AA Portable Power Corp Universal Smart Charger User Manual - Detail Picture
•
High Efficiency: 85-95%
•
MTBF (Mean Time between Failure): 50,000 POH (Power on Hour) = 10 years of everyday
operation of 8 hours
•
UL / CE listed
Charging cycle:
Stage 1: Constant Current Mode (CC):
The charger changes to constant current
18
A+/-0.5A. When the
battery voltage reaches up to
54-75
VDC (Based on voltage selection),
the charging stage changes from CC (Constant Current) to CV
(Constant Voltage) mode.
Stage 2: Constant Voltage Mode (CV):
In this stage the voltage of each cell in the battery is
equalized. The charger holds the battery at
54-75
VDC (Based on
voltage selection) and the current slowly reduces.
Detail Picture
Charging Voltage (VDC) switch position
Charging Current switch position AC Power Cord DC Charge Power Cord
LED 2 LED 1
115VAC / 230VAC input voltage switch
(Always set to 115VAC postion)
Adjustable charging voltage setting switch