Xenya XS26GS User Manual

Manual is about: managed optical ethernet switch

Summary of XS26GS

  • Page 1

    Jun ver http:/ man e 15 ,20 sion: 1.0 //www.Xeny x aged 011 01 ya.Si xs26gs ma xs2 optica user anaged optic 26gs al ethe manu cal ethernet ernet s ual t switch use switch er manual h.

  • Page 2

    Xs26gs managed optical ethernet switch user manual i copyright © 2010-2011, xenya d.O.O. All rights reserved this document contains proprietary information that is protected by copyright. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translate...

  • Page 3

    Xs26gs managed optical ethernet switch user manual ii table of contents 1. Introduction .............................................................................. 5 1.1 f eatures ...................................................................................................5 1.2 f ace p anel...

  • Page 4

    Xs26gs managed optical ethernet switch user manual iii 2.11.5 igmp snooping group ...................................................................... 38 2.11.6 link aggregation ............................................................................. 38 2.12 s panning t ree .....................

  • Page 5

    Xs26gs managed optical ethernet switch user manual iv revision history date version description jan 28, 2011 v1.00 initial release jun 15, 2011 v1.01 graphics update.

  • Page 6

    Xs26gs managed optical ethernet switch user manual v 1. Introduction xs26gs managed sfp based optical ethernet switch is a high-performance managed layer 2+ gigabit ethernet switch for service providers. It offers up to twenty-six sfp based gigabit ethernet fiber optic ports. Xs26gs is targeted at t...

  • Page 7

    Xs26gs managed optical ethernet switch user manual 2 z user account assignable to one of the three access privilege levels z on-line firmware upgrade z configuration file backup and restore z dual power supply modules provide power redundancy with status monitoring features. 1.2 face panel the face ...

  • Page 8

    Xs26gs managed optical ethernet switch user manual 3 1.6 default configuration (1) administration ip: ip address: 192.168.0.253 ip sub network: 255.255.255.0 ip gateway: 192.168.0.201 accounts: user level: visitor user administrator user name: guest manager superuser password: (none) 123 123 (2) por...

  • Page 9

    Xs26gs managed optical ethernet switch user manual 4 1.7 management software specification the following table summarizes the protocols supported by the managed optical ethernet switch in the current software release. Tcp/ip arp, icmp, ip, tcp, udp snmp snmp v2(1,2,3,9), fmc private mibs, mib counte...

  • Page 10

    Xs26gs managed optical ethernet switch user manual 5 2. Web management function a web browser has been provided to manage and monitor the switch. The default values are set in section 1.6 of this manual. When logging to the switch, you can browse http://192.168.0.253 and type the user name and passw...

  • Page 11

    Xs26gs managed optical ethernet switch user manual 6 2.3 advanced configuration this page configures whether to globally enable or disable the following protocols: z igmp snooping z gvrp z stp z lacp z authentication z lldp z lbd z lbd interval time z xs view igmp snooping: globally enable or disabl...

  • Page 12

    2.4 this p lbd: lbd contr disab hand, loop i port i disab by de a list 2.4 xs26 to 8 p this p and d manu a man while stati 4.1 port page configu enables loo control: en rol function is ble the port, , if the loopb is found, the if a loop is f bled. Efault, the lo of the port s 4.2 po 6gs switch su p...

  • Page 13

    Xs26gs managed optical ethernet switch user manual 8 port in a static lacp trunk shall have this port’s link lacp enabled. When a static lacp trunk is (manually) deleted, all ports of this trunk with “up” status will generate one or more dynamic lacp trunks automatically. Dynamic lacp aggregation: a...

  • Page 14

    Xs26gs managed optical ethernet switch user manual 9 lacp status setting – sets lacp active or passive for each port active: the port automatically sends lacp protocol packets. Passive: the port does not automatically send lacp protocol packets; it responds only if it receives a lacp protocol packet...

  • Page 15

    2.4 this group moni rx po tx po rx/t monit 4.4 po page config ps,each grou itoring port ort: all ingre ort: all egre tx port: all toring port(s x rt mirro ures the po up can select t: the port o ess traffic of ss traffic of t ingress and s) xs26gs ma oring ort mirroring t one monito r ports to wh th...

  • Page 16

    2.5 this proto vlan 2.5 this p port- 2.5 on th name from mem the b 2.5 there this g there 2.5 vlan managed sw ocol-based v is disabled 5.1 ad page globally based vlan. 5.2 po his page, the e. Up to 256 1 to 4094. Mber: checks bottom part 5.3 80 e is a default group in defa e are three ta .3.1 80 x n...

  • Page 17

    On th group numb the b each note: 2.5 this t for th tagg forwa unta forwa exclu vlan forb indica 2.5 this t pvid will b port. Link block unta when is sim tagg his tag page p name. Up t ber from 1 to bottom part o vlan group : it is not all .3.2 80 tag page con his vlan gro ged: indicate arded by the...

  • Page 18

    Ingre mem all pa fram select tagge the b 2.5 this group type fram type the b 2.5 this p group addr vlan the b ess fliter:w ber of the vl ackages are f me type: ch ted, the por ed packages, bottom part 5.4 pro page configu ps for users t e lists all prot me type cho e.Coresspond bottom part 5.5 ma pa...

  • Page 19

    2.5 2.5 this p vlan 2.5 this a spe switc port: state tpid packe packe preve config z z z z z z z 5.6 vl .6.1 vp page enables n vpn: enab .6.2 vla page enable ecific port. T hes may set : select a spe e:toenale or d: to set tp ets carry spe et is the sam ent confusion gured as a t z arp: 0x0 z ip: 0x...

  • Page 20

    2.5 qinq the in vid, oute inne tag pa and i oute port: the b .6.3 qin is an enhanc nner tag. In t outer tag er tag vid: er tag vid(l ackage, if th inner tag v er tag prior : the double bottom part x nq ced feature o this page, yo priority and a vlan id f low)/ inne e incoming p id(high) (a rity: the...

