2in1 MICRO User Manual

Summary of MICRO

  • Page 1

    Eng user’s guide blood glucose monitoring system.

  • Page 2

    Thank you for choosing the 2in1. Micro system. Please read this user’s guide carefully before using to ensure correct use. Please keep this user’s guide for your future reference..

  • Page 3

    4 5 2in1. Micro system combined with a smart phone can be used to measure blood glucose anywhere and anytime. The 2in1. Micro system uses the operation system of your android smartphone and is easy and simple to operate. Automatic coding in the 2in1. Micro meter provides accurate results. The system...

  • Page 4

    6 7 table of contents before starting 7 about 2in1. Micro system 10 name and funtion of the parts 11 cautions 14 installing the application 19 obtaining blood drop 20 about alternate site testing 25 testing your blood glucose 29 control solution testing 39 reviewing results 48 troubleshooting 50 car...

  • Page 5

    Before starting before starting 8 9 indications for use the 2in1. Micro blood glucose monitoring system is intended for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, forearm, upperarm, hand, thigh or calf as an aid in monitoring the...

  • Page 6

    10 11 2in1. Micro system includes: 1. 2in1. Micro meter 2. Carrying case 3. Lancing device 4. 2in1. Blood glucose test strips 5. Lancets documents in your system include this user’s guide and quick guide.If any items are missing, call your local distributor. Smart phone is not included and must be p...

  • Page 7

    Names and functions of the parts names and functions of the parts 12 13 2in1. Test strips lancing device electrodes the end of the test strip is inserted into the test strip port of the meter with the end facing up. * clear ast cap is an optional accessory. Please contact your local distributor. Sam...

  • Page 8

    Cautions 14 15 cautions cautions for system • the 2in1. Micro blood glucose monitoring system is intended for use outside the body (in vitro diagnostic use only). • the 2in1. Micro system should be used only for testing glucose and only with fresh capillary whole blood samples. • the 2in1. Micro sys...

  • Page 9

    Cautions cautions 16 17 cautions for test strip • store the test strip in a cool, dry place between 2° and 32°c (36° and 90°f). • keep away from direct sunlight and heat. • after removing test strip from the vial, immediately close the vial cap tightly. • you may get the inaccurate result if vial ca...

  • Page 10

    19 cautions 18 • avoid the meter being exposed to high temperature, high humidity, rain and/or dust when using or storing the meter. • if your meter has been exposed to extremes in temperature, do not test until you have kept the unit at room temperature for at least 20 minutes. The 2in1. Micro syst...

  • Page 11

    Obtaining blood drop 20 21 obtaining blood drop step 1 wash your hands carefully with warm water to increase the circulation of the blood into the fingers. Dry hands thoroughly until the finger to be pricked is completely dry. Step 3 while holding the lancet carrier, insert a new sterile lancet into...

  • Page 12

    Obtaining blood drop obtaining blood drop 22 23 step 5 put the cap of the lancing device back on and turn it clockwise. Step 7 set the proper depth of penetration by rotating the cap of lancing device. 1-2 for soft or thin skin, 3 for average skin, 4-5 for thick or calloused skin. Step 8 place the l...

  • Page 13

    25 obtaining blood drop 24 to reduce the chance of infection: • make sure to wash the puncture site with soap and water before sampling. • do not share a lancet or a lancing device with anyone. • always use a new lancet - lancets are for single use only. • keep your meter and lancing device clean. C...

  • Page 14

    About alternate site testing about alternate site testing 26 27 do not test on alternate sites: • when you think your blood glucose level is changing rapidly, such as within two hours of exercise, a rapidacting insulin injection or insulin pump bolus or within two hours after a meal. • if you are te...

  • Page 15

    29 about alternate site testing 28 place the lancing device on the skin in the chosen site, press and hold the lancing device continuously for a few seconds, then push the release button to take a sample. Watch through the clear cap until a sufficient blood sample is taken. If there is not enough bl...

  • Page 16

    Testing your blood glucose testing your blood glucose 30 31 step 2 plug the 2in1. Micro meter into the usb jack of your smart phone. The white light will turn on showing the meter and “insert strip” message and picture will appear on the display. Step 3 hold the test strip with electrode end facing ...

  • Page 17

    Testing your blood glucose testing your blood glucose 32 33 step 4 “apply sample” will appear letting you know the meter is ready to test. To mark the result as a control solution result, slide the button at the bottom of the screen. Step 5 bring tip of the test strip to lightly touch the drop of bl...

  • Page 18

    Testing your blood glucose testing your blood glucose 34 35 the volume of blood sample must beat least 0.5 microliter (real size ” . “). Important step 6 the application will now show counting progress during 5 seconds. Step 7 your blood glucose test result is shown on the display screen and automat...

  • Page 19

    Testing your blood glucose testing your blood glucose 36 37 • if your test is above 600 mg/ dl (33.3 mmol/l), “high” will appear on the display screen. • if your test result is lower than 10 mg/dl (0.6 mmol/l), “low” will appearon the display screen. Used test strips and lancets maybe considered bio...

  • Page 20

    39 testing your blood glucose 38 range of expected results blood glucose levels will vary dependingon food intake, medication dosages, health, stress or exercise. Consult your healthcare professional for the target value that is appropriate for you. Expected blood glucose levels for people without d...

  • Page 21

    Control solution testing control solution testing 40 41 step 1 tap the 2in1. Micro icon on your smart phone to open the application. If the 2in1. Micro application is not installed, install the application (see page 19). Step 2 plug the 2in1. Micro meter into the usb jack of your smart phone. The wh...

  • Page 22

    Control solution testing control solution testing 42 43 step 3 hold the test strip with electrode end facing up. Insert the electrode end of the test strip into the meter as far as it will go using gentle pressure. Do not force the test strip into the meter. Step 4 “apply sample” will appear letting...

  • Page 23

    Control solution testing control solution testing 44 45 step 5 shake the control solution vial and remove the cap. Gently touch a drop of control solution to the tip of the test strip. Hold until the counting progress starts. Step 6 the application will now show counting progress during 5 seconds. S...

  • Page 24

    Control solution testing control solution testing 46 47 step 8 compare the result displayed on the screen to the control solution range printed on the test strip vial. A single control solution test that is with range is sufficient to show that your meter and test strips are working as intended. If ...

  • Page 25

    Reviewing results 48 49 reviewing results the test results measured by 2in1. Micro system are stored in the smart phone. You can review your test results whether or not your 2in1. Micro meter is connected to the smart phone. Step 1 when you run the 2in1. Micro application to touch the icon of this a...

  • Page 26

    Troubleshooting 50 51 troubleshooting meter does not enter the test mode after inserting 2in1. Micro meter. Probable cause what to do defective meter. Contact your local distributor. 2in1. Micro meter is inserted incompletely into the smart phone. Insert 2in1. Micro meter again. If same problem happ...

  • Page 27

    Caring for system 52 53 caring for system storing your system store your meter, strips and control solution in your carrying case after each use. Store each item in a cool, dry place below 32°c (90°f), but do not refrigerate. Keep all items away from direct sunlight and heat. Tightly close the cap o...

  • Page 28

    55 caring for system 54 cleaning your meter to clean your meter, wipe the outside with a soft cloth dampened with water and mild detergent. Do not use alcohol or another solvent to clean your meter. Do not get any liquids, dirt, dust, blood, or control solution inside the meter through the test port...

  • Page 29

    57 performance characteristics 56 regression statistics model pg110 (2in1. Micro blood glucose monitoring system) test method electrochemical sensor calibration method plasma sample whole blood, capillary sample size 0.5 μl test time 5 seconds memory no limit result range 10~600mg/dl (0.6~33.3mmol/l...

  • Page 30

    Specifications specifications 58 59 electrical and safety standards the meter has been tested for immunity to electro static discharge as specified in iec 61000-4-2. The meter has been tested for immunity to radio frequency interference at the frequency range and test levels specified in iec 61000-4...

  • Page 31

    Printed in slovenia edition date and last revision date: 2in1. Micro_ed2016_rev01_en vpd, bled, d.O.O. Pot na lisice 4, 4260 bled slovenia, eu tel.:+386 4 574 50 70 fax:+386 4 574 50 71 email:info@vpd.Si web:www.2in1.Si.