Aarrow Signature Inset 5 Operating & Installation Manual

Summary of Signature Inset 5

  • Page 1

    Operating & installation manual bk075 en 13240:2001+ amd. A2:2004 rev. 06 october2009 part no. Afs1397 09 please retain this guide for future reference signature inset 5.

  • Page 2

    Congratulations on your choice of an aarrow stove. More than 20 years experience has been put into the development of our signature inset range to ensure ultimate performance and years of trouble free use and enjoyment. Every detail of the stove has been carefully designed and engineered which is wh...

  • Page 3: Contents

    Contents page 3 aarrow signature inset 5 introduction page no. Warning notice 4 safety notices 5 the principle of the stove 5 check list 6-7 data plate information 7 technical data 8 installation general precautions 9 handling 9 air for combustion 9 hearth 9-10 flues & chimneys 11-12 sealing the bac...

  • Page 4: Warning

    Page 4 aarrow signature inset 5 warning it is a legal requirement that the installation of all new or replacement, wood or solidfuel heating appliances are required to obtain building control approval from your local authority or the installation work must be carried out through a government approve...

  • Page 5: Introduction

    Introduction page 5 aarrow signature inset 5 safety a fireguard conforming to bs 8423:2002 should be used in the presence of children and old or infirm people. Please note, this appliance should be used with the fire door closed at all times except when re-fuelling, initial lighting or de-ashing. Do...

  • Page 6: Check List

    Part description & visual aid (not to scale) signature inset 5 1. Fuel retainer 1 2. Throat plate 1 3. Side liner 2 6. Tertiary air bar 1 7. Ash pan 1 8. Operating tool 1 9. Instruction manual 1 4. Back liner 1 5. Wood burning tray 1 check list page 6 inside the appliance body you should find the fo...

  • Page 7: Check List

    Check list page 7 inside the appliance body you should find the following, cont: part description & visual aid (not to scale) signature inset 5 10. Fire door handle 1 11. Heat resistance mitten 1 12. Optional fixing bolts 2 data plate information please note : the aarrow signature 5 stove is fitted ...

  • Page 8: Technical Data

    Technical data page 8 aarrow signature inset 5 technical data signature inset 5 nominal heat output (kw) 4.8 efficiency nett (%) 80.1 mean flue gas temperature (°c) 261 mean co emissions @ 13% o 2 (%) 0.50 height (mm) 590 width (mm) 562 depth overall (mm) (inc. Handle) 435 depth from fire surround (...

  • Page 9: Installation

    Installation page 9 aarrow signature inset 5 general precautions note : all local regulations, including those refer- ring to national and european standards need to be complied with, when installing the appliance. The building regulations for england and wales 2000 ref approved document j 2002 edit...

  • Page 10

    Page 10 aarrow signature inset 5 fig 1 signature 5 stove cross sectional view, installed into a standard 16” or 18”chair brick installation throat forming lintel insulating infill expansion joint thin straw board or corrugated cardboard etc. Non-combustible sealing rope ( see page 12 ) constructiona...

  • Page 11

    Installation 11 aarrow signature inset 5 flues and chimneys the flue draw is critical on any installation and should be checked to ensure that it matches what is specified. If it is higher than recommended, provision must be made to correct the over draw. The draw can vary in different weather condi...

  • Page 12: Important Notice:

    Installation page 12 aarrow signature inset 5 sealing the back of the stove to the decorative fire surround in order for the stove to operate at maximum efficiency it is necessary to achieve a good seal between the back face of the stove convector section, and the deco- rative hearth surround (see f...

  • Page 13

    Page 13 aarrow signature inset 5 installation firebox liner panels the aarrow signature inset 5 stoves use firebox liner panels to the sides and back. See fig 2 the throat plate sits on top of the sides and rear panels. These should come fitted to your stove, if however they are not, proceed as foll...

  • Page 14

    Page 14 aarrow signature inset 5 installation final check list before handing over the installation to the customer it is requirement under document j that the appliance is lit and the functioning of the chimney system is checked for satisfactory operation. • be sure that the chimney is operating an...

  • Page 15

    Page 15 aarrow signature inset 5 building control consent checklist hearths, fireplaces, flues and chimneys this checklist is to ensure heaths, fireplaces, flues and chimneys are satisfactory, and show what you have done to comply with the requirements of the building regulations 2000 approved docum...

  • Page 16

    Page 16 aarrow signature inset 5 annual maintenance it is important that your appliance is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following : cleaning important; under some circumstances s...

  • Page 17

    Page 17 aarrow signature inset 5 service & maintenance summer storage / non usage please ensure that your stove is left clean and moving components are well lubricated for the summer months (during periods of prolonged non use). If possible store the throat plate outside of the stove, check all move...