  • Page 21

    2.5 garp proto befor detai garp time the jo gvrp the r regist and s regist regist the b 2.6 this m 5.7 ga p vlan regi ocol (garp). Re configurin ls). There ar p: this tag pa e must be gr oin time. P: this tag pa registration tration allow static vlans tration, de-re tration, or de bottom part qos ma...

  • Page 22

    Qos p 2.6 this t dscp the b the st 2.6 this p sche (wrr stric weig queue wrr throu priority is dis 6.1 qo tag page sets p enabled, th bottom part o tate of dscp 6.2 sc page sets th eduling mec r). T priority:u ghted roun e scheduling r queue pri ugh 4. The va x sabled in def os conf s per port qo he...

  • Page 23

    2.6 this p the prece 802.1 0 1 2 3 4 5 6 7 2.6 this p 6.3 tra page sets th following ta edence: 1p priority 6.4 ds page sets th x ansmit q e 802.1p pri able lists th scp map e mapping b xs26gs ma queues iority to loca he default m p between the anaged opti s al precedence mapping bet local pre q1 q1...

  • Page 24

    2.7 2.7 there mac a vid: unica port: type mac indica the b addre modif dyna be de forw 7.1 un e are two tag address con specifies a ast mac ad : specifies th e: choose am address en ates a blackh bottom part esses, as we fy or delete mic unicast eleted. X warding nicast m g pages: nfiguration: t vla...

  • Page 25

    2.7 this conta vid: multi mem addre the b inform existi 7.2 mu page sets m ains multicas specifies th icast mac a ber: specifi ess. One or bottom part mation of ea ng multicast x ulticast multicast ma st address, fo he vlan grou address: mu ies forward r more ports of this page ach multicas t mac ad...

  • Page 26

    2.7 there 2.7 in thi the ig the b 2.7 in thi port. The b 2.7 this t rout 7.3 ig e are three t .3.1 igm is page, the gmp snoopin bottom part .3.2 ro is page, the by default, bottom part .3.3 mis tag page se te timeout x mp sno ag pages on mp snoo user can ena ng feature is of this page ute port user ...

  • Page 27

    Time host secon rout igmp quer secon max secon last 1 sec 2.7 mvr( unsub multi mvr but it reaso 2.7 this config mvr multi sourc mvr comp manu config the po the m config dyna port(s multi e, last mem t timeout : nds. Te timeout p querier : ry transmi nds. Response nds. Member q cond. 7.4 mv (multicas...

  • Page 28

    Table sour ports switc rece receiv becom mess 2.7 this p multi grou the b 2.7 unkn statu the b to forward o rce port: co . Subscriber h are memb eive port: co ve multicast mes a mem ages. Receiv .4.2 m page sets sp icast vid: m up ip addre bottom part 7.5 un nown mult us for this vl bottom part x or...

  • Page 29

    2.8 2.8 this p ip, a serve auth unica auth the d auth from acco valid acco defau acco 1 to 1 2.8 there 802.1 secu 8.1 ma page configu authenticat er ip, acco hentication st address in hentication efault value hentication 1 to 15 char ounting rad unicast addr ounting port ult value is 1 ounting sha 1...

  • Page 30

    Xs26gs managed optical ethernet switch user manual 25 2.8.2.1 802.1x port this tag page sets 802.1x port enabling, re-authentication, access control, and guest vlan for a specified ethernet port. There are three choices for portcontrol: auto, forceauthorized, and forceunauthorized. Auto: specified t...

  • Page 31

    Xs26gs managed optical ethernet switch user manual 26 the switch does not perform any 802.1x authentication-related actions for the supplicant system. The value is in the range of 1 to 65535, and is set to 60 seconds by default. Tx period: sets the transmission timer. This timer sets the tx-period a...

  • Page 32

    Xs26gs managed optical ethernet switch user manual 27 2.8.3 mac authentication 2.8.3.1 port conf this page enables mac authentication on a specific port. 2.8.3.2 misc this page sets offine detect time, quiet period, and server timeout for mac authentication. Offline detect time: to check whether the...

  • Page 33

    Xs26gs managed optical ethernet switch user manual 28 port,and authenticate state. 2.8.4 ip binding this page sets ip address, unicast mac address, and port for ip binding. The bottom part of this page lists all the ip binding information. 2.8.5 storm control this page sets thresholds of the specifi...

  • Page 34

    Xs26gs managed optical ethernet switch user manual 29 collection of permit and deny conditions that apply to packets. When a packet is received on an interface, the switch compares the fields in the packet against any applied acls to verify that the packet has the required permissions to be forwarde...

  • Page 35

    Xs26gs managed optical ethernet switch user manual 30 2.9.2.2 advanced ip acl this page sets acl rules based on packet src ip address, dst ip address, ip protocol type and other protocol features, such as tcp or udp source port, destination port, icmp protocol message types etc. Rule id: identificat...

  • Page 36

    Xs26gs managed optical ethernet switch user manual 31 2.9.2.3 l2 acl this page sets src mac address, src mac address mask, dst mac address, and dst mac address mask, and the action that can be selected as permit or deny. Rule id: identification the acl rule. Src mac address: source host mac address....

  • Page 37

    Xs26gs managed optical ethernet switch user manual 32 2.9.3 port binding this page sets the binding of an ethernet port to a specified acl id. If a port is bound, it will take effect on all the rules associated to this acl id. The bottom part of this page lists all acl binding ports. 2.10 lldp lldp ...

  • Page 38

    Xs26gs managed optical ethernet switch user manual 33 2.10.1.2 tlvs this page sets the type of transmitted information: port description, system name, system description, system capability, and management. Port description: identifies information of the interface, including the name of manufacturer,...

  • Page 39

    Xs26gs managed optical ethernet switch user manual 34 32768 seconds. The default value is 30 seconds. Tx hold: ttl multiplier. Ttl of tlv carried in lldpdu is used to set the aging time on the neighbor device. Since ttl of tlv = ttl multiplier × tx interval, the aging time on the neighbor device can...

  • Page 40

    Xs26gs managed optical ethernet switch user manual 35.

