A&D SJ-15KWP Instruction Manual

Manual is about: IP67 Compact Bench Scales

Summary of SJ-15KWP

  • Page 1

    Sj-3000wp sj-6000wp sj-15kwp sj-30kwp 1wm pd4002705a.

  • Page 2

    ? 2013 a&d company, limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in any form by any means without the written permission of a&d company, limited. The contents of this manual and the specifications of the instru...

  • Page 3

    1 contents 1. Safety precautions ..........................................................................2 2. Parts description..............................................................................3 3. Preparation ...............................................................................

  • Page 4

    2 1. Safety precautions all safety messages are identified by the following, “warning” or “caution”, of ansi z535.4 (american national standard institute: product safety signs and labels). The meanings are as follows: warning a potentially hazardous situation which, if not avoided, could result in d...

  • Page 5

    3 2. Parts description sealing diagrams screwdriver use this screwdriver to open or close the battery cover. Weighing pan bubble spirit level adjust the leveling feet so that the bubble is in the center of circle. Inner pan (abs) pan support the pan support can be removed at times such as when the s...

  • Page 6

    4 3. Preparation 3.1. Installing / exchanging batteries the batteries are not included with the product. Prepare 6 x “d” size (r20p or lr20) dry-cell batteries. When the mark is displayed, exchange the old batteries with new ones. 1. Loosen the screws for securing the battery cover using the provide...

  • Page 7

    5 4. Display and symbols 4.1. Display symbols symbol description stable turns on when the weight value is stable. Net ◄ turns on when the net weight is displayed. (the tare operation is in progress.) zero ◄ turns on when zero is displayed. Comparator leds turns on when the comparator results are dis...

  • Page 8

    6 4.2. Operations and functions of switches switch description when the scale is turned off: touch the switch to turn on the scale. The scale will be automatically set to zero (power-on zero). When the scale is turned on: touch and hold the switch to trun off the scale. Tap the switch to zero the sc...

  • Page 9

    7 object to be weighed weighing pan container tap touch & hold 5. Operation 5.1. Basic weighing operation 1. Touch the switch to turn the power on. All the symbols except the comparator leds are displayed. When the weight values becomes stable, the display turns off for a moment and displays zero (p...

  • Page 10

    8 the tare switch will tare the scale and subtract the weight to zero as a tare weight when the weight is a plus value. In this case the zero◄ and net◄ indicators turn on. (tare operation) at the zero point, the net weight display shows the tare weight in negative, and the zero◄ and net◄ indicators ...

  • Page 11

    9 6. Selecting a weighing unit 6.1. Storing the weighing unit 1. Touch the on/off switch while touching and holding the tare switch in order to display in the function setting mode. 2. Tap the units switch to display . 3. Tap the sample switch to display a unit. Tap the tare switch to activate or de...

  • Page 12

    10 7. Counting mode determines a unit weight (the weight of one piece) from a known sample quantity, and calculates how many pieces are on the weighing pan using the unit weight. The unit weight is maintained even if the power is turned off. 1. Tap the units switch to se lect “pcs”. (“pcs” = pieces)...

  • Page 13

    11 8. Comparator the scale has three-, five- and seven-level comparators. Each comparator mode compares the weight value against the preset limit values and outputs the results using leds (yellow / green / red). Note: when the unit is “lb-oz” or “tl”, this function can not be used. •five-level compa...

  • Page 14

    12 6: to compare stable data which are ≥+5d. D = minimum display in kg (refer to “13. Specifications”.) in the counting mode, “d” is equal to the minimum weight display of kg mode. 8.1. The formula to compare comparison is performed using the formula listed below and the results are output. Five-lev...

  • Page 15

    13 seven-level comparator mode (portion weighing mode) results comparison formula led display none displayed value -e ” ( no leds on) lolo (level 1) level 1 lower limit ≤ displayed value level 2 lower limit ( red led on) lo (level 2) level 2 lower limit ≤ displayed value level 3 lower limit ( yellow...

  • Page 16

    14 8.2. Entering the comparator values 1. In the weighing mode, touch and hold the units switch to enter the comparator value setting mode. 2. Enter the comparator values using the following switches. Units to shift the blinking digit to the right. Sample to increase the value of the blinking digit ...

  • Page 17

    15 9. Auto-tare the sj-wp series has an auto-tare function to be used with the comparator mode enabled. If the weight values are in the ok range of comparator limits and stable for a preset period of time, the scale will automatic 1 ally tare the weight and show zero. In some countries or areas, the...

