    Digital platform scale hv-15kgl hv-15kgv hv-60kgl hv-60kgv hv-200kgl hv-200kgv hw-10kgl hw-10kgv hw-60kgl hw-60kgv hw-100kgl hw-100kgv hw-200kgl hw-200kgv hw-300kgl4 hw-300kgv4 hw-600kgl4 hw-600kgv4 hw-600kgl3 hw-600kgv3 hw-1200kgl3 hw-1200kgv3 1wmpd4000041d.

  • Page 2

    This is a hazard alert mark. This mark informs you about the operation of the product. Note this manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent...

  • Page 3

    Hv-g/hw-g series page 1 contents 1. Compliance................................................................................................ 3 1.1. Compliance with fcc rules.................................................................... 3 2. Outline and features .................................

  • Page 4

    Page 2 hv-g/hw-g series 11. Upper/lower comparator function...................................................... 36 11.1. Preparation (setting parameters) ........................................................ 37 11.2. Operation and performance (examples).............................................

  • Page 5

    Hv-g/hw-g series page 3 1. Compliance 1. Compliance 1.1. Compliance with fcc rules please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a class a computing device pursuant to subpart j o...

  • Page 6

    Page 4 hv-g/hw-g series 2. Outline and features 2. Outline and features the hv-g series are platform scales with 1/3000 resolution, and have the triple weighing range function to select the weighing range. The hw-g series come with two types of resolution; 1/6000 : hw-300kgl4, hw-300kgv4, hw-600kgl4...

  • Page 7

    Hv-g/hw-g series page 5 3. Unpacking 3. Unpacking models hv-15kgl hv-15kgv hw-10kgl hw-10kgv display unit base unit hv-60kgl hw-60kgl hv-60kgv hw-60kgv models pan display unit base unit hv-200kgl hw-100kgl hw-200kgl hv-200kgv hw-100kgv hw-200kgv models pan caution do not pull the load cell cable. Al...

  • Page 8

    Page 6 hv-g/hw-g series 3. Unpacking models hw-300kgl4 hw-300kgv4 hw-600kgl4 hw-600kgv4 set of allen screws for pole installation (with allen wrench) models hw-600kgl3 hw-600kgv3 hw-1200kgl3 hw-1200kgv3 pan pan base unit base unit display unit display unit caution do not pull the load cell cable. Ca...

  • Page 9

    Hv-g/hw-g series page 7 3. Unpacking 3.1. Accessories and options list accessories list type models accessories (quantity) a hv-15kgv hw-10kgv display unit cover (1) instruction manual (1) hv-60kgv hv-200kgv hw-60kgv hw-100kgv hw-200kgv display unit cover (1) allen wrench (1) instruction manual (1) ...

  • Page 10

    Page 8 hv-g/hw-g series 3. Unpacking options list order code / option name accessories a op-02 extension load cell cable (for weighing capacity of 10 kg to 200 kg) extension load cell cable (for weighing capacity of 300 kg to 1200 kg) tapping screw m4x10 a op-03 rs-232c interface/ relay output/ buzz...

  • Page 11

    Hv-g/hw-g series page 9 4. Caution 4. Precautions 4.1. Installing the scale consider the following conditions to get the most from your scale. Install the scale where the temperature and relative humidity is stable, there is no draft and a stable power source is available. Install the scale on a sol...

  • Page 12

    Page 10 hv-g/hw-g series 5. Installing the scale 5. Installing the scale 5.1. Setting up the scale the setup procedure depends on the scale model. Refer to the table below. Models refer to hv-15kgl/hv-15kgv/hv-60kgl/hv-60kgv/hv-200kgl/hv-200kgv/hw-10kgl hw-10kgv/hw-60kgl/hw-60kgv/hw-100kgl/hw-100kgv...

  • Page 13

    Hv-g/hw-g series page 11 5. Installing the scale 5.1.2. Procedure b hw-300kgl4/hw-300kgv4 hw-600kgl4/hw-600kgv4 note the display unit, the pole and the base unit are connected using cables. So, use care when lifting the display unit. Step 1 take the base unit, pole and display unit out, taking care ...