  • Page 41

    Xs26gs managed optical ethernet switch user manual 36 2.11 statistics all the pages in this menu show various statistics information of the switch. 2.11.1 port status this page shows the state, link, negotiation, speed&duplex, flow control, learning of each ethernet port. 2.11.2 port statistics this...

  • Page 42

    Xs26gs managed optical ethernet switch user manual 37 2.11.3 vlan list this page lists the information of all vlans, including vid, name, type, tagged, untagged, and forbidden. Type includes static or dynamic. Tagged lists all ports out of which packets are sent tagged , untagged lists all ports out...

  • Page 43

    Xs26gs managed optical ethernet switch user manual 38 2.11.5 igmp snooping group this page shows igmp snooping multicast group information, including vid, multicast group, mac address, and member ports. Multicast group is the ip address of a multicast group, mac address is the address of a mac multi...

  • Page 44

    Xs26gs managed optical ethernet switch user manual 39 static trunking group: shows static trunk information, including trunk id, trunk name, type, and port list. Type is fixed to static. Lacp trunking group: shows lacp trunk information, including priority, mac of actor and partner. It also shows th...

  • Page 45

    Xs26gs managed optical ethernet switch user manual 40 the spanning tree will be recalculated at bpdu packet times out. When a switch becomes a root bridge, it regularly sends bpdus at the interval specified by this hello time. A non-root-bridge switch adopts the interval specified by this hello time...

  • Page 46

    Xs26gs managed optical ethernet switch user manual 41 priority, and root guard for each port, and also can set path cost and priority. Edge port: selects enabled to configure the specified ethernet port as an edge port. By default, all ethernet ports are non-edge ports. An edge port is such a port t...

  • Page 47

    Xs26gs managed optical ethernet switch user manual 42 2.12.2.2 ports state this page lists all port parameters and spanning tree information, including stp, state, priority, cost, role, designated port id, designated root id, and designated bridge id..

  • Page 48

    Xs26gs managed optical ethernet switch user manual 43 2.12.2.3 bridge information this page lists basic information of designated bridge, including bridge id, root bridge id, root port, and root path cost. Bridge id: id of this switch. Root bridge id: id of the root bridge. Root port: the spanning t...

  • Page 49

    2.12 this p be as the b 2.3.3 vla page maps o ssigned to a bottom part x an map ne or more v spanning-tre of this page xs26gs ma vlans into a ee instance a lists the vla anaged opti specific mst at a time. An mapping cal ethernet t instance. O table. T switch use one or more v er manual vlans can.

  • Page 50

    Xs26gs managed optical ethernet switch user manual 45 2.12.4 mstp ports 2.12.4.1 configuration this page enables admin, edge port, p2p, and external cost for each port. Similar to stp and rstp port configuration described in section 2.12.2.1 ports configuration, this page sets mstp port configuratio...

  • Page 51

    Xs26gs managed optical ethernet switch user manual 46 2.12.5 mstp state this page lists spanning tree information: bridge id, root bridge id, external path cost, internal path cost, and root port for each mst instance. 2.13 snmp manager 2.13.1 snmp account there are three tag pages: snmp view, snmp ...

  • Page 52

    Xs26gs managed optical ethernet switch user manual 47 2.13.1.2 snmp community this page sets snmp version between v1 and v2c; community name, and privilege between ro and rw. V1: creates an snmpv1 user. V2c: creates an snmpv2c user. Community name: name of the community to be created. It is a string...

  • Page 53

    Xs26gs managed optical ethernet switch user manual 48 2.13.1.3 snmp user this page creates a snmp v3 user, and sets usm user, privilege, snmp v3 encryption, auth algorithm, auth password, privacy algorithm, and privacy password. Usm user: username, a string of 3 to 16 characters. Auth algorithm: spe...

  • Page 54

    Xs26gs managed optical ethernet switch user manual 49 host ip address. Trap port: disables or enables the trap function for each port. The bottom part of this page lists the trap status of all ports. 2.14 administration this part covers switch management and maintenance functions. 2.14.1 ip configur...

  • Page 55

    Xs26gs managed optical ethernet switch user manual 50 2.14.2 ping diagnosis this page can be used to ping a specific ip address. 2.14.3 account this page can be usedtoadd a new account. Username, password, and privilege for the new account are set on this page. Username: username, a string of 3 to 1...

  • Page 56

    Xs26gs managed optical ethernet switch user manual 51 2.14.4 tftp services there are three tag pages. Update firmware: this page sets a tftp server ip and firmware name. Before doing firmware upgrade, make sure the switch is connected to the tftp server and new firmware file exists on the server. Th...

  • Page 57

    Xs26gs managed optical ethernet switch user manual 52 restore configuration: this page sets a tftp server ip and file name. Before restoring a configuration, make sure the switch is connected to the tftp server. The switch will download the file with the specified file name and use it as the configu...

  • Page 58

    Xs26gs managed optical ethernet switch user manual 53 reset to default: the switch will be reset to the factory default setting. 2.14.7 save configuration this page saves current configurations. 2.14.8 system logs this page shows all of the system logs, clicking “clear” button to clear all the recor...

  • Page 59

    Xs26gs managed optical ethernet switch user manual 54 2.15 logout click “logout” in the left menu to log out from the switch and close the browser..

  • Page 60

    Xs26gs managed optical ethernet switch user manual 55 3. Command line interface (cli) 3.1 error message if an incorrect parameter is entered, or the command cannot be executed, one of the following error messages will be displayed on screen. Z incomplete command z wrong type parameter z wrong parame...

  • Page 61

    Xs26gs managed optical ethernet switch user manual 56 【ctrl】+【c】 skip the current command and go to a new line. Page shortcuts list: shortcuts explanation any key except 【enter】and【q】 shows the next page. 【q】 stops the displaying. 【enter】 shows the next line. 3.4 cli command modes these are the view...

