Aarrow Arley Operating & Installation Manual

Manual is about: Wood & Multifuel Stoves

Summary of Arley

  • Page 1

    Arley wood & multifuel stoves operating & installation manual please retain these instructions for future reference arley 5 flat multifuel stove rev 1 june 2004.

  • Page 2

    Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our arley family to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so confid...

  • Page 3

    Introduction page safety notices 5 the principle of the fire 5 check list 6 technical data 7 operating instructions firebox linings and throat plate removal 8 airwash system 8 multi-purpose operating tool 9 fire door glass 9 door adjustment 10 fuel retainer bars 10 fitting the feet 10 fuel types 11 ...

  • Page 4: Warning

    Warning to all multifuel users petroleum coke some of whose brand names are "calco", "petrocoke" or "wonderco" must not be burned in this appliance to use these fuels will invalidate the appliance guarantee if in doubt contact the solid fuel association telephone number 0800 600 000 www.Solidfuel.Co...

  • Page 5

    Arley wood & multifuel stoves 5 introduction safety a fireguard conforming to bs 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to bs 3248 should be fitted. Do not use aerosol sprays or any ot...

  • Page 6

    6 arley wood & multifuel stoves check list 12. Multifuel riddling kit optional accessory n/a 13. Instructions 1 11. Optional woodburning tray 1 optional accessory 5 part description & visual aid (not to scale) arley 5 multifuel 2 1 4. Flue spigot 1 (4”) 5. Hotplate 7. Operating tool 1 8. Rear liner ...

  • Page 7

    Arley wood & multifuel stoves 7 technical data room min/max room heater only output (kw) 1 - 5 technical data arley 5 multifuel room heater with domestic hot water with add in boiler type 0 max output to room (kw) max output to water (kw) 3 2 height (mm) 497 width (mm) 405 depth (mm) 358 height to c...

  • Page 8

    Firebox linings & throat plate the arley wood and multifuel stoves firebox have reflective liners to the sides and rear and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these. Multifuel grate the aarrow multifuel grate compris...

  • Page 9

    Multi - purpose operating tool your aarrow fire comes with a multi-purpose tool, which is used for riddling, setting the multifuel grate position. Use the operating tool for setting the grate in the coal burning position or the wood burning position. This lever is also used for de-ashing and riddlin...

  • Page 10

    Door adjustment once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture. This is quite normal and due to the settling of the casing. The fire door can be re-aligned by the user as follows: •when the applia...

  • Page 11

    Fuel types wood- any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case o...

  • Page 12

    Ensure that you have read & understood these instructions before lighting the fire. Always wear suitable protective fire gloves when refuelling your stove. Solid fuel burning •set the grate to ‘coal’ position. •ensure that the ash pan is in position and the fire doors are closed. •set the air wash t...

  • Page 13

    Ash removal wood burner only ash will drop through the holes and to the slides of the specially designed wood tray. This should be removed from the stove periodically. It is advisable to leave a layer of ash on the wood tray to prolong its life and maintain optimum conditions for burning wood. Ash r...

  • Page 14

    Annual maintenance it is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following. Remove the firebricks lining and throat plate, inspect all gasketing on doors, glass ...

  • Page 15

    Arley wood & multifuel stoves 15 accessories accessories wood burning trays to turn your multifuel stove into a dedicated woodburner. As shown in fig. 10a below multifuel upgrade kit available for the wood burning range to enable you to burn solid fuel in your arley wood stove. (see fig 10b) add in ...

  • Page 16

    16 arley wood & multifuel stoves installation general precautions note - all installations must conform to the appropriate building regulations. The building regulations for england and wales 2000 ref approved document j 2002 edition (issued by the dtlr). The building standards (scotland) (consolida...

  • Page 17

    Arley wood & multifuel stoves 17 installation firebox liner panels the arley wood and multifuel stoves use reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them....

  • Page 18

    Multifuel grate grate the grates in the arley multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "h" sitting on the high sections of the...

  • Page 19

    Interchangeable canopies the canopy versions for the arley 7 & 11 range is a flat top stove to which a low or high canopy can be fitted after installation and are interchangeable. These are fitted as follows: •to fit the interchangeable canopy (fig 10c): •remove the front clamps. •tilt the canopy as...

  • Page 20

    20 arley wood & multifuel stoves installation fitting the flue outlet and hot plate the flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire ...

  • Page 21

    Due to the gradual introduction of european chimney standards chimneys will be specified according to their performance designation as defined in bs en 1443 that covers the general requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is t450 ...

  • Page 22

    22 arley wood & multifuel stoves installation.

  • Page 23

    Arley wood & multifuel stoves 23 installation p lan v iew of register plate and clearances for non insulated flues t ypical m etal i nsulated c himney s ystem t o be installed to the chimney manufacturers instructions in compliance with building regulations and bs7566 p ts 1-4 a is minimum clearance...

  • Page 24

    24 arley wood & multifuel stoves installation add in boilers arley wood and multifuel stoves offer the option of a cantilever boiler or a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •remove the fuel retainers, rear firebox liner panels and throat plate. •knock...

  • Page 25

    Arley wood & multifuel stoves 25 installation primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be lon...

  • Page 26

    26 arley wood & multifuel stoves installation checklist hearths, fireplaces, flues and chimneys this checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of the building regulations 2000 approved document j 20...

  • Page 27

    Arley wood & multifuel stoves 27 parts list 1. Fuel retainers afs1150 afs1150 afs1012 afs1018 afs1018 afs1019 n/a afs001 n/a afgs064 afgs064 afs009 afs008 afs008 afs008 afs058 afs058 afs058 afs009a afs009a afs010 2. Throat plate 3. Grate bar set 4. Hot plate 5. Operating tool 6. Ashpan 7. Flue spigo...

  • Page 28

    28 arley wood & multifuel stoves parts list 8. Liner set afs1015 afs1015 afs1156 afs1058 afs1058 afs1058 afs1059 afs1059 afs1157 afs1075 afs1075 afs1009 afs1010 afs1010 afs1010 afs047 afs047 afs047 afs1144 afs1144 afs1144 9. Side liner 10. Back liner set 11. Glass replacement kit complete with gaske...

  • Page 29

    Arley wood & multifuel stoves 29 parts list 16. Fire door rope kit complete with door rope glue. Afs1021 afs1021 afs1021 afs1021 afs1145 afs1145 left hand afs1158 right hand afs1159 l/h afs1158 r/h afs1159 afs1149 n/a afs1154 afs1146 afs1146 afs1146 afs1146 afs997 afs997 afs997 afs997 afs1151 arl5 w...

  • Page 30: Guarantee

    Guarantee once again we would like to thank you for buying an aarrow fire. When you buy an aarrow fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. Your aarrow fire carries a guarantee against def...

  • Page 31

    Should you have any questions about your arley wood or multifuel stove that is not covered in this manual please contact your aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. ...

  • Page 32: I’Ve Checked It

    Final factory check list bk026 quality finish parts flue outlet hot plate fuel retainers grate bars / wood tray firebox linings throat plate air wash door catches feet & fixings ash pan operating tool operating instructions model.................................. Serial no..............................