    Http://www.3com.Com/ part no. Dua1730-0aaa03 published july 2005 superstack ® 3 switch 4200 family getting started guide switch 4200 26-port (3c17300a) switch 4200 50-port (3c17302a) switch 4200 28-port (3c17304a) dua1730-0aaa03.Book page 1 thursday, november 17, 2005 12:17 pm.

  • Page 2

    3com corporation 350 campus drive marlborough, ma 01752-3064 copyright © 2002, 2005 3com corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without writ...

  • Page 3: Ontents

    C ontents a bout t his g uide conventions 8 related documentation 9 accessing online documentation 10 documentation comments 10 1 i ntroducing the s uper s tack 3 s witch 4200 f amily about the switch 4200 family 12 summary of hardware features 12 switch 4200 family — front view detail 13 10base-t/ ...

  • Page 4

    Approved sfp transceivers 25 inserting an sfp transceiver 26 removing an sfp transceiver 27 choosing the correct cables 27 choosing the correct fiber cables 28 3 s etting u p for m anagement setting up overview 32 ip configuration 33 preparing for management 34 manually configuring ip information 35...

  • Page 5

    A s afety i nformation important safety information 58 l’information de sécurité importante 60 wichtige sicherheitsinformationen 62 información de seguridad importante 64 importanti informazioni di sicurezza 66 b p in - outs null modem cable 69 pc-at serial cable 69 modem cable 70 rj-45 pin assignme...

  • Page 6

    Dua1730-0aaa03.Book page 6 thursday, november 17, 2005 12:17 pm.

  • Page 7: Bout

    A bout t his g uide this guide provides all the information you need to install and use a superstack ® 3 switch 4200 in its default state. This guide is intended for use with the following switch 4200 family models: ■ switch 4200 26-port (3c17300a) — 24 10base-t/100base-tx ports, 2 10/100/1000base-t...

  • Page 8

    8 a bout t his g uide most user guides and release notes are available in adobe acrobat reader portable document format (pdf) or html on the 3com world wide web site: http://www.3com.Com/ conventions table 1 and table 2 list conventions that are used throughout this guide. Table 1 notice icons icon ...

  • Page 9

    Related documentation 9 related documentation in addition to this guide, each switch documentation set includes the following: ■ superstack 3 switch implementation guide this guide contains information on the features supported by your switch and how they can be used to optimize your network. It is ...

  • Page 10

    10 a bout t his g uide there are other publications you may find useful, such as: ■ documentation accompanying 3com network supervisor. You can download 3com network supervisor and supporting documentation from the 3com web site at: www.3com.Com/3ns accessing online documentation the cd-rom supplied...

  • Page 11: Ntroducing

    1 i ntroducing the s uper s tack 3 s witch 4200 f amily this chapter contains introductory information about the switch 4200 family and how it can be used in your network. It covers summaries of hardware and software features and also the following topics: ■ about the switch 4200 family ■ switch 420...

  • Page 12

    12 c hapter 1: i ntroducing the s uper s tack 3 s witch 4200 f amily about the switch 4200 family the switch 4200 family are stackable 10/100/1000 mbps devices which consist of: ■ 24 or 48 10base-t/100base-tx ports ■ 2 10/100/1000base-t ports ■ 2 sfp ports (switch 4200 28-port only) the switch provi...

  • Page 13

    About the switch 4200 series 13 switch 4200 family — front view detail figure 1 switch 4200 26-port (3c17300a) — front view figure 2 switch 4200 50-port (3c17302a) — front view figure 3 switch 4200 28-port (3c17304a) — front view 3c17300a superstack 3 switch 4200 26-port 10base-t / 100base-tx rj-45 ...

  • Page 14

    14 c hapter 1: i ntroducing the s uper s tack 3 s witch 4200 f amily warning: rj-45 ports. These are shielded rj-45 data sockets. They cannot be used as standard traditional telephone sockets, or to connect the unit to a traditional pbx or public telephone network. Only connect rj-45 data connectors...

  • Page 15

    About the switch 4200 series 15 negotiated with the link partner. Alternatively, auto-negotiation can be disabled and the flow control setting can be manually configured. Leds table 4 lists leds visible on the front of the switch, and how to read their status according to color. For information on u...

  • Page 16

    16 c hapter 1: i ntroducing the s uper s tack 3 s witch 4200 f amily switch 4200 family — rear view detail figure 4 switch 4200 family — rear view power socket the switch automatically adjusts its power setting to any supply voltage in the range 100-240 vac. Console port the console port allows you ...