  • Page 62

    Xs26gs managed optical ethernet switch user manual 57 mst-regio n view from system view, enter the spanning-tree mst-region view command xs(mst-region)# to exit to system view, enter the end command, or press ctrl-z ip-bindin g view from system view, enter the ip-binding view command xs(ip-binding)#...

  • Page 64

    Xs26gs managed optical ethernet switch user manual 59 any view. Parameters none. Description use show ipconfig command to display the ip address of the switch, including ip address, ip netmask, and ip gateway. Examples xs# show ipconfig operation mode: manual setting ip address: 192.168.0.253 ip net...

  • Page 65

    Xs26gs managed optical ethernet switch user manual 60 parameters none. Description use show history command to list history commands of the current user. History commands are those commands that were successfully executed previously and saved in the history command buffer. When the history command b...

  • Page 66

    Xs26gs managed optical ethernet switch user manual 61 description use show system-information command to display the basic information of the switch, including system name, system description, system location, system contact, hardware version, firmware version, boot loader version, mac address, and ...

  • Page 67

    Xs26gs managed optical ethernet switch user manual 62 none description use show temperature command to display the current environmental temperature of switch. Example xs# show temperature current temperature: 46.5 degree celsius show fan-status syntax show fan-status view any view parameters none d...

  • Page 68

    Xs26gs managed optical ethernet switch user manual 63 power a status : off power b status : off show local-time syntax show local-time view any view parameters none description use show local-time command to display the current and local time. Example xs# show local-time local time: tue oct 13 10:19...

  • Page 69

    Xs26gs managed optical ethernet switch user manual 64 show running-config syntax show running-config view any view parameters none description use show running-config command to display which configuration you have set. Example xs# show running-config current running configuration: acl configuration...

  • Page 70

    Xs26gs managed optical ethernet switch user manual 65 none. Description use disable command to log out from the current user. Examples xs# disable exit current level successfully! Xs> enable syntax enable view system view. Parameters none. Description use enable command to log in as another user. Ex...

  • Page 72

    Xs26gs managed optical ethernet switch user manual 67 echo-request packet to the destination host. Then, if the connection to the destination network is normal, the destination host receives this packet and responds with an icmp echo-reply packet. You can use ping command to check the network connec...

  • Page 73

    Xs26gs managed optical ethernet switch user manual 68 none. Description use reset configuration command to make all of the factory default settings to be restored on the switch. When asked “do you want to reset all the configurations except ip address and user account? (y/n)” , if you choose “y”, th...

  • Page 74

    Xs26gs managed optical ethernet switch user manual 69 put: specified to upload a file to the tftp server. Dest-file: file name used when a file is uploaded and saved to a tftp server. Description use tftp tftp-server command to connect to a tftp server and perform download or upload operations. Uplo...

  • Page 75

    Xs26gs managed optical ethernet switch user manual 70 description use xs-view command to enable the xs view network management function. Use no xs-view command to disable the xs view network management function. Examples xs# xs-view xs view function has been enabled successfully. Xs# no xs-view xs v...

  • Page 78

    Xs26gs managed optical ethernet switch user manual 73 syntax show storm-control view any view. Parameters none. Description use show storm-control command to display the storm control configurations. Examples xs(vlan2)# show storm-control show storm-control information type :broadcast rate :1000pps ...

  • Page 79

    Xs26gs managed optical ethernet switch user manual 74 parameters none. Description use end command to exit from the ethernet port configuration environment. Examples xs(ethernet0/9)# end xs# shutdown syntax shutdown no shutdown view ethernet port view. Parameters none. Description use shutdown comma...

  • Page 80

    Xs26gs managed optical ethernet switch user manual 75 description use speed command to set the port speed. Use no speed command to restore the port speed to the default setting. By default, the port speed is in the auto-negotiation mode. Note that you can only specify the 1000 and auto keyword for g...

  • Page 81

    Xs26gs managed optical ethernet switch user manual 76 description use flow-control command to enable flow control on the ethernet port. Use no flow-control command to disable flow control on the port. In the case that flow control is enabled on both the local and peer switches, when congestion occur...

  • Page 82

    Xs26gs managed optical ethernet switch user manual 77 rate rate-value: the upper rate threshold of the port. The rate-value is one of 64k,128k,192k,256k,320k,484k,512k,640k,768k,896k,1m,2m,4m,8m,10m,15m, 20m,30m,40m,50m,60m,70m,80m,90m description use line-rate command to configure the upper thresho...

  • Page 83

    Xs26gs managed optical ethernet switch user manual 78 parameters type type: type is in the range from 1 to 7. 1:broadcast 2:multicast 3:destination lookup failed(dlf) 4:broadcast+multicast 5:broadcast+dlf 6:multicast+dlf 7:broadcast+multicast+dlf rate rate: rate is in the range from 1 to 262143. Des...

  • Page 84

    Xs26gs managed optical ethernet switch user manual 79 syntax show lacp system-id view any view. Parameters none. Description use show lacp system-id command to display the device id of the local system, including system priority and mac address. Examples xs(ethernet0/8)# show lacp system-id lacp sys...

  • Page 85

    Xs26gs managed optical ethernet switch user manual 80 ethernet0/12 - ethernet0/13 - ethernet0/14 - ethernet0/15 - ethernet0/16 - ethernet0/17 - ethernet0/18 - ethernet0/19 - ethernet0/20 - ethernet0/21 - ethernet0/22 - ethernet0/23 - ethernet0/24 - ethernet1/1 - ethernet1/2 - ethernet1/3 - ethernet1...

  • Page 86

    Xs26gs managed optical ethernet switch user manual 81 any view. Parameters none. Description use show link-aggregation summary command to display summary information of all aggregation groups. Examples xs# show link-aggregation summary 1:00-0a-0b-0c-0e-09 la la partner selected id type id ports ----...

  • Page 87

    Xs26gs managed optical ethernet switch user manual 82 lacp no lacp view system view, ethernet port view. Parameters none. Description use lacp command to enable lacp globally in system view or enable lacp on the port in ethernet port view. Use no lacp command to disable lacp globally in system view ...

