3Com 3C16981A - SuperStack 3 Switch 3300 User Manual

Manual is about: User Guide

Summary of 3C16981A - SuperStack 3 Switch 3300

  • Page 1

    Http://www.3com.Com/ part no. Dua1698-0aaa06 published september 2000 superstack 3 ® switch 3300 user guide 3c16980a, 3c16981a.

  • Page 2

    3com corporation 5400 bayfront plaza santa clara, california 95052-8145 copyright © 2000, 3com technologies. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) witho...

  • Page 3: Ontents

    C ontents a bout t his g uide conventions 8 related documentation 9 year 2000 compliance 10 documentation comments 10 1 i ntroducing the s witch 3300 about the superstack 3 switch 3300 12 summary of features 12 switch 3300 — front view detail 13 10base-t/ 100base-tx ports 13 leds 13 switch 3300 — re...

  • Page 4

    Iv placing units on top of each other 25 stacking units 26 stacking two units 26 stacking up to four units 27 the power-up sequence 29 connecting a redundant power system 29 powering-up the switch 3300 29 checking for correct operation 29 choosing the correct cables 30 solving problems indicated by ...

  • Page 5: Emc S

    V g lossary i ndex 3c om c orporation l imited w arranty emc s tatements.

  • Page 6

    Vi.

  • Page 7: Bout

    A bout t his g uide this guide provides all the information you need to install and use a superstack ® 3 switch 3300 unit with default settings. If you want to change the way the switch works using management software, refer to the “superstack switch management guide” (part number dua1695-0baa0x). T...

  • Page 8

    8 a bout t his g uide conventions table 1 and table 2 list conventions that are used throughout this guide. Table 1 notice icons icon notice type description information note information that describes important features or instructions caution information that alerts you to potential loss of data o...

  • Page 9

    Related documentation 9 related documentation in addition to this guide, each switch 3300 document set includes the following: ■ management guide (part number dua1695-0baa0x) this guide contains all the management information for the switch. ■ quick reference guide (part number dqa1698-0aaa0x) this ...

  • Page 10

    10 a bout t his g uide in addition, there are other publications you may find useful: ■ documentation accompanying the expansion modules. ■ documentation accompanying the advanced redundant power system. Year 2000 compliance for information on year 2000 compliance and 3com products, visit the 3com y...

  • Page 11: Ntroducing

    1 i ntroducing the s witch 3300 this chapter contains introductory information about the switch and how it can be used in your network. It covers the following topics: ■ about the superstack 3 switch 3300 ■ switch 3300 — front view detail ■ switch 3300 — rear view detail ■ network configuration exam...

  • Page 12

    12 c hapter 1: i ntroducing the s witch 3300 about the superstack 3 switch 3300 the superstack ® 3 switch 3300 connects your existing 10mbps devices, connects high-performance workgroups with a 100mbps backbone or server connection, and connects power users to dedicated 100mbps ports — all in one sw...

  • Page 13

    Switch 3300 — front view detail 13 switch 3300 — front view detail figure 1 switch 3300 — front view 10base-t/ 100base-tx ports the switch has 12 or 24 auto-negotiating 10base-t/100base-tx ports configured as mdix (cross-over). These ports can be set to 10base-t half duplex, 10base-t full duplex, 10...

  • Page 14

    14 c hapter 1: i ntroducing the s witch 3300 table 3 led behavior led color indicates port status leds * * if your switch has 24 10base-t/100base-tx ports, these ports are numbered 1 to 24. If your switch has 12 10base-t/100base-tx ports, these ports are numbered 1 to 12. For both models, ports supp...

  • Page 15

    Switch 3300 — rear view detail 15 switch 3300 — rear view detail figure 2 switch 3300 — rear view unit information label this label shows the following: ■ the 3com product name of the switch ■ the 3com 3c number of the switch ■ the unique mac address (ethernet address) of the switch ■ the serial num...

