A&D HV-15KV-WP Instruction Manual

Other manuals for HV-15KV-WP: Instruction Manual
Manual is about: Waterproof Digital Platform Scale HV-WP Series; HW-WP Series

Summary of HV-15KV-WP

  • Page 1

    Waterproof digital platform scale hv-15kv-wp hv-60kv-wp hv-200kv-wp hw-10kv-wp hw-60kv-wp hw-100kv-wp hw-200kv-wp 1wmpd4000211b.

  • Page 2

    This is a hazard alert mark. This mark informs you about the operation of the product. Note this manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent...

  • Page 3

    Hv-wp/hw-wp series page 1 contents 1. Compliance ........................................................................ 3 1.1.1. Compliance with fcc rules....................................................... 3 1.1.2. Classification of protection provided by enclosures .................. 3 2. Out...

  • Page 4

    Page 2 hv-wp/hw-wp series 12.1. Preparation (setting parameters)................................................ 35 13. Simple batch function ..................................................... 37 13.1. Preparation (setting parameters)................................................ 38 13.2. Opera...

  • Page 5

    Hv-wp/hw-wp series page 3 2. Outline and features 1. Compliance 1.1.1. Compliance with fcc rules please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a class a computing device pursuant ...

  • Page 6

    Page 4 hv-wp/hw-wp series 2. Outline and features 2. Outline and features these scales are designed to comply with ip-65 of iec 529 the hv-wp series is a platform scale with 1/3000 resolution, and has a "triple weighing range" function to select the weighing range. The hw-wp series is a platform sca...

  • Page 7

    Hv-wp/hw-wp series page 5 3. Unpacking 3. Unpacking models hv-15kv-wp hw-10kv-wp display unit base unit models hv-60kv-wp hw-60kv-wp pan display unit base unit models hv-200kv-wp hw-100kv-wp hw-200kv-wp pan caution do not pull the load-cell cable. 3mm allen wrench all accessories refer to the access...

  • Page 8

    Page 6 hv-wp/hw-wp series 3. Unpacking 3.1. Accessories and options list accessories for the hv-wp series and hw-wp series models accessories a hv-15kv-wp hw-10kv-wp instruction manual a hv-60kv-wp hv-200kv-wp hw-60kv-wp hw-100kv-wp hw-200kv-wp 3mm allen wrench instruction manual a a a a options lis...

  • Page 9

    Hv-wp/hw-wp series page 7 4. Caution 4. Caution 4.1. Precautions for installing the scale ground the scale, so that the user will not be subjected to an electric shock. Do not handle the main power cord with wet hands. The ac plug is not water-resistant. Install it in an area where it does not get w...

  • Page 10

    Page 8 hv-wp/hw-wp series 5. Installing the scale 5. Installing the scale this procedure includes all of the steps for installing the hv-wp series and hw-wp series. Therefore, on some models, there are some unnecessary steps. Step 1 connect the indicator unit to the pole with the accesory knobs and ...

  • Page 11

    Hv-wp/hw-wp series page 9 5. 1. Removing the ploe 5.1. Removing the pole caution remove the main power plug from the receptacle before removing the pole. When removing the loadcell cable, do not pull the loadcell cable connector forcibly and do not pull on the wires of the cable. Do not bend the cab...

  • Page 12

    Page 10 hv-wp/hw-wp series 5. 1. Removing the ploe step 8 removing the bracket from the base unit, requires the following allen wrench. Hv-15kv-wp, hv-60kv-wp, hw-10kv-wp, hw-60kv-wp hv-200kv-wp, hw-100kv-wp, hw-200kv-wp 5mm allen wrench 6mm allen wrench step 9 wind the cable through the ferrite cor...

  • Page 13

    Hv-wp/hw-wp series page 11 5. 2. Grounding the balance 5.2. Grounding the scale when using where there may be static electricity, ground the scale. The grounding procedure depends on the scale model. Refer to the table below. These procedures are only for grounding part of the scale. Models refer to...

  • Page 14

    Page 12 hv-wp/hw-wp series 6.Names 6. Names models hv-15kv-wp hw-10kv-wp models hv-60kv-wp hv-200kv-wp hw-60kv-wp hw-100kv-wp hw-200kv-wp rear of indicator unit cal switch is in a depth of 5cm. Calibrating the scale to weigh correctly. Use the proper oiml class calibration mass. Main power cord load...