  • Page 14

    Page 12 hv-g/hw-g series 5. Installing the scale 5.1.3. Procedure c hw-600kgl3/hw-600kgv3 hw-1200kgl3/hw-1200kgv3 note the display unit, the pole and the base unit are connected using cables. So, use care when lifting the display unit. Step 1 take the scale out. The pole, the display unit and the ac...

  • Page 15

    Hv-g/hw-g series page 13 5. Installing the scale 5.2. Installing the batteries for type l step 1 turn off the display. Remove the ac adapter. Step 2 press and slide the ext. Cover to open it. Press the hook of the int. Cover to the left side and lift it. Step 3 insert six new batteries with proper p...

  • Page 16

    Page 14 hv-g/hw-g series 5. Installing the scale 5.3. Removing the pole caution remove the ac plug from the receptacle before removing the pole (type v). Remove the ac adapter and batteries before removing the pole (type l). When removing the load cell cable, do not pull on the load cell cable conne...

  • Page 17

    Hv-g/hw-g series page 15 5. Installing the scale step 9 wind the cable through the ferrite core two times. Affix the cable to the rear cover using the cable clamp. Step 10 connect the cable to the connector. Close the rear cover. Step 11 check the weighing accuracy. 5.3.2. Procedure b step 1 turn th...

  • Page 18

    Page 16 hv-g/hw-g series 5. Grounding the scale 5.4. Grounding the scale when using where there may be static electricity, ground the scale. The grounding procedure depends on the scale model. Refer to the table below. These procedures are only for grounding part of the scale. Models refer to hv-15k...

  • Page 19

    Hv-g/hw-g series page 17 6. Description of each part 6. Description of each part.

  • Page 20

    Page 18 hv-g/hw-g series 6. Description of each part.

  • Page 21

    Hv-g/hw-g series page 19 6. Description of each part 6.1. Display and symbols display and symbols description a stability mark when the current weight value is stable, this mark is displayed. It means a proper condition that this value is readable. A a a a zero point mark when the zero key is presse...

  • Page 22

    Page 20 hv-g/hw-g series 6. Description of each part display and symbols description a counting mode (example) this mode uses the stored unit mass and counts the number of articles on the pan. The unit is . A a a a storing the unit mass for the counting mode (example) the unit mass is stored, using ...

  • Page 23

    Hv-g/hw-g series page 21 6. Description of each part d isplay and symbols description a calibration error the calibration mass is too heavy. Check the base unit and the weighing pan. A a a a does not display zero when the scale is turned on. Remove anything that is on the weighing pan. Perform zero ...

  • Page 24

    Page 22 hv-g/hw-g series 6. Description of each part function table: used to select a parameter. A display and symbols description a set key, key normal weighing mode: used to turn the comparator on or off. (refer to f6 ) counting mode: used to enter the mode to store the unit mass. Percentage mode:...

  • Page 25

    Hv-g/hw-g series page 23 7. Basic operation 7. Basic operation 7.1. Turning the scale on/off and weighing 7.1.1. Type v or type l with ac adapter step 1 ground the scale. Step 2 confirm that nothing is placed on the pan. Step 3 confirm that local voltage and receptacle type are correct. Step 4 the s...

  • Page 26

    Page 24 hv-g/hw-g series 7. Basic operation 7.1.2. Type l with batteries step 1 install six new batteries. Refer to "5.2. Installing the batteries for type l". Step 2 confirm that nothing is placed on the pan. Step 3 the scale turns on/off using the on/off key alternately. Step 4 check the accuracy ...

  • Page 27

    Hv-g/hw-g series page 25 7. Basic operation 7.2. Tare (and net display) the "tare" is used to cancel the mass of a container, which is placed on the pan to contain the article to be weighed. Caution the tare reduces the weighing range. The current tare value is reset by pressing the zero key or turn...

  • Page 28

    Page 26 hv-g/hw-g series 7. Basic operation 7.3. Weighing range for the hv-g series this is the function to select a weighing range for the hv-g series. The mass value is displayed within a selected range. Select automatic range (f2 0) or manual range (f2 1) in the function table. Operation and perf...

