Under all normal operating modes, this should be solid green.  as a secondary function this green led provides status of the two...

  • Page 15

    02/04/2014 13 ni804 additional information warmflo elements mechanical hi-limit for this unit there is no led’s representing mechanical, automatic reset, hi-limit. Ecm™ blower motor the “setup or programming” section outlined the peg jumper programming for selecting blower motor speed according to t...

  • Page 16

    02/04/2014 14 ni804 turn off the 24-volt source power (probably furnace or electric furnace circuit breaker), when the green led goes out, count to 10, and re-energize power supply. 2. The terminal blocks for control wire hook-up are designed for a wire insertion and screw clamp down. If there is no...

  • Page 17

    02/04/2014 15 ni804 replacement parts @wfs55612 sensor st filter 5 ft. @wfs255612 sensor 25 ft. Filter @wfcoe5615 pcb wf2 pic 74 dual heat @heibg6707 pcb electric furnace ecm™ motor h/c and hp stat @wfpdc5632 pcb power sup ac to dc 5850 motor ½ hp ecm™ ge 5541 transformer 120/240:24 40va 4038 triac ...

  • Page 26: Electro Industries, Inc.

    Page 1 of 2 xx017 electro industries, inc. Limited product warranty effective february 5, 2009 electro industries, inc. Warrants to the original owner, at the original installation site, for a period of two (2) years from date of installation, that the product and product parts manufactured by elect...

  • Page 27

    Page 2 of 2 xx017 these warranties do not cover: 1. Costs for labor for removal and reinstallation of an alleged defective product or product parts, transportation to electro industries, and any other materials necessary to perform the exchange, except as stated in this warranty. Replacement materia...