    Www.2n.Cz 2n helios ip safety ® emergency ip intercom installation manual version: 2.7.

  • Page 2

    The 2n telekomunikace a.S. Is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes gsm gateways, private branch exchanges (pbx), and door and lift communicators. 2n telekomunikace a.S. Has been ranked among the czech top c...

  • Page 3

    The 2n telekomunikace a.S. Is the holder of the iso 9001:2009 certificate. All development, production and distribution processes of the company are managed by this standard and guarantee a high quality, technical level and professional aspect of all our products..

  • Page 4

    2n telekomunikace a.S., www.2n.Cz 4/65 content: 1. Product overview 1.1 components and associated products 1.2 terms and symbols 2. Description and installation 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 extending module connection 3. Function and use 3.1 configur...

  • Page 5

    2n telekomunikace a.S., www.2n.Cz 5/65 1. Product overview here is what you can find in this section: 1.1 components and associated products 1.2 terms and symbols.

  • Page 6

    2n telekomunikace a.S., www.2n.Cz 6/65 basic features 2n helios ip safety ® is a highly resistant and reliable ip door access intercom provided with a lot of useful above-standard functions. Supporting the sip standard and being compatible with the leading ip pbx and telephone suppliers, can 2n heli...

  • Page 7

    2n telekomunikace a.S., www.2n.Cz 7/65 advantages of use uncompromising antivandal design high coverage level – up to class ip69k variable mounting options (brick/plasterboard flush mounting, surface mounting) sensitive microphone and powerful loudspeaker bidirectional communication – acoustic echo ...

  • Page 8

    2n telekomunikace a.S., www.2n.Cz 8/65 1.1 components and associated products basic units 9152101 part no. 1 button control of two electric locks possibility of connecting additional switch 9152101w part no. 1 button 10 w loudspeaker extra robust version control of two electric locks possibility of ...

  • Page 9

    2n telekomunikace a.S., www.2n.Cz 9/65 9152102w part no. 2 buttons with „info“ and „sos“ labels 10 w loudspeaker extra robust version control of two electric locks 9152101m part no. 1 red emergency button 1 w loudspeaker control of two electric locks possibility of connecting additional switch.

  • Page 10

    2n telekomunikace a.S., www.2n.Cz 10/65 9152101mw part no. 1 red emergency button 10 w loudspeaker extra robust version control of two electric locks possibility of connecting additional switch 2n helios ip safety ® units can wall mounted without requiring any additional accessories. Use the appropr...

  • Page 11

    2n telekomunikace a.S., www.2n.Cz 11/65 mounting accessories 9152000 part no. Mounting frame orange aluminum edge good to cover the of the intercom in flush or plasterboard installation. 9151001 part no. Brick flush mounting box stainless steel dimension: 132 x 223 x 83 mm.

  • Page 12

    2n telekomunikace a.S., www.2n.Cz 12/65 9151002 part no. Plasterboard flush mounting box dimension: 237 x 129 x 70 mm hole: 237 x 118 mm internal units part numbers: 91378365 91378365 2n indoor touch ® - black wifi version (second part no.) the elegant internal touch panel, , is suitable 2n indoor t...

  • Page 13

    2n telekomunikace a.S., www.2n.Cz 13/65 voip telephones 91378357 part no. Grandstream gxv3240 voip video telephone gxv3240 is the successor to the popular gxv3140 model, which allows comfortable video calls in the ip network. Touchscreen and keyboard control. 91378358 part no. Grandstream gxv3275 vo...

  • Page 14

    2n telekomunikace a.S., www.2n.Cz 14/65 electric locks 932071e part no. Befo 11211 12v/230ma dc low consumption 932081e part no. Befo 11221 with momentum pin 12v/230ma dc low consumption for opening of the lock a short electrical impuls is sufficient, which unlocks the lock. Lock is then open until ...

  • Page 15

    2n telekomunikace a.S., www.2n.Cz 15/65 part no. 932061e 211211 door signalling, low consumption 12v / 230ma a regular lock with a built-in contact to indicate whether the door is open or closed. Part no. 932072e 31211 fail-safe 12v / 170ma dc the failsafe lock is closed when electricity is switched...

  • Page 16

    2n telekomunikace a.S., www.2n.Cz 16/65 power supply part numbers: 91378100 91378100e 91378100us poe injector - without cable poe injetor - with eu cable poe injector - with us cable for power supply of intercom via ethernet cable when poe switch is not available. 91341481e part no. Stabilised 12 v ...

