    Please retain this guide for future reference operating & installation manual bk061 en 13240:2001+ amd. A2:2004 rev 05 august 2009 part no. Afs1363 09 range of stoves.

  • Page 2: 0844 847 5107

    Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our ecoburn range to ensure ultimate performance and years of trouble free use and enjoyment. Every detail of the stove has been carefully designed and engineered which is why we are...

  • Page 3

    Contents aarrow ecoburn stoves page no. Introduction warning notice 4 safety notices 5 the principle of the stove 5 check list 6-7 data plate information 7 technical data 8 installation general precautions 9 handling 9 hearth 9 combustible materials 9 air for combustion 9 fitting the flue outlet & h...

  • Page 4: Warning

    Warning it is a legal requirement that the installation of all new or replacement, wood or solidfuel heating appliances are required to obtain building control approval from your local authority or the installation work must be carried out through a government approved competent persons scheme such ...

  • Page 5

    Safety a fireguard conforming to bs 8423:2002 should be used in the presence of children and old or infirm people. Please note, this appliance should be used with the fire door closed at all times except when re-fuelling or de-ashing. Do not use aerosol sprays or any other flammable materials near t...

  • Page 6

    Check list 6 inside the appliance body you should find the following: part description & visual aid (not to scale) aarrow ecb 5 aarrow ecb 7 aarrow ecb 9 aarrow ecb 11 1. Fuel retainers 2 2 2 2 2. Throat plate 1 1 1 1 3. Flue spigot 1, ( 4" ) 1, ( 5" ) 1, ( 5" ) 1, ( 6" ) 4. Hot plate 1, ( 4" ) 1, (...

  • Page 7

    Check list inside the appliance you should find the following : aarrow ecoburn stoves 7 description & visual aid (not to scale) aarrow ecb 5 aarrow ecb 7 aarrow ecb 9 aarrow ecb 11 8. Side liners 2 2 2 2 9. Rear liners 1 2 2 2 10. Wood burning tray 1 1 1 1 11. Stove mitten ( hot glove) 1 1 1 1 14. F...

  • Page 8

    8 technical data technical data aarrow ecb 5 aarrow ecb 7 aarrow ecb 9 aarrow ecb 11 nominal heat output (kw) 5.1 6.1 8.8 11 efficiency nett (%) 74.7 72.1 71.6 74.7 mean flue gas temperature (c) 306 363 364 370 mean co emission @ 13% o2 (%) 0.58 0.58 0.68 0.71 flue mass gas flow (g/s) 4.4 4.9 6.9 6....

  • Page 9

    General precautions note : all local regulations, including those referring to national and european standards need to be complied with, when installing the appliance. The building regulations for england and wales 2000 ref approved document j 2002 edition (issued by the dtlr). The building standard...

  • Page 10

    Fitting the flue outlet and hot plate the flue outlet spigot is found packed inside the appliance . The hot plate (blanking plate) is sup- plied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cement on the mateing faces of the f...

  • Page 11

    Aarrow ecoburn stoves 11 installation due to the gradual introduction of europe chimney standards chimneys will be specified according to their performance designation as defined in bs en 1443 that covers the general requirements for chimneys. The minimum performance designation required for use wit...

  • Page 12: Note -

    Aarrow ecoburn stoves 12 installation note - under no circumstances should this appliance be connected to a shared flue system, that serves any other heating appliance. Typical rear flue outlet (as per bs 8303-1) maximum 150mm (6”) horizontal flue section minimum 150mm (6”) diameter flue soot door f...

  • Page 13

    Installation aarrow ecoburn stoves 13 plan view of register plate and clearances for non insulated flues (plan view of steel register plate, 1.5mm thick minimum ) non combustible register plate. Minimum 1.5mm thick steel. Typical top flue outlet (as per bs 8303-1) typical metal insulated chimney sys...

  • Page 14

    Adjusting the self levelling feet the aarrow ecoburn stoves are equipped with adjustable rear levelling feet, these are ideal for use where the hearth surface is not flat or level. Adjustment is as follows : position the stove on the hearth into its final resting place, ensuring room for the flue co...

  • Page 15

    15 aarrow ecoburn stoves installation final check list before handing over the installation to the customer it is a requirement under document j that the appliance is lit and the functioning of the chimney system is checked for satisfactory operation. Be sure that the chimney is operating and all sm...

  • Page 16

    Building control consent checklist hearths, fireplaces, flues and chimneys this checklist is to ensure heaths, fireplaces, flues and chimneys are satisfactory, and show what you have done to comply with the requirements of the building regulations 2000 approved document j 2002 1. Building address wh...

  • Page 17

    Annual maintenance it is important that your appliance is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following : cleaning important; under some circumstances soot can quickly build up on the t...

  • Page 18

    Aarrow ecoburn stoves 18 service & maintenance summer storage / non usage please ensure that your stove is left clean and moving components are well lubricated for the summer months (during periods of prolonged non use). If possible store the throat plate outside of the stove, check all moveable com...