  • Page 18

    16 10. Calibration adjusts the scale for accurate weighing. Calibrate the scale in the following cases. When the scale is first installed. When the scale has been moved. When the ambient environment has changed. For regular calibration. Note: the legal for trade models can not be re-calibrated if th...

  • Page 19

    17 tap the units switch to select an item and tap the tare switch to execute it. To exit from the calibration mode, touch the switch or press the cal switch. The scale turns the power off. 10.2. Gravity acceleration correction when the scale is first used or has been moved to another location, it sh...

  • Page 20

    18 10.3. Calibration using a weight prepare a weight, preferably a weight with the same value as the weighing capacity of the scale to be calibrated. Note that the calibration weight value can be changed. 1. Turn the power on and warm up the scale for at least half an hour. Change the function setti...

  • Page 21

    19 10.4. Restoring the calibration data to the factory set values if the gravity acceleration value or calibration data is changed unintentionally, restore those values to the factory set values, as follows. 1. Refer to “10.1. Calibration mode” to enter the calibration mode. The gravity acceleration...

  • Page 22

    20 11. Function settings the scale has function settings to specify the scale performance. The parameters set in the function settings are maintained even if the power is turned off. 11.1. Setting the parameters 1. Turn the power off. 2. Touch and hold the tare switch and touch the switch to turn th...

  • Page 23

    21 11.2. Restoring the function settings to the factory set values 1. Turn the power off. 2. Touch and hold the tare switch and touch the switch to turn the power on and to display the software version. Release the switch but continue to touch the tare switch until “ clrfno ” with “ no ” blinking is...

  • Page 24

    22 11.3. Function list item parameter description 0 auto power-off function disabled 1 turns off after 5 minutes 2 turns off after 10 minutes 3 turns off after 15 minutes 4 turns off after 30 minutes auto power-off function poff 5 turns off after 60 minutes turns the power off automatically 0 1/3,00...

  • Page 25

    23 item parameter description 0 five-level (result led blinks.) 1 five-level (result led lights.) 2 three-level (result led blinks.) 3 three-level (result led lights.) 4 seven-level (result led blinks.) comparator mode cp-l 5 seven-level (result led lights.) sets comparator mode 0 comparator disable...

  • Page 26

    24 12. Maintenance 12.1. Notes on maintenance do not disassemble the scale. Contact your local a&d dealer if the scale needs service or repair. Use the original packaging for transportation. Do not use organic solvents to clean the scale. Use a warm lint free cloth dampened with a mild detergent. Ca...

  • Page 27

    25 13. Specifications specifications model sj-3000wp sj-6000wp sj-15kwp sj-30kwp capacity 3kg 6kg 15kg 30kg 0.001 kg 0.002 kg 0.005 kg 0.01 kg 0.0005 kg* 0.001 kg* 0.002 kg* 0.005 kg* 0.0002 kg 0.0005 kg 0.001 kg 0.002 kg minimum display “d” 0.0001 kg 0.0002 kg 0.0005 kg 0.001 kg counting number of ...

  • Page 28

    26 other weighing units model sj-3000wp sj-6000wp sj-15kwp sj-30kwp capacity 3000 g 6000 g 15000 g 30000 g 1 g 2 g 5 g 10 g 0.5 g* 1 g* 2 g* 5 g* 0.2 g 0.5 g 1 g 2 g g minimum display 0.1 g 0.2 g 0.5 g 1 g capacity 6.6 lb 13 lb 33 lb 66 lb 0.002 lb 0.005 lb 0.01 lb 0.02 lb 0.001 lb* 0.002 lb* 0.005 ...

  • Page 29

    27 14. Gravity acceleration values of gravity at various locations amsterdam 9.813 m/s 2 manila 9.784 m/s 2 athens 9.807 m/s 2 melbourne 9.800 m/s 2 auckland nz 9.799 m/s 2 mexico city 9.779 m/s 2 bangkok 9.783 m/s 2 milan 9.806 m/s 2 birmingham 9.813 m/s 2 new york 9.802 m/s 2 brussels 9.811 m/s 2 ...

  • Page 30

    28 world map.

  • Page 32

    3-23-14 higashi-ikebukuro, toshima-ku, tokyo 170-0013, japan telephone: [81] (3) 5391-6132 fax: [81] (3) 5391-6148 a&d engineering, inc. 1756 automation parkway, san jose, california 95131, u.S.A. Telephone: [1] (408) 263-5333 fax: [1] (408)263-0119 a&d instruments limited unit 24/26 blacklands way,...