  • Page 29

    Hv-g/hw-g series page 27 7. Basic operation 7.4. Mode key (changing unit and mode) pressing the mode key changes the display as follows. Refer to function table f3 for units. Usable units are according to the factory settings. Pound-ounce accumulation count accumulation value m+ or m+ or either func...

  • Page 30

    Page 28 hv-g/hw-g series 7. Basic operation description the status of "inactive comparator ( f6 )" is that comparator function ( f6 0 , f6 2 , f6 4 , f6 6 ) is selected and this comparator is not used. The comparator can be selected to be on or off using the set key alternately. The following parame...

  • Page 31

    Hv-g/hw-g series page 29 8. Counting mode 8. Counting mode the counting mode is the function to convert the total mass value (total weight) of articles to a count, when each article has the same mass value. To use this function, store a unit mass in advance. Even if the ac adapter or the batteries i...

  • Page 32

    Page 30 hv-g/hw-g series 8. Counting mode 8.2. Counting the number of articles step 1 press the mode key to display the unit . Step 2 store the unit mass of the article. Refer to "8.1. Storing a unit mass" step 3 place the container on the pan. Press the tare key. Step 4 place articles in the contai...

  • Page 33

    Hv-g/hw-g series page 31 9. Percentage mode 9. Percentage mode the percentage mode is the function to display a mass value in the unit of "%". To use this function , store a 100% mass value in advance. The 100% mass value is stored in the scale even if the power is removed. 9.1. Storing a 100% mass ...

  • Page 34

    Page 32 hv-g/hw-g series 9. Percentage mode 9.2. Reading the percentage step 1 press the mode key to display the unit %. Step 2 store the 100% mass of the article. Refer to "9.1. Storing a 100% mass " step 3 place the container on the pan. Press the tare key. Step 4 place articles in the container. ...

  • Page 35

    Hv-g/hw-g series page 33 10. Accumulation function 10. Accumulation function this function counts the number of times articles are weighed, calculates the total mass value and can display the number (accumulation count) and accumulated mass value. The accumulation function is displayed with up to 6 ...

  • Page 36

    Page 34 hv-g/hw-g series 10. Accumulation function function table description a f8 3 when the display is a positive stable value and not nearly-zero, the scale accumulates the data automatically. The next accumulation can be performed after the display becomes nearly-zero or a negative value. F8 4 w...

  • Page 37

    Hv-g/hw-g series page 35 10. Accumulation function 10.2. Operation and performance (examples) example 1 in this example, the scale accumulates the value each time an article is weighed. The function parameter is set to f8 3 . Step 1 press the mode key to display or . Step 2 press the zero key to res...

  • Page 38

    Page 36 hv-g/hw-g series 11. Upper/lower comparator function 11. Upper/lower comparator function this function compares a weight value with the upper limit (hi) and the lower limit (lo) and displays the results. To use this function, set the "comparator function ( f6 0 to f6 7 )" parameters in the f...

  • Page 39

    Hv-g/hw-g series page 37 11. Upper/lower comparator function function table description a f6 7 when the weight value becomes stable and not nearly-zero, the scale compares the value. It does not compare on an unstable condition. A a caution the upper limit value (hi) must be greater than the lower l...

  • Page 40

    Page 38 hv-g/hw-g series 11. Upper/lower comparator function step 5 if either of f6 0 , f6 2 , f6 4 , f6 6 has been selected, press the set key to use the comparator. Step 6 press the mode key to display the blinking hi. Step 7 set the upper limit value using the following keys. < key selecting the ...

  • Page 41

    Hv-g/hw-g series page 39 11. Upper/lower comparator function 11.2. Operation and performance (examples) example 1 this example is set as follows: function table f6 1 (the scale always compares the weight value even when the value is nearly-zero.) upper limit value (hi) 7.000 kg lower limit value (lo...

  • Page 42

    Page 40 hv-g/hw-g series 12. Full/dribble batch function 12. Full/dribble batch function this function changes the scale to a filling machine which sub-divides a bulk product ( like grain) into loads of predetermined and virtually constant mass. To use this function, set the parameter of the "compar...

  • Page 43

    Hv-g/hw-g series page 41 12. Full/dribble batch function caution the comparison of the full/dribble batch function can not be restored. (one way sequence). If the weight value becomes less than the final value after the value reached a predetermined target value, neither hi nor lo is on. The paramet...

  • Page 44

    Page 42 hv-g/hw-g series 12. Full/dribble batch function 12.1. Preparation (setting parameters) step 1 turn off the display. Press and hold the zero key and press the on/off key. The function table is displayed. Step 2 press the enter key to display an item of the comparator function ( f6 ). Step 3 ...

  • Page 45

    Hv-g/hw-g series page 43 12. Full/dribble batch function step 8 press the mode key to display the blinking hi (of the final value). Step 9 set the final value using the following keys. < key selecting the figure to be changed. ∧ key changing the number of the figure. Step 10 press the enter key to s...

  • Page 46

    Page 44 hv-g/hw-g series 13. Simple batch function 13. Simple batch function this function compares a weight value with the final value, preliminary value and zero band for the full/dribble batch function. The result is indicated by zero band (lo indicator), full flow (hi indicator) and dribble flow...

  • Page 47

    Hv-g/hw-g series page 45 13. Simple batch function caution the parameters of the upper limit value (hi) and a final value (hi) use the same memory. The parameters of the lower limit value (lo) and the preliminary value (ok) use the same memory. The upper/lower comparator function, the simple batch f...

  • Page 48

    Page 46 hv-g/hw-g series 13. Simple batch function step 6 press the mode key to display the blinking hi (of the final value). Step 7 set the final value using the following keys. < key selecting the figure to be changed. ∧ key changing the number of the figure. Step 8 press the enter key to store th...

  • Page 49

    Hv-g/hw-g series page 47 14. Calibration (adjusting scale) 14. Calibration (adjusting the scale) the scale is an instrument which weighs the "weight" and displays its "mass". Calibration is the adjustment function so that the scale can weigh correctly. Three steps of calibration are available gravit...

  • Page 50

    Page 48 hv-g/hw-g series 14. Calibration (adjusting scale) 14.1. Gravity acceleration table amsterdam 9.813 m/s 2 manila 9.784 m/s 2 athens 9.800 m/s 2 melbourne 9.800 m/s 2 auckland, nz 9.799 m/s 2 mexico 9.779 m/s 2 bangkok 9.783 m/s 2 milan 9.806 m/s 2 birmingham 9.813 m/s 2 new york 9.802 m/s 2 ...

  • Page 51

    Hv-g/hw-g series page 49 14. Calibration (adjusting scale) 14.2. Complete calibration procedure 14.2.1. Gravity acceleration correction step 1 turn on the display. Open the rear cover of the display unit. Locate the cal switch inside. Press and hold the cal switch to enter the calibration mode. Then...

  • Page 52

    Page 50 hv-g/hw-g series 14. Calibration (adjusting scale) 14.2.3. Calibration of the zero point step 8 after 30-minute warm up, press and hold the cal switch to enter the calibration mode. Then the cal 0 is displayed. Step 9 confirm that nothing is placed on the pan. Wait for the stability mark to ...

  • Page 53

    Hv-g/hw-g series page 51 15. The function table 15. Function table the function table is used to store and refer items that determine the performance of the scale. Each item has a parameter. The parameters are stored in the scale even if the power is removed. 15.1. Parameter setting procedure step 1...

  • Page 54

    Page 52 hv-g/hw-g series 15. The function table 15.2. Parameter list item display description A the type l scale is turned off after 5 minutes of no operation, when zero is displayed. A A f1 0 # not used A automatic turning off f1 1 used A selects how to change the weighing range for hv-l and hv-g s...

  • Page 55

    Hv-g/hw-g series page 53 15. The function table item display description A f6 4 when the weight value becomes stable after the set key is pressed, the scale compares the weight value. It does not compare on an unstable condition. Press the set key again to stop the comparison. A a a a f6 5 when the ...

  • Page 56

    Page 54 hv-g/hw-g series 15. The function table item display description A f8 4 when the display is a stable value and not nearly-zero, the scale accumulates the data automatically. The next accumulation can be performed after the display becomes nearly-zero. Use recording the number and mass of art...