  • Page 15

    Hv-wp/hw-wp series page 13 6.1. Display and symbols 6.1. Display and symbols display and symbols meaning a stability mark. When the current weighing value is stable, this mark is displayed, indicating a condition where the value is readable. A a a a zero point mark. With nothing on the weighing pan ...

  • Page 16

    Page 14 hv-wp/hw-wp series 6.1. Display and symbols display and symbols meaning a example. Storing the unit mass of the counting mode. The unit mass is stored, using 20 pieces of samples. The zero value means that no articles are on the pan. A a a a example. Storing the unit mass of the counting mod...

  • Page 17

    Hv-wp/hw-wp series page 15 6.2. Switches display and symbols meaning a does not display zero when the scale is turned on. Remove anything that is on the weighing pan. Perform zero point calibration. Or the weight value is unstable due to drift or vibration when the scale is turned on. A breeze or vi...

  • Page 18

    Page 16 hv-wp/hw-wp series 6.2. Switches display and symbols meaning a set switch. Turns the comparator on/off. (refer to f6 ) counting mode, it is used to enter the mode to store the unit mass. Percentage mode, it is used to enter the mode to store the 100% mass. The full/dribble batch function, it...

  • Page 19

    Hv-wp/hw-wp series page 17 7. Basic operation 7.1. Turning the scale on/off and weighing step 1 ground the scale using the earth terminal. Step 2 place nothing on the weighing pan. Step 3 confirm that local voltage and receptacle type adapt to your scale. Step 4 the scale turns on/off using the on/o...

  • Page 20

    Page 18 hv-wp/hw-wp series 7.2. Tare (and net display) "tare" is used to cancel the mass of a container, receptacle, case, bag, etc. Which is put on the weighing pan to contain the item to be weighed. Caution using a tare value reduces the weighing range. The current tare value is reset by pressing ...

  • Page 21

    Hv-wp/hw-wp series page 19 7. Basic operation 7. Basic operation 7.3. Weighing range for the hv-wp series this is the function to select a weighing range for the hv-wp series. The mass value is displayed within a selected range. Select automatic range (f2 0) or manual range (f2 1) in the function ta...

  • Page 22

    Page 20 hv-wp/hw-wp series 7. Basic operation 7.4. Mode switch (changing unit and mode) pressing the mode switch, the display changes as follows. Refer to function table f3 for units. Usable units are according to the factory settings. Pound-ounce accumulation count accumulation value m+ m+ either f...

  • Page 23

    Hv-wp/hw-wp series page 21 7. Basic operation explanation the status of "inactive comparator ( f6 )" is that comparator function ( f6 0 , f6 2 , f6 4 , f6 6 ) is selected and the comparator is not used. The "active" or "inactive" (on/off) for the comparator can be selected by pressing the set switch...

  • Page 24

    Page 22 hv-wp/hw-wp series 8. Counting mode 8. Counting mode the counting mode is the function to convert the total mass value (total weight) of articles to a count, when each of these articles assume the same mass value. It is necessary to store a unit mass to count articles. Even if the ac adapter...

  • Page 25

    Hv-wp/hw-wp series page 23 8. Counting mode 8.2. Counting the number of articles step 1 press the mode switch to display the unit . Step 2 store the articles unit mass. Refer to "8.1 storing a unit mass" step 3 place the container item only on the weighing pan. Press the tare switch. Step 4 put arti...

  • Page 26

    Page 24 hv-wp/hw-wp series 9. Percentage mode 9. Percentage mode the percent mode is the function to display a mass value in the unit of "%". Store a 100% mass value, in advance, to use this function. The 100% mass value is stored in the scale even if the power is removed. 9.1. Storing a 100% mass s...

  • Page 27

    Hv-wp/hw-wp series page 25 9. Percentage mode 9.2. Reading percentage step 1 press the mode switch to display the unit %. Step 2 store the 100% mass of the article. Refer to "9.1 storing a 100% mass " step 3 if a container is needed, place the tare item only on the weighing pan and press the tare sw...

  • Page 28

    Page 26 hv-wp/hw-wp series 10. Accumulation function 10. Accumulation function this function counts the number of weighed items, calculates the total mass value and can display the number and accumulated mass value. The accumulation function is displayed with up to 6 digits. The balance can not disp...

  • Page 29

    Hv-wp/hw-wp series page 27 10. Accumulation function function table meaning and purpose a f8 4 when the display is a stable value and without nearly-zero, the scale accumulates the data automatically. The next accumulation can be performed after the display is nearly-zero. Use recording the number a...

