Waterworld new millenium Installation & Service Manual

Manual is about: Reverse Osmosis Drinking Water Systems

Summary of new millenium

  • Page 1

    Installation & service manual reverse osmosis drinking water systems 75 gpd with fully automatic noiseless booster pump.

  • Page 2

    Distributed by: serial #.

  • Page 3

    1 please read this entire service guide prior to beginning installation. Reverse osmosis system with built in pump congratulations on choosing the millennium reverse osmosis system. Our high quality reverse osmosis system has been designed and tested to give you trouble free performance for many yea...

  • Page 4

    2 installation diagram for millennium system (shown with standard faucet) connect to gfi electrical outlet transformer booster pump stage 2: gac carbon 3/8” yellow tubing to tank ro dispensing faucet color coded tubing - standard faucet tubing directions 1/4” green feed water supply line to inlet. F...

  • Page 5

    3 installation diagram for millennium system (shown with optional air gap faucet) connect to gfi electrical outlet transformer 1/4” red tubing air gap to drain clamp 1/4” red tubing to air gap stage 2: gac carbon 3/8” yellow tubing to tank air gap dispensing faucet (optional) booster pump color code...

  • Page 6: Installation Kit Contents

    4 installation kit contents color tubing 1. Color coded tubing: color coded tubing ( 4 coils, 4 colors) ¼’’ green tubing (approximately 8 feet) ¼’’ red tubing (approximately 6 feet) 3/8’’ yellow tubing (approximately 6 feet) 3/8’’ blue tubing (approximately 6 feet) optional 5th coil is added for air...

  • Page 7

    5 tapping into the cold water line a - (using the water supply adaptor part # ppasv121208w ) for flex metal or plastic line. Note: the millennium ® drinking water system must be connected to the cold water supply only. 1) turn off the cold water supply to the sink faucet by locating the round or obl...

  • Page 8

    6 drilling the hole for the faucet note: safety glasses should be worn to protect your eyes while drilling the faucet whole. 1) for best results, a ½” drill bit for a non air gap faucet or 7/8” dill bit for an air gap faucet should be used to drill a hole into your sink for the auxiliary faucet. 2) ...

  • Page 9: Mounting The Faucet

    7 mounting the faucet air gap faucet (optional) 1) drill a 7/8” hole in the sink or the counter top, or use an existing hole. 2) slide chrome cover plate and rubber gasket on to stem of faucet and place faucet onto sink, with the stem going through the hole. 3) place metal slotted washer over thread...

  • Page 10

    8 3) affix sponge provided with the drain clamp onto inside of clamp piece matching the holes. The center hole on the sponge must be removed. 4) make sure to align drain saddle to drilled hole. Attach drain clamp to drain pipe and tighten the two screws evenly (fig. 7) 5) connect the 1/4” red tubing...

  • Page 11: Positioning The System

    9 positioning the system 1) the head assembly will stand up in the sink cabinet or can be hung on screws. 2) the storage tank may be laid on its side. The bladder tank will function both ways horizontal and vertical. 3) the head assembly and/or storage tank may be placed up to 10 feet from the point...

  • Page 12: Start Up Procedure

    10 start up procedure 1) check to see all connections are made 2) check that the pre-filter and pre-carbon sumps are secure with “o” rings in place using the housing wrench provided. 3) slowly turn on the water by turning the needle valve counterclockwise or ball valve 1/4 turn, where handle is para...

  • Page 13: Important Notes-Must Read:

    11 (fig.10) caution: do not use the millennium system on feedwater pressure above 40 psi. If feedwater pressure is above 40 psi, contact your local dealer for an alternative system not equipped with a booster pump. Important notes-must read: 1) your millennium ® system has been thoroughly tested and...

  • Page 14: Changing The Filters

    12 changing the filters caution: any replacement filters or membranes not recommended by the factory can cause severe damage to the system and void all warranties. Maintenance before starting maintenance, check the reverse osmosis system for tds reduction to determine if membranes will or will not n...

  • Page 15

    3 13 symptom cause correction notes: unit fails to produce water 1) water supply is turned off. 1) turn water supply on. 2) check to make sure feed valve is not clogged. 2) not enough water pressure to system. 1) check feed water pressure. Must be at least 10psi. 3) prefilters clogged. 1) change pre...

  • Page 16

    14 millennium ® limited warranty the millennium ® reverse osmosis system is warranted to be free from defects in materials and workmanship under normal use within the operating parameters listed below. For a period of five years from the date of purchase millennium ® will repair or replace any part ...