A&D UA-767F Instruction Manual

Manual is about: Digital Blood Pressure Monitor

Summary of UA-767F

  • Page 1

    Digital blood pressure monitor model ua-767f instruction manual original manuel d’instructions traduction manual de instrucciones traducción manuale di istruzioni traduzione 使用手冊 翻譯 1wmpd4002780c.

  • Page 2: Contents

    English 1 contents dear customers.................................................................... 2 preliminary remarks ............................................................. 2 precautions........................................................................... 2 parts identification......

  • Page 3: Dear Customers

    English 2 dear customers congratulations on purchasing a state-of-the-art a&d blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manu...

  • Page 4: Contraindications

    English 3 used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations. When the ac adapter is used, make sure that the ac adapter can be readily removed from the electrical outlet when necessary. Do not modify...

  • Page 5: Parts Identification

    English 4 parts identification battery compartment display air hose arm cuff dc jack air connector plug air socket who classification indicator and pressure bar indicator memory systolic pressure diastolic pressure pulse rate battery indicator heart mark 1.5v batteries (r6p, lr6 or aa) date & clock ...

  • Page 6: Symbols

    English 5 symbols symbols that are printed on the device case symbols function / meaning standby and turn the device on. Sys. Systolic blood pressure in mmhg dia. Diastolic blood pressure in mmhg pul. Pulse per minute battery installation guide direct current type bf: device, cuff and tubing are des...

  • Page 7: Symbols

    English 6 symbols symbols function / meaning recommended action appears during measurement when the cuff is attached loosely the reading may yield an incorrect value. Apply the cuff correctly, and take another measurement. Detected rate of ihb in memory user previous measurements stored in memory. A...

  • Page 8: Operation Mode

    English 7 operation mode 1. Normal measurement press the start button. Blood pressure is measured and the data is stored in memory. This device can store the last 60 measurements for each of the four user in memory. 2. Recalling the data press the or button to recall the data in memory. The average ...

  • Page 9: Operation Mode

    English 8 operation mode 4. Deleting data stored in memory in standby, press both the and buttons. The mark, battery indicator and user mark will appear. When you would like to delete the memory data of the currently displayed user, press and hold both the and buttons until the illuminated mark star...

  • Page 10: Using The Monitor

    English 9 using the monitor installing / changing the batteries 1. Remove the battery cover. 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+ and -) are correct. Use only r6p, lr6 or aa batteries. 3. Attach the battery co...

  • Page 11: Using The Monitor

    English 10 using the monitor adjusting the built-in clock adjust the clock prior to use. 1. Press and hold the set button until the year starts blinking. 2. Select the year using the or button. Press the set button to set the current year and move to month/day selection. The date can be set anywhere...

  • Page 12: Using The Monitor

    English 11 using the monitor selecting the correct cuff size using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuf...

  • Page 13: Using The Monitor

    English 12 using the monitor symbols that are printed on the cuff symbols function / meaning recommended action artery position mark set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm. ▲ index ref catalog number proper fit range for the adult cuff. I...

  • Page 14: Using The Monitor

    English 13 using the monitor how to take proper measurements for the most accurate blood pressure measurement: sit comfortably on a chair. Rest your arm on the table. Do not cross your legs. Keep your feet on the floor and straighten your back. Relax for about five to ten minutes before measurement....

  • Page 15: Measurements

    English 14 measurements before measurement, read “notes for proper measurement” on the next page. Normal measurement 1. Press the set button to select a user from 1 to 4. 2. Place the cuff on the arm (preferably the left arm). Sit quietly during measurement. 3. Press the start button. All of the dis...

  • Page 16: Measurements

    English 15 measurements measurement with the desired systolic pressure model ua-767f is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. Use this method when re-inflation occurs repeatedly or when the results are not displayed even if the pressure decr...

  • Page 17: Recalling The Memory Data

    English 16 recalling the memory data note: this device stores the last 60 measurements for each of the four user in memory. 1. Press the or button. The average of all measurements and the number of data are displayed. (if no data, “0” is displayed. Press the , or start button to turn the device off....

  • Page 18

    English 17 4. Press the set button to display the memory display after changing the user number. 5. Press the start button to turn the device off. After one minute of non-operation, the device will turn off automatically. User 1 user 3 user 2 user 4.

  • Page 19: Ihb

    English 18 what is an irregular heartbeat the ua-767f blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure ...

  • Page 20: Pressure Bar Indicator

    English 19 pressure bar indicator the indicator monitors the progress of pressure during measurement. Who classification indicator each segment of the bar indicator corresponds to the who blood pressure classification described on the next page. Who classification indicator severe hypertension moder...

  • Page 21: About Blood Pressure

    English 20 about blood pressure what is blood pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmhg). On...

  • Page 22: Troubleshooting

    English 21 described in this manual to get to know your normal blood pressure. Regular readings give a more comprehensive blood pressure history. Be sure to note the date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data. Troubleshooting problem p...

  • Page 23: Maintenance

    English 22 maintenance do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, contact the authorized dealer in your area or our customer service department. The a&d customer...

  • Page 24

    English 23 applied part cuff type bf useful life device: 5 years (when used six times a day) cuff: 2 years (when used six times a day) accessory ac adapter the adapter is to connect the device to a power source at home. Please contact your local a&d dealer for purchasing. The ac adapter is required ...

  • Page 25: Memo

    English 24 memo.

  • Page 26

    1-243 asahi , kitamoto-shi, saitama 364-8585, japan telephone: [81] (48) 593-1111 fax: [81] (48) 593-1119 a&d instruments limited unit 24/26 blacklands way, abingdon business park, abingdon, oxfordshire ox14 1dy united kingdom telephone: [44] (1235) 550420 fax: [44] (1235) 550485 a&d engineering, in...