  • Page 17

    About the switch 4200 series 17 default settings table 5 shows the default settings for the switch 4200 family: table 5 default settings if you initialize a switch unit by selecting system > control > initialize in the web interface or by entering system control initialize in the command line interf...

  • Page 18

    18 c hapter 1: i ntroducing the s uper s tack 3 s witch 4200 f amily dua1730-0aaa03.Book page 18 thursday, november 17, 2005 12:17 pm.

  • Page 19: Nstalling

    2 i nstalling the s witch this chapter contains the information you need to install and set up the switch 4200 family. It covers the following topics: ■ package contents ■ choosing a suitable site ■ rack-mounting ■ placing units on top of each other ■ the power-up sequence ■ sfp operation ■ choosing...

  • Page 20

    20 c hapter 2: i nstalling the s witch procedura di manutenzione, leggere le informazioni di sicurezza riportate nell'appendice a della presente guida per l'utente. Package contents ■ switch unit ■ cd-rom ■ getting started guide (this guide) ■ release notes ■ unit information labels ■ warranty infor...

  • Page 21

    Rack-mounting 21 if the switch is installed in a 19-inch rack or closed assembly its local air temperature may be greater than room ambient temperature. ■ the air is as free from dust as possible. ■ the switch is situated away from sources of conductive (electrical) dust, for example, laser printers...

  • Page 22

    22 c hapter 2: i nstalling the s witch figure 5 fitting a bracket for rack-mounting 3 insert the two screws and tighten with a suitable screwdriver. You must use the screws supplied with the mounting brackets. Damage caused to the unit by using incorrect screws invalidates your warranty. 4 repeat st...

  • Page 23

    Placing units on top of each other 23 placing units on top of each other if the switch units are free-standing, up to eight units can be placed one on top of the other. If you are mixing a variety of superstack ® 3 switch and hub units, the smaller units must be positioned at the top. If you are pla...

  • Page 24

    24 c hapter 2: i nstalling the s witch stack renumbering occurs when another switch 4200 family unit is added to the bottom of an established stackexceptwhen the stack is already 4 units high. In this instance the ‘down’ port on the bottom unit of the existing stack will be disabled and its led will...

  • Page 25

    Sfp operation 25 when the post has completed, check the power on self test led to make sure that your switch is operating correctly. Table 6 shows possible colors for the led. Table 6 power/self test led colors in addition, check the unit leds on all switches in the stack. If a unit led is off, init...

  • Page 26

    26 c hapter 2: i nstalling the s witch inserting an sfp transceiver to be recognized as valid, the sfp transceiver must have the following characteristics: ■ 1000base-sx sfp transceiver use this transceiver to connect the switch directly to a multimode fiber-optic cable. ■ 1000base-lx sfp transceive...

  • Page 27

    Choosing the correct cables 27 figure 7 inserting an sfp transceiver 6 check the leds on the front of the switch to ensure that it is operating correctly. Refer to “ leds ” on page 16 for more information. Removing an sfp transceiver if you wish to remove a transceiver (it is not necessary to power-...

  • Page 28

    28 c hapter 2: i nstalling the s witch port, you need a cross-over cable. Many ports on workstations and servers are configured as mdi (straight-through). If you want to make a connection to an mdi port, you need to use a standard straight-through cable. See table 7 . 3com recommends that you use ca...

  • Page 29

    Choosing the correct cables 29 if you wish to connect a 1000base-sx lc port to a fiber port with a different type of connector, for example, sc or st please contact your network supplier for a suitable patch cable. Dua1730-0aaa03.Book page 29 thursday, november 17, 2005 12:17 pm.

  • Page 30

    30 c hapter 2: i nstalling the s witch dua1730-0aaa03.Book page 30 thursday, november 17, 2005 12:17 pm.

  • Page 31: Etting

    3 s etting u p for m anagement your switch can operate in its default state, that is, you can install it and it will work straight away (plug-and-play). However, to make full use of the features offered by the switch, and to change and monitor the way it works, you have to access the management soft...

  • Page 32

    32 c hapter 3: s etting u p for m anagement setting up overview this section gives an overview of what you need to do to get your switch set up and ready for management when it is in its default state. The whole setup process is summarised in figure 8 . Detailed procedural steps are contained in the...

  • Page 33

    Setting up overview 33 ip configuration you can use one of the following methods to allocate ip information to your switch (essential if you wish to manage your switch across the network). Manual ip configuration you can choose to configure the ip information yourself. The switch remembers the infor...

