A.O. Smith AOSRE50100 Owner's Manual

Manual is about: A. O. Smith OWNER'S MANUAL Electric Water Heater

Summary of AOSRE50100

  • Page 1

    1 electric keep this manual in the pocket on heater for future reference whenever maintenance adjustment or service is required. Part no. 184551-000 supersedes part no. 183795-000 general safety information caution text printed or outlined in red contains information relative to your safety. Please ...

  • Page 2

    2 uprights point of use heaters table tops figure 1 install vacuum relief in cold water inlet line as required by local codes. Install suitable drain pans under heaters to prevent damage due to leakage. Refer to water heater location on page 3. Install thermal expansion tank or device if water heate...

  • Page 3

    3 installation warning for california installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or calif...

  • Page 4

    4 wiring diagrams danger: turn off the heater electrical supply before servicing any electrical components. C-2 standard single element 240 volt c-2 standard single element 120 volt a-3 240 volt “off peak” non-simultaneous operation bottom element on separate time clock or “off peak” meter *note: so...

  • Page 5

    5 operation caution never operate the heater with the cold water inlet valve closed or without filling with water per the filling instructions. Failure to do so will cause damage and can void element warranty. Filling 1. Close the water heater drain valve. (turn clockwise ). 2. Open a nearby hot wat...

  • Page 6

    6 maintenance electric water heater maintenance consists of cleaning the tank bottom and removing scale from the heating elements. Your dealer should be contacted for tank and element cleaning. In some instances a hissing sound may be heard as the scale builds up. This noise is normal although the s...

  • Page 7

    7 installing the point of use water heater (see page 2 for typical installations) optional wall mounting warning wall construction at the point of the water heater installation must be capable of supporting at least 200 pounds. As an example: if the water heater is to be installed on a wall of gypsu...

  • Page 8

    8 wiring diagrams danger turn off the heater electrical supply before servicing any electrical components. Optional cord set wiring (120 volt and 240 volt) there may be a cord set supplied with the water heater at the time of manufacture. If not, one can be ordered through the parts department, see ...

  • Page 9

    9 point of use water heater operation caution never operate the heater with the cold water inlet valve closed or without filling with water per the filling instructions. Failure to do so will cause damage and can void element warranty. Filling 1. Close the water heater drain valve. (turn clockwise )...

  • Page 10

    10 leakage checkpoints instructions: use this illustration as a guide when checking for sources of water leakage. You or your dealer may be able to correct what appears to be a problem. Water on the side of the tank may be condensation due to the panel or insulation not being in place. Drain valve l...

  • Page 11

    11 limited residential electric warranty this warranty is applicable to the original owner only. If the glass lined tank in this water heater shall prove upon examination by a. O. Smith corporation (the warrantor) to have leaked during the warranty period in normal residential use, due to natural co...

  • Page 12

    12 5621 w. 115th street • alsip, illinois 60803 phone: 1-800-433-2545 • fax: 1-800-433-2515 www.Hotwater.Com / email: parts @hotwater.Com.