  • Page 17

    2n telekomunikace a.S., www.2n.Cz 17/65 additional modules 9151010 part no. Additional switch with normally open/closed contact and 12 v switched output. Enables control of a secondary device, passive time unlimited switching up to 48 v / 2 a or active switch 12 v / 700 ma. Also includes tamper swit...

  • Page 18

    2n telekomunikace a.S., www.2n.Cz 18/65 part no. 9159013 exit button (suitable for security relay) a button for connection to a logic input for opening a door inside a building. Part no. 9159014eu/us/uk 2n® 2wire (set of 2 adaptors and power source for eu/us/uk) the converter allows you to use exist...

  • Page 19

    2n telekomunikace a.S., www.2n.Cz 19/65 part no. 9159052 stabilised 12 v / 2 a power supply needs to be used when no poe is available. Part no. 9159051 2n induction loop - external antenna ® external antenna boosts the range of usability of the induction loop, so that the disabled user can receive t...

  • Page 20

    2n telekomunikace a.S., www.2n.Cz 20/65 1.2 terms and symbols the following symbols and pictograms are used in the manual: safety always abide by this information to prevent persons from injury. Warning always abide by this information to prevent damage to the device. Caution important information f...

  • Page 21

    2n telekomunikace a.S., www.2n.Cz 21/65 2. Description and installation here is what you can find in this section: 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 extending module connection.

  • Page 22

    2n telekomunikace a.S., www.2n.Cz 22/65 product completeness check before you start please check the contents of your delivery: 2n helios ip safety ® 1× 2n helios ip safety ® 1× torx 10 / torx 20 double-ended wrench 1× spare sealing for big bushing for a thick cable, one hole 1× big blank with nut 1...

  • Page 23

    2n telekomunikace a.S., www.2n.Cz 23/65 2.2 mechanical installation content common mounting principles flush mounting - classic bricks flush mounting - thermally insulated wall flush mounting - hollow bricks flush mounting - plasterboard wall mounting use of cable bushings common mounting principles...

  • Page 24

    2n telekomunikace a.S., www.2n.Cz 24/65 caution make sure that the dowel holes have the required diameter. If the diameter is too large, the dowels may get loose. Use some suitable building adhesive to keep the dowels in place. Make sure that the hole depth is sufficient too! The dowel length is 50 ...

  • Page 25

    2n telekomunikace a.S., www.2n.Cz 25/65 1. 2. 3. Warning be sure keep strictly the hole dimensions while mounting the device into classic bricks without the flush mounting box as shown in the picture with dimensions. Flush mounting – classic bricks what you need: a precisely cut hole or, optionally,...

  • Page 26

    2n telekomunikace a.S., www.2n.Cz 26/65 4. 5. 6. 7. 8. 9. 10. Remove the front panel from the intercom. Select the holes for cable supply. Insert the blanks into the other holes. Apply the cable bushings or a suitable sealant to prevent penetration of insects or water. You can also insert the small ...

  • Page 27

    2n telekomunikace a.S., www.2n.Cz 27/65.

  • Page 28

    2n telekomunikace a.S., www.2n.Cz 28/65 flush mounting – thermally insulated wall what you need: longer screws (depending on the thermal insulation thickness) hole: (112 × 220 × 70) mm cut out the thermal insulation layer using the template (the same as for classic brick wall)..

  • Page 29

    2n telekomunikace a.S., www.2n.Cz 29/65 caution the hole depth depends on the insulation layer thickness. If the insulation layer is rather thick, you may need longer screws! If there are hollow bricks under the insulation, make sure that your screws pass through the whole dowel (50 mm) and fix the ...

  • Page 30

    2n telekomunikace a.S., www.2n.Cz 30/65 flush mounting – plasterboard what you need: plasterboard flush mounting box, part no. 9151002 hole: (118 × 237) mm use the plasterboard flush mounting box and follow the instructions included therein. Wall mounting what you need: just your unit 2n ® helios ip...

  • Page 31

    2n telekomunikace a.S., www.2n.Cz 31/65 1. 2. 3. 4. 5. 6. Wall (surface) mounting is used where flush mounting is inapplicable (in concrete and steel structures, entry barrier columns, etc.). The frame is not used. Caution wall mounting may be a problem where vandals may destroy the unit (in public ...

  • Page 32

    2n telekomunikace a.S., www.2n.Cz 32/65 use of cable bushings the cable bushings included in the delivery are designed for the 2n ® helios ip safety following cables: big bushing: for two cables of the diameter of 5–6 mm (utp cable), or, upon insert replacement, for one thick cable/tube of the diame...