  • Page 34

    34 c hapter 3: s etting u p for m anagement however, as soon as a dhcp or bootp server is detected, the switch will configure itself with the ip address allocated by that server. When using automatic ip configuration it is important that the ip address of the switch is static, otherwise you will not...

  • Page 35

    Manually configuring ip information 35 manually configuring ip information you can manually configure the switch ip information in the following ways: ■ connecting to a front panel port — connect a workstation using an ethernet cable to a front panel port of the switch. You can then manually enter i...

  • Page 36

    36 c hapter 3: s etting u p for m anagement connecting the workstation to the switch 1 connect the workstation to a front panel port using an ethernet cable as shown in figure 9 . Figure 9 connecting a workstation to the switch via a front panel port to connect the cable: a attach an rj-45 connector...

  • Page 37

    Manually configuring ip information 37 if there is no response, wait for one minute then re-enter the default ip address. 3 at the login and password prompts, enter admin as your user name and press return at the password prompt (default user name and password). If you have logged on correctly, a se...

  • Page 38

    38 c hapter 3: s etting u p for m anagement top-level menu of the command line interface is displayed as shown in the example in figure 10 . Figure 10 example top-level command line interface menu 4 at the select menu option prompt you can either: ■ enter the protocol ip basicconfig command. At the ...

  • Page 39

    Manually configuring ip information 39 pre-requisites ■ a workstation with terminal emulation software installed, such as microsoft hyperterminal. This software allows you to communicate with the switch via the console port directly, or through a modem. ■ documentation supplied with the terminal emu...

  • Page 40

    40 c hapter 3: s etting u p for m anagement 2 open your terminal emulation software and configure the com port settings to which you have connected the cable. The settings should be set to match the default settings for the switch, which are: ■ 19,200 baud ■ 8 data bits ■ no parity ■ 1 stop bit ■ no...

  • Page 41

    Manually configuring ip information 41 figure 12 example top-level command line interface menu 3 at the select menu option prompt you can either: ■ enter the protocol ip basicconfig command. At the enter configuration method prompt enter manual. The screen prompts you to enter ip information. Or ■ e...

  • Page 42

    42 c hapter 3: s etting u p for m anagement viewing automatically configured ip information if you allow the switch to automatically configure its own ip information you need to discover and view the ip information before you can begin to manage the switch. You can discover the ip information in two...

  • Page 43

    Viewing automatically configured ip information 43 ■ a suitable cable: ■ a standard null modem cable — if you are connecting directly to the console port, or ■ a standard modem cable — if you are connecting to the console port using a modem. You can find pin-out diagrams for both cables in appendix ...

  • Page 44

    44 c hapter 3: s etting u p for m anagement viewing ip information via the console port you are now ready to view the automatically allocated ip information using the command line interface. 1 connect your switch to the network using an ethernet cable. As soon as a network connection is made the swi...

  • Page 45

    Methods of managing a switch 45 prompt enter all. A summary of the automatically allocated ip information is displayed. Make a note of the network ip address. The initial set up of your switch is now complete and the switch is ready for you to set up your chosen management method. See “methods of ma...

  • Page 46

    46 c hapter 3: s etting u p for m anagement figure 15 cli management via the console port figure 16 cli management over the network refer to “setting up command line interface management” on page 47 . Web interface management each switch has an internal set of web pages that allow you to manage the ...

  • Page 47

    Setting up command line interface management 47 figure 18 snmp management over the network refer to “setting up snmp management” on page 49 . Setting up command line interface management this section describes how you can set up command line interface management using a local console port connection...

  • Page 48

    48 c hapter 3: s etting u p for m anagement 4 to open a telnet session via the dos prompt, enter the ip address of the switch that you wish to manage in the following format: >telnet xxx.Xxx.Xxx.Xxx (where xxx.Xxx.Xxx.Xxx is the ip address of the switch) if opening a telnet session via third party s...

  • Page 49

    Setting up snmp management 49 for the browser to operate the web interface correctly, javascript™ and cascading style sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings. Web managemen...

  • Page 50

    50 c hapter 3: s etting u p for m anagement you can use the 3com network supervisor application that is provided on the cd-rom that accompanies your switch to provide snmp management for your switch. If you use 3com network supervisor it automatically loads the correct mibs and necessary files onto ...

  • Page 51

    Default users and passwords 51 changing default passwords you can change the default passwords using either: ■ the gettingstarted command on the cli, or ■ the security device user modify command on the cli, or ■ the security > device > user > modify operation on the web interface. For more informati...

