4xem W80 User Manual - page 77
- 73 -
matched
mdalarm
0/1
Enable/Disable DO trigger when motion
detection condition matched
ioupload
0/1
Enable/Disable upload snapshot when DI
condition matched
mdupload
0/1
Enable/Disable upload snapshot when motion
detection condition matched
seqop
0/1
Enable/Disable sequential operation
sinter
1 ~ 99999
Interval of sequential snapshot in second
Send snapshot by e-mail
smethod
ftp
Send snapshot by ftp
suffix
0/1
Enable/Disable FTP put snapshots with date and
time suffix
resetdo
0/1
Reset/No reset DO when click save button
Example: Enable sequential send snapshot by every 1 second with email.
http://myserver/setup/app.vspx?method=set&exclude=1&eventop=0&seqop=1&
smethod=mail&sinter=1
Drive the digital output
Note: This request requires the privilege of I/O access control.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/setdo.cgi?do1=
[&do3=
Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents