PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Sherborne Medium Multifuel Stove
Rev 2
Nov 2006
AFS1237
Sherborne
Summary of Sherborne Large Multifuel
Page 1
Arada ltd the fireworks bridport dorset, dt6 3be great britain tel. (44) 01308 427234 fax. (44) 01308 423441 www.Aarrowfires.Com wood & multifuel stoves operating & installation manual please retain these instructions for future reference sherborne medium multifuel stove rev 2 nov 2006 afs1237 sherb...
Page 2: Lifetime Guarantee
Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our sherborne, range to ensure ultimate performance and years of trouble free enjoyment. Every detail on the stoves has been carefully engineered and designed which is why we are so ...
Page 3
Introduction page safety notices 5 the principle of the fire 5 check list 6 technical data 7 operating instructions firebox linings and throat plate removal 8 multifuel grate 8 wood stove - wood tray 8 air inlet controls/airwash system 8-9 multi-purpose operating tool 9 fire door glass 9 door adjust...
Page 4: Warning
Warning to all multifuel users petroleum coke some of whose brand names are "calco", "petrocoke" or "wonderco" must not be burned in this appliance to use these fuels will invalidate the appliance guarantee if in doubt contact the solid fuel association telephone number 0800 600 000 www.Solidfuel.Co...
Page 5
Sherborne wood & multifuel stoves 5 introduction safety a fireguard conforming to bs 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to bs 3248 should be fitted. Do not use aerosol sprays or an...
Page 6
6 sherborne wood & multifuel stoves check list 11. Multifuel riddling kit optional accessory n/a 12. Instructions 1 10. Woodburning tray 1 optional accessory 7 part description & visual aid (not to scale) sherborne small multifuel 2 1 4. Flue spigot 1 (5”) 5. Hotplate 7. Operating tool 1 8. Rear lin...
Page 7
Sherborne wood & multifuel stoves 7 technical data room min/max room heater only output (kw) 1.5 - 6 technical data sherborne small multifuel room heater with domestic hot water with add in boiler type 8 max output to room (kw) max output to water (kw) height (mm) 505 width (mm) depth (mm) height to...
Page 8
Firebox linings & throat plate the sherborne range of wood and multifuel stoves firebox have reflective liners to the sides and rear and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these. Multifuel grate the aarrow multifuel ...
Page 9
Fig. 4b lifting cover from body of stove fig. 4c unscrewing multi - purpose operating tool your aarrow fire comes with a multi-purpose tool, which is used for riddling, setting the multifuel grate position. Use the operating tool for setting the grate in the coal burning position or the wood burning...
Page 10
Door adjustment once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture. This is quite normal and due to the settling of the casing. The fire door can be re-aligned by the user as follows: •when the applia...
Page 11
Fuel types wood- any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case o...
Page 12
Ensure that you have read & understood these instructions before lighting the fire. Always wear suitable protective fire gloves when refuelling your stove. Solid fuel burning •set the grate to ‘coal’ position. •ensure that the ash pan is in position and the fire doors are closed. •set the air wash t...
Page 13
• check for flue or chimney blockage, and clean if required. Seek expert advice from your hetas registered installer. Do not attempt to re-light the fire until the cause of the fume emission has been identified and corrected. Ash removal - wood burner only ash will drop through the holes and to the ...
Page 14
Remove the firebricks lining and throat plate, inspect all gasketing on doors, glass etc., and re-order any items that may need replacing, from your aarrow dealer. With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above t...
Page 15
Sherborne wood & multifuel stoves 15 accessories accessories wood burning trays to turn your multifuel stove into a dedicated woodburner. As shown in fig. 10a below multifuel upgrade kit available for the wood burning range to enable you to burn solid fuel in your sherborne woodburning stove. (see f...
Page 16
16 sherborne wood & multifuel stoves installation general precautions note - all installations must conform to the appropriate building regulations. The building regulations for england and wales 2000 ref approved document j 2002 edition (issued by the dtlr). The building standards (scotland) (conso...
Page 17
Sherborne wood & multifuel stoves 17 installation firebox liner panels the sherborne wood and multifuel stoves use reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to f...
Page 18
Multifuel grate grate the grates in the sherborne multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "h" sit- ting on the high sections ...
Page 19
Interchangeable canopies the canopy versions for the sherborne range are slab top stoves to which a low or high canopy can be fitted after installation and are interchangeable. These are fitted as follows: •to fit the interchangeable canopy (fig 10c): •remove the front clamps. •tilt the canopy as sh...
Page 20
20 sherborne wood & multifuel stoves installation fitting the flue outlet and hot plate the flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of f...
Page 21
Due to the gradual introduction of european chimney standards chimneys will be specified according to their performance designation as defined in bs en 1443 that covers the general requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is t450 ...
Page 22
22 sherborne wood & multifuel stoves installation.
Page 23
Sherborne wood & multifuel stoves 23 installation p lan v iew of register plate and clearances for non insulated flues t ypical m etal i nsulated c himney s ystem t o be installed to the chimney manufacturers instructions in compliance with building regulations and bs7566 p ts 1-4 a is minimum clear...
Page 24
24 sherborne wood & multifuel stoves installation add in boilers sherborne wood and multifuel stoves offer the option of a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •remove the fuel retainers, rear firebox liner panels and throat plate. •knock out the blanki...
Page 25
Sherborne wood & multifuel stoves 25 installation primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be...
Page 26
26 sherborne wood & multifuel stoves installation checklist hearths, fireplaces, flues and chimneys this checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of the building regulations 2000 approved document ...
Page 27
Sherborne wood & multifuel stoves 27 parts list 1. Fuel retainers afs1192 afs1192 afs1191 afs1019 afs1019 afs1020 n/a afs001 n/a afs009 afs009 afs009 afs008 afs008 afs008 afs058 afs058 afs051 afs010 afs010 afs010 2. Throat plate 3. Grate bar set 4. Hot plate 5. Operating tool 6. Ashpan 7. Flue spigo...
Page 28
28 sherborne wood & multifuel stoves parts list 8. Liner set afs1156 afs1156 afs1163 afs1058 afs1058 afs1164 afs1157 afs1157 afs1165 afs1009 afs1009 afs1095 afs1010 afs1010 afs1010 afs047 afs047 afs047 afs1233 afs1233 afs1233 9. Side liner 10. Back liner set 11. Glass replacement kit complete with g...
Page 29
Sherborne wood & multifuel stoves 29 parts list 16. Fire door rope kit complete with door rope glue. Afs1021 afs1021 afs1021 afs1021 l/h afs1234 r/h afs1235 l/h afs1234 r/h afs1235 l/h afs1238 r/h afs1239 l/h afs1238 r/h afs1239 afs1237 afs1237 afs1237 afs1236 afs1236 afs1236 afs1236 afs1197 shbsw b...
Page 30: Guarantee
Guarantee once again we would like to thank you for buying a sherborne fire. When you buy an aarrow fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. The sherborne stoves come with a lifetime guar...
Page 31
Should you have any questions about your sherborne wood or multifuel stove that is not covered in this manual please contact your aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record cha...
Page 32: I’Ve Checked It
Final factory check list bk046 quality finish parts flue outlet hot plate fuel retainers x2 grate bars / wood tray firebox linings throat plate air wash door catch ash pan operating tool operating instructions model.................................. Serial no............................. I’ve checke...