Aarrow Gas Stove Installation Manual

Manual is about: Aarrow Fires Installation / Servicing Instructions & User Manual Gas Stove

Summary of Gas Stove

  • Page 1

    Arada ltd north mills industrial estate, bridport, dorset, united kingdom dt6 3be tel (+44) 01308 427234 fax (+44) 01308 423441 www.Arada.Uk.Com sherborne gsl conventional flue gas stove installation / servicing instructions & user manual please retain these instructions for future reference this st...

  • Page 2

    Installation safety notices 3 general information 3-4 contents list & part identification 5 important notices 6 statutory requirements 6 certification 6 technical data 7 gas fire dimensions 7 installing the stove 7 preparation of the stove 8 stove location 8 shelf clearances 9 flue system 10 fitting...

  • Page 3

    References in this manual to british standards and statutory regulations and requirements apply only to the united kingdom. For ireland the rules in force must be used. Before installation, check that the local distribution conditions, nature of the gas, pressure and the adjustment of the appliance ...

  • Page 4

    5. Stove location see installation instructions on page 7. 6. Packed details for packed weight see packaging labels. 7.Unpacking note when the stove is unpacked ensure no damage occurs if placed on the carpet as it can leave inden- tation marks. For contents list see page 5. 8. Fit for purpose all m...

  • Page 5

    All types main box aarrow sherborne gsl cf 5 installation instructions • • packed inside stove coal set (ng & lpg) or log set (ng only) or • • log set (lpg only) • glass frame assembly stove engine dummy fuel retainer outer body & canopy fire doors valve cover • • • • operating instructions canopy c...

  • Page 6

    Important notices a qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current building regulations. Such person must be a registered corgi engineer. This appliance is designed to run on natural gas (ng)...

  • Page 7

    Aarrow sherborne gsl cf 7 installation instructions technical data natural gas gas category i 2h nox class unclassified table 1 fig. 3 efficiency class class 2 installing the stove a corgi qualified gas engineer must install the stove in accordance with the following regulations and stan- dards:- th...

  • Page 8

    Preparation of the stove prior to starting the installation and after removing the packaging, check that all the parts have been supplied to the contents list on page 5. Carry out the following:- step 1 remove outer casing (disengage locking levers see page 25, steps 1a /b, 2, 3, 4, and 5). Step 2 r...

  • Page 9

    Shelf clearances combustible shelf clearances the minimum height from the extreme top surface of the stove to the underside of a shelf or other projection made of wood or any other combustible material is shown on graph 1. Non-combustible shelf clearances the minimum height from the extreme top surf...

  • Page 10

    Flue system the stove must be connected to a suitable and efficient flue that provides a good updraught to safely take the products of combustion (fumes) from the stove outlet to the outside air. To ensure a good updraught it is important that the flue gases are kept warm and that the flue size suit...

  • Page 11

    Fitting the flue spigot and blanking plate note: blanking plate fitted to top flue outlet for packing the gas stove is designed so that the flue can be fitted to either the top or the rear of the appliance. Fit the flue spigot and blanking plate for either top or rear flue outlet in accordance with ...

  • Page 12

    12 aarrow sherborne gsl cf installation instructions fig. 6b fig. 6a fig. 6c. Y=see graph 1.

  • Page 13

    Connecting the gas supply once the stove is in place it is then possible to connect the gas supply. The gas supply point is located centrally at the rear (as show in fig.7) and should be connected in accordance with the follow- ing requirements. Fig. 7 check that the appliance is suitable for the ga...

  • Page 14

    Fitting and arranging the coals (both ng & lpg versions) ensure the appliance is cold safety notice - please see safety notices ref. Coal / log sets page 3. Warning: the coals and the coal matrix are fragile ensure they are handled carefully. Ensure location is correct. Do not force the matrix into ...

  • Page 15

    Plan view of coal set layout. Note - ensure that the pilot light is visible through the slot in the front right base matrix and that the pilot flame is not impinged. Fitting and arranging the logs (ng only) ensure the appliance is cold safety notice - please see safety notices ref. Coal / log set, p...

