3M Chassis C2234PW User Manual - page 7
3M™ Multi-Touch Chassis Display User Guide
7
3M Touch Systems, Inc. Proprietary Information – TSD-37732F
WARNING
To avoid the risk of electric shock which could result in serious injury or death:
•
Do not remove the cover or back of the display. The backlight inverter output is at
high voltage.
•
This device must be operated with the original power supply and cable provided as
shown below:
•
LITEON PA-1081-01 or EDAC EA11001C-120 for the C2254PW
•
LITEON PA-1041-0 or EDAC EA10521E-120 for the C2234PW
•
Do not use a damaged power supply.
•
Plug power cord into appropriate grounded power source.
•
Do not use a power cord that is frayed or otherwise damaged.
To avoid the risk of electric shock which may result in serious injury or death:
•
Do not service the display yourself. There are no user serviceable parts inside. Refer
all servicing to qualified service personnel. Any change or modification to the
equipment not expressly approved by the party responsible for compliance could void
your authority to operate such equipment.
•
Do not use non-conforming replacement parts.
•
Do not place wet or damp objects on the display.
•
Do not expose the display to rain or other sources of water, steam, or moisture.
•
Do not place foreign objects on the display or its cables.
•
Do not remove the cover or back of the display.
•
Ensure that connecting the unit to the power source will not overload the power
source.
CAUTION
To avoid the risk of potential damage to the display electronics:
•
Always use the VESA mounting holes when using an arm attachment. Do not drill
additional holes in the unit to mount plates other locations
•
Do not use longer screws as they could potentially damage electronics inside the
display.
To avoid the risk of glass breakage which may result in minor or moderate injury:
•
To avoid risk of injury the when handling the display be aware that the sensor edges
are very sharp.
•
Handle the display with care to avoid breaking the touch sensor. The display contains
glass parts. Dropping the display may cause the glass parts to break.
•
Ensure mounting screws are tightened fully to prevent instability.
•
Do not place foreign objects on the display.
•
Ensure that mounting the unit will not adversely affect the stability of the end
equipment when installing in free standing equipment or using the VESA mount.