A.J.Antunes UF-216C Series Owner's Manual - page 11
UF-216 WATER FILTRATION SYSTEM
10
P/N 1010885 07/04
UF-216 WATER FILTRATION SYSTEM
11
P/N 1010885 07/04
INSTALLATION (continued)
Refer to the figure to the right and follow the Steps
below to install and flush the Carbon Cartridge.
1. Shut off the water to the system using the inlet
water valve.
2. Open the tap or faucet closest downstream to the
filter system to relieve pressure in the system.
3. Unscrew the Carbon Filter Housing, remove the
old Carbon Filter and discard any water inside the
housing.
4. Remove the plastic wrap and labels from the new
carbon cartridge. Make sure the rubber gaskets
are in place on both ends of the Carbon Cartridge
before inserting into the Carbon Filter Housing.
Place the Carbon Cartridge into the Housing and
screw the Housing up into the Filter Housing Cap
5. Slowly open the inlet water valve and allow water
to enter the system.
6. Water should flow through the system and out of
the open tap. Allow water to flow out of the tap
for at least 5 minutes at maximum flow rate. After
5 minutes of flushing, close the tap.
7. Press and hold the Start button for at least 30
seconds to flush air out of the center of the hollow
fibers of the membrane cartridge.
8. Release the Start button. Flushing of the system
is complete.
SANITIZING THE SYSTEM AND LINES
O-Ring
Rubber Gasket
Rubber Gasket
Carbon Filter
Cartridge
Carbon Filter
Housing
Filter Housing
Cap