  • Page 18

    Page 18 aarrow signature inset 5 service & maintenance fire door rope replacement periodically, visually check over the fire door rope seal for any damage, cuts or tears and any detached sections. The rope gasket can be replaced, using the universal rope kit (see spare parts guide page 28/29), pleas...

  • Page 19

    Page 19 aarrow signature inset 5 service & maintenance please note—this should be carried out when the fire is cold and unlit. Fig. 10. Positioning the glass fig. 11. Tightening the glass clip fire door primary air inlet once a year a check is required to inspect the primary air inlet assembly, loca...

  • Page 20: Service Record

    Page 20 service & maintenance should you have any questions about your aarrow signature inset stove that are not covered in this manual please contact your aarrow dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete...

  • Page 21

    Page 21 aarrow signature inset 5 operating instructions suitable fuel safety notice the most efficient use of this appliance is with the fire door closed at all times, apart from re- fuelling (when alight) or cleaning (when cold). Never leave the appliance unattended for an extended length of time w...

  • Page 22

    Page 22 aarrow signature inset 5 operating instructions burning wood • set the fire by using rolled up newspaper and a layer of dry kindling wood on top of this. • use 2 or 3 fire lighters to light the kindling. • set the air wash control to the fully open position. See page 24. • after the kindling...

  • Page 23

    Page 23 aarrow signature inset 5 operating instructions over firing & chimney fires do not over fire your appliance. Using flammable liquids or too much wood or firing the stove at maximum for prolonged periods may result in over- firing. If the chimney connector or casing glows red the appliance is...

  • Page 24

    Page 24 aarrow signature inset 5 operating instructions air inlet controls the aarrow signature 5 stoves have two air inlet controls. The primary air inlet providing under draught to the base of the fire chamber through the control slider located under the oval at the base of the fire door. The air ...

  • Page 25

    Operating instructions page 25 aarrow signature inset 5 fuel retainer bar a fuel retaining bar is supplied with the signature 5 stove (fig 17). For fitting please follow steps 1 to 3 detailed below.. Please note—this should be carried out when the stove is cold and unlit. Installing the cast fuel re...

  • Page 26

    Page 26 aarrow signature inset 5 operating instructions multi purpose operating tool your aarrow stove is supplied with a multi purpose operating tool, used for adjusting the air inlet control and the removal of the ash pan. (see fig 18) to empty the ash pan the signature 5 stoves are supplied with ...

  • Page 27

    Page 27 aarrow signature inset 5 operating instructions main fire door handle a stove mitten is supplied with your aarrow signature 5 stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surroun...

  • Page 28

    Page 28 aarrow signature inset 5 optional extra / accessories part description visual aid ( not to scale ) signature 5 inset aerosol touch up paint afs 101 gothic door tracery seb15 traceg lattice door tracery seb15 tracel flue gather kit (includes fixings) 5 inset gather multi fuel upgrade kit (inc...

  • Page 29

    Page 29 aarrow signature inset 5 part description visual aid ( not to scale ) signature 5 inset replacement manual afs1397 air wash control knob (includes washer) afs1405 replacement hot glove afs1285 throat plate afs1402 ash pan afs1395 rear liner afs1410 side liner afs1409 complete liner set afs14...

  • Page 30

    Spare parts page 30 aarrow signature inset 5 part description visual aid ( not to scale ) signature inset 5 replacement door glass gasket and clips afs1365 replacement door glass kit (includes fixings) afs1386 hinge kit (includes fixings) afs1279 fire door rope kit & glue afs1021 fire door assembly,...

  • Page 31

    Page 31 aarrow signature inset 5 guarantee guarantee once again we would like to thank you for buying an aarrow signature 5 inset stove. When you buy an aarrow stove, you are not only buying a first class appliance you are buying a commitment from us to look after you and your appliance for as long ...

  • Page 32: Lifetime Guarantee

    Page 32 aarrow signature inset 5 aarrow stoves give a lifetime guarantee against manufacturing defects of the main body* of its signature 5 inset stove. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and do...

  • Page 33

    Page 33 aarrow signature inset general dimensions maximum width in front of fireplace (210mm) requires a 225mm hearth totalling 435mm 210

  • Page 34: I’Ve Checked It

    Bk075 final factory check list stove model :…’ signi 5 w’ serial no. ………………………………... I’ve checked it and its o.K ! Quality / finish parts wood burning tray wood cover plates (internal & external fitted) cast fuel retainer firebox liners throat plate air wash (function) door catch / nickel door handl...