ABATEMENT AQUATRAP AT250R Operating Manual

Other manuals for AQUATRAP AT250R: Operating Manual
Manual is about: LGR Dehumidifier

Summary of AQUATRAP AT250R

  • Page 1

    Read and study manual before use aquatrap ® lgr dehumidifier model at250r operating manual.

  • Page 2: Safety Instructions

    Abatement dehumidifiers are used by professionals for the drying out of wet materials such as carpets, carpet cushions, floors, walls, building contents and more. They reduce the water in enclosed structural environments like buildings or parts of a building by removing water vapor from the air. Saf...

  • Page 3

    Create a closed drying chamber the dehumidifier should be operated in an enclosed space in order to create a drying chamber. Close all doors, windows or areas that open to the outside to maximize the unit’s water removal efficiency. Inside the drying chamber, air should circulate freely. Open interi...

  • Page 4: Operating Your Dehumidifier

    Operating your dehumidifier place the dehumidifier in upright position if the dehumidifier has been laid down in a horizontal position for any time over a few minutes, you must set it upright (vertical) for 30 minutes before starting. Connect the drainage system you can find the hose wrapped around ...

  • Page 5

    How to use the touch pad control panel touch pad control panel includes: • one lcd display, • one indicator light (red/green) and • five touch pad keys for dehumidifier operations. Lcd display: dehumidifier on. Purge on. The pump is on and pumping water out of the condensate reservoir. Defrost on. F...

  • Page 6

    Touch pad keys: on/off. Press the on/off key to turn the machine on or off. When the machine is turned on, it comes on in standby mode. The red indicator light and lcd light up. Lcd displays the “timer” clock icon. Four time digits flash, which prompts the operator to either set the “timer” by press...

  • Page 7

    Touch pad keys (cont.): purge. Press the purge key to empty water from the pump reservoir. During normal operation, the pump purges automatically whenever the reservoir is full. The display will show the purge on icon. To purge the pump manually before transportation: stop dehumidification using the...

  • Page 8: Maintenance

    Error messages message icon description er01 “pump on” flashing problem with pump or the drain tube is kinked. Er02 n/a check coil temperature sensor at the side of coil and the sensor cable. Er03 n/a check ambient temperature sensor in the front of the coil and the sensor cable. Note:. When er01 or...

  • Page 9: Warranty

    Periodic inspections (as needed) make sure the unit is unplugged. Remove housing, in order to locate the coil, pump and drain hose. • check coil and clean visible dirty vacuum both sides of the coils until clean. • check pump inspect and clean the pump system regularly to maintain effective operatio...

  • Page 10: Declaration Of Conformity

    Declaration of conformity we, declare under sole responsibility that our model dehumidifiers to which this declaration relates are in conformity with the following standards : emc : en 55014 - 1:2006,en 55014-2:1997+a1:2001 electromagnetic compatibility: emission requirement en 61000 - 3 - 2:2006,en...

  • Page 11: Specifications

    Specifications model at250r water removal (90°f / 90% rh) 266pints / 126l per day water removal (81°f / 60% rh) 147pints / 70l per day water removal (50°f / 70% rh) 69pints / 33l per day operating temp. Range 34° - 100° f refrigerant r410a max power consumption 1500 watt voltage / cycle 115v / 60hz ...