Ab ABSC02782 Installation, Operation & Maintenance Manual

Summary of ABSC02782

  • Page 1

    Installation, operation & maintenance manual residential steambath generator systems leave with home owne r leave with homeo wner aquabrass.Com.

  • Page 2

    Residential steambath generator systems table of contents s elect your model . . . . . . . . . . . . . . . . . .2 b efore installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 s team r oom guidelines . . . . . . . . . . . . . . . . . . . . . . . .3 locating the s team generator uni...

  • Page 3: Ansi

    Residential steambath generator systems 1 important note: a s you follow these instructions, you will notice warning and caution symbols. T his blocked infor- mation is important for the safe and effi- cient installation and operation of this gen- erator. T hese are types of potential hazards that m...

  • Page 4

    Residential steambath generator systems 2 select your model 1. Measure the length, width, & height (in ft.) of steam shower or tub/shower being used. Multiply the length x width x height to get the b asic r oom volume in cub ic fe e t l _______ x w _______ x h _______ = a 2. Add to the room volume (...

  • Page 5

    Residential steambath generator systems 3 before installing important: the following general information should be used in conjunction with consultations with your architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam room. R ead these instruc...

  • Page 6

    Re s i de n t i a l st e a m ba t h ge n e r a t o r sy s t e m s 4 l o c a t i n g t h e st e a m ge n e r a t o r u n i t select a location as near as practical and outside the steam room. Typical locations include: closet, vanity cabinet, heated attic or basement. 1. Locate steambath generator wi...

  • Page 7

    Installation plumbing all plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Use unions on all pipe connections. Use only brass piping or copper tubing as permitted by codes. Do not use black, galvanized or pvc pipe. Water supply (...

  • Page 8

    Residential steambath generator systems 6 generator dimensions /----- f ----\ /----- l ---\ /--------------\ 12” (305mm) /---------------- m -----------------\ /------------------------------------------------------------ k -----------------------------------------------------------\ /--------------...

  • Page 9

    Residential steambath generator systems 7 ! Caution electrical specifications all electrical wiring to be installed by a qualified licensed electrician in accordance with national e lectrical code and local electrical code. Power wiring s ee “ field power wiring” diagrams (page 8) 1. Check power vol...

  • Page 10

    Power block fuse block contactor fuse ground lug knock-out (conduit and fittings omitted for clarity) l2 l1 ground residential steambath generator systems 8 models absc02787, absc02789 (single phase wiring shown) l, n ground to be field wired to avoid e quipme nt damage do not conne ct powe r s uppl...

  • Page 11

    Residential steambath generator systems 9 automatic drain cord connector automatic drain cord automatic drain valve arrow indicates correct direction of flow plumb to drain line in accordance with code steam generator e l p p i n e v l a v n i a r d (shown in the connect open position copper or brass...

  • Page 12

    Installing the aquasteam in-shower temperature probe the r emote temperature probe is for use with in-shower controls. Controls only. Do not use any other controls. Do not use any other temperature probe with the in-shower controls. Noncompatible products may result in an inoperative control and a h...

  • Page 13

    11 5. R oute the end of the temperature probe cable with the temperature probe through the wall into the steam room as shown in diagram 3. Important note: do not strain, staple, pinch or otherwise damage the probe cable. 6. With a minimal length of the cable exposed apply sili- cone (provided) to th...

  • Page 14

    Installating the in-shower control important: turn power to the steam generator off before installing the control. Failure to turn the power offwill result in an inoperable control. Step 1 determine the desired installation location of the control. The control is designed to be installed inside or o...

  • Page 15

    Connection of aquasteam control & temperaturesensor temp probe main control note: valve should be closed when automatic drain is not installed aquabrass.Com residential steambath generator systems 13.

  • Page 16

    Residential steambath generator systems operation of the in-shower control on/off key on/off k ey is used to turn the steam generator on/off. Press on/offkey to turn steam generator on. Press a second time to turn steam generator off. A built-in timer automatically shuts the steam generator offa pre...

  • Page 17

    Replacement parts diagram shown with access cover removed for clarity note: for illustrative purposes only. S ome components may be omitted or altered for clarity. Do not use for wiring, repair or other purposes not related to component identification. Replacement parts list ________________________...

  • Page 18

    16 residential steambath warranty limited lifetime warranty aquasteam extends to the original consumer purchaser of a aquasteam. Residential steambath generator (aquasteam generator), installed in the united states or canada (excluding controls and accessories), a warranty that such aquasteam genera...

  • Page 20

    Residential steambath generators and control by aquabrass aquabrass.Com.