  • Page 16

    Upper corner of the curved left hand log. See fig. 12b. Note, the top resting position of the central log is angled to the left. 6) place 2x smaller twigs as shown in fig. 12b. Note, the bottom of the twigs rest between the stove body and burner. Take care with the right hand twig to avoid impinging...

  • Page 17

    3) place the curved log to the left hand side of the firebox, rest the top of this log onto the top of the y shaped open end of the rear log. Take the straight log and position this to the right hand side of the firebox, again rest the rear of this log onto the rear y shaped log, opposite end to the...

  • Page 18

    Note: if the optional remote control system has been ordered with the stove and is not fitted please proceed. For a manual stove (without remote control) proceed to page 22. Installation of remote control system important • a corgi registered gas engineer must carry out the installation of the remot...

  • Page 19

    Assemble motor 1) remove the front cover from the valve. This is done by unscrewing the small pozi screw, located by knob b. Unclip the right hand side of the cover located to the side of knob a. See fig. 16a & b. 2) remove the cover and dispose of the spacer tube fitted with the screw. 3) position ...

  • Page 20

    Assemble receiver important the remote system is intended for use with original aarrow parts only. 1) carefully push the multi block connector on to the connection within the reciever unit as shown in fig 17a. This connector can only fit one way, so ensure the slot in the recievers board lines up wi...

  • Page 21

    Handset 1) insert the battery (9v) into remote control. Slide back the battery compartment cover, insert and connect a suitable battery and replace the cover. 2) the remote is now ready to use. In the event of battery failure the flame height can still be adjusted man- ually using the knob b on the ...

  • Page 22

    Commissioning the stove refit the glass/glass frame assembly. Refit the outer body and secure with the locking levers. If horizontal flue is used fit the canopy cover plate. (see page 25 step 1a.) if top flue is used locate the infill plate (see page 25 step 1b). Follow the lighting instructions (se...

  • Page 23

    Advise the end user 1. That there will be an odour from the stove when the stove is first lit and is non-toxic. It is advised that the stove is initially run with the room well ventilated to disperse the fumes. 2. How the valve controls operate and how to light the pilot. 3. Advise about leaving pil...

  • Page 24

    24 aarrow sherborne gsl cf installation instructions checklist hearths, fireplaces, flues and chimneys this checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of the building regulations 2000 approved docume...

  • Page 25

    Aarrow sherborne gsl cf 25 servicing replacement of the glass important when refitting the glass frame ensure the origi- nal screws are used. Longer screws may foul the coal / log set placement. Ensure the appliance is cold. Step 1a for rear flue appliance remove canopy cover plate. Step 1b for top ...

  • Page 26

    26 aarrow sherborne gsl cf servicing step 7 clear inside of stove of any debris. Step 8 to re-assemble reverse this procedure. See initial note on page 25. Note: when relocating the body and canopy assembly ensure the front location tab is engaged in the chassis. Burner and valve assembly removal pl...

  • Page 27

    Annual service this gas appliance must be serviced every twelve months by a qualified gas engineer. See "safety notices" ref coal set page 3. Ensure the appliance is cold. Step 1 isolate the gas supply from the stove. Step 2 remove the outer body of the stove. Step 3 remove the glass. Important: if ...

  • Page 28

    28 aarrow sherborne gsl cf servicing is the gas supply turned on? Does the pilot ignite? Yes does the pilot stay alight? Yes does the main burner light? Yes no is their air in the system? Yes is the main injector blocked? Yes clean and replace as necessary is the supply pressure correct? No is the t...

  • Page 29

    Should you have any questions about your sherborne gsl gas stove that is not covered in this manual please contact your aarrow stove retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. ...

  • Page 30

    30 aarrow sherborne gsl cf additional notes.

  • Page 31: User

    User instructions aarrow sherborne gsl cf 31.