  • Page 88

    Xs26gs managed optical ethernet switch user manual 83 link-aggregation group agg-id description agg-name no link-aggregation group agg-id description view system view. Parameters agg-id: aggregation group id, in a range from 1 to 13. Agg-name: aggregation group name, a string of 1 to 32 characters. ...

  • Page 89

    Xs26gs managed optical ethernet switch user manual 84 lacp port-priority port-priority no lacp port-priority view ethernet port view. Parameters port-priority: port priority, ranging from 1 to 65,535. Description use lacp port-priority command to set priority of the port. Use undo lacp port-priority...

  • Page 90

    Xs26gs managed optical ethernet switch user manual 85 3.10 mirroring commands the “any view” in the below table refers to anyone of the following: system view, ethernet port view, port-based vlan view, vlan view, or dot1x view. Command list: view command system view mirror group groupid mirror group...

  • Page 91

    Xs26gs managed optical ethernet switch user manual 86 xs(mirror-1)# no mirror-group the mirror group have been deleted successfully. Show mirror syntax show mirror view any view. Parameters none. Description use show mirror command to display the port mirroring configurations. Examples xs# show mirr...

  • Page 92

    Xs26gs managed optical ethernet switch user manual 87 use monitor-port command to configure the destination port. You can use to ethernet interface to configure a range of continuous destination ports. Examples xs(mirror-1)# monitor-port ethernet 0/20 configuration completed successfully. Mirroring-...

  • Page 96

    Xs26gs managed optical ethernet switch user manual 91 all: deletes all vlans. Description use vlan command to enter into vlan configuration environment. Use no vlan command to delete all vlans or specified vlan(s). Examples xs# vlan 2 xs(vlan2)# end syntax end view vlan view. Parameters none. Descri...

  • Page 98

    Xs26gs managed optical ethernet switch user manual 93 ipx: creates the ipx-based protocol template. Mode: configures a user-defined protocol template. Ethernetii etype-id: creates the protocol template that matches the ethernet ii encapsulation format and the corresponding protocol type value of the...

  • Page 99

    Xs26gs managed optical ethernet switch user manual 94 vlan view. Parameters none. Description use unknown-multicast-flood command to enable the unknown multicast flood status for this vlan group. Use no unknown-multicast-flood command to disable the unknown multicast flood status for this vlan group...

  • Page 100

    Xs26gs managed optical ethernet switch user manual 95 view vlan view. Parameters vlan-id: specifies the id of a vlan the information of which is to be created, in a range from 1 to 4094. Vlan-id1: specifies the id of a vlan the information of which is to be deleted, in the range of 1 to 4094. To vla...

  • Page 102

    Xs26gs managed optical ethernet switch user manual 97 switchport protected no switchport protected view ethernet port view parameters none. Description use switchport protected command to enable switchport protected function for the specified switch interface. Use no switchport protected command to ...

  • Page 103

    Xs26gs managed optical ethernet switch user manual 98 ingress-filtering has been disabled successfully! 3.11.2 port-based vlan configuration commands the “any view” in the below table refers to anyone of the following: system view, ethernet port view, port-based vlan view, vlan view, or dot1x view. ...

  • Page 105

    Xs26gs managed optical ethernet switch user manual 100 description syntax description name view port-based vlan view. Parameters name: vlan name, a description of 1 to 255 characters. It can contain special characters, but cannot be spaces. Description use description command to assign a name to the...

  • Page 106

    Xs26gs managed optical ethernet switch user manual 101 3.12 vlan vpn the “any view” in the below table refers to anyone of the following: system view, ethernet port view, port-based vlan view, vlan view, or dot1x view. Command list: view command any view show vlan-vpn system view vlan-vpn no vlan-vp...

  • Page 107

    Xs26gs managed optical ethernet switch user manual 102 ethernet0/10 disabled 0x8100 ethernet0/11 disabled 0x8100 ethernet0/12 disabled 0x8100 ethernet0/13 disabled 0x8100 ethernet0/14 disabled 0x8100 ethernet0/15 disabled 0x8100 ethernet0/16 disabled 0x8100 ethernet0/17 disabled 0x8100 ethernet0/18 ...

  • Page 108

    Xs26gs managed optical ethernet switch user manual 103 parameters tpid(tag protocol identifier): includes an ethernet type value that is used to identify the frame as a tagged frame and to select the correct tag decoding functions. Description use vlan-vpn tpid command to set a tpid value. Use no vl...

  • Page 110

    Xs26gs managed optical ethernet switch user manual 105 none. Description use show gvrp status command to display the gvrp settings of all ports. Examples xs# show gvrp status gvrp feature is currently enabled on this switch! Ports gvrp-status registration -------- ----------------- -----------------...

  • Page 111

    Xs26gs managed optical ethernet switch user manual 106 2147483640, the default value is 10000 milliseconds. Timer-value: timeout time (in milliseconds) of the garp timer (hold, join, leave or leaveall ) to be set. Description use garp timeout command to set a garp timer. Use no garp timeout command ...

  • Page 112

    Xs26gs managed optical ethernet switch user manual 107 propagates only static vlan information to the other garp members. Forbidden: specifies the forbidden gvrp registration mode. A port operating in this mode cannot register or deregister vlan information dynamically. It permits only vlan 1, that ...

  • Page 113

    Xs26gs managed optical ethernet switch user manual 108 syntax show qos queue-scheduler view any view. Parameters none. Description use show qos queue-scheduler command to display the global queue scheduling configuration. Examples xs# show qos queue-scheduler queue scheduling mode: weighted round ro...

  • Page 114

    Xs26gs managed optical ethernet switch user manual 109 queue :0 0 1 1 2 2 3 3 show qos map dscp cos syntax show qos map dscp cos view any view. Parameters none. Description use show qos map dscp cos command to display the mapping of dscp priority to 802.1p priority, illustrated by a dscp priority to...

  • Page 115

    Xs26gs managed optical ethernet switch user manual 110 #display the qos information of all ports xs# show qos interface port default priority dscp ----------- -------------------- ------ ethernet0/1 0 disabled ethernet0/2 0 disabled ethernet0/3 0 disabled ethernet0/4 0 disabled ethernet0/5 0 disable...

