3M TD4i Installation & Operation Manual

Manual is about: One-Piece GPS Offender Tracking System and Curfew Unit

Summary of TD4i

  • Page 1

    3m™ one-piece gps (td4i) offender tracking system and curfew unit installation & operation april 2017 installation guide 3m electronic monitoring.

  • Page 2

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 2 information in this documentation is subject to change without notice and does not represent a commitment on part of 3m™ electronic monitoring. The software described in this document is subject to the license ag...

  • Page 3

    3m electronic monitoring 3 versions and changes table version status/changes author date 1.0 initial release version steve graniewitz 03-apr-2017.

  • Page 4: Safety Information

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 4 safety information please read, understand, and follow all safety information contained in these instructions prior to the use of this 3m electronic monitoring device. Retain these instructions for future referen...

  • Page 5

    3m electronic monitoring 5 warning to reduce the risks associated with hazardous voltage:  do not modify, decorate, or attempt to service the device. Return to 3m authorized personnel or location for repair or service. There are no user serviceable parts.  if the device or power cord becomes damag...

  • Page 6

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 6 safety information only for: rechargeable hand-held/wearable devices non rechargeable hand-held/wearable devices warning to reduce the risks associated with fire or explosion:  do not enter areas with potentiall...

  • Page 7: Fcc

    3m electronic monitoring 7 fcc fcc id: lsq-td4i-433 fcc id: lsq-ideu-830-2 federal communications commission (fcc) part 15 statement the equipment complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)...

  • Page 8: Table Of Contents

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 8 table of contents 1 introduction .......................................................................................................................................... 9 2 main components .......................

  • Page 9: 1  Introduction

    3m electronic monitoring 9 1 introduction the 3m™ one-piece gps offender tracking unit is a wearable device designed specifically for offender monitoring applications. With security redundancies and anti-tamper mechanisms built-in across the platform, the one-piece unit provides a trustworthy and re...

  • Page 10: 2  Main Components

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 10 2 main components the one-piece unit features the following main components: figure 1: one-piece gps unit main components 2.1 led indicators the one-piece unit features three led indicators that inform the offen...

  • Page 11

    3m electronic monitoring 11 figure 2: one-piece gps unit led indicators the following three sections explain the one-piece unit’s led indication during regular operation. Additional status conditions indicated by a combination of leds are explained in section 2.1.4 led indication during activation s...

  • Page 12

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 12 2.1.3 zone led the zone led indicates geographic zone violation status. Led indication led pattern status description led off the offender is not violating any zone restrictions. Flashing red (once per second) t...

  • Page 13

    3m electronic monitoring 13 2.1.5 led indication of vibrate now feature the vibrate now feature enables the monitoring center to send a command to the one-piece unit that causes the unit to vibrate and flash all three led so that the offender will call the monitoring center. Led indication led patte...

  • Page 14: 3  Charging The Unit

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 14 3 charging the unit the one-piece unit can be charged in two different ways; the cord charger attachment and the cordless charger. Both charging options can fully charge a depleted battery in 2.5 to 3 hours. 3.1...

  • Page 15

    3m electronic monitoring 15 when attached to the one-piece unit, the cordless charger charges the device while allowing the offender to go about their daily routine unhindered. Figure 5: one-piece gps unit with cordless charger attached.

  • Page 16

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 16 4 installing the one-piece gps unit installing the one-piece gps unit involves: assembling the appropriate equipment verifying that the offender is registered in the 3m™ offender management software activating t...

  • Page 17

    3m electronic monitoring 17 4.1.3 offender information in the 3m™ offender management software verify the following offender details in the 3m™ offender management software application: offender’s name and address offender’s program type – 1 piece equipment serial numbers –these must match the seria...

  • Page 18

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 18 figure 7: positioning the curfew unit if the house has two floors, it is recommended that you install the curfew unit on the first floor. If the house has three floors, it is recommended that you install the cur...

  • Page 19

    3m electronic monitoring 19 figure 8: curfew unit led indication the following table explains the role of each of the curfew units led indicators. Led description receive flickers when a transmission is received by the curfew unit. Transmit flickers when a transmission is sent by the curfew unit. Ba...

  • Page 20

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 20 3. Push the tamper plug into the slot making sure to enter the right side first. 4. Secure the tamper plug by pushing the left side of the tamper plug into the slot. 4.5 preparing the strap before attaching the ...

  • Page 21

    3m electronic monitoring 21 6. Examine the end of the strap to ensure that the edge is even with the silicone plug and that no gaps are visible 7. Insert the strap with the attached pin tray into the bracket of the strap installation tool. 8. Place the strap installation tool with the strap around t...

  • Page 22

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 22 11. Squeeze the two handles of the strap installation tool to cut the extra strap. 12. Attach the second pin tray to the other side of the strap as explained in steps 3, 4, 5 and 6. 4.6 attaching the one-piece g...

  • Page 23

    3m electronic monitoring 23 4.7 activating the one-piece gps unit after the one-piece unit is firmly secured to the offender’s ankle, you are ready to activate. For a detailed description of the led indications displayed during the activation sequence, see 2.1.4 led indication during activation sequ...

  • Page 24: 5  Status Alerts

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 24 5 status alerts the following sections provide a reference to the various status alerts and indications that can be generated by the one-piece unit. 5.1 low battery a low battery alert shows that the one-piece u...

  • Page 25

    3m electronic monitoring 25 geographic zone alerts are indicated as follows: if vibration notification is enabled, the device initially vibrates three times. The zone led flashes red once every second until the zone violation is resolved. If vibration notification is enabled, the device vibrates onc...

  • Page 26

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 26 6 dismantling the one-piece gps unit dismantling the one-piece unit involves: performing an end of service (when applicable). Removing and packing the one-piece gps unit. Removing and packing the curfew unit. 6....

  • Page 27

    3m electronic monitoring 27 to remove the one-piece unit from the offender’s ankle: 1. Spread the handles of the strap installation tool. 2. Insert the one-piece unit’s strap in the strap cutting slot. 3. Squeeze the handles together to cut the strap and remove the one-piece unit from the offender’s...

  • Page 28

    Installation guide: 3m™ one-piece gps (td4i) offender tracking system and curfew unit 28 6.4 removing the curfew unit to remove the curfew unit: 1. Disconnect the curfew unit from the external power source. The curfew unit turns off. 2. Pack the curfew unit into its original carrying case..