  • Page 32

    Lighting & controlling the fire under no circumstances must the stove be operated if the glass is cracked or broken. It is recommended that if the property is occupied the pilot be left on permanently. This will keep the stove and its components, including the ceramic coal / log set in a warmer stat...

  • Page 33

    Step 3. To turn the stove and the pilot off completely , turn control knob “a” to the small flame setting, (pilot frame) depress and turn to off position, then release (see fig. 20e) fig. 20e important , when control knob “a” is turned to the off position a built-in safety lock is activated which wi...

  • Page 34

    Note: only for stoves with remote control system temperature display remote control when the pilot has been lit, the remote transmitter can be used to control the flame height or to turn the main burner on or off. Aim the remote transmitter at the control valve and press the top button 'a' to increa...

  • Page 35

    Thermostat and timer remote control transmitter functions set the display (from *c/24 h to *f/12 h and vice versa) • after connecting the battery or by simultaneously pressing auto and timer, the display flashes you are in set mode. • from set mode, press auto to switch from *f (and 12 hour clock) t...

  • Page 36

    Manual mode (man in display) for manual flame height adjustment • press ( a ) to turn on the fire (main burner) or to increase flame height. • press ( b ) to decrease the flame or to turn down to pilot. • to incrementally increase or decrease the flame height lightly tap either the ( a ) or ( b ) bu...

  • Page 37

    Slide back the battery compartment cover, insert 4 suitable batteries and replace the cover if the batteries lose power, the flame height can be adjusted by manually turning knob b (see page 32) note please note the placement of the remote control (temperature sensor) is important to assure proper t...

  • Page 38

    Important notices a qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current building regulations. Such person must be a registered corgi engineer. This appliance is designed to run on natural gas or l...

  • Page 39

    Shelf clearances combustible shelf clearances the minimum height from the extreme top surface of the stove to the underside of a shelf or other projection made of wood or any other combustible material is shown on graph 1. Non-combustible shelf clearances the minimum height from the extreme top surf...

  • Page 40

    40 aarrow sherborne gsl cf spare parts 1. Coal set (complete) afgs1115 afgs1121 afgs1123 afgs1124 afgs1087 afgs1125 afgs1126 3. Log set - lpg (complete) 4. Injector ng - bray 82/400 5. Injector lpg - bray 82/160 6. Pilot assembly - ng 7. Pilot assembly - lpg 8. Top burner assembly ng part descriptio...

  • Page 41

    Aarrow sherborne gsl cf 41 spare parts 10. Control valve afgs1089 afgs1128 afgs1093 afs047 afgs1118 afgs1095 afgs1096 11. Fire door set (with handles) 12. Glass frame assembly 13. Hinge kit & with fixings- 14. Dummy fuel retainer 15. Instruction manual 16. Stove glass rope gasket part description vi...

  • Page 42

    42 aarrow sherborne gsl cf spare parts 17. Top flue cover plate afgs1098 part description visual aid (not to scale) part number afgs1120 18. Top flue infill piece afgs1119 19. Valve cover afgs1129 20. Flue spigot complete with rope gasket afgs010 21. Hot plate complete with rope gasket 23. Operating...

  • Page 43

    Aarrow sherborne gsl cf 43 options & accessories remote control - a remote control system can be retro-fitted to your sherborne gsl stove. This system allows convenient control of the stove, room temperature regulation and the advantage, to be programmable to enable switching on / off by a timer fun...

  • Page 44

    44 aarrow sherborne gsl cf guarantee your sherborne gsl stove carries a liftime* guarantee against defects to the stove body. All other components carry a guarantee period of one year from the date of purchase . This does not apply to items which would be subject to fair wear or tear. However, shoul...

  • Page 45

    Aarrow sherborne gsl cf 45 additional notes.

  • Page 46: I’Ve Checked It

    Model.................................. Serial no............................. I’ve checked it and it’s o.K. Assembled by............................. Checked by ................................ All types bk047 final factory assembly check list quality finish instruction manual registration card gas...