  • Page 16

    16 c hapter 1: i ntroducing the s witch 3300 console port the console port allows you to connect a terminal and perform remote or local out-of-band management. The console port uses standard null modem cable and is set to auto-baud, 8 data bits, no parity and 1 stop bit. Expansion module slot you ca...

  • Page 17

    Network configuration examples 17 network configuration examples the following illustrations show some examples of how the switch can be used in your network. Switch 3300 as a segmentation switch the example in figure 3 shows how a switch 3300 stack can segment a network of shared 10mbps and 100mbps...

  • Page 18

    18 c hapter 1: i ntroducing the s witch 3300 switch 3300 as a collapsed backbone switch the example in figure 4 shows how a switch 3300 stack can act as a backbone for both shared and switched network segments. Figure 4 using the switch as a collapsed backbone.

  • Page 19

    Network configuration examples 19 switch 3300 as a desktop switch the example in figure 5 shows how a switch 3300 can be used for a group of users that require dedicated 10mbps or 100mbps connections to the desktop. The switch 3300 stack has a superstack 3 switch 1000base-sx module that allows it to...

  • Page 20

    20 c hapter 1: i ntroducing the s witch 3300 configuration rules for fast ethernet the topology rules for 100mbps fast ethernet are slightly different to those for 10mbps ethernet. Figure 6 illustrates the key topology rules and provides examples of how they allow for large-scale fast ethernet netwo...

  • Page 21

    Configuration rules with full duplex 21 the key topology rules are: ■ maximum utp cable length is 100m (328ft) over category 5 cable. ■ a 412m (1352ft) fiber run is allowed for connecting switch-to-switch, or endstation-to-switch, using half-duplex 100base-fx. ■ a total network span of 325m (1066ft)...

  • Page 22

    22 c hapter 1: i ntroducing the s witch 3300

  • Page 23: Nstalling

    2 i nstalling the s witch this chapter contains the information you need to install and set up the switch. It covers the following topics: ■ choosing a suitable site ■ rack-mounting ■ placing units on top of each other ■ stacking units ■ the power-up sequence ■ choosing the correct cables ■ solving ...

  • Page 24

    24 c hapter 2: i nstalling the s witch choosing a suitable site the switch is suited for use in an office environment where it can be mounted in a standard 19-inch equipment rack, or free standing. Alternatively, the switch can be rack-mounted in a wiring closet or equipment room. A rack-mounting ki...

  • Page 25

    Placing units on top of each other 25 figure 7 fitting a bracket for rack mounting 3 insert the three screws and tighten with a suitable screwdriver. You must use the screws supplied with the mounting brackets. Damage caused to the unit by using incorrect screws invalidates your warranty. 4 repeat s...

  • Page 26

    26 c hapter 2: i nstalling the s witch stacking units units in the switch 1100/3300 family can be stacked together and then treated as a single manageable unit with one ip address. You can stack switch units together in two ways: ■ the matrix port on the rear of the switch allows you to connect two ...

  • Page 27

    Stacking units 27 figure 8 a stack of two units stacking up to four units you can stack up to four switch units with a single superstack 3 switch matrix module and the appropriate number of matrix cables. You only need one matrix module for each stack. To stack up to four switch units: 1 power-off a...

  • Page 28

    28 c hapter 2: i nstalling the s witch 5 if you use the management software of the units: ■ ensure that all the units have the same version of management software ■ ensure that you re-configure the stack-wide features on all the units for more information about management software, see “managing the...

  • Page 29

    The power-up sequence 29 the power-up sequence the following sections describe how to get your switch 3300 powered-up and ready for operation. Connecting a redundant power system you can connect a superstack 3 advanced redundant power system (part number 3c16071b) to the switch. This unit, which is ...

  • Page 30

    30 c hapter 2: i nstalling the s witch if there is evidence of a problem, see “solving problems indicated by leds” on page 31 . Choosing the correct cables all of the ports on the front of the switch 3300 are configured as mdix (cross-over). If you want to make a connection to another mdix port, you...