  • Page 33

    2n telekomunikace a.S., www.2n.Cz 33/65 tip even a lan cable including the rj-45 connector can go through the big bushing. See below for instructions. How to pull a rj-45 terminated cable through a bushing 1. Unscrew the big bushing nut completely. 2. Remove the sealing including the cover from the ...

  • Page 34

    2n telekomunikace a.S., www.2n.Cz 34/65 5. Pull the cable connector though the bushing body into the intercom and clip it into the motherboard connector. 6. Move the sealing including the cover along the cable as far as the bushing body, or add a plug if necessary. 7. Replace and tighten the nut..

  • Page 35

    2n telekomunikace a.S., www.2n.Cz 35/65 2.3 electric installation this subsection describes how to connect into your local area 2n helios ip safety ® network (lan) and how to connect supply voltage and the electric lock. Pcb connectors lan connection external power supply connection electric lock co...

  • Page 36

    2n telekomunikace a.S., www.2n.Cz 36/65 2n helios ip safety ® connectors, pcb version 555v2.

  • Page 37

    2n telekomunikace a.S., www.2n.Cz 37/65 2n helios ip safety ® connectors, pcb version 555v3 description of connectors: x1 – loudspeaker x4 – camera module x5 – button 1 sw1 – reset button (555v3 version only) x6 – configuration jumpers x8 – extending module (rfid card reader or additional switch) x1...

  • Page 38

    2n telekomunikace a.S., www.2n.Cz 38/65 x15 – left-hand microphone x16 – right-hand microphone x17 – relay no and nc contact x18 – 12 v / 700 ma switched output x19 – 12 v / 1 a dc power input led1/2 – system status indicators led3 – lan connection activity indicator lan connection 2n helios ip safe...

  • Page 39

    2n telekomunikace a.S., www.2n.Cz 39/65 1. 2. 3. 4. 5. 6. Electric lock connection 2n helios ip safety ® is equipped with an electrically isolated relay switch with no and nc contacts (terminal block x17) and 12 v / 700 ma switched output (terminal block x18), to which a standard electric lock or an...

  • Page 40

    2n telekomunikace a.S., www.2n.Cz 40/65 configuration jumpers x6, pcb version 555v2: normal operation default setup grounding we recommend to ground the intercom in order to improve the static electricity resistance. For proper grounding you need a cable of the minimum cross-section of 4 mm2. Connec...

  • Page 41

    2n telekomunikace a.S., www.2n.Cz 41/65 1. 2. Mounting completion having connected all the wires, make sure that the bushings, if used, are tightened properly and the rj-45 connector is inserted in the pcb connector. Replace the front cover carefully. Make sure that the connector is inserted correct...

  • Page 42

    2n telekomunikace a.S., www.2n.Cz 42/65 warning when you connect a device containing a coil, such as a relay or an electromagnetic lock, it is necessary to protect the intercom against voltage peak while switching off the induction load. For this way of protection we recommend a diode 1a / 1000v (e....

  • Page 43

    2n telekomunikace a.S., www.2n.Cz 43/65 2.4 extending module connection 2n helios ip safety ® allows to connect following extending modules: additional switch security relay induction loop additional switch the (part no. 9151010) is used for extending the number of outputs. Additional switch this ex...

  • Page 44

    2n telekomunikace a.S., www.2n.Cz 44/65 1. 2. 3. 4. 5. 6. 7. Module mounting: switch off the intercom. Remove the front panel from the intercom. Do not disconnect the button cable! Screw the enclosed 12 mm spacer (5) into the right-hand bottom slot on the main board. Mount the enclosed plastic suppo...

  • Page 45

    2n telekomunikace a.S., www.2n.Cz 45/65 module settings: refer to the for details. Configuration manual connection: security relay the (part no. 9159010) is used for enhancing security between the security relay intercom and the connected electric lock. The is designed 2n helios ip security relay ® ...

  • Page 46

    2n telekomunikace a.S., www.2n.Cz 46/65 specifications: passive switch: no and nc contacts, up to 30 v / 1 a ac/dc active switch output: 9 to 12 v / 700 ma transistor switched output. Depends on power supply (poe: 9 v or power supply voltage minus 1 v). Dimensions: 56 x 31 x 24 mm weight: 20 g insta...

  • Page 47

    2n telekomunikace a.S., www.2n.Cz 47/65 configuration: connect the to the properly set intercom switch 2n helios ip security relay ® output; refer to the . Make sure that one led at least on the configuration manual is on or blinking. 2n helios ip security relay ® press and hold the reset button for...