  • Page 19

    Service & maintenance 19 aarrow ecoburn stoves fire door rope replacement periodically, visually check over the fire door rope seal for any damage, cuts or tears and any detached sections. The rope gasket can be replaced, using the universal rope kit (see spare parts guide page 32), please follow th...

  • Page 20

    Aarrow ecoburn stoves 20 service & maintenance please note — this should be carried out when the fire is cold and unlit. Fire door primary air inlet once a year inspect the primary air inlet assembly located at the base of the fire door. Lift the door assembly from the stove body and place on a leve...

  • Page 21

    Service & maintenance should you have any questions about your aarrow ecoburn stove that are not covered in this manual please contact your aarrow dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service rec...

  • Page 22

    Aarrow ecoburn stoves 22 operating instructions fuel types safety notice the most efficient use of this appliance is with the fire door(s) closed at all times, apart from re-fuelling (when alight) or cleaning (when cold). Never leave the appliance unattended for an extended length of time with the d...

  • Page 23

    Operating instructions 23 aarrow ecoburn stoves burning wood set the fire; by using rolled up newspaper and lay a layer of dry kindling wood on top of this. Use 2 or 3 fire lighters to light the kindling. Set the primary air and air wash controls to fully open position. See page 26. After the kindli...

  • Page 24

    Aarrow ecoburn stoves 24 operating instructions over firing & chimney fires do not over fire your appliance. Using flammable liquids or too much wood or firing the stove at maximum for prolonged periods may result in over- firing. If the chimney connector or casing glows red the appliance is being o...

  • Page 25

    25 aarrow ecoburn stoves operating instructions air inlet controls the aarrow ecoburn stoves have two air inlet controls. The primary air inlet providing under draught to the base of the fire chamber through the control slider located under the oval at the base of the fire door. The air wash system,...

  • Page 26

    Operating instructions aarrow ecoburn stoves 26 multi purpose operating tool your aarrow ecoburn stove is supplied with a multi purpose operating tool, used for adjusting the air inlet controls and the removal of the ash pan ( see fig. 17 ) to empty the ash pan the ecoburn stoves are supplied with a...

  • Page 27

    27 aarrow ecoburn stoves operating instructions main fire door handle a stove mitten is supplied with your aarrow ecoburn stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas o...

  • Page 28

    Optional extra / accessories aarrow ecoburn stoves part description visual aid (not to scale) aarrow ecb 5 aarrow ecb 7 aarrow ecb 9 aarrow ecb 11 afs 101a afs 101a afs 101a afs101a aib 0 aib 8 aib 9 aib 10 afs1135 afs1135 afs1135 afs1135 afs1305 afs1305 afs1305 afs1305 28 aerosol touch up paint got...

  • Page 29

    Spare parts list aarrow ecoburn stoves part description visual aid (not to scale) aarrow ecb 5 aarrow ecb 7 aarrow ecb 9 aarrow ecb 11 throat plate afs1286 afs1287 afs1288 afs1289 flue spigot afs009a afs009 afs009 afs011 hot plate afgs009b afs009 afs009 afs012 rear liner(s) afs1207 afs1210 afs1213 a...

  • Page 30

    Spare parts list 30 part description visual aid (not to scale) aarrow ecb5 aarrow ecb7 aarrow ecb9 aarrow ecb11 operating tool afs008 afs008 afs008 afs008 afs1214 afs1215 afs1216 afs1216 afs1365 afs1365 afs1365 afs1365 hinge & fixing kit afs047 afs047 afs047 afs047 afs1021 afs1021 afs1021 afs1021 af...

  • Page 31

    Spare parts list aarrow ecoburn stoves part description visual aid (not to scale) aarrow ecb5 aarrow ecb7 aarrow ecb9 aarrow ecb11 afs1285 afs1285 afs1285 afs1285 afs1368 afs1369 afs1369 afs1369 afs1405 afs1405 afs1405 afs1405 afs 1196 afs 1197 afs 1198 afs 1483 31 replacement stove mitten ( hot glo...

  • Page 32

    32 guarantee guarantee once again we would like to thank you for buying an aarrow ecoburn stove. When you buy an aarrow stove , you are not only buying a first class appliance you are buying a commitment from us to look after you and your appliance for as long as you want. Your ecoburn stove comes w...

  • Page 33: Lifetime Guarantee

    33 aarrow ecoburn stoves aarrow stoves gives a lifetime guarantee against manufacturing defects of the main body* of its ecoburn range of stoves. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not ...

  • Page 34: I’Ve Checked It

    Bk061 final factory check list stove model …………….……………… serial no. ………………………………. I’ve checked it and its o.K ! Quality / finish parts wood tray flue outlet hot plate fuel retainers x 2 firebox liners throat plate door catch/nickel door handle convector kit fixings x 4 ash pan adjusting feet x 2 oper...