A&D FS-D Setup Instructions

Manual is about: Weighing Indicator for Check Weighing Scales

Summary of FS-D

  • Page 1

    Weighing indicator for check weighing scales 1wmpd4002313.

  • Page 2

    This manual and marks all safety messages are identified by the following, “warning” or “caution”, of ansi z535.4 (american national standard institute: product safety signs and labels). The meanings are as follows: warning a potentially hazardous situation which, if not avoided, could result in dea...

  • Page 3

    1 contents 1. Compliance ................................................................................................. 2 2. Introduction .............................................................................................. 3 3. Unpacking ....................................................

  • Page 4: 1. Compliance

    2 1. Compliance compliance with fcc rules please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a class a computing device pursuant to subpart j of part 15 of fcc rules. These rules are d...

  • Page 5: 2. Introduction

    3 2. Introduction this manual describes how this product works and how to get the most out of it in terms of performance. The fs-d weighing indicator is used to build high performance check weighing scales. It has similar specifications and functions as an indicator of the fs-i series. Please refer ...

  • Page 6: 3. Unpacking

    4 3. Unpacking unpack the indicator carefully and keep the packing material if you are likely to transport the indicator again in the future. When unpacking, check whether all of the following items are included: fs-i series instruction manual instruction manual fs-i series fs-d set up instruction s...

  • Page 7

    5 4. Installation and precautions 4-1. Precautions for installing the indicator ground the indicator so that the user will not be subjected an electric shock. Do not handle the main power cord with wet hands. The ac plug is not water-resistant. Install it in an area where it does not get wet. Do not...

  • Page 8

    6 setscrew b setscrew a 4. Solder the wires to the pin contacts of the connector. A 5 m or less load cell cable is recommended as the fs-d uses a 4 wire system (no remote sensing). 5. Reassemble the connector plug and tighten the setscrew a. 6. Move the load cell cable back and forth and around, and...

  • Page 9

    7 4-4. Setting up the indicator connect the main power cord to an outlet that has an earth ground terminal. You may use the earth terminal on the rear side of the display to ground the indicator. If necessary, adjust the viewing angle of the display by loosening the 2 clamps, changing the angle and ...

  • Page 10: 5. Names And Functions

    8 5. Names and functions no. Names functions / operation weight data display indicates the weight data. Weighing unit indicator indicates the weighing unit in use. Analog weight display indicates zero to full scale or comparison limits and results. Over range indicators turns on when the weight is o...

  • Page 11

    9 no. Names functions / operation comparison indicators indicates the results of the weight comparison lo (red), ok (green) and hi (yellow). Stable annunciator turns on when the weight reading is stable. Zero annunciator turns on when the weight is in the center of zero range. Net annunciator turns ...

  • Page 12

    10 6. Function parameter settings to design a platform scale, set the capacity, weighing unit and other functions according to the specifications of the scale. Normally, end users do not have to set these function parameters and these setting can be sealed together with the calibration switch. 6-1. ...

  • Page 13

    11 6-2. Function list item function number description c01-0 cal switch enabled, 0 key enabled c01-1 cal switch disabled, 0 key disabled calibration c01-2 cal switch enabled, 0 key disabled do not set “c01-1” c02-0 6 kg (15 lb) c02-1 15 kg (35 lb) c02- 2 30 kg (70 lb) c02-3 60 kg (150 lb) c02-4 150 ...

  • Page 14: 7. Calibration

    12 7. Calibration this function adjusts the scale (indicator) for accurate weighing. Calibration must be done when the fs-d is initially connected to a load cell (base unit). Calibration may also be required according the changes in the environment. When the scale (indicator) has been moved. When th...

  • Page 15

    13 if you need zero calibration but do not need span calibration, turn the power off to exit from the calibration procedure. 7. To calibrate with a different weight, change the displayed value using the 10-key pad. If you enter the wrong number, press the c key. The value returns to the capacity and...

  • Page 16: 8. Auto-Tare Function

    14 8. Auto-tare function the fs-d has an auto-tare function to be used with the comparator function enabled. If the weight value is within the ok range and stable for a preset time, then the indicator will automatically tare the weight and show zero. The function “f22” designates the timing to tare ...

  • Page 17: 9. Additional Information

    15 9. Additional information this section describes the additional functions and corrections to the instruction manual of fs-i series (wm+pd4001332 and 1wmpd4001368) which are common to the fs-d. 9-1. F-function list the following function settings are added (“11-2. Function list” in wm+pd4001332). ...

  • Page 18

    16 the frame ground and the shield are connected internally and there is no difference between them in use. Data format example of data out of range “kg” (+) o l , + 9 9 9 9 9 9 9 9 _ k g c r l f out of range “kg” (+) o l , + 9 9 9 9 . 9 9 9 _ k g c r l f the position of decimal point is different a...

  • Page 19

    17 command h i , + 0 0 1 0 0 c r l f assume 2 decimal place number. Reply h i , + 0 0 1 0 0 c r l f 1.00% will be set as lo limit %. Command l o , + 0 0 1 0 0 c r l f assume 2 decimal place number. Reply l o , + 0 0 1 0 0 c r l f 1.00% will be set as lo limit %. Store the comparator limits into the ...

  • Page 20: 10. Error Messages

    18 10. Error messages overload error warning to indicate that an object beyond the weighing capacity has been placed on the weighing pan. Remove the object from the weighing pan. Power-on error warning to indicate that an object beyond the power-on zero range (50% of the weighing capacity or 10%) is...

  • Page 21: 11. Specifications

    19 11. Specifications 11-1. Capacity and minimum display c02- setting 0* 1 2 3 4 5 6 7 capacity 6 15 30 60 150 300 600 1500 0.002* 0.005 0.01 0.02 0.05 0.1 0.2 0.5 0.001 0.002 0.005 0.01 0.02 0.05 0.1 0.2 kg min. Display 0.0005 0.001 0.002 0.005 0.01 0.02 0.05 0.1 capacity 6000 15000 30000 2* 5 10 1...

  • Page 22

    20 11-3. Options op-02 (hc-02i) sla battery (yuasa battery np4-6 recommended.) op-03 (fs-03i) rs-232c + comparator relay output (see note.) op-04 (fs-04i) rs-422/485 + comparator relay output (see note.) note op-03 and op-04 cannot coexist. 11-4. Dimensions unit: mm.

  • Page 24

    3-23-14 higashi-ikebukuro, toshima-ku, tokyo 170-0013 japan telephone: [81] (3) 5391-6132 fax: [81] (3) 5391-6148 a&d engineering, inc. 1756 automation parkway, san jose, california 95131 u.S.A. Telephone: [1] (408) 263-5333 fax: [1] (408)263-0119 a&d instruments limited unit 24/26 blacklands way, a...