Water Right IMP-1044 Installation Instructions And Owner's Manual

Summary of IMP-1044

  • Page 1

    Impression plus series ® metered water softeners for models: • imp-844 • imp-948 • imp-1044 • imp-1054 • imp-1248 • imp-1354 for cabinet models: • impc-835 • impc-935 • impc-1035.

  • Page 2: Table of Contents

    Table of contents preinstallation instructions for dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 bypass valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3: Bypass Valve:

    Preinstallation instructions for dealers: bypass valve: 3 the manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, and tim...

  • Page 4

    4 1. Normal operation position: the inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During the regeneration cycle this position provides regeneration water t...

  • Page 5: Installation:

    5 general installation & service warnings the control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use vas...

  • Page 6

    6 6. Inlet/outlet plumbing: be sure to install bypass valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydrant and cold hard water lines at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you ...

  • Page 7

    7 caution: never insert a drain line into a drain, sewer line, or trap. Always allow an air gap of 1-1/2" or twice the pipe diameter, whichever is greater, between the drain line and the wastewater to prevent the possibility of sewage being back- siphoned into the conditioner. 9. Brine tank connecti...

  • Page 8: Programming Procedures:

    8 time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. Step 1 – press set clock . Step 2 – current time (hour): set the hour...

  • Page 9

    9 step 4 – regeneration hour: the manufacturer has factory set 2:00 a.M. As the default. This is the hour of day for regeneration and can be reset by using + or — buttons. “am/pm” toggles after 12. The default time is 2:00 a.M. (recommended for a normal household). Press next to go to step 5. Press ...

  • Page 10

    3. Manual regeneration: sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a period of heavy water use is anticipated or when the system has been operated without salt. • to initiate a manual regeneration at the next preset regeneration time, press a...

  • Page 11

    11 5. Error message: if the word “error” and a number are alternately flashing on the display record the number and contact the dealer for help. This indicates that the control valve was not able to function properly. 6. Brine tank maintenance and salt: refill the brine tank as necessary, making sur...

  • Page 12: Start-Up Instructions:

    Start-up instructions: flushing of system: to flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (see fig. 2 of page 4). 2. Turn on inlet water and check for leaks in the newly installed plumbing. 3. ...

  • Page 13

    13 5. Momentarily press regen again until the display reads “rinse.” there should be a rapid flow to the drain. Unplug transformer to keep the valve in the “rinse” position. Allow to run until steady, clear and without air. While the unit is rinsing, load the brine tank with water softener salt (ref...

  • Page 14: Troubleshooting Guide:

    14 problem cause correction 1. No display on pc board a. No power at electric outlet a. Repair outlet or use working outlet b. Control valve power adapter not plugged into outlet or power cord end not connected to pc board connection b. Plug power adapter into outlet or connect power cord end to pc ...

  • Page 15

    15 7. Control valve does not regenerate automatically but does when the correct button(s) is depressed and held. For timeclock valves the buttons are ▲ & ▼ . For all other valves the button is regen. A. Bypass valve in bypass position a. Turn bypass handles to place bypass in service position b. Met...

  • Page 16: Troubleshooting Guide

    16 12. Control valve fails to draw in regenerant a. Injector is plugged a. Remove injector and clean or replace b. Faulty regenerant piston b. Replace regenerant piston c. Regenerant line connection leak c. Inspect regenerant line for air leak d. Drain line restriction or debris cause excess back pr...

  • Page 17

    17 16. E3, err – 1003, err – 103 = control valve motor ran too long and was unable to find the next cycle position a. Motor failure during a regeneration a. Check motor connections then press next and regen buttons for 3 seconds to resynchronize software with piston position or disconnect power supp...

  • Page 18: Replacement Parts:

    18 replacement parts: 2 7 1 3 5 4 6 front cover and drive assembly item no. Part no. Description qty. 1 cv3540-a black impression ® cover 1 cv3540-w-a gray impression ® cover 1 cv3540p-a black impression plus ® cover 1 cv3540p-w-a gray impression plus ® cover 1 2 cv3107-1 motor 1 3 cv3106-1 drive br...

  • Page 19: Replacement Parts:

    6 8 10 11 7 9 7 12 4 2 3 5 1 13 14 note: for impression plus ® models only. Not available on 1¼ " valve. 19 replacement parts: for impression plus ® models only piston assembly item no. Part no. Description qty. 1 cv3005 1" spacer stack assembly 1 cv3430 1.25" spacer stack assembly 1 2 cv3004 drive ...

  • Page 20: Replacement Parts:

    20 replacement parts: bypass valve item no. Part no. Description qty. 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3145 bypass rotor, 1" 2 5 cv3146 bypass cap 2 6 cv3147 bypass handle 2 7 cv3148 bypass rotor seal retainer 2 8 cv3152 o-ring 135 2 9 cv3155 o-ring 11...

  • Page 21: Replacement Parts:

    21 injector assemblies item no. Part no. Description qty. 1 cv3176 injector cap 1 2 cv3152 o-ring 135 1 3 cv3177-01 injector screen 1 4 cv3010-1z injector assembly plug 1 5 cv3010-1a a injector assembly, black 1 cv3010-1b b injector assembly, brown cv3010-1c c injector assembly, violet cv3010-1d d i...

  • Page 22: Replacement Parts:

    22 replacement parts: drain line assembly 3/4" item no. Part no. Description qty. 1 ch4615 elbow locking clip 1 2 cpkp10ts8-bulk optional insert, 5/8" tube 1 3 cv3192 optional nut, 3/4" drain elbow 1 4 cv3158-01 drain elbow, 3/4" npt with o-ring 1 5 cv3163 o-ring 019 1 6 cv3159-01 dlfc retainer asse...

  • Page 23: Replacement Parts:

    23 water meter & meter plug item no. Part no. Description qty. 1 cv3151 nut, 1" qc 1 2 cv3003 meter assembly, includes items 3 & 4 1 3 cv3118-01 turbine assembly 1 4 cv3105 o-ring 215 1 5 cv3003-01 meter plug assembly 1 6 cv3013 optional mixing valve 1 replacement parts: although no tools are necess...

  • Page 24: Replacement Parts:

    24 replacement parts: 2 3 4 5 6 7 8 10 1 9 11 brine tank assembly item no. Part no. Description qty. 1 cg2191- 84 brine tank cover, injection molded wr 1 cg2180 brine tank cover, standard 1 2 ch1095-01 optional 18" diameter salt grid 1 ch1080 optional 24" diameter salt grid 1 3 cg21833cb1c00 18" x 3...

  • Page 25: Replacement Parts:

    25 replacement parts: 1 3 2 see opposite page for safety float system parts. Cabinet brine tank assembly item no. Part no. Description qty. 1 cg 2197-01 salt and tank cover (must be ordered together 1 2 cg2724hp-01 windsor cabinet, white with black lids 1 3 ch1090-01 optional salt grid for 8" diamet...

  • Page 26

    26 1" pvc male npt elbow item no. Part no. Description qty. Cv3007 1" pvc male npt elbow assembly 2 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3149 fitting 2 3/4" & 1" pvc solvent elbow item no. Part no. Description qty. Cv3007- 01 3/4" & 1" pvc solvent elbow as...

  • Page 27

    27 1-1/4" & 1-1/2" pvc solvent item no. Part no. Description qty. Cv3007- 07 1-1/4" & 1-1/2" pvc solvent assembly 2 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3352 fitting 2 1-1/4" & 1-1/2" brass sweat item no. Part no. Description qty. Cv3007- 09 1-1/4 & 1-1/2"...

  • Page 28: Performance Data Sheet:

    28 performance data sheet: width height model imp-844 imp-948 imp-1044 imp-1054 imp-1248 imp-1354 minimum 13,000 @ 3.4 18,000 @ 4.5 18,000 @ 4.5 27,500 @ 7.0 36,000 @ 9.0 45,000 @ 11.5 medium 16,500 @ 6.0 23,000 @ 9.0 23,000 @ 9.0 36,000 @ 15.0 46,000 @ 18.0 53,000 @ 18.0 maximum 18,500 @ 8.0 28,000...

  • Page 29

    29 water conditioner limited warranty congratulations. You have purchased one of the finest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, we proudly warrant our water conditioners to the original owner, when installed in accordance ...

  • Page 30: Notes:

    30 notes:.

  • Page 31

    31.

  • Page 32: Quick Reference Guide:

    1900 prospect court • appleton, wi 54914 phone: 920 - 739-9401 • fax: 920 - 739-9406 manual regeneration note: for softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regeneration. If you need to initiate a manual regeneration, either immediately, or the...