  • Page 116

    Xs26gs managed optical ethernet switch user manual 111 description use qos queue-scheduler command to configure the queue scheduling algorithm and the related parameters. Use no qos queue-scheduler command to restore to the default setting. By default, the sp algorithm is used for all output queues ...

  • Page 117

    Xs26gs managed optical ethernet switch user manual 112 5 2 6 3 7 3 examples xs# qos cos-local-precedence-map 3 3 2 2 1 1 0 0 the configuration succeeds. Qos map syntax qos map dscp dscp to cos cos no qos map dscp dscp view system view. Parameters dscp dscp: the dscp priority, this argument ranges fr...

  • Page 118

    Xs26gs managed optical ethernet switch user manual 113 xs(ethernet0/1)# qos-mode dscp dscp is enabled on port ethernet0/1. Priority syntax priority priority-level no priority view ethernet port view parameters priority-level: port priority, ranging from 0 to 7. Description use priority command to se...

  • Page 120

    Xs26gs managed optical ethernet switch user manual 115 00-1d-7d-41-46-09 3 dynamic ethernet0/7 yes 00-0a-0b-0c-0e-09 3 learned cpu yes 00-1a-4d-23-32-0a 3 learned ethernet0/7 yes 00-16-ec-5a-b6-fe 3 dynamic ethernet0/7 yes 00-1a-4d-3a-2a-d8 3 learned ethernet0/7 yes 00-1d-72-09-fa-b4 3 learned ether...

  • Page 121

    Xs26gs managed optical ethernet switch user manual 116 dynamic: displays dynamic mac address entries. Blackhole: displays blackhole mac address entries. Interface ethernet interface-number: specifies a port by its interface type and number, of which the mac address entries are displayed. Vlan vlan-i...

  • Page 122

    Xs26gs managed optical ethernet switch user manual 117 interface ethernet interface-number: specifies the outgoing port by its type and number for the mac address. All traffic destined for the mac address will be sent out from the port. Vlan vlan-id: specifies a vlan id, in a range from 1 to 4094. T...

  • Page 123

    Xs26gs managed optical ethernet switch user manual 118 setting an appropriate mac address aging timer is important for the switch to run efficiently. Z if the aging timer is set too short, the mac address entries that are still valid may be removed due to aging. Upon receiving a packet destined for ...

  • Page 124

    Xs26gs managed optical ethernet switch user manual 119 description use show mac-address multicast command to display the information of the multicast mac address entry or entries manually configured on the switch. Examples xs# show mac-address multicast show all of the multicast mac-address vlan id ...

  • Page 125

    Xs26gs managed optical ethernet switch user manual 120 entry on the port. Use no mac-address multicast vlan command to remove the specified multicast mac address entry or all multicast mac address entries on the port. Each multicast mac address entry contains multicast address, forward port, vlan id...

  • Page 126

    Xs26gs managed optical ethernet switch user manual 121 none. Description use show igmp-snooping configuration command to display igmp snooping configuration information. If igmp snooping is disabled, this command displays a message showing that igmp snooping is not enabled. With igmp snooping enable...

  • Page 127

    Xs26gs managed optical ethernet switch user manual 122 show igmp-snooping group information vlan id :1 multicast group :239.0.0.10 mac address :01-00-5e-00-00-0a port member :ethernet0/4, total entries : 1 igmp-snooping syntax igmp-snooping no igmp-snooping view system view, vlan view. Parameters no...

  • Page 128

    Xs26gs managed optical ethernet switch user manual 123 xs# igmp-snooping querier igmp querier has been enabled. Xs# no igmp-snooping querier igmp querier has been disabled. Igmp-snooping query-interval syntax igmp-snooping query-interval [time seconds] no igmp-snooping query-interval view system vie...

  • Page 129

    Xs26gs managed optical ethernet switch user manual 124 aging time. By default, the aging time of multicast member ports is 260 seconds. The aging time of multicast member ports determines the refresh frequency of multicast group members. In an environment where multicast group members change frequen...

  • Page 130

    Xs26gs managed optical ethernet switch user manual 125 by default, the leave timer is 30 seconds. Examples xs# igmp-snooping leave-time 200 leave-time of igmp-snooping set to 200 seconds igmp-snooping max-response-time syntax igmp-snooping max-response-time seconds no igmp-snooping max-response-time...

  • Page 131

    Xs26gs managed optical ethernet switch user manual 126 use multicast static-router-port command to configure the specified port in the vlan as a static router port. Use no multicast static-router-port command to remove the specified port from the vlan as a static router port. By default, a port is n...

  • Page 132

    Xs26gs managed optical ethernet switch user manual 127 status: displays the information of 802.1x. Interface: displays the 802.1x-related information of all ports. Ethernet interface: displays the 802.1x-related information of a specified port. Interface : ethernet port, in the form of interface = {...

  • Page 133

    Xs26gs managed optical ethernet switch user manual 128 ethernet0/16 disabled forceauthorized disabled link down ethernet0/17 disabled forceauthorized disabled link down ethernet0/18 disabled forceauthorized disabled link down ethernet0/19 disabled forceauthorized disabled link down ethernet0/20 disa...

  • Page 134

    Xs26gs managed optical ethernet switch user manual 129 xs(dot1x)# end xs# max-req syntax max-req max-retry-value view dot1x view parameters max-retry-value: maximum number of times that a switch sends authentication request packets to a user. This argument ranges from 1 to 10. Description by default...

  • Page 135

    Xs26gs managed optical ethernet switch user manual 130 the quiet-period timer is set to 60 seconds. Reauth-period reauth-period-value: specifies re-authentication interval, in seconds. After this timer expires, the switch initiates 802.1x re-authentication. The value of the reauth-period-value argum...

