Z-Wave TSM02 Instruction Manual - page 8

Manual is about: Slim Multi-Sensor

Summary of TSM02

  • Page 1

    Slim multi-sensor tsm02 the slim multi-sensor tsm02 has pir, door/window, temperature and illumination, 4 sensors function in one, based on z-wave tm technology. Z-wave tm is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential ...

  • Page 2

    Association 1. Have z-wave tm controller entered association mode. 2. Pressing tamper key three times within 1.5 seconds will enter association mode. Note: the device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, illumination etc. The group 2 i...

  • Page 3

    Nodes in the group 1. The device will measure the temperature in every 64 seconds. And if the temperature is over 140 degree fahrenheit (60 degree celsius), the device also report in each measurement. * illumination report: when the pir motion detected or the door/window state changed, the device wi...

  • Page 4

    There are three modes “test”, “home automation” and “security”. “test mode” is for the user test the sensor function when installation. “home automation mode” focus in automatic to control the lighting equipment. For convenience and save energy. “security mode” focus in surveillance, warning. When t...

  • Page 5

    5.

  • Page 6

    Battery installation when the device report the low battery message. The user should replace the battery to new one. The way to open the front cover please follow below steps. 1. Using a tool like (1) to press 1-1 till hear a click sound 2. Hold the front cover and pull back 3. Hold the front cover ...

  • Page 7

    Installation 1. In the first time, add the device into the z-wave tm network. First, make sure the primary controller is in the inclusion mode. And then power on the device, just take out the insulation mylar in the back side of the device. The device will auto start the nwi (network wide inclusion)...

  • Page 8

    0 means disable the pir motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. 4 light threshold 99 0~100 setting the illumination threshold t...

  • Page 9

    Time. 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds). Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy. Notice: if this value bigger than the configuration setting no. 9. There is a period after the ...

  • Page 10

    Limited warranty tkb control system limited product is warranted against defects in material and workmanship for two years. Tkb control system limited will replace it free of charge and does not issue any refunds. This this warranty does not apply to: (a) damage to units caused by accident, dropping...