  • Page 52

    52 c hapter 3: s etting u p for m anagement dua1730-0aaa03.Book page 52 thursday, november 17, 2005 12:17 pm.

  • Page 53: Roblem

    4 p roblem s olving this chapter helps you to diagnose and solve problems you may have with the operation of your switch. There is also an explanation of ip addressing. The topics covered are: ■ solving problems indicated by leds ■ solving hardware problems ■ solving communication problems ■ solving...

  • Page 54

    54 c hapter 4: p roblem s olving solving problems indicated by leds if the leds on the switch indicate a problem, refer to the list of suggested solutions below. The power led does not light check that the power cable is firmly connected to the switch and to the supply outlet. If the connection is s...

  • Page 55

    Solving communication problems 55 problem, completely remove the sfp and replace it with a 3com approved sfp. See “approved sfp transceivers” on page 26. Error message indicating that the sfp transceiver is faulty. To correct this problem, completely remove the sfp and then reinsert it.Alternatively...

  • Page 56

    56 c hapter 4: p roblem s olving how do you obtain a registered ip address? The ip registration system ensures that every ip address used is unique; if you do not have a registered ip address, you may be using an identical address to someone else and your network will not operate correctly. Internic...

  • Page 57: Afety

    A s afety i nformation you must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the switch 4200 family. Warning: warnings contain directions that you must follow for your personal safety. Follow all directions care...

  • Page 58

    58 a ppendix a: s afety i nformation important safety information warning: installation and removal of the unit must be carried out by qualified personnel only. Warning: if installing the switch 4200 family unit in a stack with superstack ii or superstack 3 units that are shallower than the 4200 fam...

  • Page 59

    Important safety information 59 warning: the socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet. Warning: this unit operates under selv (safety extra low voltage) conditions according to iec 950. The c...

  • Page 60

    60 a ppendix a: s afety i nformation warning: fiber optic ports - optical safety never look at the transmit laser while it is powered-up. Never look directly at the fiber ports and fiber cable ends when they are powered-up. Warning: use of controls or adjustments of performance or procedures other t...

  • Page 61

    L’information de sécurité importante 61 avertissement: cordon électrique: il doit être agréé ans le pays d'utilisation: avertissement: le coupleur d'appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d'appareil en60...

  • Page 62

    62 a ppendix a: s afety i nformation connexion portant l'appellation neutre et avec raccordement direct à la terre (masse). Avertissement: points d’accès rj-45. Ceux-ci sont protégés par des prises de données. Ils ne peuvent pas être utilisés comme prises de téléphone conventionnelles standard, ni p...

  • Page 63

    Wichtige sicherheitsinformationen 63 vorsicht: das gerät muß an eine geerdete steckdose angeschlossen werden, die europäischen sicherheitsnormen erfüllt. Vorsicht: der anschlußkabelsatz muß mit den bestimmungen des landes übereinstimmen, in dem er verwendet werden soll. Vorsicht: der gerätestecker (...

  • Page 64

    64 a ppendix a: s afety i nformation vorsicht: faseroptikanschlüsse – optische sicherheit niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf die faseransnchlüsse und auf die faserkabelenden schauen, während diese eingeschaltet sind. Vorsicht: die verwendun...

  • Page 65

    Información de seguridad importante 65 advertencia: conjunto de cables eléctricos: debe estar homologado para el país donde se utilice: advertencia: el acoplador del equipo (el conector para la unidad y no la toma de la pared) debe tener una configuración que se adapte a una entrada del equipo en603...

  • Page 66

    66 a ppendix a: s afety i nformation advertencia: sólo para francia y perú: esta unidad no puede recibir corriente de fuentes it†. Si las fuentes de suministro de corriente son de tipo it, esta unidad debe recibir 230 v (2p+t) a través de un transformador aislador con relación 1:1, con el punto de c...

  • Page 67

    Importanti informazioni di sicurezza 67 avvertenza: l'unità deve disporre di messa a terra. Avvertenza:per rispettare gli standard di sicurezza, è necessario collegare l'unità a una fonte di alimentazione dotata di messa a terra. Avvertenza: set dei cavi di alimentazione deve essere approvato per il...

  • Page 68

    68 a ppendix a: s afety i nformation mantenute solo se anche l'apparecchiatura a cui è collegata opera nelle stesse condizioni. Avvertenza: solo per francia e perù. Questa unità non può ricevere alimentazione di tipo it†. Se l'alimentazione è di tipo it, l'unità deve essere alimentata a 230 v (2p+t)...