  • Page 136

    Xs26gs managed optical ethernet switch user manual 131 none. Description use system-auth-control command to enable 802.1x globally. Use no system-auth-control command to disable 802.1x globally. Examples xs(dot1x)# system-auth-control 802.1x is enabled the configuration succeeds. Radius-server synta...

  • Page 137

    Xs26gs managed optical ethernet switch user manual 132 none. Description use dot1x command to enable 802.1x for the specified ethernet port. Use no dot1x command to disable 802.1x for the specified ethernet port. Examples xs(ethernet0/1)# dot1x 802.1x is enabled on port ethernet0/1 dot1x re-authenti...

  • Page 138

    Xs26gs managed optical ethernet switch user manual 133 network resources without the need of authentication. Forceunauthorized: specified to operate in forceunauthorized access control mode. When a port operates in this mode, the hosts connected to it cannot access the network resources. Description...

  • Page 139

    Xs26gs managed optical ethernet switch user manual 134 system view spanning-tree mst-region mst-region view instance msti no instance msti mst-region view instance msti ethernet ethernet-port path-cost cost no instance msti ethernet ethernet-port path-cost pri mst-region view instance msti ethernet ...

  • Page 140

    Xs26gs managed optical ethernet switch user manual 135 ethernet0/2 enabled 128 auto designated disabled 1:128 ethernet0/3 enabled 128 auto designated disabled 2:128 ethernet0/4 enabled 128 auto designated disabled 3:128 ethernet0/5 enabled 128 auto designated disabled 4:128 ethernet0/6 enabled 128 a...

  • Page 141

    Xs26gs managed optical ethernet switch user manual 136 lbd: disabled path cost: 20000 port priority: 128 stp state: disabled stp role: disabled desigated port id: 0-0 designated path cost: 0 designated bridge id: 0:00-00-00-00-00-00 show spanning-tree syntax show spanning-tree {ethernet ethernet-por...

  • Page 142

    Xs26gs managed optical ethernet switch user manual 137 ethernet0/1 128 0 disabled disabled 32768:28b0cc0031d4 128:1 ethernet0/2 128 0 disabled disabled 32768:28b0cc0031d4 128:2 ethernet0/3 128 0 disabled disabled 32768:28b0cc0031d4 128:3 ethernet0/4 128 0 disabled disabled 32768:28b0cc0031d4 128:4 e...

  • Page 143

    Xs26gs managed optical ethernet switch user manual 138 system view, ethernet port view parameters none. Description use spanning-tree command to enable stp globally (in system view) or for a port (in ethernet port view). Use no spanning-tree command to disable stp globally (in system view) or for a ...

  • Page 144

    Xs26gs managed optical ethernet switch user manual 139 xs# spanning-tree forward-time 17 configure successfully spanning-tree hello-time syntax spanning-tree hello-time timer-value no spanning-tree hello-time view system view parameters timer-value: hello time in seconds to be set. This argument ran...

  • Page 145

    Xs26gs managed optical ethernet switch user manual 140 description use spanning-tree max-age command to set the max age. Use no spanning-tree max-age command to restore to the default max age. By default, the max age of a switch is 20 seconds. To set the three time-related parameters (hello time, fo...

  • Page 146

    Xs26gs managed optical ethernet switch user manual 141 description use spanning-tree max-hops command to set the mstp max-hops. Use no spanning-tree max-hops command to restore the max-hops to default value. The default max-hops are 20. Examples xs# spanning-tree max-hops 18 configure successfully s...

  • Page 147

    Xs26gs managed optical ethernet switch user manual 142 parameters none. Description use spanning-tree bpdu-guard command to enable the bpdu-guard. Use no spanning-tree bpdu-guard command to disable the bpdu-guard. Examples xs# spanning-tree bpdu-guard set successfully spanning-tree hold-count syntax...

  • Page 148

    Xs26gs managed optical ethernet switch user manual 143 use spanning-tree root-guard command to enable the root protection function for a specified port on the switch. Use no spanning-tree root-guard command to disable the root protection for a specified port on the switch. Examples xs(ethernet0/1)# ...

  • Page 149

    Xs26gs managed optical ethernet switch user manual 144 description use spanning-tree priority command to set a port priority for the specified ports. Use no spanning-tree priority command to restore to the default priority of the specified ports. Examples xs(ethernet0/1)# spanning-tree priority 200 ...

  • Page 150

    Xs26gs managed optical ethernet switch user manual 145 description use spanning-tree protocol-migration command to enable the protocol migration feature. Use no spanning-tree protocol-migration command to disable the protocol migration feature. By default, the protocol migration feature is enabled. ...

  • Page 151

    Xs26gs managed optical ethernet switch user manual 146 view system view. Parameters none. Description use spanning-tree mst-configuration command to enter mst-region configuration environment. Examples xs# spanning-tree mst-region xs(mst-region)# instance syntax instance msti no instance msti view m...

  • Page 153

    Xs26gs managed optical ethernet switch user manual 148 instance msti priority pri no instance msti priority pri view mst-region view parameters msti:instance id pri: the priority for the specified instance. It is in the range of 0 to 65535, the default value is 32768. Description use instance msti p...

  • Page 154

    Xs26gs managed optical ethernet switch user manual 149 region-name syntax region-name name view mst-region view parameters name: a variable length text string encoded within a fixed field of 32 octets description use region-name command to set the configuration name of mst configuration identificati...

  • Page 156

    Xs26gs managed optical ethernet switch user manual 151 none. Description use show snmp community command to display the information of snmpv1/snmpv2c communities. Snmpv1 and snmpv2c use community name authentication. Therefore, the snmpv1 and snmpv2c messages carry community names; if the carried co...

  • Page 157

    Xs26gs managed optical ethernet switch user manual 152 xs# show snmp user ver user authtype: authpwd privtype: privpwd privilege --- ---------------- -------------------- -------------------- --------- v3 user1 : : rw v3 user2 md5:useruser2222 : rw v3 user3 md5:agewhrjykkl des:sageriutu6ui rw show s...

