  • Page 1

    Digital blood pressure monitor model ua-651ble instruction manual original manuel d ’ instructions traduction manual de instrucciones traducción manuale di istruzioni traduzione bedienungsanleitung Übersetzung 使用手冊 翻譯 1wmpd4003018.

  • Page 2: Contents

    English 1 contents dear customers .......................................................................2 preliminary remarks.................................................................2 precautions ..............................................................................2 parts identific...

  • Page 3: Dear Customers

    English 2 dear customers congratulations on purchasing a state-of-the-art a&d blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manu...

  • Page 4: Contraindications

    English 3 wireless communication devices, such as home networking devices, mobile phones, cordless phones and their base stations, walkie-talkies can affect this blood pressure monitor. Therefore, a minimum distance of 3.3 meters should be kept from such devices. When reusing the device, confirm tha...

  • Page 5: Parts Identification

    English 4 parts identification systolic pressure diastolic pressure pulse rate heart mark battery indicator i.H.B. Symbol (irregular heartbeat symbol) pressure bar indicator display air hose arm cuff start button index air socket proper fit range artery position mark dc jack ac adapter plug air conn...

  • Page 6: Symbols

    English 5 symbols symbols that are printed on the device case symbols function / meaning standby and turn the device on. Sys. Systolic blood pressure in mmhg dia. Diastolic blood pressure in mmhg pul. Pulse per minute battery installation guide direct current type bf: device, cuff and tubing are des...

  • Page 7

    English 6 symbols function / meaning recommended action full battery the battery power indicator during measurement. Low battery the battery is low when it blinks. Replace all batteries with new ones when the mark blinks. Unstable blood pressure due to movement during measurement. Take another measu...

  • Page 8: Using The Monitor

    English 7 using the monitor installing / changing the batteries 1. Remove the battery cover. 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+) and (-) are correct. 3. Replace the battery cover. Use only lr6, r6p or aa bat...

  • Page 9: Using The Monitor

    English 8 using the monitor wireless function caution in the unlikely event that this monitor causes radio wave interference to a different wireless station, change the location where this monitor is used or stop use immediately. Be sure to use in a location where visibility between the two devices ...

  • Page 10: Using The Monitor

    English 9 using the monitor pairing a bluetooth® device needs to be paired with a different specific device in order to communicate with that device. If this monitor is paired with a receiver device from the start, measurement data is transmitted automatically to the receiver device each time a meas...

  • Page 11: Using The Monitor

    English 10 using the monitor communication distance the communication distance between this monitor and the receiver device is about 10 m. This distance is reduced by the conditions in the surrounding environment, so be sure to check that the distance is short enough for a connection to be made afte...

  • Page 12: Using The Monitor

    English 11 using the monitor selecting the correct cuff size using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuf...

  • Page 13: Using The Monitor

    English 12 do not roll up shirtsleeve tightly 1 to 2 cm air hose cuff index and proper fit range artery position mark secure the fabric fastener firmly using the monitor applying the arm cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown. Place the cuff ...

  • Page 14: Measurements

    English 13 measurements before measurement, read “notes for accurate measurement” on the next page. Normal measurement 1. Place the cuff on the arm (preferably the left arm). Sit quietly during measurement. 2. Press the start button. All of the display segments are displayed. Zero is displayed blink...

  • Page 15: Measurements

    English 14 measurements measurement with the desired systolic pressure model ua-651ble is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. If re-inflation occurs repeatedly or your systolic blood pressure is expected to exceed 230 mmhg, use the followi...

  • Page 16: Pressure Bar Indicator

    English 15 what is an irregular heartbeat the ua-651ble blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressur...

  • Page 17: About Blood Pressure

    English 16 reference material: journal of hypertension 1999, vol 17 no.2 mmhg 110 105 100 95 90 85 80 optimal 120 130 140 150 160 170 180 systolic blood pressure mmhg normal high-normal grade 1 hypertension (mild) grade 2 hypertension (moderate) grade 3 hypertension (severe) dia stolic bl ood pre ss...

  • Page 18: Troubleshooting

    English 17 typical fluctuation within a day (measured every five minutes) pm am time bloo d pre ssure systolic diastolic sleep described in this manual to get to know your normal blood pressure. Regular readings give a more comprehensive blood pressure history. Be sure to note date and time when rec...

  • Page 19: Maintenance

    English 18 maintenance do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, request service from your dealer or from the a&d service group. The a&d service group will prov...

  • Page 20

    English 19 useful life device: 5 years (when used six times a day) cuff: 2 years (when used six times a day) ingress protection device: ip20 accessory ac adapter the adapter is to connect the blood pressure monitor to a power source at home. Tb-233 please contact your local a&d dealer for purchasing...

  • Page 21

    1-243 asahi, kitamoto-shi, saitama 364-8585 japan telephone: [81] (48) 593-1111 fax: [81] (48) 593-1119 a&d instruments limited unit 24/26 blacklands way, abingdon business park, abingdon, oxfordshire ox14 1dy united kingdom telephone: [44] (1235) 550420 fax: [44] (1235) 550485 a&d engineering, inc....