  • Page 69: Outs

    B p in - outs null modem cable 9-pin to rs-232 25-pin pc-at serial cable 9-pin to 9-pin screen txd rxd ground rts cts dsr dcd dtr screen rxd txd ground rts dtr cts dsr dcd shell 3 2 5 7 8 6 1 4 1 3 2 7 4 20 5 6 8 switch 4200 cable connector: 9-pin female pc/terminal cable connector: 25-pin male/fema...

  • Page 70

    70 a ppendix b: p in - outs modem cable 9-pin to rs-232 25-pin rj-45 pin assignments pin assignments for ports configured as mdi and mdix are given in table 10 and table 11 . Table 10 pin assignments screen txd rxd rts cts dsr ground dcd dtr screen txd rxd rts cts dsr ground dcd dtr shell 3 2 7 8 6 ...

  • Page 71

    Rj-45 pin assignments 71 table 11 pin assignments pin number 10/100 1000 ports configured as mdix 1 receive data + bidirectional data b+ 2 receive data - bidirectional data b- 3 transmit data + bidirectional data a+ 4 not assigned bidirectional data a- 5 not assigned bidirectional data d+ 6 transmit...

  • Page 72

    72 a ppendix b: p in - outs dua1730-0aaa03.Book page 72 thursday, november 17, 2005 12:17 pm.

  • Page 73: Echnical

    C t echnical s pecifications switch 4200 26-port (3c17300a) physical dimensions height: 44 mm (1.7 in.) x width: 440 mm (17.3 in.) x depth: 274 mm (10.8 in.) weight: 2.4 kg (5.3 lbs) environmental requirements operating temperature 0 ° to 40 °c (32 ° to 104 °f) storage temperature –40 ° to +70 °c (-...

  • Page 74

    74 a ppendix c: t echnical s pecifications switch 4200 50-port (3c17302a) physical dimensions height: 44 mm (1.7 in.) x width: 440 mm (17.3 in.) x depth: 274 mm (10.8 in.) weight: 2.83 kg (6.23 lbs) environmental requirements operating temperature 0 ° to 40 °c (32 ° to 104 °f) storage temperature –4...

  • Page 75

    Switch 4200 28-port (3c17304a) 75 switch 4200 28-port (3c17304a) physical dimensions height: 44 mm (1.7 in.) x width: 440 mm (17.3 in.) x depth: 274 mm (10.8 in.) weight: 2.73 kg (6.00 lbs) environmental requirements operating temperature 0 ° to 40 °c (32 ° to 104 °f) storage temperature –40 ° to +7...

  • Page 76

    76 a ppendix c: t echnical s pecifications dua1730-0aaa03.Book page 76 thursday, november 17, 2005 12:17 pm.

  • Page 77: Btaining

    D o btaining s upport for your p roduct register your product warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you. Warranty and other service be...

  • Page 78

    78 a ppendix d: o btaining s upport for your p roduct troubleshoot online you will find support tools posted on the 3com web site at http://www.3com.Com/ 3com knowledgebase helps you troubleshoot 3com products. This query-based interactive tool is located at http://knowledgebase.3com.Com and contain...

  • Page 79

    Contact us 79 to send a product directly to 3com for repair, you must first obtain a return authorization number (rma). Products sent to 3com, without authorization numbers clearly marked on the outside of the package, will be returned to the sender unopened, at the sender’s expense. If your product...

  • Page 80

    80 a ppendix d: o btaining s upport for your p roduct austria belgium denmark finland france germany hungary ireland israel italy 01 7956 7124 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 12813 1407 3387 1800 945 3794 199 161346 luxembourg netherlands norway poland portugal sout...

  • Page 81: Ndex

    I ndex 81 i ndex numbers 10/100/1000base-t ports 14 3c number 22 a access levels of default users 50 automatic setup 42 3com network supervisor 42 console port 42 b browsers choosing 48 c cable choosing the correct 25 fiber 28 maximum length 14 pin-outs 69 cd-rom 10 command line interface management...

  • Page 82

    82 i ndex hardware problems 54 ip addressing 54 leds 54 solving software upgrade problems 56 stack formation problems 56 product name 22 r rack mounting a switch 4200 21 s safety information english 58 french 60 german 62 italian 66 spanish 64 serial number of the switch 22 serial port. See console ...

  • Page 83

    R egulatory n otices fcc s tatement this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a comme...

  • Page 84

    Dua1730-0aaa03.Book page 84 thursday, november 17, 2005 12:17 pm.