  • Page 31

    Solving problems indicated by leds 31 solving problems indicated by leds if the leds on the switch indicate a problem, refer to table 5 which contains a list of problems and suggested solutions. For information about solving problems when managing the switch, refer to the problem solving chapter in ...

  • Page 32

    32 c hapter 2: i nstalling the s witch managing the switch the switch contains software that allows you to change and monitor the way it works. This management software is not required to get the switch working, but if you do use it, you may improve the efficiency of the switch and therefore improve...

  • Page 33: Afety

    A s afety i nformation you must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the switch 3300. Warning: warnings contain directions that you must follow for your personal safety. Follow all directions carefully. ...

  • Page 34

    34 a ppendix a: s afety i nformation important safety information ■ installation and removal of the unit must be carried out by qualified personnel only. ■ if installing the switch unit in a stack with superstack 3 hub units, the switch 3300 unit must be installed below the narrower hub units. ■ the...

  • Page 35

    Important safety information 35 ■ france and peru only: this unit cannot be powered from it† supplies. If your supplies are of it type, this unit must be powered by 230v (2p+t) via an isolation transformer ratio 1:1, with the secondary connection point labelled neutral, connected directly to earth (...

  • Page 36

    36 a ppendix a: s afety i nformation l’information de sécurité importante ■ l'installation et la dépose de ce groupe doivent être confiés à un personnel qualifié. ■ si vous entassez l'unité switch avec les unités superstack 3 hub, l'unité switch 3300 doit être installée en dessous des unités hub plu...

  • Page 37

    L’information de sécurité importante 37 ■ l’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme cei 950. Ces conditions ne sont maintenues que si l'équipement auquel il est raccordé fonctionne dans les mêmes conditions. ■ france et pérou uniquement: ce groupe ...

  • Page 38

    38 a ppendix a: s afety i nformation wichtige sicherheitsinformat ionen ■ die installation und der ausbau des geräts darf nur durch fachpersonal erfolgen. ■ wenn die switch 3300 einheit in einer stapel mit anderen superstack 3 hub einheiten eingebaut werden soll, muß die switch 3300 einheit unter di...

  • Page 39: Outs

    B p in - outs null modem cable 9-pin to rs-232 25-pin pc-at serial cable 9-pin to 9-pin.

  • Page 40

    40 a ppendix b: p in - outs modem cable 9-pin to rs-232 25-pin rj45 pin assignments pin assignments are identical for 10base-t and 100base-tx rj45 connectors table 6 pin assignments pin number signal function ports configured as mdi 1 txdata + transmit data 2 txdata – transmit data 3 rxdata + receiv...

  • Page 41

    Rj45 pin assignments 41 ports configured as mdix 1 rxdata + receive data 2 rxdata – receive data 3 txdata + transmit data 4 not assigned 5 not assigned 6 txdata – transmit data 7 not assigned 8 not assigned table 6 pin assignments pin number signal function.

  • Page 42

    42 a ppendix b: p in - outs.

  • Page 43: Echnical

    C t echnical s pecifications physical dimensions height: 76mm (3.0 in.) x width: 483mm (19.0 in.) x depth 300mm (12.0 in.) weight: 4kg (8.8lbs) environmental requirements operating temperature 0° to 50°c (32° to 122°f) storage temperature –10° to +70°c (14° to 158°f) operating humidity 10–95% relati...

  • Page 44

    44 a ppendix c: t echnical s pecifications standards supported snmp snmp protocol (rfc 1157) mib-ii (rfc 1213) bridge mib (rfc 1493) repeater mib (rfc 1516) vlan mib (rfc 1573) rmon mib (rfc 1271) bootp (rfc 951) terminal emulation telnet (rfc 854) protocols used for administration udp (rfc 768) ip ...