  • Page 57

    Hv-g/hw-g series page 55 15. The function table item display description A selects the method to hold the current weight value. When the weight value becomes nearly-zero or changes more than 25% +30 digits, hold display is canceled. A A A f12 0 # not used A f12 1 the hold function is on or off alter...

  • Page 58

    Page 56 hv-g/hw-g series 16. Rs-232c serial interface 16. Rs-232c serial interface note when the rs-232c serial interface is used, be sure to set the “address ( f11 ) “ to “( 00 )”. Rs-232c interface has the following two modes. Stream mode outputs data continuously and can be used to print data. Co...

  • Page 59

    Hv-g/hw-g series page 57 16. Rs-232c serial interface 16.1. Data format bit format format 1 there are four headers for the type of data and weighing condition. Stable weighing data unstable weighing data stable counting data out of range ( over) the weight value consists of 9 characters including de...

  • Page 60

    Page 58 hv-g/hw-g series 16. Rs-232c serial interface format 2 there are four headers for the type of data and weighing condition. Stable weighing data unstable weighing data stable counting data out of range the weight value consists of 7 characters including decimal point and polarity. The polarit...

  • Page 61

    Hv-g/hw-g series page 59 16. Rs-232c serial interface 16.2. Stream mode the scale outputs the current weighing data at the time the display is refreshed. The scale does not output data while in the setting mode. Averaging of function table refresh rate a f13 0 fast response sensitive value approxima...

  • Page 62

    Page 60 hv-g/hw-g series 16. Rs-232c serial interface 16.3. Command mode the command mode is the function which can perform "outputting data", "controlling the scale" and "setting parameters" by a command transmitted from a computer caution allow at least 500 milliseconds between commands. 16.3.1. C...

  • Page 63

    Hv-g/hw-g series page 61 16. Rs-232c serial interface preset tare tare value is set and the net is displayed. The set value is a 5 digit numerical value with a polarity sign and does not contain a decimal point. Template pt, [parameter] command reply net is displayed and the net mark is displayed. U...

  • Page 64

    Page 62 hv-g/hw-g series 16. Rs-232c serial interface final value the final value is stored. The set value is a 5 digit numerical value with a polarity sign and does not contain a decimal point. Template s0, [parameter] command reply the value is stored. Preliminary value the preliminary value is st...

  • Page 65

    Hv-g/hw-g series page 63 16. Rs-232c serial interface 16.3.2. Example of setting parameters step 1 turn off the display. Press and hold the zero key and press the on/off key. The function table is displayed. Step 2 press the enter key to display f4 ("baud rate"). Select a parameter of "baud rate" wi...

  • Page 66

    Page 64 hv-g/hw-g series 17. Options 17. Options 17.1. Extension load cell cable (op-02) this cable is used for installing the indicator away from the base unit. This extension load cell cable is 5 m long. Refer to " 5.3. Removing the pole" for how to remove the pole. Caution calibrate the scale aft...

  • Page 67

    Hv-g/hw-g series page 65 17. Options for models with weighing capacity of 300 kg to 1200 kg.

  • Page 68

    Page 66 hv-g/hw-g series 17. Options 17.2. Rs-232c/ relay output/ buzzer (op-03) note when the op-03 is used, be sure to set the "address ( f11 ) " to "( 00 )". Replace the standard rs-232c interface with this option. Refer to " rs-232c serial interface" for its specification. The following optional...

  • Page 69

    Hv-g/hw-g series page 67 17. Options installing op-03 step 1 remove two screws that attach the rs-232c board on rear of the display unit. Remove the rs-232c board. Step 2 switch the connections. Step 3 insert the option board into the display unit and affix with the screws..

  • Page 70

    Page 68 hv-g/hw-g series 17. Options 17.3. Rs-422/ rs-485 / relay output (op-04) replacing with the standard rs-232c interface, the rs-422/ rs-485 interface can connect up to 16 scales and control them from a computer. The rs-422/ rs-485 interface has the following two modes. Stream mode outputs dat...

