Aarrow Aarrow Fires Stove TF 70 Operating And Installation Manual

Manual is about: Multifuel Boiler Stoves

Summary of Aarrow Fires Stove TF 70

  • Page 1

    Aarrow fires ltd the fireworks bridport dorset, dt6 3be great britain tel. (44) 01308 427234 fax. (44) 01308 427441 www.Aarrowfires.Com operating & installation manual please retain these instructions for future reference rev 5 june 2004 part no:afs1121 stratford tf 70 boiler stove (with optional st...

  • Page 2

    Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our stratford family to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so co...

  • Page 3

    Page introduction safety notices 5 the principle of the fire 5 check list 6 technical data 7 operating instructions multifuel grate 8 airwash inlet controls 8 interlock system 9 multi purpose operating tool 9 riddling 9 door trim and fire door glass 9-10 door adjustments 10 fuel retainer bars 10 fue...

  • Page 4: Warning

    Warning to all multifuel users petroleum coke some of whose brand names are "calco", "petrocoke" or "wonderco" must not be burned in this appliance to use these fuels will invalidate the appliance guarantee if in doubt contact the solid fuel association telephone number 0800 600 000 www.Solidfuel.Co...

  • Page 5

    Stratford tf & ti multifuel boiler stoves 5 introduction safety a fireguard conforming to bs 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to bs 3248 should be fitted. Do not use aerosol spra...

  • Page 6

    6 stratford tf & ti multifuel boiler stoves check list inside the appliance you should find the following: 1. Fuel retainers 2 2 2 2 part description &visual aid (not to scale) stratford tf 30b stratford tf 50b stratford tf 70b stratford tf 90b 2. Grate bars 5 7 9 9 3. Throat plate 1 1 1 1 4. Flue s...

  • Page 7

    Stratford tf & ti multifuel boiler stoves 7 technical data number of radiators in average installation *1kw = 3420 btu’s ** 25.4mm = 1 inch. 3.5 11,970 4.5 15,390 technical data stratford tf 50b stratford tf 70b stratford tf 90b 7.5 25,000 13 45,000 17.5 60,000 24 82,000 3 to 5 8 to 10 12 to 14 17 t...

  • Page 8

    Multifuel grate the aarrow multifuel grate comprises of a series of reciprocating cast iron bars seated on a pivoted "comb". These should come fitted in your stove, if not please refer to page 16 for fitting and operation and also operating instructions on fuels for correct settings of the grate. Ai...

  • Page 9

    Interlock system stratford tf and ti multifuel boiler stoves are fitted with an "interlock" system. A situation where the fire door is closed and the ash door is open may lead to serious overfiring which could damage the appliance. Correct use of the doors and interlock system will ensure that this ...

  • Page 10

    10 stratford tf & ti multifuel boiler stoves operating instructions step 4 remove the glass completely. Store glass- retaining clips and white gasket (if sound) safely for re-use. Step 5 follow this procedure in reverse to fit replacement door glass or gasket. Fig. 6 door adjustment the catch can be...

  • Page 11

    Stratford tf & ti multifuel boiler stoves 11 operating instructions fuel types wood- any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months i...

  • Page 12

    12 stratford tf & ti multifuel boiler stoves operating instructions ensure that you have read & understood these instructions before lighting the fire. Always wear suitable protective fire gloves when refuelling your stove. Solid fuel burning •set the grate to ‘coal’ position. •ensure that the ash p...

  • Page 13

    Stratford tf & ti multifuel boiler stoves 13 operating instructions ash removal the ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan. On no account should the ash be allowed to build up to touch the grate as this will greatly shorten its life. De...

  • Page 14

    14 stratford tf & ti multifuel boiler servicing maintenance it is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following: when the appliance is cold and unlit ensure ...

  • Page 15

    Stratford tf & ti multifuel boiler stoves 15 installation general precautions note - all installations must conform to the appropriate building regulations. The building regulations for england and wales 2000 ref approved document j 2002 edition (issued by the dtlr). The building standards (scotland...

  • Page 16

    Multifuel grate all bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "h" sitting on the high sections of the comb, and the ends marked "l" sitting on the low sections. Assembling the grate to assemble the grate, fit bars to low sect...

  • Page 17

    Stratford tf & ti multifuel boiler stoves 17 installation fitting the flue outlet and hot plate the flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin la...

  • Page 18

    18 stratford tf & ti multifuel boiler installation due to the gradual introduction of european chimney standards chimneys will be specified according to their performance designation as defined in bs en 1443 that covers the general requirements for chimneys. The minimum performance designation requi...