  • Page 45: Echnical

    D t echnical s upport 3com provides easy access to technical support information through a variety of services. This appendix describes these services. Information contained in this appendix is correct at time of publication. For the most recent information, 3com recommends that you access the 3com ...

  • Page 46

    46 a ppendix d: t echnical s upport to connect to the 3com ftp site, enter the following information into your ftp client: ■ hostname: ftp.3com.Com ■ username: anonymous ■ password: you do not need a user name and password with web browser software such as netscape navigator and internet explorer. S...

  • Page 47

    Support from 3com 47 when you contact 3com for assistance, have the following information ready: ■ product model name, part number, and serial number ■ a list of system hardware and software, including revision levels ■ diagnostic error messages ■ details about recent configuration changes, if appli...

  • Page 48

    48 a ppendix d: t echnical s upport returning products for repair before you send a product directly to 3com for repair, you must first obtain an authorization number. Products sent to 3com without authorization numbers will be returned to the sender unopened, at the sender’s expense. To obtain an a...

  • Page 49: Lossary

    G lossary 10base-t the ieee specification for 10mbps ethernet over category 3, 4 or 5 twisted pair cable. 100base-fx the ieee specification for 100mbps fast ethernet over fiber-optic cable. 100base-tx the ieee specification for 100mbps fast ethernet over category 5 twisted-pair cable. Auto-negotiati...

  • Page 50

    50 g lossary broadcast storm multiple simultaneous broadcasts that typically absorb all the available network bandwidth and can cause a network to fail. Broadcast storms can be due to faulty network devices. Collision a term used to describe two colliding packets in an ethernet network. Collisions a...

  • Page 51

    G lossary 51 hub a device that regenerates lan traffic so that the transmission distance of that signal can be extended. Hubs are similar to repeaters, in that they connect lans of the same type; however they connect more lans than a repeater and are generally more sophisticated. Ieee institute of e...

  • Page 52

    52 g lossary mac address media access control address; also called hardware or physical address. A layer 2 address associated with a particular network device. Most devices that connect to a lan have a mac address assigned to them as they are used to identify other devices in a network. Mac addresse...

  • Page 53

    G lossary 53 snmp simple network management protocol. The current ietf standard protocol for managing devices on an tcp/ip network. Stack a group of network devices that are integrated to form a single logical device. Stp see spanning tree protocol (stp) . Switch a device that interconnects several ...

  • Page 54

    54 g lossary.

  • Page 55: Ndex

    I ndex numbers 10base-t/100base-tx ports 13 3c number 15 3com knowledgebase web services 45 3com url 45 a auto-negotiating ports 13 c cable choosing the correct 30 matrix 16 maximum length 13, 21 pin-outs 39 console port 16 conventions notice icons, about this guide 8 text, about this guide 8 cross-...

  • Page 56

    56 i ndex matrix 16 power socket 15 powering-up a switch 3300 29 product name 15 r rack mounting a switch 3300 24 redundant power system. See rps returning products for repair 48 rps 15 connecting 29 socket 15 s safety information english 34 french 36 german 38 segment, maximum length 13, 21 serial ...

  • Page 57

    3com corporation l imited w arranty thus warranty applies to customers located in the united states, australia, canada (except quebec), ireland, new zealand, uk, and other english language countries for which a translation into the local language is not provided. S uper s tack ® 3 s witch 3300 h ard...

  • Page 58

    Or sent by a method that provides for tracking of the package. Responsibility for loss or damage does not transfer to 3com until the returned item is received by 3com. The repaired or replaced item will be shipped to customer, at 3com's expense, not later than thirty (30) days after 3com receives th...

  • Page 59

    Consequential, indirect, special, or punitive damages of any kind, or for loss of revenue or profits, loss of business, loss of information or data, or other financial loss arising out of or in connection with the sale, installation, maintenance, use, performance, failure, or interruption of its pro...

  • Page 60

    R egulatory n otices fcc s tatement this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a comme...