A&D UB-512 Instruction Manual

Other manuals for UB-512: Instruction Manual, Instruction Manual
Manual is about: Wrist Digital Blood Pressure Monitor

Summary of UB-512

  • Page 1

    Wrist digital blood pressure monitor model ub-512 instruction manual manuel d’instructions manual de instrucciones manuale di istruzioni 使用手冊 1wmpd4000980c original traduction traducción traduzione 翻譯.

  • Page 2: Contents

    English 1 contents dear customers............................................................................................................................... 2 preliminary remarks ........................................................................................................................

  • Page 3: Dear Customers

    English 2 dear customers congratulations on purchasing a state-of-the-art a&d blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this device will facilitate your daily blood pressure regimen. We recommend that you read through this manua...

  • Page 4

    English 3 used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations. When reusing the device, confirm that the device is clean. Do not modify the device. It may cause accidents or damage to the device. To me...

  • Page 5: Parts Identification

    English 4 parts identification display systolic pressure diastolic pressure pulse rate battery cover start button carrying case alkaline batteries (lr03 or aaa) cuff part of display memory systolic pressure diastolic pressure pulse rate i.H.B indicator (irregular heartbeat indicator) battery indicat...

  • Page 6: Symbols

    English 5 symbols symbols function / meaning recommended action standby and turn the device on battery installation guide direct current sn serial number date of manufacture type bf: device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appe...

  • Page 7

    English 6 symbols function / meaning recommended action sys systolic blood pressure in mmhg dia diastolic blood pressure in mmhg pul./min pulse per minute ec directive medical device label weee label manufacturer eu-representative refer to instruction manual/booklet.

  • Page 8: Using The Monitor

    English 7 using the monitor 1. Installing / changing the batteries 1. Slide the battery cover as shown to remove it from the device. 2. Insert two aaa / lr03 size batteries into the battery compartment as shown, taking care that the polarities (+ and -) are correct. 3. Slide the battery cover back o...

  • Page 9: Using The Monitor

    English 8 using the monitor 3. How to take accurate measurements for the most accurate blood pressure measurement: • sit comfortably on a chair. Rest your arm on the table. Do not cross your legs. Keep your feet on the floor and straighten your back. • relax for about 5 to 10 minutes before measurem...

  • Page 10: Measurements

    English 9 measurements note: model ub-512 can store the last thirty sets of data for each button. We recommend that if two people regularly use the device, one uses the start 1 button and the other uses start 2 button, to prevent confusion over stored data. Normal measurement with storing data 1. Si...

  • Page 11: Measurements

    English 10 measurements notes for accurate measurement sit down in a comfortable position. Place the arm to be used for the measurement on a table or other support so that the center of the cuff will be at the same height as your heart. Relax for about five to ten minutes before taking a measurement...

  • Page 12: Pressure Bar Indicator

    English 11 3. Clearing data remove batteries to clear all data. Re-install them again. 4. Unrecorded measurement (guest mode) press both of the start 1 and start 2 buttons at once. An unrecorded measurement is started. What is an irregular heartbeat? Model ub-512 blood pressure monitor provides a bl...

  • Page 13: Who Classification Indicator

    English 12 who classification indicator each six segments of the bar indicator correspond to the who blood pressure classification described on the next page. About blood pressure what is blood pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressur...

  • Page 14

    English 13 to prevent hypertension or keep it under control: do not smoke exercise regularly reduce salt and fat intake have regular physical checkups maintain proper weight why measure blood pressure at home? Blood pressure measured at a clinic or doctor's office may cause apprehension and can prod...

  • Page 15: Troubleshooting

    English 14 troubleshooting problem possible reason recommended action batteries are drained. Replace all batteries with new ones. Nothing appears in the display, even when the power is turned on. Battery terminals are not in the correct position. Reinstall the batteries with negative and positive te...

  • Page 16: Maintenance

    English 15 maintenance do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, request service from your dealer or from the a&d service group. The a&d service group will prov...

  • Page 17

    1-243 asahi, kitamoto-shi, saitama 364-8585 japan telephone: [81] (48) 593-1111 fax: [81] (48) 593-1119 a&d instruments limited unit 24/26 blacklands way, abingdon business park, abingdon, oxfordshire ox14 1dy united kingdom telephone: [44] (1235) 550420 fax: [44] (1235) 550485 a&d engineering, inc....