10 Bar 220ex User Manual - 2. Specifications

Manual is about: Camera Housing

Summary of 220ex

  • Page 1

    1 camera housing – model 220ex (canon) user manual contents: 1. Introduction 2. Specifications 3. Function controls 4. Set up instructions 5. Use & care of housing 6. Service 7. Warranty 1. Introduction 10bar underwater housings are small, light and rugged enough to be used on every dive. Use of a c...

  • Page 2: 2. Specifications

    2 2. Specifications test pressure 10 bar (300 ft.) housings are individually tested closure design latch with lock body material polycarbonate overall size 100 x 106 x 142 mm (dxwxh) total weight approximately 0.36 kg (housing only) buoyancy (with flashlight) approximately neutral in salt water feat...

  • Page 3: 4.  Set Up Instructions

    3 4. Set up instructions 4.1 release the latch with lock: push the lock lever forward and left up the lid of the latch (fig.3) (fig.4) 4.2 release the latch (fig.5) 4.3 remove the cover:.

  • Page 4

    4 reposition until the latch is pushing against the hook and lift the lid to push open the back cover 4.3 special note on responsibility for watertight integrity: each housing is individually inspected and hydrostatically tested in the factory. The design of the main piston o-ring seal is among the ...

  • Page 5

    5 procedure: place the lid on a firm non-slip level surface. The o-ring can be extracted using an o-ring extractor tool (make sure the tool as no sharp edges). Alternatively use the flats of the thumbs to gently stretch the o-ring on two faces (fig. 4) thus making a small loop protruding a few mm. T...

  • Page 6

    6 (fig. 7) (fig. 8) replace the lid, remember to ensure the pressure release plug is pulled all the way out while closing, otherwise the air cannot escape. Squeeze the lid closed all the way, you will hear the hiss of air being expelled. (fig. 9) after replacing the lid, make a final visual inspecti...

  • Page 7

    7 5. Use & care of housing 5.1 pre dive function check. Just before entering the water, make a habit of reviewing that you have carried out the proper steps to close the housing and the bulkhead is connected. Make a visual check of the o-ring seal. It is also useful to switch on the camera, and chec...

  • Page 8: 6. Service

    8 exposed to the following classes of chemicals:benzene, toluene, xylene, chlorinated hydrocarbons, methanol, any other solvents, strong acids and bases. For long term storage please remove the main o-ring from body. 5.4 transportation. When transporting by air, please ensure the housing is not seal...

  • Page 9

    9 housing type : date of purchase: serial number : (labelled inside housing) dealer : owner’s name : e-mail : owner’s address: tel : fax : office & showroom: unit c, 2/f., wing hin factory building, 31-33 ng fong st., san po kong, hong kong. Tel: (852) 2573 3228 fax: (852) 2811 9180 email: service@1...