  • Page 48

    2n telekomunikace a.S., www.2n.Cz 48/65 tip faq: 2n helios ip security relay – what it is and how to use it with 2n ® helios ip intercom? Tip video tutorial: door intercoms 2n helios ip - security relay ® connection: induction loop 2n induction loop ® (part no. 9159050 – induction loop amplifier for...

  • Page 49

    2n telekomunikace a.S., www.2n.Cz 49/65 installation: the induction loop amplifier can be wall mounted with the use of an internal induction loop where a signal covering is requested. Outdoor use is possible thanks to the ip65 covering. A four-wire cable of the length of one meter is mounted to the ...

  • Page 50

    2n telekomunikace a.S., www.2n.Cz 50/65 specifications: supply voltage: 8 – 18vdc supply current at 12 v supply: 1 Ω load, full power output;1.4 a, sine wave signal; 1 a, pink noise signal 8 Ω load, half power output; 550 ma, sine wave signal; 400 ma, pink noise signal no signal; 100 ma standby; up ...

  • Page 51

    2n telekomunikace a.S., www.2n.Cz 51/65 3. Function and use in this section we describe the basic and extending functions of the 2n helios ip ® product. Safety here is what you can find in this section: 3.1 configuration 3.2 maintenance 3.3 downloads.

  • Page 52

    2n telekomunikace a.S., www.2n.Cz 52/65 3.1 configuration use a pc equipped with any web browser to configure : 2n helios ip safety ® launch your web browser (internet explorer, firefox, etc.). Enter the ip address of your intercom ( , e.G.). Http://192.168.1.100/ log in using the user name and pass...

  • Page 53

    2n telekomunikace a.S., www.2n.Cz 53/65 note be sure to press the button sequence within thirty seconds after the sound signal for security reasons. Up to 2 s intervals are allowed between the presses. Switching between static and dynamic ip address connect to the power supply (or, disconnect and re...

  • Page 54

    2n telekomunikace a.S., www.2n.Cz 54/65 caution the 15 times 1 sequence must be entered within 30 seconds after the first sound signal for security reasons. The inter-digit delay may be 2 s at most. The static ip address mode will be switched into the dynamic ip address mode and vice versa upon rest...

  • Page 55

    2n telekomunikace a.S., www.2n.Cz 55/65 3.2 maintenance cleaning if used frequenly, the device surface gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to follow these principles while cleaning: never use aggressive detergents (such as abrasives or stro...

  • Page 56

    2n telekomunikace a.S., www.2n.Cz 56/65 software 2n helios ip network scanner 3.0.4 ®.

  • Page 57

    2n telekomunikace a.S., www.2n.Cz 57/65 4. Technical parameters signalling protocol sip (udp, tcp, tls) buttons button design: industrial waterproof, stainless steel, vandal resistant pushbutton, blue backlit count of buttons: 1 (2 on request) numerical keypad: (on request) audio microphone: 2 integ...

  • Page 58

    2n telekomunikace a.S., www.2n.Cz 58/65 interface power supply: 12 v ±15 % / 2 a dc or poe poe: poe 802.3af (class 0 – 12.95 w) lan: 10/100base-tx s auto-mdix, rj-45 recommended cabling: cat-5e or higher passive switch: no and nc contacts, up to 30 v / 1 a ac/dc active switch output: 9 up to 13 v dc...

  • Page 59

    2n telekomunikace a.S., www.2n.Cz 59/65 5. Supplementary information here is what you can find in this section: 5.1 troubleshooting 5.2 directives, laws and regulations 5.3 general instructions and cautions.

  • Page 60

    2n telekomunikace a.S., www.2n.Cz 60/65 5.1 troubleshooting for the most frequently asked questions refer to . Faq.2n.Cz.

  • Page 61

    2n telekomunikace a.S., www.2n.Cz 61/65 5.2 directives, laws and regulations europe 2n helios ip safety ® conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 - on radio equipment and telecommunications terminal equi...

  • Page 62

    2n telekomunikace a.S., www.2n.Cz 62/65 this equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in...

  • Page 63

    2n telekomunikace a.S., www.2n.Cz 63/65 5.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result...

  • Page 64

    2n telekomunikace a.S., www.2n.Cz 64/65 the consumer shall, without delay, change the access password for the product after installation. The manufacturer shall not be held liable or responsible for any damage incurred by the consumer in connection with the use of the original password. The manufact...

  • Page 65

    2n telekomunikace a.S., www.2n.Cz 65/65 2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic phone: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz v2.7.