  • Page 30

    Page 28 hv-wp/hw-wp series 10. Accumulation function 10.2. Operation and performance (examples) example 1 weighing each article, the scale makes the accumulation according to f8 3 . Step 1 press the mode switch to display . Step 2 press the zero switch to reset the accumulation data. Step 3 return t...

  • Page 31

    Hv-wp/hw-wp series page 29 11. Upper/lower comparator function 11. Upper/lower comparator function this function compares a display value with the upper limit (hi), the lower limit (lo) and displays the result. Set the "comparator function ( f6 0 ~ f6 7 )" parameters, upper limit value (hi) and lowe...

  • Page 32

    Page 30 hv-wp/hw-wp series 11. Upper/lower comparator function function table meaning and purpose a f6 7 when the display value becomes stable and not nearly-zero, the scale compares the value. It does not compare on an unstable condition. A a caution the upper limit value (hi) must be greater than ...

  • Page 33

    Hv-wp/hw-wp series page 31 11. Upper/lower comparator function step 5 if either of f6 0 , f6 2 , f6 4 , f6 6 has been selected, press the set switch to use the comparator. Step 6 press the mode switch to display the blinking hi. Step 7 set the upper limit value by using the following switches. ∧ swi...

  • Page 34

    Page 32 hv-wp/hw-wp series 11. Upper/lower comparator function 11.2. Operation and performance (examples) example 1 this example is set as follows: function table f6 1 (the scale always compares the weight value even when the value is nearly-zero.) upper limit value (hi) 7.000kg lower limit value (l...

  • Page 35

    Hv-wp/hw-wp series page 33 12. Full/dribble batch function 12. Full/dribble batch function this function changes the scale to a filling machine which subdivides a bulk product ( like grain) into loads of predetermined and virtually constant mass. Set the parameters of the "comparator function ( f6 9...

  • Page 36

    Page 34 hv-wp/hw-wp series 12. Full/dribble batch function caution the comparison of the full/dribble batch function is a one way sequence (not reversible). If the display value becomes less than the final value after the value reached a predetermined target value, neither hi nor lo is on. The param...

  • Page 37

    Hv-wp/hw-wp series page 35 12. Full/dribble batch function 12.1. Preparation (setting parameters) step 1 turn off the display. Press the on/off switch while the zero switch is pressed and held. The function table is displayed. Step 2 press the enter switch to display an item of the comparator functi...

  • Page 38

    Page 36 hv-wp/hw-wp series 12. Full/dribble batch function step 8 press the mode switch to display the blinking hi (of the final value). Step 9 set the final value using the following switches. ∧ switch selecting the number of a figure. < switch selecting a figure. Step 10 press the enter switch to ...

  • Page 39

    Hv-wp/hw-wp series page 37 13. Simple batch function 13. Simple batch function this function compares a display value with the final value, preliminary value and zero band for the full/dribble batch function. The result is indicated by zero band (lo indicator), full flow (hi indicator) and dribble f...

  • Page 40

    Page 38 hv-wp/hw-wp series 13. Simple batch function caution the parameters of the upper limit value (hi) and a final value (hi) use the same memory. The parameters of the lower limit value (lo) and the preliminary value (ok) use the same memory. The upper/lower comparator function, the simple batch...

  • Page 41

    Hv-wp/hw-wp series page 39 13. Simple batch function step 6 press the mode switch to display the blinking hi (of the final value). Step 7 set the final value using the following switches. ∧ switch selecting the number of a figure. < switch selecting a figure. Step 8 press the enter switch to store t...

  • Page 42

    Page 40 hv-wp/hw-wp series 14. Calibration (adjusting scale) 14. Calibration (adjusting the scale) the scale is an instrument which measures the "weight" and displays its "mass" value. Calibration is the adjustment function so that the scale can weigh correctly. There are three steps to calibration....

  • Page 43

    Hv-wp/hw-wp series page 41 14. Calibration (adjusting scale) 14.1.1. The gravity acceleration table amsterdam 9.813 m/s 2 manila 9.784 m/s 2 athens 9.800 m/s 2 melbourne 9.800 m/s 2 auckland nz 9.799 m/s 2 mexico city 9.779 m/s 2 bangkok 9.783 m/s 2 milan 9.806 m/s 2 birmingham 9.813 m/s 2 new york ...

