3Com 3C16075 Installation Manual

Manual is about: SUPERSTACK 3 ADVANCED RPS TYPE 3 POWER MODULE

Summary of 3C16075

  • Page 1

    S uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide caution: all installed type 3 power modules must have a dc cable or a protective cover fitted on completion of installation. The type 3 power module is a ul listed accessory for use only with the ul listed advanced...

  • Page 2: Introduction

    2 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide introduction the type 3 power module fits into the superstack 3 advanced rps chassis (3c16071, 3c16071a, or 3c16071b). The module provides redundant power from the advanced rps chassis to the superstack 3 switch ...

  • Page 3

    Superstack 3 advanced rps chassis loading limitations 3 superstack 3 advanced rps chassis loading limitations warning: do not overload the chassis — refer to table 1 “maximum number of advanced rps power modules per chassis” to determine loading limitations. It is important that the loading limitati...

  • Page 4

    4 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide figure 1 shows the rear view of an advanced rps chassis and the power module slot numbers to help you determine which slots to use for your type 3 modules to meet the permitted configurations detailed in table 1....

  • Page 5

    Superstack 3 advanced rps chassis loading limitations 5 table 1 maximum number of advanced rps power modules per chassis configuration type 1 60 w module (3c16072) type 1 100 w module (3c16073), type 2 (100 w) module (3c16074), or type 2a (100 w) module (3c16074a) type 3 module (325 w) (3c16075) a 8...

  • Page 6: Safety Information

    6 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide safety information you must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the superstack 3 advanced rps. Warning: warnings c...

  • Page 7

    Safety information 7 ■ when you connect dc cables to a type 3 power module you must tighten the screws on all dc cable connectors with a suitable tool. ■ when connecting a dc cable to the power module, you must take off the d-type connector protective cover by removing the fixings with a suitable to...

  • Page 8

    8 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide caution: un défaut fugitif d’alimentation peut exister au niveau du connector su power module de type 3 lorsque ce module est dans le chassis rps avancé. Wichtige sicherheitsinformationen der ein- und ausbau der ...

  • Page 9

    Installing the power module 9 caution: wenn sich das type 3 power module im advanced rps chassis befindet kann es zu einer energiegefahr am dc stecker kommen. Installing the power module caution: never plug a hot power module into the advanced rps. You may damage the power module. Allow sufficient t...

  • Page 10: Connecting The Dc Cables

    10 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide connecting the dc cables standard type 3 module dc cable to connect a standard type 3 module dc cable (supplied with this module) to provide redundancy to your superstack 3 unit: 1 ensure the type 3 power module...

  • Page 11: Technical Information

    Technical information 11 caution: do not attempt to use a ‘y’ cable to power two separate superstack 3 units. The equipment may not operate. Caution: all dc cable screws must be tightened with a suitable tool. Technical information troubleshooting if the leds on the superstack 3 advanced rps chassis...

  • Page 12

    12 s uper s tack ® 3 a dvanced rps t ype 3 p ower m odule (3c16075) i nstallation g uide should you be unable to rectify the problem, consult your supplier with the following information: ■ product number and power module serial number ■ brief description of the fault copyright © 2000, 3com technolo...