  • Page 71

    Hv-g/hw-g series page 69 17. Options circuits caution please confirm that the ac adapter type is correct for your local voltage and receptacle type. Selection switch for the rs-422/ rs-485 interface selects either of rs-422 or rs-485 interface using the switch on the board. Installing op-04 step 1 r...

  • Page 72

    Page 70 hv-g/hw-g series 17. Options an example of connection the polarities (a, b) of the host computer signal depends on the computer model. Host computer hv-g/hw-g address=01 sda sdb rda rdb terminator (may be built in the host computer) sda sdb rda rdb trm sda sdb rda rdb trm sda sdb rda rdb trm...

  • Page 73

    Hv-g/hw-g series page 71 17. Options 17.3.1. Communication format commands consist of an address and the same command as for the rs-232c. The address of the equipment is inserted in the first part of the command. Commands return the same command when the communication format is f15 3 1 and there is ...

  • Page 74

    Page 72 hv-g/hw-g series 17. Options zero the current mass value is set to the zero point. This is the same as the zero key. Template z command reply the mass value becomes zero and zero point mark is displayed. Tare with a tare (container) placed, the current mass value is set to zero, and the net ...

  • Page 75

    Hv-g/hw-g series page 73 17. Options accumulation data output accumulated data is output. Template a command reply accumulation count output number of accumulations is output. Template n command reply reset of accumulation data and accumulation count accumulated data and number of accumulations beco...

  • Page 76

    Page 74 hv-g/hw-g series 17. Options 17.4. Built-in printer for type v (op-06) to use the printer, set the parameter of the "print mode ( f9 )" in the function table. To print the date, set the parameter of the "date ( f17 )" in the function table. Caution the date parameter is not updated automatic...

  • Page 77

    Hv-g/hw-g series page 75 17. Options installing the printer paper (special roll paper) step 1 open the cover. Step 2 cut the paper end for easy insertion. Step 3 install the paper end and press the f and print keys at the same time. (paper feed) step 4 arrange the ribbon using the dial. Step 5 pass ...

  • Page 78

    Page 76 hv-g/hw-g series 18. Specifications 18. Specifications hv-g series models hv-15kgl hv-15kgv hv-60kgl hv-60kgv hv-200kgl hv-200kgv A A weighing capacity [kg] 3 6 15 15 30 60 60 150 220 A min. Weighing (1 digit) [g] 1 2 5 5 10 20 20 50 100 A weighing capacity [lb] # 6 15 30 30 60 150 150 300 5...

  • Page 79

    Hv-g/hw-g series page 77 18. Specifications hw-g series (weighing capacity: 10 kg to 200 kg) models hw-10kgl hw-10kgv hw-60kgl hw-60kgv hw-100kgl hw-100kgv hw-200kgl hw-200kgv A A weighing capacity [kg] 10 60 100 220 A min. Weighing (1 digit) [g] 1 5 10 20 A weighing capacity [lb] # 20 150 200 500 A...

  • Page 80

    Page 78 hv-g/hw-g series 18. Specifications hw-g series (weighing capacity: 300 kg to 1200 kg) models hw-300kgl4 hw-300kgv4 hw-600kgl4 hw-600kgv4 hw-600kgl3 hw-600kgv3 hw-1200kgl3 hw-1200kgv3 A A weighing capacity [kg] 300 600 600 1200 A min. Weighing (1 digit) [g] 50 100 100 200 A weighing capacity...

  • Page 81

    Hv-g/hw-g series page 79 18. Specifications dimensions unit: mm.

  • Page 82

    Page 80 hv-g/hw-g series 18. Specifications unit: mm.

  • Page 83

    Hv-g/hw-g series page 81 19. Maintenance 19. Maintenance refer to "4. Precautions" for use. Refer to "6.1. Display and symbols " and corresponding mode for displayed error code. Refer to "14. Calibration (adjusting the scale)" for precision weighing. Periodically check the accuracy of the weighing. ...

  • Page 84

    Page 82 hv-g/hw-g series memo.

  • Page 85

    Hv-g/hw-g series page 83 memo.

  • Page 86

    Page 84 hv-g/hw-g series memo.