  • Page 44

    Page 42 hv-wp/hw-wp series 14. Calibration (adjusting scale) 14.2. The complete calibration procedure 14.2.1. Gravity acceleration correction step 1 turn on the display. Open the rear cover of the display unit. Press and hold the cal switch, it is in the depth of 5cm, to enter the calibration mode. ...

  • Page 45

    Hv-wp/hw-wp series page 43 14. Calibration (adjusting scale) 14.2.3. Calibration of the zero point step 8 press and hold the cal switch to enter the calibration mode after displaying normal weighing for 30 minutes. Then cal 0 is displayed. Step 9 with nothing on the weighing pan, press the enter swi...

  • Page 46

    Page 44 hv-wp/hw-wp series 15. The function table 15. The function table the function table is the function to store and refer items that determine the performance of the scale. Each item has a parameter. The parameters are maintained even without power applied. 15.1. The procedure for setting param...

  • Page 47

    Hv-wp/hw-wp series page 45 15. The function table 15.2. Parameter list item display meaning and purpose A f1 not used selects the way of changing weighing range for hv-wp series. A f2 0 # automatic range A weighing range f2 1 manual range using the range switch. A selection of the first unit at the ...

  • Page 48

    Page 46 hv-wp/hw-wp series 15. The function table item display meaning and purpose A f6 5 when the display value becomes stable, the scale compares the display value. It does not compare on an unstable condition. A a f6 6 when the display value becomes stable when not nearly-zero after pressing the ...

  • Page 49

    Hv-wp/hw-wp series page 47 15. The function table item display meaning and purpose A f9 not used the details of the full/dribble batch function (f6 9) A f10 0 # reaching final value and pressing the f switch, the current process is finished. A a f10 1 reaching final value and displaying the stabilit...

  • Page 50

    Page 48 hv-wp/hw-wp series 16. Rs-232c serial interface 16. Rs-232c serial interface note when the rs-232c serial interface is used, be sure to set the "address ( f11 ) " to "( 00 )". The rs-232c interface has the following two modes. Stream mode outputs data continuously and can be used for printin...

  • Page 51

    Hv-wp/hw-wp series page 49 16. Rs-232c serial interface 16. Rs-232c serial interface 16.1. Data format bit format format 1 there are four headers for the type of data and weighing condition. Stable weighing data unstable weighing data stable counting data out of range ( over) the weighing data consi...

  • Page 52

    Page 50 hv-wp/hw-wp series 16. Rs-232c serial interface format 2 there are four headers for the type of data and weighing condition. Stable weighing data unstable weighing data stable counting data out of range the weighing data consists of 7 characters including decimal point and polarity. The pola...

  • Page 53

    Hv-wp/hw-wp series page 51 16. Rs-232c serial interface 16.2. Stream mode the scale outputs the current display data at the time when refreshing the display. The scale does not output data while in the setting mode. Averaging of function table refresh rate a f13 0 fast response sensitive value appro...

  • Page 54

    Page 52 hv-wp/hw-wp series 16. Rs-232c serial interface 16.3. Command mode the command mode is the function which can perform "output data", "controlling the scale" and "setting parameters" by a command transmitted from a computer caution allow at least 500 milliseconds between commands. 16.3.1. Com...

  • Page 55

    Hv-wp/hw-wp series page 53 16. Rs-232c serial interface preset tare the tare value is set and the net value is displayed. The set value is a 5 digit numerical value with a polarity sign and does not contain a decimal point. Template pt, [parameter] command reply net is displayed and the net mark is ...

  • Page 56

    Page 54 hv-wp/hw-wp series 16. Rs-232c serial interface final value the final value is stored. The set value is a 5 digit numerical value with a polarity sign and does not contain a decimal point. Template s0, [parameter] command reply the value is stored. Preliminary value the preliminary value is ...

  • Page 57

    Hv-wp/hw-wp series page 55 16. Rs-232c serial interface 16.3.2. Example of setting parameters step 1 turn off the display. Press the on/off switch while the zero switch is pressed and held. The function table is displayed. Step 2 press the enter switch to display f4 ("baud rate"). Select a parameter...

  • Page 58

    Page 56 hv-wp/hw-wp series 17.1. Extension cable (op-02) 17. Options 17.1. Extension cable (op-02) this cable is used for installing the indicator away from the base unit. This loadcell cable is 5m long. Refer tos " 5.1. Removing the pole" for the way to remove the pole. Caution calibrate the scale ...

