A.O. Smith Epsilon EB-40 User manual

Other manuals for Epsilon EB-40: Installation And Service Manual
Manual is about: Light Commercial High Efficiency Condensing Boiler

Summary of Epsilon EB-40

  • Page 1

    8g.52.9000/10.1 1 changes reserved e.&o.E. 0310 350 innovation has a name. Light commercial high efficiency condensing boiler eb - 40/50 epsilon user manual.

  • Page 2: Content

    2 user manual epsilon-series content introduction ........................................................ 3 safety ................................................................ 5 description of the boiler ..................................... 6 explanation of the function keys and display..... 7...

  • Page 3: Introduction

    3 user manual epsilon-series these operating instructions describe the func- tioning and the operating of the a.O. Smith epsi- lon boilers. This manual is for the end user. For installation and servicing there is an installation & servicing instructions manual for the installer. Read this manual ful...

  • Page 4

    4 user manual epsilon-series please ensure that the installer that you have received a full and clear explanation of its opera- tion. The installer is legally required to complete a commissioning checklist as a means of com- plying with the appropriate building regulations (england and wales). This ...

  • Page 5: Safety

    5 user manual epsilon-series the device may be operated only by authorized persons who have been instructed on the operation and use of the device. Improper use may cause damage to the device and / or to the connected installation. The appliance is not to be used by children or persons with reduced ...

  • Page 6: Description of The Boiler

    6 user manual epsilon-series the epsilon boiler is a room sealed, condensing and modulating central heating boiler. The boiler is provided with a compact stainless steel heat exchanger with smooth tubes. A well thought out principal using durable materials. The boiler burns gas for supplying warmth....

  • Page 7: The Reset Key

    7 user manual epsilon-series on/off key central heating. When 'on' the indication l.E.D. Is illuminated. On/off key domestic hot water (dhw) when 'on' the indication l.E.D. Is illuminated. On/of key pump programm. Continuously yes/no when 'on' the indication l.E.D. Is illuminated. In most situations...

  • Page 8: The Boiler Display

    8 user manual epsilon-series the boiler display the reading of the boiler display can be done in two ways. The good reading during this reading the display will only show what is necessary. Under normal circumstances the display will give a good reading. If a fault is detected the boiler will be blo...

  • Page 9

    9 user manual epsilon-series water pressure in the central heating system the installation will function optimally with a water pressure of between 1,5 and 1,7 bar. If the water pressure drops below 1 bar, the display will show fill. During this message the boiler will remain functioning at a reduce...

  • Page 10

    10 user manual epsilon-series replenishing the central heating system the central heating installation needs to be filled with potable (drinking) wa- ter. For topping up the installation you use the filling loop according to the following procedure: (if in any doubt please contact your dealer) 1. Sw...

  • Page 11: Turning The Boiler Off

    11 user manual epsilon-series holiday period: adjust the thermostat to the holiday period. See the user thermostat manual. The hot water facility can be switched off by means of the program key on the control panel. Re-setting the central heating system: switch off the three program keys , , when th...

  • Page 12

    12 user manual epsilon-series error, maintenance and warranty if a fault is detected the boiler will be blocked. This will be reflected, by an alternate display of good, with an e of error or a bl of blocking and a number code. You can try to reset the boiler by pressing the reset key once. If the p...

  • Page 13: Adjustments

    13 user manual epsilon-series adjustments the boiler has a large number of settings options. We advise you to contact your installer for adjus- ting the boiler to the required settings. Adjusting the flow water temperature (ch) - press the mode key briefly (from the technical reading). The display w...

  • Page 14

    14 user manual epsilon-series selection type of installation flow water temperature 01 radiators; air heating; convectors 85°c 02 radiators with large surface areas or under floor heating as additional heating 70°c 03 under floor heating with radiators as additional heating 60°c 04 full under floor ...

  • Page 15

    15 user manual epsilon-series.

  • Page 16: Your Installer

    A.O. Smith uk, unit b8 amstrong mall, southwood business park, farnborough, hampshire gu14 0nr www.Aosmith.Co.Uk “a.O. Smith water heaters” is a trading name of advance services (sales) ltd. Reg. Your installer.