  • Page 19

    Stratford tf & ti boiler multifuel stoves 19 installation integral boilers integral boilers should be connected, with flow and return connection of any circuit on opposite sides of the appliance, (cross flowed), to an indirect hot water tank/system, adding fernox or similar corrosion inhibitor to pr...

  • Page 20

    20 stratford tf & ti boiler multifuel stoves installation ti models additional information for inset stoves (ti40b) builders opening / chimney breast stratford ti 40 fires are designed to be fitted into a rectangular recess not less than 400mm (15 3/4'') deep, not less than 400mm (15 3/4'') wide and...

  • Page 21

    Stratford tf & ti multifuel boiler stoves 21 installation.

  • Page 22

    22 stratford tf & ti boiler multifuel stoves installation p lan v iew of register plate and clearances for non insulated flues a is minimum clearance for non-insulated flue = 1.5 x d to a non-combustible surface/material or 3 x d to combustible surface/material.

  • Page 23

    Stratford tf & ti boiler multifuel stoves 23 installation central heating and domestic hot water system using four boiler tappings central heating system without domestic hot water using four boiler tappings note: diagrammatic representation only. Design and calculations for individual systems shoul...

  • Page 24

    24 stratford tf & ti multifuel boiler stoves installation central heating system without domestic hot water using three tappings note: diagrammatic representation only. Design and calculations for individual systems should always be carried out by a qualified heating engineer. Central heating and do...

  • Page 25

    Stratford tf & ti multifuel boiler stoves 25 boiler tapping positions stratford tf30 boiler tapping positions stratford tf50 boiler tapping positions all dimensions in mm.

  • Page 26

    26 stratford tf & ti multifuel boiler stoves boiler tapping positions stratford tf70 boiler tappings positions stratford tf90 boiler tappings positions all dimensions in mm.

  • Page 27

    Stratford tf & ti multifuel boiler stoves 27 boiler tapping positions stratford ti 40 inset boiler tapping positions all dimensions in mm.

  • Page 28

    Water connections heating systems the size of the heating system which can be run, will depend on the output rating of the appliance. It will be necessary to work out heat loss calculations for the system proposed in order to establish the kw/hr rating. An appliance that will meet this figure can th...

  • Page 29

    Stratford tf & ti multifuel boiler stoves 29 installation temperature and pressure relief valve with solid fuel appliances it is not practicable to provide a sufficiently rapid reaction for shutting down fuel in the event of a sudden rise in water temperature and a temperature relief valve or prefer...

  • Page 30

    30 stratford tf & ti multifuel boiler stoves check list checklist hearths, fireplaces, flues and chimneys this checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of the building regulations 2000 approved doc...

  • Page 31

    Stratford tf & ti boiler multifuel stoves 31 parts list 1. Fuel retainers afs152 afs153 afs153 afs153 afs030a afs031 afs034 afs035 afs001 afs001 afs002 afs003 afs010 afs010 afs012 afs012 afs008 afs008 afs008 afs008 afs050 afs051 afs052a afs116 afs009 afs009 afs011 afs011 2. Throat plate 3. Grate bar...

  • Page 32

    32 stratford tf & ti multifuel boiler stoves parts list 8. Airwash afs1077 afs1077 afs1077 afs1077 afs088 afs090 afs090 afs090 afs089 afs091 afs091 afs091 afs047 afs047 afs047 afs047 afs048 afs048 afs048 afs048 afs200 afs201 afs0201 afs201 afs095 9. Glass replacement kit complete with gasket 10. Gla...

  • Page 33

    Stratford tf & ti multifuel boiler stoves 33 parts list 15. Fire door locking assembly afs204 afs204 afs204 afs204 afs020 afs020 afs020 afs020 afs022 afs022 afs022 afs022 afs021 afs021 afs021 afs021 afs007 afs007 afs007 afs007 afs168a afs170a afs0172a afs172a afs075a afs077a afs082a afs082a 16. Ther...

  • Page 34: Guarantee

    Guarantee once again we would like to thank you for buying a stratford multifuel boiler stove. When you buy an aarrow fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. Your aarrow fire carries a d...

  • Page 35

    Should you have any questions about your stratford stove that is not covered in this manual please contact your aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. Stratford tf &...

  • Page 36: I’Ve Checked It

    Bk029 final factory check list quality finish parts flue outlet hot plate fuel retainers grate bars fire bed surrounds throat plate air wash door catches interlock ash pan operating tool thermostat operating instructions model.................................. Serial no............................. ...