  • Page 59

    Hv-wp/hw-wp series page 57 17.2. Op-03, options 17.2. Rs-232c/ relay output/ buzzer (op-03) note when the op-03 is used, be sure to set the "address ( f11 ) " to "( 00 )". This option replaces the standard rs-232c interface, refer to "16. Rs-232c serial interface" for specification of rs-232c. The f...

  • Page 60

    Page 58 hv-wp/hw-wp series 17.2. Op-03, options 17.2.1. Installing the op-03 caution do not pull on the connected cables while opening the rear panel. Step 1 remove the plastic panel from the option board. Step 2 remove eight pairs of screws and o rings from the indicator unit. Open the rear panel o...

  • Page 61

    Hv-wp/hw-wp series page 59 17.3. Op-04, options 17.3. Rs-422/ rs-485 / relay output (op-04) replacing the standard rs-232c interface with this option, the rs-422/ rs-485 interface can connect up to 16 scales and control them from a computer. The rs-422/ rs-485 interface has the following two modes. ...

  • Page 62

    Page 60 hv-wp/hw-wp series 17.3. Op-04, options circuits selection switch for the rs-422/ rs-485 interface selects either of rs-422 or rs-485 interface using a switch on the board. 17.3.1. Installing the op-04 caution do not pull on the connected cables while opening the rear panel. Step 1 remove ei...

  • Page 63

    Hv-wp/hw-wp series page 61 17.3. Op-04, options an example of connection the polarities (a,b) of the host computer signal depends on the computer model. 17.3.2. Communication format commands consist of an address and the same command as for the rs-232c. The address of the equipment is inserted in th...

  • Page 64

    Page 62 hv-wp/hw-wp series 17.3. Op-04, options 17.3.3. Command list the following explanation uses "format 1 ( f15 3 )" assuming 23 as the address. Data output the current weighing data is output. Template q command reply selection of mode and unit selects the mode and unit. This is the same as the...

  • Page 65

    Hv-wp/hw-wp series page 63 17.3. Op-04, options lower limit value a lower limit value is stored. The set value is a 5 digit numerical value with a polarity sign and does not contain a decimal point. Template lo, [parameter] command reply the lower limit value is stored. Caution the lower limit value...

  • Page 66

    Page 64 hv-wp/hw-wp series 17.3. Op-04, options 17.4. Op-13, op-14, options 17.4. Roller conveyor (op-13, op-14) caution - when installing the roller conveyor, calibrate the scale again if necessary. - when installing the roller conveyor, if not calibrating the scale again, the weighing capacity of ...

  • Page 67

    Hv-wp/hw-wp series page 65 18. Specification 18. Specification hv-wp series models hv-15kv-wp hv-60kv-wp hv-200kv-wp A A weighing capacity [kg] 3 6 15 15 30 60 60 150 220 A min. Weighing (1 digit) [g] 1 2 5 5 10 20 20 50 100 A weighing capacity [lb] # 6 15 30 30 60 150 150 300 500 A min. Weighing (1...

  • Page 68

    Page 66 hv-wp/hw-wp series 18. Specification hw-wp series models hw-10kv-wp hw-60kv-wp hw-100kv-wp hw-200kv-wp A A weighing capacity [kg] 10 60 100 220 A min. Weighing (1 digit) [g] 1 5 10 20 A weighing capacity [lb] # 20 150 200 500 A min. Weighing (1 digit) [lb] # 0.002 0.01 0.02 0.05 A weighing c...

  • Page 69

    Hv-wp/hw-wp series page 67 18. Specification dimensions 90~130 55 334 45 330 615 424 786 35 180 60 90~130 437 250 250 466 hv-15kv-wp hw-10kv-wp hv-60kv-wp hw-60kv-wp models models 45 240 35 180

  • Page 70

    Page 68 hv-wp/hw-wp series 18. Specification 3 9 0 743 530 1 1 0 ~150 70 440 786 45 4 5 3 0 0 h v - 2 0 0 k v - w p h w - 1 0 0 k v - wp h w - 2 0 0 k v - wp m o d e l s.

  • Page 71

    Hv-wp/hw-wp series page 69 19. Maintenance 19. Maintenance refer to "4. Caution" for use. Refer to "6.1. Display and symbols " and corresponding mode for displayed error code. Refer to "14. Calibration (adjusting the scale)" for precision weighing. Periodically check the accuracy of weighing. Calibr...

  • Page 72

    Page 70 hv-wp/hw-wp series memo.

  • Page 73

    Hv-wp/hw-wp series page 71 memo.

  • Page 74

    Page 72 hv-wp/hw-wp series memo.