Aarow Nouveau 7 Operating & Installation Manual

Manual is about: Multifuel Stove

Summary of Nouveau 7

  • Page 1

    Nouveau 7 multifuel stove operating & installation manual please retain these instructions for future reference nouveau 7 multifuel stove rev 2 august 2004 afs1120

  • Page 2: Lifetime Guarantee

    Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our nouveau family to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so conf...

  • Page 3

    Introduction page safety notices 5 the principle of the fire 5 check list 6 technical data 7 operating instructions firebox linings and throat plate removal 8 airwash system 8-9 interlock 9 multi-purpose operating tool 9 door trim 9 fire door glass 9-10 door adjustment 10 fuels 11 lighting the fire ...

  • Page 4: Warning

    Warning to all multifuel users petroleum coke some of whose brand names are "calco", "petrocoke" or "wonderco" must not be burned in this appliance to use these fuels will invalidate the appliance guarantee if in doubt contact the solid fuel association telephone number 0800 600 000 www.Solidfuel.Co...

  • Page 5

    Nouveau 7 multifuel stoves 5 introduction safety a fireguard conforming to bs 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to bs 3248 should be fitted. Do not use aerosol sprays or any other...

  • Page 6

    Inside the appliance you should find the following: 6 nouveau 7 multifuel stoves check list part description & visual aid (not to scale) nouveau 7 multifuel 1. Grate bars 5 2. Fuel retainers 2 3. Throat plate 1 4. Flue spigot 1(5”) 5. Hot plate 1(5”) 6. Ashpan 1 7. Operating tool 1 8. Rear liners 2 ...

  • Page 7

    Nouveau 7 multifuel stoves 7 technical data room min/max room heater only output (kw) 1.5 - 7 technical data nouveau 7 multifuel room heater with domestic hot water with add in boiler type 1 2 max output to room (kw) max output to water (kw) 4.4 3 2.6 4 height (mm) 620 width (mm) 476 depth (mm) 365 ...

  • Page 8

    Firebox linings & throat plate the nouveau 7 multifuel stoves firebox has reflective liners to the sides and rear) and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these. Multifuel grate the aarrow multifuel grate comprises of...

  • Page 9

    Interlock system nouveau fires are fitted with an "interlock" system. A situation where the fire door is closed and the ash door is open may lead to serious over firing which could damage the appliance. Correct use of the doors and interlock system will ensure that this does not happen. Operation is...

  • Page 10

    Door adjustment the catch can be adjusted by sharply tapping the catch on the inside of the door. Nouveau 7 multifuel stoves are fitted with bolt on hinges. These should not normally require adjustment. However if the seal of the alignment seal of the doors does require adjustment the procedure is a...

  • Page 11

    Fuel types wood- any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case o...

  • Page 12

    Ensure that you have read & understood these instructions before lighting the fire. Always wear suitable protective fire gloves when refuelling your stove. Solid fuel burning •set the grate to ‘coal’ position. •ensure that the ash pan is in position and the fire doors are closed. •set the air wash t...

  • Page 13

    Ash removal the ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan. On no account should the ash be allowed to build up to touch the grate as this will greatly shorten its life. De - ashing it is necessary to maintain an ash layer on the upper surf...

  • Page 14

    Annual maintenance it is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following. Remove the firebricks lining and throat plate, inspect all gaskets on doors, glass et...

  • Page 15

    Nouveau 7 multifuel stoves 15 accessories accessories paint matching aerosol paint to tone in any connecting flues, pipes or surrounding metalwork. Add in boilers for further information on add in boilers see page 23. Interchangeable canopies •to fit the interchangeable canopy (fig. 7): remove the f...

  • Page 16

    16 nouveau 7 multifuel stoves installation general precautions note - all installations must conform to the appropriate building regulations. The building regulations for england and wales 2000 ref approved document j 2002 edition (issued by the dtlr). The building standards (scotland) (consolidatio...

  • Page 17

    Nouveau 7 multifuel stoves 17 installation firebox liner panels the nouveau 7 multifuel stoves use firebox liner panels to the base, sides and back. The nouveau 7 multifuel stoves have reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should com...

  • Page 18

    Multifuel grate grate the grates in the nouveau multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "h" sitting on the high sections of t...

  • Page 19

    Nouveau 7 multifuel stoves 19 installation fitting the flue outlet and hot plate the flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cem...

  • Page 20

    Due to the gradual introduction of european chimney standards chimneys will be specified according to their performance designation as defined in bs en 1443 that covers the general requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is t450 ...

  • Page 21

    Nouveau 7 multifuel stoves 21 installation.

  • Page 22

    22 nouveau 7 multifuel stoves installation p lan v iew of register plate and clearances for non insulated flues t ypical m etal i nsulated c himney s ystem t o be installed to the chimney manufacturers instructions in compliance with building regulations and bs7566 p ts 1-4 a is minimum clearance fo...

  • Page 23

    Nouveau 7 multifuel stoves 23 installation add in boilers nouveau 7 multifuel stoves offer the option of a cantilever boiler or a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •remove the fuel retainers, rear firebox liner panels and throat plate. •knock out the...

  • Page 24

    24 nouveau 7 multifuel stoves installation primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be longer...

  • Page 25

    Nouveau 7 multifuel stoves 25 installation checklist hearths, fireplaces, flues and chimneys this checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of the building regulations 2000 approved document j 2002....

  • Page 26

    26 nouveau 7 multifuel stoves parts list 1. Fuel retainers afs152 afs1019 afs001 afs010 afs008 afs058 afs009 2. Throat plate 3. Grate bar set 4. Hot plate 5. Operating tool 6. Ashpan 7. Flue spigot part description visual aid (not to scale) nouveau 7 part no. *pictures shown above may not represent ...

  • Page 27

    Nouveau 7 multifuel stoves 27 parts list 8. Liner set afs1016 afs1060 afs1061 afs1009 afs1010 afs1035 afs1077 9. Side liner 10. Back liner set 11. Glass replacement kit complete with gasket 12. Glass clips 13. Hinge kit comprises 2 hinges & 4 fixings per set. 14. Airwash part description visual aid ...

  • Page 28

    28 nouveau 7 multifuel stoves parts list 15. Fire door rope kit complete with door rope glue. Afs1021 afs1037 afs1007 afs040 afs997 16. Main doors assembly complete with handle,glass, gaskets,clips and seal. 17. Nouveau feet including fixings 18. Cast fire door locking assembly 19. Aarrow fires gaun...

  • Page 29: Guarantee

    Guarantee once again we would like to thank you for buying a nouveau fire. When you buy an aarrow fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. The nouveau 7 multifuel stove comes with a lifet...

  • Page 30

    Should you have any questions about your nouveau 7 multifuel stove that is not covered in this manual please contact your aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. 30 n...

  • Page 31: Lifetime Guarantee

    Lifetime guarantee for your peace of mind arada ltd gives a lifetime guarantee against manufacturing defects of the main body* of its nouveau range of multifuel fires. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the i...

  • Page 32: I’Ve Checked It

    Final factory check list bk011 quality finish parts flue outlet hot plate fuel retainers grate bars firebox linings throat plate air wash door catches interlock ash pan operating tool operating instructions feet & fixings model.................................. Serial no................................