Manifolds may be used with metal or non-metallic piping systems.
1. Shut off incoming cold water supply.
2. Select the installation location.
IMPORTANT NOTE:Allowaminimumof3in(7.6cm)ofspacebelowthecartridges for change-outs.
3.Selectfasteners(notincluded)andtoolsappropriatefortheinstallationlocation(wall,supportstructure
mountedtowallstuds,concrete,etc.)
4. Mount the manifold/filter system to a wall using the mounting holes provided on the back plate of the
metal bracket.
•Itisrecommendedtofirstdrawalevellineonthemountingsurfaceattheheightofthefasteners.
•Markthelocationofthefastenersusingthebracketasatemplateorbymeasuringthedistance
between the mounting holes.
•Installthefastenersandallow1/4”-3/8”(6-10mm)ofeachfastenertoprotrudefromthesurface.
•Installthemanifoldontothefasteners.
•Tightenthefasteners.
5.Installinlet(leftrear)andoutletfittings(rightfronttoice/coffeeandleftfronttobeverage)tothemanifold.
Allconnectionsterminatewitha3/4”NPT(male)fitting.Theinletkitincludesafittingandaballvalve.The
left front outlet is a fitting only. The kit for the right side outlet to ice includes the fitting, a stainless-steel filter head,
(2)nipplesandacheckvalve.Theinstructionsfortheinstallationclipsareonpage5(PTFEtapeisnotincluded).
IMPORTANT NOTES:Besureinstallthestainlesssteelfittingheadwiththeflowarrow.
6. Remove the sanitary caps from the water filter cartridges, and apply a light coat of water or food-grade
lubricant to the o-rings on each of the cartridges.
7.Alignthetabsofthecartridgewiththeslotsintheretainingplateandinsertthecartridgeintothemanifold.
Becertaintoplacethecorrectcartridgesintothecorrectlocation.
8.Turnthecartridgetotherightuntilaclickingsoundisheard.Repeatfortheremainingcartridges;the
clicking sound indicates the cartridge is properly engaged.
9. Install the smaller scale inhibitor cartridge by engagng the threads in the stainless steel tee and rotating to
theright(clockwise)untilsnug,regardlessoffinallabelorientation.
Equipment Start-up Procedure
1. Turn on incoming water to system.
2.Presurizesystembyrotatingtheinletballvalvehandleonthemanifoldtotheright(counterclockwise)to
the “ON” position.
3. Check for leaks.
4. Flush system in accordance with performance data sheet supplied with the water filtration cartridges.
IMPORTANT NOTES
•Failuretofollowinstructionsmayvoidwarranty.
•Allowaminimumof3in.(7.6cm)clearspaceunderfiltertofacilitatecartridgechange.
•Installwiththeinletandoutletportsaslabeled.Makesurenottoreverseconnections.
•Somelocalcodesmayrequiretheuseofalicensedplumberorcertifiedinstallerwhendisruptingapotablewaterline.
CAUTION
To reduce the risk associated with property damage due to water leakage:
•Ensure that the location and fasteners will support the weight of the system when installed and full of water.
CAUTION
To reduce the risk associated with property damage due to water leakage:
•Anynon-metallicfittingsusedintheinstallationsmustbeofadequateratingforthelinepressure.
6