  • Page 158

    Xs26gs managed optical ethernet switch user manual 153 ethernet 0/2 enable ethernet 0/3 enable ethernet 0/4 enable ethernet 0/5 enable ethernet 0/6 enable ethernet 0/7 enable ethernet 0/8 enable ethernet 0/9 enable ethernet 0/10 enable ethernet 0/11 enable ethernet 0/12 enable ethernet 0/13 enable e...

  • Page 159

    Xs26gs managed optical ethernet switch user manual 154 syntax snmp-server community no snmp-server community community-name view system view. Parameters community-name: name of the community to be created; it is a string of 3 to 16 characters. Description use snmp-server community command to create ...

  • Page 160

    Xs26gs managed optical ethernet switch user manual 155 which is more secure than des. Priv-password: encryption password, a string of 1 to 64 characters in plain text, a 32-bit hexadecimal number in cipher text if md5 algorithm is used, and a 40-bit hexadecimal number in cipher text if sha algorithm...

  • Page 161

    Xs26gs managed optical ethernet switch user manual 156 snmp-server traps-host syntax snmp-server traps-host host-ip no snmp-server traps-host host-ip view system view. Parameters host-ip: specifies the destination for the snmp traps. Description use snmp-server traps-host command to set a destinatio...

  • Page 162

    Xs26gs managed optical ethernet switch user manual 157 xs(ethernet0/23)# snmp-traps enable this interface snmp trap (sending linkup or linkdown) successfully! 3.21 system log commands the “any view” in the below table refers to anyone of the following: system view, ethernet port view, port-based vla...

  • Page 163

    Xs26gs managed optical ethernet switch user manual 158 clear all the logs that were saved in the system. Examples xs# no log clear all the logs successfully! 3.22 lldp configuration commands the “any view” in the below table refers to anyone of the following: system view, ethernet port view, port-ba...

  • Page 165

    Xs26gs managed optical ethernet switch user manual 160 lldp timer tx-interval syntax lldp timer tx-interval interval view system view parameters interval: required, between 5 to 32768 seconds, 30 seconds by default. Description set the interval to send lldpdus. Examples xs# lldp timer tx-interval 50...

  • Page 166

    Xs26gs managed optical ethernet switch user manual 161 description set the initialization delay period. Examples xs# lldp timer reinit-delay 3 set successfully! Lldp hold-multiplier syntax lldp hold-multiplier value view system view parameters value: required, range between 1 to 10, 5 by default. De...

  • Page 168

    Xs26gs managed optical ethernet switch user manual 163 show lldp statistics view any view parameters none description display the lldp statistics. Examples xs# show lldp statistics ethernet0/1 transmit frames : 0 receive frames : 0 receive error frames : 0 discarded frames : 0 tlvs discarded packets...

  • Page 169

    Xs26gs managed optical ethernet switch user manual 164 ethernet0/4 enable disable ethernet-ii ethernet0/5 enable disable ethernet-ii ethernet0/6 enable disable ethernet-ii show lldp tlv-config syntax show lldp tlv-config view any view parameters none description display the types of the lldp tlvs th...

  • Page 173

    Xs26gs managed optical ethernet switch user manual 168 ports. Use no user-bind ethernet ethernet-port command to clear all the port binding commands of a specific port. Use no user-bind mac-addr mac ip-addr ip ethernet ethernet-port command to clear a specific port binding command. Examples xs(ip-bi...

  • Page 174

    Xs26gs managed optical ethernet switch user manual 169 mvr syntax mvr view system view parameters none description use mvr to enable global mvr. Use no mvr to disable global mvr. Examples xs# mvr enable mvr mvr group syntax mvr group mvr-group no mvr group mvr-group view system view parameters mvr-g...

  • Page 175

    Xs26gs managed optical ethernet switch user manual 170 parameters source: set uplink ports that receive and send multicast data as source ports. Receiver: set a port as a receiver port if it is a subscriber port and should only receive multicast data. It does not receive data unless it becomes a mem...

  • Page 176

    Xs26gs managed optical ethernet switch user manual 171 syntax mvlanid vlan-id view system view parameters vlan-id: a vlan id in the range of 2 to 4094. Description use mvr mvlanid to set the multicast vlan id to transmit data and igmp-snooping packets. Examples xs# mvr mvlanid 200 multicast vlan id ...

  • Page 177

    Xs26gs managed optical ethernet switch user manual 172 parameters none description display all multicast ip address groups. Examples xs# show mvr group vlan id : 200 multicast group : 225.1.1.2 vlan id : 200 multicast group : 226.1.1.2 show mvr port syntax show mvr port view any view parameters none...

  • Page 178

    Xs26gs managed optical ethernet switch user manual 173 system view loopback-detection interval-time no loopback-detection interval-time ethernet port view loopback-detection control no loopback-detection control any view show loopback-detection loopback-detection syntax loopback-detection no loopbac...

  • Page 179

    Xs26gs managed optical ethernet switch user manual 174 set successfully loopback-detection control syntax loopback-detection control no loopback-detection control view ethernet port view parameters none description use the loopback-detection control command to enable loopback-detection control on a ...

  • Page 180

    Xs26gs managed optical ethernet switch user manual 175 ethernet0/4 disabled disabled ethernet0/5 disabled disabled ethernet0/6 disabled disabled ethernet0/7 disabled disabled ethernet0/8 disabled disabled ethernet0/9 disabled disabled ethernet0/10 disabled disabled ethernet0/11 disabled disabled eth...

  • Page 181

    Xs26gs managed optical ethernet switch user manual 176 4. Ordering information work in prograes port configuration: s: sfp on all ports type of trnsceiver: 1: dual single-mode fiber sfp module, single wavelength 2: dual multimode fiber sfp module, single wavelength operating distance: 1: 275/550m (f...

  • Page 189

    Xs26gs managed optical ethernet switch user manual 184 6. Appendix b: supported mibs this appendix lists the supported management information base (mibs) for this release of the xs26gs switch. Mib list rfc1213-mib rfc1493-bridge-mib rfc1573-if-mib rfc1643-etherlike-mib rfc1757-rmon-mib rfc2618-radiu...