    ® 2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide for the corebuilder ™ 9000 enterprise switch interface modules description the 1000base-sx and 1000base-lx gigabit ethernet (gen) interface modules are 2-port interface modules for the corebuilder ™ 9000...

  • Page 2

    2 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide as shown in figure 1, gen interface modules are available in two models: ■ 1000base-lx (order number 3cb9lg2sc). Ports on this module use a 1300-nanometer, multimode/single-mode, optical transce...

  • Page 3

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 3 audience description this guide is intended for trained technical personnel only. Do not attempt to install, remove, or replace a corebuilder 9000 gen interface module if you have not had the proper trai...

  • Page 4

    4 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide esd safety information electrostatic discharge (esd) can damage components of the module. Esd, which occurs when a gen interface module is improperly handled, can cause complete or intermittent ...

  • Page 5

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 5 if the listed contents are not in the shipping box, contact your supplier. All shipping boxes are reusable. After you remove the contents, replace the packing materials in the box and store it for future...

  • Page 6

    6 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide order of installation activities 3com recommends that you install corebuilder 9000 modules in the following order: 1 management modules one enterprise management engine (eme) is required (order ...

  • Page 7

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 7 module placement in the chassis note the following chassis slot restrictions and recommendations when you choose a chassis slot for a gen interface module. In the corebuilder 9000 7-slot chassis: ■ do no...

  • Page 8

    8 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide table 1 mapping the gen sfm* and the 2-port gen interface module to the 7-slot chassis * sfm = switch fabric module chassis slot number number of sfm backplane ports allocated to slot 2-port gen...

  • Page 9

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 9 table 2 mapping the gen sfm* and the 2-port gen interface module to the 16-slot chassis * sfm = switch fabric module chassis slot number number of sfm backplane ports allocated to slot 2-port gen interfa...

  • Page 10

    10 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide installing the gen interface module follow this procedure to install a gen interface module: 1 before you start the installation process, read “safety precautions” and “handling precautions” ea...

  • Page 11

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 11 figure 2 installing the gen interface module in the 7-slot chassis r 3cb9fg24 pri mod st at sec 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3cb9fg24 pri mod st at sec 1 2 3 4 5 6 7 8 ...

  • Page 12

    12 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide figure 3 installing the gen interface module in the 16-slot chassis 1 2 3 4 5 6 7 8 12 13 16 9 10 11 14 15 r corebuilder 9000 3cb9fg24 pri mod st at sec 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1...

  • Page 13

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 13 7 to engage the module connectors and the chassis backplane connectors, apply forward pressure to the module front panel. You feel a slight resistance as the connectors engage. Caution: if the resistanc...

  • Page 14

    14 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide verifying module operation the gen interface modules each have one module status led and two port status leds. Watch the leds during system power-on to verify proper module operation. During th...

  • Page 15

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 15 managing the module you configure and manage the front panel ports on the gen interface module using the administration console, which is a command line interface that you access from a terminal that is...

  • Page 16

    16 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide specifications the following tables list specifications for the gen interface modules: 1000base-sx (3cb9lg2mc) module cabling requirements 1000base-lx (3cb9lg2sc) module cabling requirements du...

  • Page 17

    2-port 1000base-sx and 2-port 1000base-lx gigabit ethernet interface modules quick start guide 17 environmental requirements physical specifications power specifications regulatory compliance operating temperature 0 to 50 ° c (32 to 122 ° f) operating humidity 10% to 90% relative humidity, nonconden...

  • Page 18

    18 2-p ort 1000base-sx and 2-p ort 1000base-lx g igabit e thernet i nterface m odules q uick s tart g uide related corebuilder 9000 documents for detailed information about using and managing gen interface modules, see the following documents: ■ corebuilder 9000 implementation guide ■ command refere...

  • Page 21

    3com corporation l imited w arranty the duration of the warranty for the corebuilder™ 9000 1000base-sx (3cb9lg2mc) and 1000base-lx (3cb9lg2sc) gigabit ethernet interface modules is 1 year. H ardware 3com warrants its hardware products to be free from defects in workmanship and materials, under norma...

  • Page 22

    O btaining w arranty s ervice customer must contact 3com’s corporate service center or an authorized 3com service center within the applicable warranty period to obtain warranty service authorization. Dated proof of purchase may be required. Products returned to 3com’s corporate service center must ...

  • Page 23

    E missions c ompliance s tatements for c lass a p roducts federal communications commission notice this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against...

  • Page 24

    G eneral a pproval s tatement for uk uk general approval statement this equipment is manufactured to the international safety standard en60950 and is approved in the uk under the general approval number ns/g/12345/j/100003 for indirect connection to the public telecommunication network. A ustralian ...